Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Osteoporos Int ; 29(8): 1931, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29971456

RESUMEN

This article was originally published under a CC BY-NC-ND 4.0 license, but has now been made available under a CC BY 4.0 license. The PDF and HTML versions of the paper have been modified accordingly.

2.
Osteoporos Int ; 28(7): 2195-2205, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28349251

RESUMEN

Magnesium has a key role in osteoporosis and could enhance implant osseointegration in osteoporotic patients. Titanium implants impregnated with Mg ions were installed in the tibia of ovariectomized rats. The release of Mg induced a significant increase of bone formation and the expression of anabolic markers in the peri-implant bone. INTRODUCTION: The success of endosseous implants is highly predictable in patients possessing normal bone status, but it may be impaired in patients with osteoporosis. Thus, the application of strategies that adjuvate implant healing in compromized sites is of great interest. Magnesium has a key role in osteoporosis prevention and it is an interesting candidate for this purpose. In this study, the cellular and molecular effects of magnesium release from implants were investigated at the early healing stages of implant integration. METHODS: Osteoporosis was induced in 24 female rats by means of ovariectomy and low-calcium diet. Titanium mini-screws were coated with mesoporous titania films and were loaded with magnesium (test group) or left as native (control group). The implants were inserted in the tibia and femur of the rats. One, 2 and 7 days after implantation, the implants were retrieved and histologically examined. In addition, expression of genes was evaluated in the peri-implant bone tissue at day 7 by means of quantitative polymerase chain reactions with pathway-oriented arrays. RESULTS: The histological evaluation revealed that new bone formation started already during the first week of healing for both groups. However, around the test implants, new bone was significantly more abundant and spread along a larger surface of the implants. In addition, the release of magnesium induced a significantly higher expression of BMP6. CONCLUSIONS: These results provide evidence that the release of magnesium promoted rapid bone formation and the activation of osteogenic signals in the vicinity of implants placed in osteoporotic bone.


Asunto(s)
Implantes Experimentales , Magnesio/farmacología , Oseointegración/efectos de los fármacos , Osteoporosis/fisiopatología , Animales , Tornillos Óseos , Materiales Biocompatibles Revestidos , Femenino , Regulación de la Expresión Génica/efectos de los fármacos , Magnesio/administración & dosificación , Oseointegración/genética , Osteogénesis/efectos de los fármacos , Osteogénesis/genética , Osteoporosis/genética , Osteoporosis/patología , Ovariectomía , Diseño de Prótesis , Ratas Sprague-Dawley , Propiedades de Superficie , Titanio
3.
J Oral Rehabil ; 43(2): 127-35, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26333185

RESUMEN

Crown/implant (C/I) ratio has been proven to not affect the survival of the implants; however, it is also a fact that no evidence exists with regard to the use of single short implants in the mandibular molar. The aim of this study was to determine whether the crown/implant ratios of single implant-supported fixed restorations on implants of 6-8 mm in the mandibular molar have an impact on the implant survival and marginal bone maintenance. Twelve short dental implants (6-8 mm) were installed and restored with single crowns, loaded after 3 months of healing. The restorations were divided according to crown-to-implant ratio into two groups: Group 1: C/I < 2.0 and Group 2: C/I ≧ 2.0. Alveolar bone loss was measured using CBCT scan, taken at the implant placement and after 12 months follow-up from loading. Reduced implant/crown ratio shown no statistic significant differences on implant survival and the alveolar bone level compared with recommended implant/crown ratio. Within the limitation of this study, it can be concluded that reduced C/I ratio could be used as a substitute for recommended C/I ratio in severely mandibular atrophic residual alveolar ridges.


Asunto(s)
Pérdida de Hueso Alveolar/patología , Implantación Dental Endoósea , Implantes Dentales de Diente Único , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Arcada Parcialmente Edéntula/rehabilitación , Coronas , Diseño de Prótesis Dental , Humanos , Mandíbula , Diente Molar , Resultado del Tratamiento
4.
Clin Oral Implants Res ; 25(9): 1051-5, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23782296

RESUMEN

OBJECTIVE: To investigate the bone stimulatory effect of compression forces through histomorphometric analyses of macrothreaded implants with microthreads in between. MATERIAL AND METHODS: Two sets of turned implants with different macrogeometries were prepared. The test group possessed microthreads in between macrothreads, and the control group had macrothreads only. The two-implant groups were placed in both the femur and the tibiae of 10 rabbits. After 4 weeks, the animals were sacrificed and were subjected to histologic processing and histomorphometry. On the prepared stained sections, the total bone area (BA), new BA and bone-to-implant (BIC) were calculated. RESULTS: The mean new BA% (SD) for the test group in the femur presented significantly higher values compared with the control group, being 32.84 (32.5) ± 6.04 and 27.31 (28.19) ± 5.66, respectively (P = 0.04). There were no differences for the new BA in the tibia or the total BA% for both bone types (P = 0.86, P = 0.131, and P = 0.131, respectively). The mean BIC% (SD) in the femur was 13.66 (11.49) ± 6.86 for the test group and 8.48 (7.92) ± 3.31 for the control group and in the tibia, 11.4 (11.88) ± 4.21 for the test group and 13.91 (12.06) ± 6.07 for the control group, respectively. There was no statistical significance among the groups tested. CONCLUSION: The modified implant macrogeometry with microthreads in between promoted effect in the femur. However, no statistical differences could be seen in the tibia, suggesting that the modification may be more effective in bone with poor bone quality, such as in the maxillary bone.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Implantes Experimentales , Oseointegración , Animales , Fémur/cirugía , Conejos , Propiedades de Superficie , Tibia/cirugía , Titanio
5.
Clin Oral Implants Res ; 25(6): 749-54, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23442170

RESUMEN

OBJECTIVES: Previously, we have reported that photocatalytically active hydrophilicity of the anatase titanium dioxide (TiO2) nanoparticles coated onto commercially pure titanium discs presented significantly improved hydrophilicity after ultraviolet irradiation. As hydrophilicity has shown enhancement of osseointegration, the in vivo responses were of great interest. The aim of this study was to evaluate whether or not the photo-activated hydrophilicity generated at the time of implant placement has an effect on the longer healing periods for osseointegration. MATERIALS AND METHODS: Photocatatytically active nanostructured TiO2 powder (Degussa P-25), which consists of approximately 80% anatase and 20% rutile, was spin-coated onto commercially pure titanium discs and was heat-treated thereafter. These P25-coated discs were irradiated with ultraviolet (UV) light for the test (+UV) group, and non-irradiated discs were prepared for the control (-UV) group. Both groups of discs were placed in the rabbits' tibiae. After 12 weeks of healing period, histological analysis and gene expression analysis using real-time RT-PCR were performed. RESULTS: From the histological analyses, there were no specific differences between -UV and +UV groups. However, from the gene expression analysis, ALP, RUNX-2 and IL-10 were significantly upregulated for the +UV group compared with the -UV group. CONCLUSIONS: The biologically enhancing effect to photocatalytically activated surfaces remained even after 12 weeks of healing time in terms of genetic responses.


Asunto(s)
Remodelación Ósea/fisiología , Implantación Dental Endoósea , Implantes Dentales , Oseointegración/fisiología , Titanio/farmacología , Rayos Ultravioleta , Cicatrización de Heridas/fisiología , Animales , Miembro Posterior/cirugía , Nanopartículas , Conejos , Reacción en Cadena en Tiempo Real de la Polimerasa
6.
J Oral Rehabil ; 39(5): 391-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22175784

RESUMEN

Titanium or zirconium computer-aided design/computer-aided manufacturing abutments are now widely used for aesthetic implant treatments; however, information regarding microscopic structural differences that may influence the biological and mechanical outcomes of different implant systems is limited. Therefore, the characteristics of different connection systems were investigated. Optical microscopic observation and scanning electron microscopy showed different characteristics of two internal systems, namely the Astra Tech and the Replace Select system, and for different materials. The scanning electron microscopic observation showed for the Astra Tech that the implant-abutment interface seemed to be completely sealed for both titanium and zirconium abutments, both horizontally and sagittally; however, the first implant-abutment contact was below the fixture top, creating a microgap, and fixtures connected with titanium abutments showed significantly larger values (23·56µm±5·44 in width, and 168·78µm±30·39 in depth, P<0·001). For Replace Select, scanning electron microscopy in the sagittal direction showed that the sealing of titanium and zirconium abutments differed. The seal between the implant-titanium and implant-zirconium abutments seemed to be complete at the butt-joint interface; however, the displacement of the abutment in relation to the fixture in the lateral direction was evident for both abutments with no statistical differences (P>0·70), creating an inverted microgap. Thus, microscopy evaluation of two commonly used internal systems connected to titanium or zirconium abutments showed that the implant-abutment interface was perfectly sealed under no-loading conditions. However, an inverted microgap was seen in both systems, which may result in bacterial accumulation as well as alteration of stress distribution at the implant-abutment interface.


Asunto(s)
Implantes Dentales/normas , Materiales Dentales/química , Ensayo de Materiales , Titanio/química , Circonio/química , Diseño Asistido por Computadora , Pilares Dentales , Diseño de Implante Dental-Pilar/métodos , Humanos , Microscopía Electrónica de Rastreo
7.
Br J Oral Maxillofac Surg ; 57(1): 41-46, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30612838

RESUMEN

Our aim was to try and find out whether contamination with saliva during insertion of dental implants affects osseointegration in bone that has been augmented with different grafts. Six bony defects were created in each of the calvaria of six sheep, and then augmented with three different materials (autogenous bone, bovine bone, and resorbable biphasic ceramic bone substitute) After five weeks of healing, three implants contaminated with saliva (contaminated group) and three not contaminated (uncontaminated group) were placed in the centre of the augmented areas. For histomorphometric analysis, bone implant contact, bone area fraction occupancy, bone and material area, and bony area were measured after a healing period of five weeks. There was a significant difference between the contaminated and uncontaminated groups (p=0.036) for bone implant contact only in the augmented areas, but there were no significant differences in bone area fraction occupancy, bone and material area, and bony area. We conclude that contamination with saliva during placement of dental implants can significantly compromise bone implant contact in augmented areas, but had no significant effect on the formation of bone in areas more distant from the surface of the implant. We suggest that salivary contamination should be avoided during placement of dental implants in augmented areas.


Asunto(s)
Sustitutos de Huesos , Saliva , Aumento de la Cresta Alveolar , Animales , Bovinos , Implantación Dental Endoósea , Implantes Dentales , Oseointegración , Ovinos , Cráneo
8.
Clin Nephrol ; 68(2): 104-8, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17722710

RESUMEN

Antineutrophil cytoplasmic antibody-(ANCA) associated glomerulonephritis usually shows histopathologic features of pauciimmune crescentic glomerulonephritis and occurs late in life. We report a 14-year-old Japanese girl presenting with proteinuria, hematuria and mildly elevated serum creatinine. A renal biopsy specimen demonstrated crescentic glomerulonephritis, immunofluorescence showed mesangial IgA staining. Electron microscopic examination disclosed paramesangial deposits. Serum ANCA against myeloperoxidase (MPO) were detected at high titers. Myeloperoxidase-ANCA-related nephritis accompanied by IgA nephropathy is considered rare in childhood and teen years. Yet, if ANCA assays and detailed electron microscopic examination of renal specimens were performed routinely in patients with rapidly progressive glomerulonephritis, the diagnosis might be more frequent in young patients.


Asunto(s)
Anticuerpos Anticitoplasma de Neutrófilos , Mesangio Glomerular , Glomerulonefritis/inmunología , Glomerulonefritis/patología , Inmunoglobulina A , Adolescente , Femenino , Mesangio Glomerular/química , Mesangio Glomerular/patología , Humanos , Inmunoglobulina A/análisis
9.
Br J Oral Maxillofac Surg ; 53(6): 550-6, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25921363

RESUMEN

Our aim was to find out whether simplified drilling protocols would provide biological responses comparable to those of conventional drilling protocols at the low rotational speed of 400rpm. Seventy-eight root form endosseous implants with diameters of 3.75, 4.2, and 5mm were placed into canine tibias and allowed to heal for 3 and 5 weeks. After the dogs had been killed, the samples of implanted bone were retrieved and processed for non-decalcified histological sectioning. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) analyses were made on the histological sections. Implants treated by the simplified protocol resulted in BIC and BAFO values comparable to those obtained with the conventional drilling protocol, and there were no significant differences in the technique or diameter of the drilling. The results suggest that the simplified procedure gives biological outcomes comparable to those of the conventional procedure.


Asunto(s)
Implantación Dental Endoósea/métodos , Oseointegración/fisiología , Osteotomía/métodos , Grabado Ácido Dental/métodos , Aleaciones , Animales , Interfase Hueso-Implante/anatomía & histología , Aleaciones Dentales/química , Grabado Dental/métodos , Implantación Dental Endoósea/instrumentación , Diseño de Prótesis Dental , Perros , Osteogénesis/fisiología , Osteotomía/instrumentación , Rotación , Propiedades de Superficie , Tibia/anatomía & histología , Tibia/cirugía , Factores de Tiempo , Titanio/química
10.
J Biomater Appl ; 29(5): 737-47, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25015653

RESUMEN

OBJECTIVE: To investigate the bone response to threaded polyetheretherketone (PEEK) implants coated with nanohydroxyapatite. MATERIALS AND METHODS: A total of 39 PEEK implants were coated with nanocrystalline hydroxyapatite and 39 uncoated implants were used as controls. The implant surface was characterized by optical interferometry and scanning electron microscope. The implants were inserted in the tibia and femur of 13 rabbits. After 6 weeks of healing, quantitative and qualitative analyses were performed. RESULTS: The test implants showed significantly higher removal torque test values compared with the control group. Histomorphometric evaluation demonstrated higher bone-to-implant contact for the test implants; however, there were no differences in bone area between the groups. Qualitative histological analyses demonstrated inflammatory cellular reactions in close vicinity of both implant surfaces. A two-cell layer of foreign body giant cells was observed irrespective of sample type. CONCLUSION: Our findings demonstrate that implants with a threaded design render good stability to PEEK in both coated and uncoated implants. Nanohydroxyapatite-coated PEEK implants demonstrated improved bone formation compared with uncoated controls.


Asunto(s)
Huesos/patología , Materiales Biocompatibles Revestidos/química , Durapatita/química , Cetonas/química , Nanoestructuras/química , Polietilenglicoles/química , Prótesis e Implantes , Animales , Benzofenonas , Cristalización , Femenino , Fémur/patología , Implantes Experimentales , Microscopía Electrónica de Rastreo , Nanopartículas/química , Nanotecnología , Oseointegración , Polímeros , Conejos , Estrés Mecánico , Propiedades de Superficie , Torque
11.
Int J Oral Maxillofac Surg ; 43(7): 883-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24583140

RESUMEN

Information concerning the effects of the implant cutting flute design on initial stability and its influence on osseointegration in vivo is limited. This study evaluated the early effects of implants with a specific cutting flute design placed in the sheep mandible. Forty-eight dental implants with two different macro-geometries (24 with a specific cutting flute design - Blossom group; 24 with a self-tapping design - DT group) were inserted into the mandibular bodies of six sheep; the maximum insertion torque was recorded. Samples were retrieved and processed for histomorphometric analysis after 3 and 6 weeks. The mean insertion torque was lower for Blossom implants (P<0.001). No differences in histomorphometric results were observed between the groups. At 3 weeks, P=0.58 for bone-to-implant contact (BIC) and P=0.52 for bone area fraction occupied (BAFO); at 6 weeks, P=0.55 for BIC and P=0.45 for BAFO. While no histomorphometric differences were observed, ground sections showed different healing patterns between the implants, with better peri-implant bone organization around those with the specific cutting flute design (Blossom group). Implants with the modified cutting flute design had a significantly reduced insertion torque compared to the DT implants with a traditional cutting thread, and resulted in a different healing pattern.


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales , Diseño de Prótesis Dental , Oseointegración/fisiología , Animales , Análisis del Estrés Dental , Mandíbula/cirugía , Modelos Animales , Ovinos , Torque , Cicatrización de Heridas/fisiología
12.
Int J Oral Maxillofac Surg ; 43(2): 251-60, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23948358

RESUMEN

This in vivo study investigated the in vivo performance of two newly developed synthetic bone substitutes and compared them to commercially available xenografts (Bio-Oss, Geistlich Pharma AG, Switzerland; OsteoGraf, Dentsply, USA). The materials were tested in a rabbit calvaria model, and the bone forming properties were observed at 4 and 8 weeks after implantation by means of histomorphometry and micro computed tomography (micro-CT). Defects without any graft material were used as negative controls. Micro-CT showed that all materials tested presented new bone formation that filled the defects at both time points, whereas the negative control presented less bone formation, with soft tissue infiltration into the defects. Comparable bone fill percentages were observed for histomorphometric and micro-CT results. Even though no statistically significant difference was found quantitatively between all of the bone graft substitute groups, a higher mean decrease in graft material filling the defects, along with higher remodelling activity, was evident for the experimental materials compared to the commercially available xenografts at 8 weeks. The results indicate that the experimental materials possess high degradability, along with osteoconduction comparable to commercially available xenografts.


Asunto(s)
Regeneración Ósea/fisiología , Sustitutos de Huesos/farmacología , Trasplante Óseo/métodos , Cráneo/cirugía , Animales , Bovinos , Xenoinjertos , Minerales/farmacología , Conejos , Microtomografía por Rayos X
13.
Int J Oral Maxillofac Surg ; 43(10): 1269-75, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24794761

RESUMEN

This study investigated the effect of undersized preparations with two different implant macrogeometries. There were four experimental groups: group 1, conical implant with an undersized osteotomy of 3.2mm; group 2, conical implant with an undersized osteotomy of 3.5mm; group 3, cylindrical implant with an undersized osteotomy of 3.2mm; group 4, cylindrical implant with an undersized osteotomy of 3.5mm. Implants were placed in one side of the sheep mandible (n=6). After 3 weeks, the same procedure was conducted on the other side; 3 weeks later, euthanasia was performed. All implants were 4mm×10mm. Insertion torque was recorded for all implants during implantation. Retrieved samples were subjected to histological sectioning and histomorphometry. Implants of groups 1 and 2 presented significantly higher insertion torque than those of groups 3 and 4 (P<0.001). No differences in bone-to-implant contact or bone area fraction occupied were observed between the groups at 3 weeks (P>0.24, and P>0.25, respectively), whereas significant differences were observed at 6 weeks between groups 1 and 2, and between groups 3 and 4 (P<0.01). Undersized drilling affected the biological establishment of bone formation around both dental implant macrogeometries.


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales , Mandíbula/cirugía , Animales , Diseño de Prótesis Dental , Implantes Experimentales , Oseointegración , Osteotomía , Ovinos , Propiedades de Superficie , Torque
14.
Int J Oral Maxillofac Surg ; 42(5): 677-82, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23228694

RESUMEN

Laminin-1 has been reported as one of the factors responsible for the nucleation of calcium phosphates and, in vitro, has been reported to selectively recruit osteoprogenitors. This article focused on its in vivo effects, and evaluated the effect of laminin-1 local application on osseointegration. Polished cylindrical hydroxyapatite implants were coated with laminin-1 (test) and the bone responses in the rabbit tibiae after 2 and 4 weeks were evaluated and compared to the non-coated implants (control). Before the samples were processed for histological sectioning, they were three-dimensionally analysed with micro computed tomography (µCT). Both evaluation methods were analysed with regards to bone area around the implant and bone to implant contact. From the histologic observation, new bone formation around the laminin-1 coated implant at 2 weeks seemed to have increased the amount of supporting bone around the implant, however, at 4 weeks, the two groups presented no notable differences. The two-dimensional and three-dimensional morphometric evaluation revealed that both histologic and three-dimensional analysis showed some tendency in favour of the test group implants, however there was no statistical significance between the test and control group results.


Asunto(s)
Materiales Biocompatibles Revestidos/farmacología , Implantes Dentales , Laminina/farmacología , Oseointegración/efectos de los fármacos , Adsorción , Animales , Diseño Asistido por Computadora , Grabado Dental/métodos , Diamante/química , Durapatita/química , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Interferometría/métodos , Masculino , Osteogénesis/efectos de los fármacos , Conejos , Propiedades de Superficie , Tibia/efectos de los fármacos , Tibia/patología , Factores de Tiempo , Microtomografía por Rayos X/métodos
15.
J Dent Res ; 91(12): 1172-7, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23045363

RESUMEN

Nanostructure modification of dental implants has long been sought as a means to improve osseointegration through enhanced biomimicry of host structures. Several methods have been proposed and demonstrated for creating nanotopographic features; here we describe a nanoscale hydroxyapatite (HA)-coated implant surface and hypothesize that it will hasten osseointegration and improve its quality relative to that of non-coated implants. Twenty threaded titanium alloy implants, half prepared with a stable HA nanoparticle surface and half grit-blasted, acid-etched, and heat-treated (HT), were inserted into rabbit femurs. Pre-operatively, the implants were morphologically and topographically characterized. After 3 weeks of healing, the samples were retrieved for histomorphometry. The nanomechanical properties of the surrounding bone were evaluated by nanoindentation. While both implants revealed similar bone-to-implant contact, the nanoindentation demonstrated that the tissue quality was significantly enhanced around the HA-coated implants, validating the postulated hypothesis.


Asunto(s)
Materiales Biocompatibles Revestidos/administración & dosificación , Implantes Dentales , Diseño de Prótesis Dental , Hidroxiapatitas/administración & dosificación , Nanopartículas/administración & dosificación , Oseointegración/fisiología , Animales , Fenómenos Biomecánicos , Materiales Biocompatibles Revestidos/química , Aleaciones Dentales/química , Hidroxiapatitas/química , Ensayo de Materiales , Nanopartículas/química , Oseointegración/efectos de los fármacos , Conejos , Propiedades de Superficie , Tibia/efectos de los fármacos , Tibia/cirugía , Tibia/ultraestructura
16.
J Dent Res ; 90(12): 1422-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21933935

RESUMEN

Nanostructured calcium phosphate (CaP) has been histologically and biomechanically proven to enhance osseointegration of implants; however, conventional techniques were not sufficiently sensitive to capture its biological effects fully. Here, we compared the conventional removal torque (RTQ) evaluation and gene expression in tissues around nanostructured CaP-coated implants, using real-time RT-PCR, with those of uncoated implants, in a rabbit model. At 2 wks, RTQ values were significantly higher, alkaline phosphatase (ALP) expression was significantly higher, and runt-related transcription factor 2 and tumor necrosis factor-α expressions were significantly lower in the coated than in the uncoated implants. This indicates that inflammatory responses were suppressed and osteoprogenitor activity increased around the CaP-coated surface. At 4 wks, although RTQ values did not significantly differ between the 2 groups, ALP and osteocalcin (OCN) were significantly up-regulated in the coated group, indicating progressive mineralization of the bone around the implant. Moreover, an osteoclast marker, adenosine triphosphatase, which indicates acidification of the resorption lacunae, was significantly higher for the coated implants, suggesting gradual resorption of the CaP coating. This study reveals detailed genetic responses to nanostructured CaP-coated implants and provides evidence that the effect of nanotopography is significant during the osseointegration cascade.


Asunto(s)
Materiales Biocompatibles Revestidos , Análisis del Estrés Dental , Implantes Experimentales , Osteoblastos/metabolismo , Fosfatasa Ácida/biosíntesis , Animales , Fosfatos de Calcio , Subunidad alfa 1 del Factor de Unión al Sitio Principal/biosíntesis , Remoción de Dispositivos , Expresión Génica , Isoenzimas/biosíntesis , Nanopartículas , Osteocalcina/biosíntesis , Conejos , Distribución Aleatoria , Reacción en Cadena en Tiempo Real de la Polimerasa , Fosfatasa Ácida Tartratorresistente , Torque , Factor de Necrosis Tumoral alfa/biosíntesis
17.
Med. oral patol. oral cir. bucal (Internet) ; 20(4): e471-e479, jul. 2015. ilus
Artículo en Inglés | IBECS (España) | ID: ibc-138975

RESUMEN

BACKGROUND: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. MATERIAL AND METHODS: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. RESULTS: The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p < 0.001). No significant differences were detected between implant designs for each drilling technique (p > 0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p < 0.03) only, but not for those placed in the 3.75 mm drilling sites (p > 0.32). CONCLUSIONS: Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed


Asunto(s)
Animales , Perros , Oseointegración/fisiología , Implantes Dentales/normas , Implantes Dentales/tendencias , Implantes Dentales , Modelos Animales , Implantes Dentales/ética , Implantes Dentales/estadística & datos numéricos , Implantes Dentales/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA