Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Folia Phoniatr Logop ; 76(1): 102-108, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37544306

RESUMEN

INTRODUCTION: In times of COVID-19, gargling disinfectant is commonly used. Disinfectant solutions seem to decrease the infection's symptoms. For disinfection, several techniques are reported. So far, there are no data about the regions in the upper airways achieved by gargled fluid. METHODS: Ten healthy volunteers without any dysphagia were investigated with a high-sensitivity flexible endoscopic evaluation of swallowing (hsFEES®) during and after gargling colored water. One volunteer repeated the gargling process in fast and real-time MRI. RESULTS: In all cases, no color accumulation was detected on the posterior pharyngeal wall, epi- or hypopharynx during gargling. The MRI scans confirmed the results. CONCLUSIONS: hsFEES® and fast MRI provide an insight into the gargling pattern. Data show that during gargling, the fluid covers the soft tissue in the oral cavity and the anterior part of the soft palate, but not the posterior pharyngeal wall nor the epi- and hypopharynx.


Asunto(s)
Desinfectantes , Faringe , Humanos , Desinfectantes/farmacología , Antisépticos Bucales , Tráquea , Paladar Blando
2.
Radiology ; 308(1): e230084, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37404154

RESUMEN

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Asunto(s)
Fibrosis Quística , Humanos , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/tratamiento farmacológico , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mutación
3.
Magn Reson Med ; 89(4): 1644-1659, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36468622

RESUMEN

PURPOSE: In this work, a new method to determine the gradient system transfer function (GSTF) with high frequency resolution and high SNR is presented, using fast and simple phantom measurements. The GSTF is an effective instrument for hardware characterization and calibration, which can be used to correct for gradient distortions, or enhance gradient fidelity. METHODS: The thin-slice approach for phantom-based measurements of the GSTF is expanded by adding excitations that are shifted after the application of the probing gradient, to capture long-lasting field fluctuations with high SNR. A physics-informed regularization procedure is implemented to derive high-quality transfer functions from a small number of measurements. The resulting GSTFs are evaluated by means of gradient time-course estimation and pre-emphasis of a trapezoidal test gradient on a 7T scanner. RESULTS: The GSTFs determined with the proposed method capture sharp mechanical resonances with a high level of detail. The measured trapezoidal gradient progressions are authentically reproduced by the GSTF estimations on all three axes. The GSTF-based pre-emphasis considerably improves the gradient fidelity in the plateau phase of the test gradient and almost completely eliminates lingering field oscillations. CONCLUSION: The presented approach allows fast and simple characterization of gradient field fluctuations caused by long-living eddy current and vibration effects, which become more pronounced at ultrahigh field strengths.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Calibración , Progresión de la Enfermedad
4.
Acta Radiol ; 64(5): 1851-1858, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36718493

RESUMEN

BACKGROUND: Ultrashort-echo-time (UTE) sequences have been developed to overcome technical limitations of pulmonary magnetic resonance imaging (MRI). Recently, it has been shown that UTE sequences with breath-hold allow rapid image acquisition with sufficient image quality. However, patients with impaired respiration require alternative acquisition strategies while breathing freely. PURPOSE: To compare the diagnostic performance of free-breathing three-dimensional (3D)-UTE sequences with different trajectories based on pulmonary imaging of immunocompromised patients. MATERIAL AND METHODS: In a prospective study setting, two 3D-UTE sequences performed in free-breathing and exploiting non-Cartesian trajectories-one using a stack-of-spirals and the other exploiting a radial trajectory-were acquired at 3 T in patients undergoing hematopoietic stem cell transplantation. Two radiologists assessed the images regarding presence of pleural effusions and pulmonary infiltrations. Computed tomography (CT) was used as reference. RESULTS: A total of 28 datasets, each consisting of free-breathing 3D-UTE MRI with the two sequence techniques and a reference CT scan, were acquired in 20 patients. Interrater agreement was substantial for pulmonary infiltrations using both sequence techniques (κ = 0.77 - 0.78). Regarding pleural effusions, agreement was almost perfect in the stack-of-spirals (κ = 0.81) and moderate in the radial sequence (κ = 0.59). No significant differences in detectability of the assessed pulmonary pathologies were observed between both 3D-UTE sequence techniques (P > 0.05), and their level of agreement was substantial throughout (κ = 0.62-0.81). Both techniques provided high sensitivities and specificities (79%-100%) for the detection of pulmonary infiltrations and pleural effusions compared to reference CT. CONCLUSION: The diagnostic performance of the assessed 3D-UTE MRI sequences was similar. Both sequences enable the detection of typical inflammatory lung pathologies.


Asunto(s)
Imagenología Tridimensional , Derrame Pleural , Humanos , Estudios Prospectivos , Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Respiración , Imagen por Resonancia Magnética/métodos
5.
Magn Reson Med ; 88(5): 2167-2178, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35692042

RESUMEN

PURPOSE: Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time-consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning-based reconstruction of undersampled spiral k-space data is presented to enable free breathing real-time cardiac MRI with good image quality and short reconstruction times. METHODS: Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non-Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard. RESULTS: The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model-based approaches. The VN furthermore performed better than a U-Net and not inferior to a low-rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data. CONCLUSIONS: The proposed VN method enables real-time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.


Asunto(s)
Imagen por Resonancia Magnética , Respiración , Corazón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Cintigrafía
6.
NMR Biomed ; 35(8): e4732, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35297111

RESUMEN

The purpose of the current study was to implement and validate joint real-time acquisition of functional and late gadolinium-enhancement (LGE) cardiac magnetic resonance (MR) images during free breathing. Inversion recovery cardiac real-time images with a temporal resolution of 50 ms were acquired using a spiral trajectory (IR-CRISPI) with a pre-emphasis based on the gradient system transfer function during free breathing. Functional and LGE cardiac MR images were reconstructed using a low-rank plus sparse model. Late gadolinium-enhancement appearance, image quality, and functional parameters of IR-CRISPI were compared with clinical standard balanced steady-state free precession breath-hold techniques in 10 patients. The acquisition of IR-CRISPI in free breathing of the entire left ventricle took 97 s on average. Bland-Altman analysis and Wilcoxon tests showed a higher artifact level for the breath-hold technique (p = 0.003), especially for arrhythmic patients or patients with dyspnea, but an increased noise level for IR-CRISPI of the LGE images (p = 0.01). The estimated transmural extent of the enhancement differed by not more than 25% and did not show a significant bias between the techniques (p = 0.50). The ascertained functional parameters were similar for the breath-hold technique and IR-CRISPI, that is, with a minor, nonsignificant (p = 0.16) mean difference of the ejection fraction of 2.3% and a 95% confidence interval from -4.8% to 9.4%. IR-CRISPI enables joint functional and LGE imaging in free breathing with good image quality but distinctly shorter scan times in comparison with breath-hold techniques.


Asunto(s)
Medios de Contraste , Gadolinio , Contencion de la Respiración , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados
7.
Magn Reson Med ; 85(5): 2747-2760, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33270942

RESUMEN

PURPOSE: Segmented Cartesian acquisition in breath hold represents the current gold standard for cardiac functional MRI. However, it is also associated with long imaging times and severe restrictions in arrhythmic or dyspneic patients. Therefore, we introduce a real-time imaging technique based on a spoiled gradient-echo sequence with undersampled spiral k-space trajectories corrected by a gradient pre-emphasis. METHODS: A fully automatic gradient waveform pre-emphasis based on the gradient system transfer function was implemented to compensate for gradient inaccuracies, to optimize fast double-oblique spiral MRI. The framework was tested in a phantom study and subsequently transferred to compressed sensing-accelerated cardiac functional MRI in real time. Spiral acquisitions during breath hold and free breathing were compared with this reference method for healthy subjects (N = 7) as well as patients (N = 2) diagnosed with heart failure and arrhythmia. Left-ventricular volumes and ejection fractions were determined and analyzed using a Wilcoxon signed-rank test. RESULTS: The pre-emphasis successfully reduced typical artifacts caused by k-space misregistrations. Dynamic cardiac imaging was possible in real time (temporal resolution < 50 ms) with high spatial resolution (1.34 × 1.34 mm2 ), resulting in a total scan time of less than 50 seconds for whole heart coverage. Comparable image quality, as well as similar left-ventricular volumes and ejection fractions, were observed for the accelerated and the reference method. CONCLUSION: The proposed technique enables high-resolution real-time cardiac MRI with no need for breath holds and electrocardiogram gating, shortening the duration of an entire functional cardiac exam to less than 1 minute.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Contencion de la Respiración , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Reproducibilidad de los Resultados
8.
Magn Reson Med ; 85(5): 2595-2607, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33231886

RESUMEN

PURPOSE: The aim of this study was to investigate the acceleration potential of wave-CAIPI (controlled aliasing in parallel imaging) for 4D flow MRI, provided that image quality and precision of flow parameters are maintained. METHODS: The 4D flow MRIs with acceleration factor R = 2 were performed on 10 healthy volunteers, using both wave-CAIPI and standard Cartesian/2D-CAIPI sampling for reference. In addition, 1 patient with known aortic valve stenosis was examined. The flow rate ( Q ), net flow ( Qnet ), peak velocity vmax , and net average through-plane velocity ( v¯âŠ¥ ) were calculated in eight analysis planes in the ascending and descending aorta. The acquisitions were retrospectively undersampled (R = 6), and deviations of flow parameters and hemodynamic flow patterns were evaluated. RESULTS: Flow parameters measured with an undersampled wave-CAIPI trajectory showed considerably smaller deviations to the references than the 2D-CAIPI images. For vmax , the mean absolute differences were 6.02±2.08 cm/s versus 14.36±5.68 cm/s; for Qnet , the mean absolute differences were 3.67±1.40 ml versus 5.87±1.91 ml for wave-CAIPI versus 2D-CAIPI, respectively. Noise calculations indicate that the 2D-CAIPI sampling exhibits a 43±38% higher average noise level than the wave-CAIPI technique. Qualitative discrepancies in hemodynamic flow patterns, visualized through streamlines, particle traces and flow velocity vectors, could be reduced by using the undersampled wave-CAIPI trajectory. CONCLUSION: Use of wave-CAIPI instead of 2D-CAIPI sampling in retrospectively 6-fold accelerated 4D flow MRI enhances the precision of flow parameters. The acquisition time of 4D flow measurements could be reduced by a factor of 3, with minimal differences in flow parameters.


Asunto(s)
Aorta , Imagen por Resonancia Magnética , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Voluntarios Sanos , Hemodinámica , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
BMC Cardiovasc Disord ; 21(1): 237, 2021 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-33980159

RESUMEN

BACKGROUND: The effect of smoking on coronary vasomotion has been investigated in the past with various imaging techniques in both short- and long-term smokers. Additionally, coronary vasomotion has been shown to be normalized in long-term smokers by L-Arginine acting as a substrate for NO synthase, revealing the coronary endothelium as the major site of abnormal vasomotor response. Aim of the prospective cohort study was to investigate coronary vasomotion of young healthy short-term smokers via magnetic resonance cold pressor test with and without the administration of L-Arginine and compare obtained results with the ones from nonsmokers. METHODS: Myocardial blood flow (MBF) was quantified with first-pass perfusion MRI on a 1.5 T scanner in healthy short-term smokers (N = 10, age: 25.0 ± 2.8 years, 5.0 ± 2.9 pack years) and nonsmokers (N = 10, age: 34.3 ± 13.6) both at rest and during cold pressor test (CPT). Smokers underwent an additional examination after administration of L-Arginine within a median of 7 days of the naïve examination. RESULTS: MBF at rest turned out to be 0.77 ± 0.30 (smokers with no L-Arginine; mean ± standard deviation), 0.66 ± 0.21 (smokers L-Arginine) and 0.84 ± 0.08 (nonsmokers). Values under CPT were 1.21 ± 0.42 (smokers no L-Arginine), 1.09 ± 0.35 (smokers L-Arginine) and 1.63 ± 0.33 (nonsmokers). In all groups, MBF was significantly increased under CPT compared to the corresponding rest examination (p < 0.05 in all cases). Additionally, MBF under CPT was significantly different between the smokers and the nonsmokers (p = 0.002). MBF at rest was significantly different between the smokers when L-Arginine was given and the nonsmokers (p = 0.035). CONCLUSION: Short-term smokers showed a reduced response to cold both with and without the administration of L-Arginine. However, absolute MBF values under CPT were lower compared to nonsmokers independently of L-Arginine administration.


Asunto(s)
Arginina/administración & dosificación , Frío , Vasos Coronarios/efectos de los fármacos , Endotelio Vascular/efectos de los fármacos , Imagen por Resonancia Magnética , Fumadores , Fumar/efectos adversos , Adulto , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/fisiopatología , Ex-Fumadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Fumar/fisiopatología , Vasoconstricción/efectos de los fármacos , Vasodilatación/efectos de los fármacos , Adulto Joven
10.
Radiology ; 296(1): 191-199, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32343212

RESUMEN

Background In cystic fibrosis (CF), recurrent imaging and pulmonary function tests (PFTs) are needed for the assessment of lung function during disease management. Purpose To assess the clinical feasibility of pulmonary three-dimensional ultrashort echo time (UTE) MRI at breath holding for quantitative image analysis of ventilation inhomogeneity and hyperinflation in CF compared with PFT. Materials and Methods In this prospective study from May 2018 to June 2019, participants with CF and healthy control participants underwent PFTs and functional lung MRI by using a prototypical single breath-hold three-dimensional UTE sequence. Fractional ventilation (FV) was calculated from acquired data in normal inspiration and normal expiration. FV of each voxel was normalized to the whole lung mean (FVN), and interquartile range of normalized ventilation (IQRN; as a measure of ventilation heterogeneity) was calculated. UTE signal intensity (SI) was assessed in full expiration (SIN, normalized to aortic blood). Obtained metrics were compared between participants with CF and control participants. For participants with CF, MRI metrics were correlated with the standard lung clearance index (LCI) and PFT. Mann-Whitney U tests and Spearman correlation were used for statistical analysis. Results Twenty participants with CF (mean age, 17 years ± 9 [standard deviation]; 12 men) and 10 healthy control participants (24 years ± 8; five men) were included. IQRN was higher for participants with CF than for control participants (mean, 0.66 ± 0.16 vs 0.50 ± 0.04, respectively; P = .007). In the 20 participants with CF, IQRN correlated with obstruction markers forced expiratory volume in 1 second-to-forced vital capacity ratio (r = -0.70; 95% confidence interval [CI]: -0.92, -0.28; P < .001), mean expiratory flow 25% (r = 0.78; 95% CI: -0.95, -0.39; P < .001), and with the ventilation inhomogeneity parameter LCI (r = 0.90; 95% CI: 0.69, 0.96; P < .001). Mean SIN in full expiration was lower in participants with CF than in control participants (0.34 ± 0.08 vs 0.39 ± 0.03, respectively; P = .03). Conclusion Three-dimensional ultrashort echo time MRI in the lungs allowed for functional imaging of ventilation inhomogeneity within a few breath holds in patients with cystic fibrosis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Asunto(s)
Fibrosis Quística/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Estudios de Factibilidad , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Estudios Prospectivos
11.
Magn Reson Med ; 83(4): 1519-1527, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31592559

RESUMEN

PURPOSE: The gradient system transfer function (GSTF) characterizes the frequency transfer behavior of a dynamic gradient system and can be used to correct non-Cartesian k-space trajectories. This study analyzes the impact of the gradient coil temperature of a 3T scanner on the GSTF. METHODS: GSTF self- and B0 -cross-terms were acquired for a 3T Siemens scanner (Siemens Healthcare, Erlangen, Germany) using a phantom-based measurement technique. The GSTF terms were measured for various temperature states up to 45°C. The gradient coil temperatures were measured continuously utilizing 12 temperature sensors which are integrated by the vendor. Different modeling approaches were applied and compared. RESULTS: The self-terms depend linearly on temperature, whereas the B0 -cross-term does not. Effects induced by thermal variation are negligible for the phase response. The self-terms are best represented by a linear model including the three gradient coil sensors that showed the maximum temperature dependence for the three axes. The use of time derivatives of the temperature did not lead to an improvement of the model. The B0 -cross-terms can be modeled by a convolution model which considers coil-specific heat transportation. CONCLUSION: The temperature dependency of the GSTF was analyzed for a 3T Siemens scanner. The self- and B0 -cross-terms can be modeled using a linear and convolution modeling approach based on the three main temperature sensor elements.


Asunto(s)
Imagen por Resonancia Magnética , Alemania , Modelos Lineales , Fantasmas de Imagen , Temperatura
12.
Magn Reson Med ; 84(6): 3223-3233, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32767457

RESUMEN

PURPOSE: The aim of this study was to compare the wave-CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free-breathing 4D lung MRI. METHODS: The wave-CAIPI k-space trajectory was implemented in a respiratory self-gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave-CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study. RESULTS: The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave-CAIPI approach. Average normalized mutual information values of the wave-CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave-CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave-CAIPI. CONCLUSION: The application of the wave-CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave-CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Humanos , Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Estudios Retrospectivos
13.
J Biomol NMR ; 73(3-4): 155-165, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31049777

RESUMEN

Apodization weighted acquisition is a simple approach to enhance the sensitivity of multidimensional NMR spectra by scaling the number of scans during acquisition of the indirect dimension(s). The signal content of the resulting spectra is identical to conventionally sampled data, yet the spectra show improved signal-to-noise ratios. There are no special requirements for data acquisition and processing: the time-domain data can be transformed with the same schemes used for conventionally recorded spectra, including Fourier transformation. The method is of general use in multidimensional liquid and solid state NMR experiments if the number of recorded transients per sampling point is bigger than the minimum required phase cycle of the pulse sequence.


Asunto(s)
Análisis de Fourier , Espectroscopía de Resonancia Magnética , Algoritmos , Espectroscopía de Resonancia Magnética/métodos , Modelos Teóricos , Resonancia Magnética Nuclear Biomolecular/métodos
14.
BMC Med Imaging ; 19(1): 59, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31370821

RESUMEN

BACKGROUND: T1 mapping sequences such as MOLLI, ShMOLLI and SASHA make use of different technical approaches, bearing strengths and weaknesses. It is well known that obtained T1 relaxation times differ between the sequence techniques as well as between different hardware. Yet, T1 quantification is a promising tool for myocardial tissue characterization, disregarding the absence of established reference values. The purpose of this study was to evaluate the feasibility of native and post-contrast T1 mapping methods as well as ECV maps and its diagnostic benefits in a clinical environment when scanning patients with various cardiac diseases at 3 T. METHODS: Native and post-contrast T1 mapping data acquired on a 3 T full-body scanner using the three pulse sequences 5(3)3 MOLLI, ShMOLLI and SASHA in 19 patients with clinical indication for contrast enhanced MRI were compared. We analyzed global and segmental T1 relaxation times as well as respective extracellular volumes and compared the emerged differences between the used pulse sequences. RESULTS: T1 times acquired with MOLLI and ShMOLLI exhibited systematic T1 deviation compared to SASHA. Myocardial MOLLI T1 times were 19% lower and ShMOLLI T1 times 25% lower compared to SASHA. Native blood T1 times from MOLLI were 13% lower than SASHA, while post-contrast MOLLI T1-times were only 5% lower. ECV values exhibited comparably biased estimation with MOLLI and ShMOLLI compared to SASHA in good agreement with results reported in literature. Pathology-suspect segments were clearly differentiated from remote myocardium with all three sequences. CONCLUSION: Myocardial T1 mapping yields systematically biased pre- and post-contrast T1 times depending on the applied pulse sequence. Additionally calculating ECV attenuates this bias, making MOLLI, ShMOLLI and SASHA better comparable. Therefore, myocardial T1 mapping is a powerful clinical tool for classification of soft tissue abnormalities in spite of the absence of established reference values.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Volumen Cardíaco , Medios de Contraste , Estudios de Factibilidad , Cardiopatías/fisiopatología , Humanos , Sensibilidad y Especificidad
15.
BMC Pulm Med ; 19(1): 269, 2019 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-31888580

RESUMEN

BACKGROUND: Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF. METHODS: Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism. RESULTS: Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy. CONCLUSIONS: The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.


Asunto(s)
Fibrosis Quística/metabolismo , Fibrosis Quística/fisiopatología , Fuerza Muscular , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatología , Adolescente , Adulto , Estudios de Casos y Controles , Niño , Femenino , Humanos , Masculino , Músculo Esquelético/patología , Tamaño de los Órganos , Adulto Joven
16.
Magn Reson Med ; 80(5): 1979-1988, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29656510

RESUMEN

PURPOSE: To introduce and evaluate an image registration technique for robust quantification of CEST acquisitions corrupted by motion. METHODS: The proposed iterative algorithm exploits a low-rank approximation of the z-spectrum (LRAZ), to gradually separate the contrast variation due to saturation at different off-resonance frequencies and accompanying motion. This registration method was first tested in a creatine CEST analysis of a phantom with simulated rigid motion. Subsequently, creatine CEST acquisitions in the human thigh during exercise were exemplarily corrected. RESULTS: The z-spectrum obtained by applying LRAZ to the corrupted phantom series exhibited a normalized RMS error with respect to the noncorrupted gold standard series of less than 4%. The corresponding creatine map resulting from an asymmetry analysis of the registered data showed only little difference with regard to the noncorrupted determination, too. A comparable performance was observed exploiting LRAZ for the correction of nonrigid motion within the dynamic CEST acquisitions in skeletal muscles. While for the phantom simulations, high-quality registration was also possible by using a single reference image for the whole series and mutual information as similarity metric, this conventional approach resulted in inappropriate correction of the more complicated motion of the human thigh. CONCLUSION: The newly introduced method allows for a robust registration of CEST image series, which are corrupted by rigid and nonrigid motion of the investigated organ. The technique therefore improves the diagnostic value in various applications of CEST.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Ejercicio Físico/fisiología , Humanos , Movimiento/fisiología , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Fantasmas de Imagen , Muslo/diagnóstico por imagen , Muslo/fisiología
17.
Magn Reson Med ; 80(4): 1521-1532, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29479736

RESUMEN

PURPOSE: The gradient system transfer function (GSTF) has been used to describe the distorted k-space trajectory for image reconstruction. The purpose of this work was to use the GSTF to determine the pre-emphasis for an undistorted gradient output and intended k-space trajectory. METHODS: The GSTF of the MR system was determined using only standard MR hardware without special equipment such as field probes or a field camera. The GSTF was used for trajectory prediction in image reconstruction and for a gradient waveform pre-emphasis. As test sequences, a gradient-echo sequence with phase-encoding gradient modulation and a gradient-echo sequence with a spiral read-out trajectory were implemented and subsequently applied on a structural phantom and in vivo head measurements. RESULTS: Image artifacts were successfully suppressed by applying the GSTF-based pre-emphasis. Equivalent results are achieved with images acquired using GSTF-based post-correction of the trajectory as a part of image reconstruction. In contrast, the pre-emphasis approach allows reconstruction using the initially intended trajectory. CONCLUSION: The artifact suppression shown for two sequences demonstrates that the GSTF can serve for a novel pre-emphasis. A pre-emphasis based on the GSTF information can be applied to any arbitrary sequence type.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Humanos , Modelos Biológicos , Fantasmas de Imagen , Procesamiento de Señales Asistido por Computador
18.
J Magn Reson Imaging ; 48(6): 1595-1601, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29897641

RESUMEN

BACKGROUND: In its course, diabetes impairs microvascular function through endothelial dysfunction. As the response of myocardial perfusion to sympathetic stimulation through cold is modulated by endothelium-related factors, an incipient endothelial dysfunction might be observed noninvasively by investigation of myocardial perfusion with a cold pressor test (CPT). This approach has been used in clinical MRI previously. PURPOSE: To assess endothelial function of patients suffering from type 1 diabetes by MR CPT. STUDY TYPE: Prospective cohort study. SUBJECTS: Twenty type 1 diabetics and 20 healthy volunteers. FIELD STRENGTH/SEQUENCE: 3T, dynamic contrast enhanced perfusion (steady-state free precession). ASSESSMENT: Absolute quantitative myocardial perfusion values at rest and under CPT. STATISTICAL TESTS: Kolmogorov-Smirnov test to determine normal distribution of the results. T-test for independent samples. RESULTS: Patients' mean myocardial perfusion was 0.68 cc/g/min at rest and 0.80 cc/g/min during CPT, respective values of 0.81 cc/g/min and 1.36 cc/g/min were found in healthy volunteers. Perfusion values differed significantly for CPT (P < 0.01) but not for resting conditions (P = 0.06). DATA CONCLUSION: This study demonstrated that endothelial function might be impaired in type 1 diabetes patients. This fosters the thesis that endothelial function may serve as an early biomarker for coronary artery disease in patients with type 1 diabetes while these patients are still clinically asymptomatic. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;48:1595-1601.


Asunto(s)
Diabetes Mellitus Tipo 1/diagnóstico por imagen , Endotelio Vascular/fisiopatología , Imagen por Resonancia Magnética , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Frío , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Vasos Coronarios/patología , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Microcirculación , Persona de Mediana Edad , Imagen de Perfusión Miocárdica , Perfusión , Estudios Prospectivos , Adulto Joven
19.
Radiology ; 283(1): 242-251, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27715657

RESUMEN

Purpose To assess the clinical feasibility of self-gated non-contrast-enhanced functional lung (SENCEFUL) magnetic resonance (MR) imaging for quantitative ventilation (QV) imaging in patients with cystic fibrosis (CF). Materials and Methods Twenty patients with CF and 20 matched healthy volunteers underwent functional 1.5-T lung MR imaging with the SENCEFUL imaging approach, in which a two-dimensional fast low-angle shot sequence is used with quasi-random sampling. The lungs were manually segmented on the ventilation-weighted images to obtain QV measurements, which were compared between groups. QV values of the patients were correlated with results of pulmonary function testing. Three radiologists rated the images for presence of ventilation deficits by means of visual inspection. Mann-Whitney U tests, receiver operating characteristic analyses, Spearman correlations, and Gwet agreement coefficient analyses were used for statistical analysis. Results QV of the entire lungs was lower for patients with CF than for control subjects (mean ± standard deviation, 0.09 mL/mL ± 0.03 vs 0.11 mL/mL ± 0.03, respectively; P = .007). QV ratios of upper to lower lung halves were lower in patients with CF than in control subjects (right, 0.84 ± 0.2 vs 1.16 ± 0.2, respectively [P < .001]; left, 0.88 ± 0.3 vs 1.11 ± 0.1, respectively [P = .017]). Accordingly, ventilation differences between the groups were larger in the upper halves (Δ = 0.04 mL/mL, P ≤ .001-.002). QV values of patients with CF correlated with forced vital capacity (r = 0.7; 95% confidence interval [CI]: 0.21, 0.91), residual volume (static hyperinflation, r = -0.8; 95% CI: -0.94, 0.42), and forced expiratory volume in 1 second (airway obstruction, r = 0.7; 95% CI: 0.21, 0.91). Disseminated small ventilation deficits were the most frequent involvement pattern, present in 40% of the functional maps in CF versus 8% in the control subjects (P < .001). Conclusion SENCEFUL MR imaging is feasible for QV assessment. Less QV, especially in upper lung parts, and correlation to vital capacity and to markers for hyperinflation and airway obstruction were found in patients with CF. © RSNA, 2016.


Asunto(s)
Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Imagen por Resonancia Magnética/métodos , Respiración , Adolescente , Adulto , Niño , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
20.
Magn Reson Med ; 78(6): 2226-2235, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28185310

RESUMEN

PURPOSE: Banding artifacts in images acquired by balanced steady-state free precession (bSSFP) remain a challenge in MRI as they considerably reduce image quality, and diagnostic value deteriorates accordingly. As the steady-state tolerates small shifts in frequency, it is possible to acquire frequency-modulated bSSFP. Unfortunately, standard reconstructions of such measurements suffer from signal loss. Our study proposes a multifrequency reconstruction and demonstrates its capability of suppressing banding artifacts while retaining the high signal level of standard bSSFP. METHODS: Numerical simulations in vitro and in vivo measurements were performed using both standard bSSFP and frequency-modulated bSSFP. The modulated data were reconstructed using a multifrequency approach consisting of three steps: phase correction, multiple reconstructions for different assumed frequencies, and maximum intensity projection. RESULTS: Although standard bSSFP measurements showed banding artifacts that compromised the image quality, standard reconstructions of frequency-modulated acquisitions suffered from signal loss. In contrast, images reconstructed from frequency-modulated data using the proposed multifrequency reconstruction showed no visual bandings and featured a higher signal-to-noise ratio (SNR). The SNR gain for phantom and in vivo measurements ranged from 1.23 to 1.49. CONCLUSIONS: The presented multifrequency reconstruction for frequency-modulated bSSFP provides images showing no bandings and featuring high SNR in short scan times. Magn Reson Med 78:2226-2235, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Oído Interno/diagnóstico por imagen , Imagen Eco-Planar , Pierna/diagnóstico por imagen , Imagen por Resonancia Magnética , Algoritmos , Artefactos , Simulación por Computador , Análisis de Fourier , Voluntarios Sanos , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Modelos Lineales , Distribución Normal , Fantasmas de Imagen , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA