Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 86(12): 1990-1997, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36047087

RESUMEN

BACKGROUND: Balloon atrial septostomy (BAS) is an essential catheterization procedure for congenital heart lesions. Recently, a balloon catheter for static BAS was approved for the first time in Japan as an alternative to the conventional pull-through BAS. Despite the expected increase in the use of static BAS, reports on its safety are scarce worldwide.Methods and Results: Data on static and pull-through BAS registered in a national registry between 2016 and 2018 were collected. During the study period, 247 sessions of static BAS and 588 sessions of pull-through BAS were performed on a total of 674 patients. Patients who underwent static BAS were older (P<0.001). The incidence of serious adverse events (4.3% vs. 0.9%, P=0.03) and the overall incidence of adverse events (8.1% vs. 3.2%, P=0.03) were higher in static BAS than in pull-through BAS. Among patients who underwent static BAS, the risk factor for adverse events was a body weight <3 kg at the time of the procedure (odds ratio: 4.3 [confidence interval: 1.7-11], P=0.003). CONCLUSIONS: This nationwide study revealed differences in patient background between static and pull-through BAS, as well as a higher incidence of adverse events related to static BAS. Patients weighing <3 kg are at high risk for adverse events after static BAS and may require surgical and circulatory support backup.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Transposición de los Grandes Vasos , Humanos , Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo/efectos adversos , Factores de Riesgo , Oportunidad Relativa , Sistema de Registros , Transposición de los Grandes Vasos/epidemiología , Transposición de los Grandes Vasos/etiología , Transposición de los Grandes Vasos/cirugía
2.
Contact Dermatitis ; 86(3): 189-195, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34921568

RESUMEN

BACKGROUND: The Japanese baseline series (JBS), established in 1994, was updated in 2008 and 2015. The JBS 2015 is a modification of the thin-layer rapid-use epicutaneous (TRUE) test (SmartPractice Denmark, Hillerød, Denmark). No nationwide studies concerning the TRUE test have previously been reported. OBJECTIVES: To determine the prevalence of sensitizations to JBS 2015 allergens from 2015 to 2018. METHODS: We investigated JBS 2015 patch test results using the web-registered Skin Safety Care Information Network (SSCI-Net) from April 2015 to March 2019. RESULTS: Patch test results of 5865 patients were registered from 63 facilities. The five allergens with the highest positivity rates were gold sodium thiosulfate (GST; 25.7%), nickel sulfate (24.5%), urushiol (9.1%), p-phenylenediamine (PPD; 8.9%), and cobalt chloride (8.4%). The five allergens with the lowest positivity rates were mercaptobenzothiazole (0.8%), formaldehyde (0.9%), paraben mix (1.1%), mercapto mix (1.1%), and PPD black rubber mix (1.4%). CONCLUSIONS: Nickel sulfate and GST had the highest positivity rates. The JBS 2015, including a modified TRUE test, is suitable for baseline series patch testing.


Asunto(s)
Alérgenos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Pruebas del Parche/tendencias , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Conservadores Farmacéuticos/efectos adversos , Prevalencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
3.
Circ J ; 85(9): 1517-1524, 2021 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-33692248

RESUMEN

BACKGROUND: Stent implantation for vascular stenosis associated with congenital heart diseases is commonly performed as an off-label procedure in Japan because there is no officially approved stent for any congenital heart disease.Methods and Results:We analyzed data from the Japanese Society of Congenital Interventional Cardiology Registry collected from January 2016 to December 2018. Patients who underwent stent implantation were enrolled in the present analysis. During the study period, there were 470 procedures, 443 sessions, and 391 cases. Of 443 sessions, 427 (96.4%) succeeded procedurally. There were no differences in the procedural success rates among age groups. In all, 416 sessions (367 patients; 94%) resulted in survival to 30 days after catheter intervention. Of 392 admissions, 357 patients (91%) survived to discharge. Only 4 deaths were directly related to stent implantation. Some in-hospital complications were observed during 55 of 443 sessions. Both hospital deaths and serious complications were significantly more frequent in the group with various preoperative risk factors. CONCLUSIONS: Although not officially approved for congenital heart diseases in Japan, stent implantation in congenital heart diseases has been widely and routinely performed for many years with safety and efficacy. The aim of stenting was variable and broad because of many different applications and morphological variations. These data may facilitate approval of such an important device in Japan.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Humanos , Japón , Sistema de Registros , Stents/efectos adversos
4.
Graefes Arch Clin Exp Ophthalmol ; 259(9): 2849-2855, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33744981

RESUMEN

PURPOSE: To compare laser photocoagulation and intravitreal injection of bevacizumab (IVB) treatment for retinopathy of prematurity (ROP). METHODS: The study included 52 eyes of 26 patients after ROP treatment who were observed up to 5 years of age. Twenty-eight eyes received laser photocoagulation as the initial treatment (laser group), and twenty-four eyes underwent IVB (IVB group). We collected data on gestational age, birth weight, 1- and 5-min Apgar scores, zone and stage at the time of treatment, recurrence of ROP and best-corrected visual acuity (BCVA) (logMAR), equivalent spherical value (SE), ocular complications, and developmental delay at the age of 5. RESULTS: More zone I low-stage eyes were treated with IVB than laser. There was no difference in BCVA (p = 0.836). Although the mean SE was not different between the groups (p = 0.280), the prevalence of myopia was significantly higher in the laser group (p = 0.020). Developmental delay was observed in 3 of 14 and 3 of 12 cases in the laser and IVB groups, respectively (p = 0.596). Retinal holes were observed in 2 eyes in the IVB group, with 1 developing localized retinal detachment. There were no significant differences between the groups in the other factors. CONCLUSIONS: Compared to laser for ROP, IVB was not inferior in neurodevelopment or visual outcome and was superior in refractive error. As cases in the IVB group showed retinal holes, long-term follow-up with fundus examination is recommended after IVB.


Asunto(s)
Retinopatía de la Prematuridad , Inhibidores de la Angiogénesis/uso terapéutico , Bevacizumab/uso terapéutico , Edad Gestacional , Humanos , Recién Nacido , Inyecciones Intravítreas , Coagulación con Láser , Rayos Láser , Retinopatía de la Prematuridad/diagnóstico , Retinopatía de la Prematuridad/tratamiento farmacológico , Retinopatía de la Prematuridad/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Factor A de Crecimiento Endotelial Vascular
5.
Contact Dermatitis ; 2021 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-33660302

RESUMEN

BACKGROUND: There is controversy over late and long-lasting reactions to gold sodium thiosulfate (GST). OBJECTIVES: To study the GST patch-test reaction by observing the application site after 1 month, and to clarify the relevance of GST sensitization by piercings and dental metals. PATIENTS: A retrospective analysis was performed on 746 patients (143 male; 603 female) who were patch tested using GST of the TRUE Test. We conducted a questionnaire on the presence of piercings or dental metals in these patients. RESULTS: The GST positive rate was 27.9% at day (D)3 and/or D7 and 40.3% up to the 1-month reading. The positive rate was significantly higher in female patients and increased with age. Sixty-two percent of cases with a positive reaction at D7 continued to show a positive reaction after 1 month. Eleven percent of cases with a negative reaction at D3 and D7 showed a late reaction. Both piercings and dental metals were related to gold sensitization. CONCLUSIONS: The GST of the TRUE Test had a high positive and low false-negative rate. The 1-month reading after the patch test was important for identifying late reactions. Piercing history and dental metal were associated with gold sensitization.

6.
Cardiol Young ; 31(4): 644-645, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33682644

RESUMEN

This is a case of a female infant with bilateral coronary ostial atresia associated with pulmonary atresia and ventricular septal defect. She developed coronary ischemia at 1-month of age, when she underwent an aortopulmonary shunt and an aorta-right ventricle shunt. The double-orifice tricuspid valve was separating the right ventricle from the left ventricle. She required extracorporeal cardiopulmonary support because of ventricular dysfunction and mitral regurgitation. Although she was temporarily weaned off the support after mitral valvuloplasty, she died from multiple organ failure. To the best of our knowledge, bilateral coronary ostial atresia associated with pulmonary atresia with ventricular septal defect has not been reported previously.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Defectos del Tabique Interventricular , Atresia Pulmonar , Femenino , Defectos del Tabique Interventricular/cirugía , Humanos , Lactante , Arteria Pulmonar , Atresia Pulmonar/complicaciones , Atresia Pulmonar/diagnóstico , Atresia Pulmonar/cirugía , Válvula Tricúspide
7.
BMC Health Serv Res ; 20(1): 421, 2020 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-32404093

RESUMEN

BACKGROUND: The indications for general anesthesia (GA) in obstetric settings, which are determined in consideration of maternal and fetal outcome, could be affected by local patterns of clinical practice grounded in unique situations and circumstances that vary among medical institutions. Although the use of GA for cesarean delivery has become less common with more frequent adoption of neuraxial anesthesia, GA was previously chosen for pregnancy with placenta previa at our institution in case of unexpected massive hemorrhage. However, the situation has been gradually changing since formation of a team dedicated to obstetric anesthesia practice. Here, we report the results of a review of all cesarean deliveries performed under GA, and assess the impact of our newly launched team on trends in clinical obstetric anesthesia practice at our institution. METHODS: Our original database for obstetric GA during the period of 2010 to 2019 was analyzed. The medical records of all parturients who received GA for cesarean delivery were reviewed to collect detailed information. Interrupted time series analysis was used to evaluate the impact of the launch of our obstetric anesthesia team. RESULTS: As recently as 2014, more than 10% of cesarean deliveries were performed under GA, with placenta previa accounting for the main indication in elective and emergent cases. Our obstetric anesthesia team was formed in 2015 to serve as a communication bridge between the department of anesthesiology and the department of obstetrics. Since then, there has been a steady decline in the percentage of cesarean deliveries performed under GA, decreasing to a low of less than 5% in the latest 2 years. Interrupted time series analysis revealed a significant reduction in obstetric GA after 2015 (P = 0.04), which was associated with decreased use of GA for pregnancy with placenta previa. On the other hand, every year has seen a number of urgent cesarean deliveries requiring GA. CONCLUSIONS: There has been a trend towards fewer obstetric GA since 2015. The optimized use of GA for cesarean delivery was made possible mainly through strengthened partnerships between anesthesiologists and obstetricians with the support of our obstetric anesthesia team.


Asunto(s)
Anestesia General/tendencias , Anestesia Obstétrica/tendencias , Cesárea/estadística & datos numéricos , Grupo de Atención al Paciente/organización & administración , Femenino , Investigación sobre Servicios de Salud , Hospitales Universitarios , Humanos , Embarazo , Estudios Retrospectivos
8.
J Allergy Clin Immunol ; 144(5): 1354-1363, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31301374

RESUMEN

BACKGROUND: Food allergy is a growing health problem worldwide because of its increasing prevalence, life-threatening potential, and shortage of effective preventive treatments. In an outbreak of wheat allergy in Japan, thousands of patients had allergic reactions to wheat after using soap containing hydrolyzed wheat protein (HWP). OBJECTIVES: The aim of the present study was to investigate genetic variation that can contribute to susceptibility to HWP allergy. METHODS: We conducted a genome-wide association study of HWP allergy in 452 cases and 2700 control subjects using 6.6 million genotyped or imputed single nucleotide polymorphisms. Replication was assessed by genotyping single nucleotide polymorphisms in independent samples comprising 45 patients with HWP allergy and 326 control subjects. RESULTS: Through the genome-wide association study, we identified significant associations with the class II HLA region on 6p21 (P = 2.16 × 10-24 for rs9271588 and P = 2.96 × 10-24 for HLA-DQα1 amino acid position 34) and with the RBFOX1 locus at 16p13 (rs74575857, P = 8.4 × 10-9). The associations were also confirmed in the replication data set. Both amino acid polymorphisms (HLA-DQß1 amino acid positions 13 and 26) located in the P4 binding pockets on the HLA-DQ molecule achieved the genome-wide significance level (P < 5.0 × 10-8). CONCLUSIONS: Our data provide the first demonstration of genetic risk for HWP allergy and show that this genetic risk is mainly represented by multiple combinations of HLA variants.


Asunto(s)
Genotipo , Antígenos HLA-DQ/genética , Factores de Empalme de ARN/genética , Hipersensibilidad al Trigo/genética , Alérgenos/inmunología , Antígenos de Plantas/inmunología , Brotes de Enfermedades , Femenino , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Humanos , Hidrólisis , Japón/epidemiología , Masculino , Persona de Mediana Edad , Polimorfismo de Nucleótido Simple , Triticum/inmunología , Hipersensibilidad al Trigo/epidemiología
9.
Catheter Cardiovasc Interv ; 93(5): E298-E301, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30773790

RESUMEN

We report a 7-year-old male patient who developed severe atrioventricular block after transcatheter closure of the atrial septal defect with an Occlutech Figulla® Flex II ASD occluder (FSO). He had a small aortic rim and the defect measuring 22.3 mm by balloon sizing. When a 24 mm FSO was deployed, he developed Wenckebach second-degree heart block; however, it recovered to sinus rhythm. Hence, the device was implanted. The rhythm deteriorated to a fixed 2:1 heart block within 7 hr. He underwent surgical retrieval of the device and closure of the defect. Intraoperative findings demonstrated the right atrium disk compressing the triangle of Koch, resulting in a small hematoma. The rhythm recovered completely by 7 days after the surgery. Care must be taken when a relatively large device is deployed in a patient with small rims as even "soft and flexible" device like the FSO can injure the endocardium.


Asunto(s)
Bloqueo Atrioventricular/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Lesiones Cardíacas/etiología , Defectos del Tabique Interatrial/terapia , Hematoma/etiología , Dispositivo Oclusor Septal , Potenciales de Acción , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Procedimientos Quirúrgicos Cardíacos , Niño , Remoción de Dispositivos , Lesiones Cardíacas/diagnóstico , Frecuencia Cardíaca , Defectos del Tabique Interatrial/diagnóstico por imagen , Hematoma/diagnóstico , Humanos , Masculino , Diseño de Prótesis , Resultado del Tratamiento
10.
Contact Dermatitis ; 80(2): 114-117, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30198192

RESUMEN

BACKGROUND: The proportion of positive test results with gold sodium thiosulfate included in a patch test panel (P-GST) had been found to be greater than that with gold sodium thiosulfate 0.5% pet. by allergEAZE (A-GST). OBJECTIVES: To compare positive reactions to P-GST and A-GST, and to evaluate late reactions after the day (D) 7 reading. METHODS: A retrospective analysis was performed of 588 patients at participating departments (119 males; 469 females) who were patch tested with P-GST and A-GST in May 2015 to March 2016. RESULTS: Positive test reactions to P-GST and A-GST were observed in 15% and 6% of patients, respectively. Three patients reported a positive reaction occurring after the D7 reading. CONCLUSIONS: Gold sodium thiosulfate often gives a positive reaction after 2 to 3 weeks, and, in such cases, the positive reaction may be sustained, so it is recommended to assess the reaction for up to 1 month after application.


Asunto(s)
Dermatitis Alérgica por Contacto/etiología , Tiosulfato Sódico de Oro/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Pruebas del Parche , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
11.
Cardiol Young ; 29(5): 717-719, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31094309

RESUMEN

Isolation of the left innominate artery from the right aortic arch is a rare anomaly. Herein, we present an even rarer case of incomplete isolation of the proximal left innominate artery with the right aortic arch in a 3-month-old female infant with a double-outlet right ventricle and pulmonary stenosis. Surgical repair at 6 months of age was successful, leading to the restoration of adequate flow in the left arm.


Asunto(s)
Anomalías Múltiples , Aorta Torácica/anomalías , Tronco Braquiocefálico/anomalías , Ventrículo Derecho con Doble Salida/cirugía , Estenosis de la Válvula Pulmonar/etiología , Aorta Torácica/cirugía , Tronco Braquiocefálico/cirugía , Femenino , Humanos , Lactante
12.
J Hum Genet ; 63(6): 749-753, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29556033

RESUMEN

Here we report a Japanese patient with new compound heterozygous truncating variants in the PCDH12 gene. As compared to the previously reported families who had congenital microcephaly, intrauterine growth retardation, intracranial calcification, and neonatal seizure associated with dysplasia of the midbrain-hypothalamus-optic tract, the present patient showed no midbrain-hypothalamus dysplasia or congenital/postnatal microcephaly, but dyskinetic cerebral palsy and severe intellectual disability as well as multifocal epilepsy. To understand phenotypic spectrum associated with PCDH12 variants, more reports are needed.


Asunto(s)
Cadherinas/genética , Parálisis Cerebral/genética , Discinesias/genética , Epilepsia/genética , Adolescente , Anticonvulsivantes/uso terapéutico , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Parálisis Cerebral/diagnóstico por imagen , Discinesias/diagnóstico por imagen , Electroencefalografía , Epilepsia/diagnóstico por imagen , Epilepsia/tratamiento farmacológico , Heterocigoto , Humanos , Discapacidad Intelectual/diagnóstico por imagen , Discapacidad Intelectual/genética , Imagen por Resonancia Magnética , Masculino , Fenotipo , Protocadherinas
13.
Catheter Cardiovasc Interv ; 89(5): 898-905, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27416545

RESUMEN

BACKGROUND: Cardiac catheterization is often required for patients on extracorporeal membranous oxygenation (ECMO) support, though its efficacy remains unclear. This study aimed to assess the impact of catheterization on successful ECMO weaning. METHODS: This is a single-center retrospective study from 2000 to 2014. Patients with congenital heart disease who underwent cardiac catheterization while on cardiac ECMO support were included. Logistic regression analysis and Kaplan-Meier survival analysis with log-rank test were performed to determine predictors for successful weaning and patient outcome. RESULTS: Forty-nine catheterizations in 47 patients with the median age of 65 days (range: 1 day-12 years) and the median body weight of 4.2 kg (range: 1.9-32.7 kg) were included. Median duration between ECMO cannulation and catheterization was 1 day (range: 0-11 days). Thirty-three patients (70%) succeeded in decannulation and 24 patients (51%) survived to hospital discharge. Absence of renal (P = 0.045) and respiratory complications (P = 0.031) were significant prognostic factors for successful weaning in multivariate analysis. Patients who received catheterization within 48 hr after ECMO cannulation demonstrated less respiratory complications (P = 0.006) and better survival at 30 days after ECMO initiation (P = 0.039) than those who underwent later catheterization. There was no mortality; however, nine major catheterization-related complications (18%) were detected. CONCLUSION: Catheterization for pediatric patients on ECMO support can be performed, although this group contained high risk of serious adverse events. The absence of ECMO complications is a predictor for successful weaning. An earlier catheterization appears to be associated with better short-term survival in this cohort. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Oxigenación por Membrana Extracorpórea/métodos , Cardiopatías Congénitas/diagnóstico , Niño , Preescolar , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/cirugía , Mortalidad Hospitalaria/tendencias , Humanos , Lactante , Recién Nacido , Periodo Intraoperatorio , Masculino , Ontario/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
15.
Graefes Arch Clin Exp Ophthalmol ; 255(6): 1245-1250, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28236002

RESUMEN

PURPOSE: The aim of this study was to use conventional visual acuity measurements to quantify the functional visual acuity (FVA) in eyes with successfully treated amblyopia, and to compare the findings with those for contralateral normal eyes. METHODS: Nineteen patients (7 boys, 12 girls; age 7.5 ± 2.2 years) with successfully treated unilateral amblyopia and the same conventional decimal visual acuity in both eyes (better than 1.0) were enrolled. FVA, the visual maintenance ratio (VMR), maximum and minimum visual acuity, and the average response time were recorded for both eyes of all patients using an FVA measurement system. The differences in FVA values between eyes were analyzed. RESULTS: The mean LogMAR FVA scores, VMR (p < 0.001 for both), and the LogMAR maximum (p < 0.005) and minimum visual acuity (p < 0.001) were significantly poorer for the eyes with treated amblyopia than for the contralateral normal eyes. There was no significant difference in the average response time. CONCLUSIONS: Our results indicate that FVA and VMR were poorer for eyes with treated amblyopia than for normal eyes, even though the treatment for amblyopia was considered successful on the basis of conventional visual acuity measurements. These results suggest that visual function is impaired in eyes with amblyopia, regardless of treatment success, and that FVA measurements can provide highly valuable diagnosis and treatment information that is not readily provided by conventional visual acuity measurements.


Asunto(s)
Ambliopía/fisiopatología , Anteojos , Agudeza Visual , Adolescente , Ambliopía/terapia , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Proyectos Piloto , Factores de Tiempo , Resultado del Tratamiento , Pruebas de Visión/métodos
16.
J Cardiovasc Magn Reson ; 18(1): 34, 2016 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-27268132

RESUMEN

BACKGROUND: The left pulmonary artery (LPA) contributes more than the right (RPA) to total pulmonary regurgitation (PR) in patients after tetralogy of Fallot (TOF) repair, but the mechanism of this difference is not well understood. This study aimed to analyze the interplay between heart and lung size, mediastinal geometry, and differential PR. METHODS: Forty-eight Cardiovascular Magnetic Resonance (CMR) studies in patients after TOF repair were analyzed. In addition to the routine blood flow and ventricular volume quantification cardiac angle between the thoracic anterior-posterior line and the interventricular septum, right and left lung areas as well as right and left hemithorax areas were measured on an axial image. Statistical analysis was performed to compare flow parameters between RPA and LPA and to assess correlation among right ventricular volume, pulmonary blood flow parameters and lung area. RESULTS: There was no difference between LPA and RPA diameters. The LPA showed significantly less total forward flow (2.49 ± 0.87 L/min/m(2) vs 2.86 ± 0.89 L/min/m(2); p = 0.02), smaller net forward flow (1.40 ± 0.51 vs 1.89 ± 0.60 mL/min/m(2); p = <0.001), and greater regurgitant fraction (RF) (34 ± 10 % vs 43 ± 12 %; p = 0.001) than the RPA. There was no difference in regurgitant flow volume between RPA and LPA (p = 0.29). Indexed right ventricular end-diastolic volume (RVEDVi) correlated with LPA RF (R = 0.48, p < 0.001), but not with RPA RF (p = 0.09). Larger RVEDVi correlated with a more leftward cardiac axis (R = 0.46, p < 0.001) and with smaller left lung area (R = -0.58, p < 0.001). LPA RF, but not RPA RF, correlated inversely with left lung area (R = -0.34, p = 0.02). The follow-up CMRs in 20 patients showed a correlation of the rate of RV enlargement with the rates of LPA RF worsening (R = 0.50, p = 0.03), and of increasing left lung compression (R = -0.55, p = 0.012). CONCLUSION: An enlarged and levorotated heart is associated with left lung compression and impaired flow into the left lung.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hemodinámica , Hipertrofia Ventricular Derecha/etiología , Arteria Pulmonar/fisiopatología , Circulación Pulmonar , Insuficiencia de la Válvula Pulmonar/etiología , Tetralogía de Fallot/cirugía , Función Ventricular Derecha , Adolescente , Velocidad del Flujo Sanguíneo , Niño , Femenino , Humanos , Hipertrofia Ventricular Derecha/diagnóstico por imagen , Hipertrofia Ventricular Derecha/fisiopatología , Imagen por Resonancia Cinemagnética , Masculino , Arteria Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Tetralogía de Fallot/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
18.
J Med Ultrason (2001) ; 40(2): 157-62, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27277106

RESUMEN

A pregnant Japanese female was referred to our hospital due to intrauterine fetal growth restriction. A prenatal diagnosis of right pulmonary agenesis could be made using ultrasonography and fetal magnetic resonance imaging, and a Caesarian section was performed at 34 weeks of gestation. The infant developed a respiratory disorder immediately, received systemic management in the neonatal intensive care unit (NICU), and was discharged at age of 103 days without any severe sequelae.

19.
J Cardiol Cases ; 26(2): 144-147, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35949569

RESUMEN

Total extrusion of a pacemaker is rare and may result from skin and/or pocket infection or skin erosion because of fragility caused by actions such as scratching an itch. Total extrusion of a pacemaker may cause fatal arrhythmias, exacerbation of heart failure, and infection. We report the case of a 37-year-old man with a pacemaker implanted for complete atrioventricular block who presented with exacerbation of advanced heart failure due to complete extrusion of the pacemaker from the left groin and pacing failure. No fever was observed during the clinical course, but exudate leaked from his abdominal pocket. Electrocardiography showed a complete atrioventricular block. He successfully underwent implantation of a new pacemaker. Learning objective: There are various complications related to permanent pacemaker implantation; however, total extrusion, which is extremely rare, can lead to pacemaker failure, sepsis, and life-threatening arrhythmias. It is essential not only to check the pacemaker pocket and generator but also to educate patients on the importance of pacemaker check-ups and problems.

20.
J Cardiol Cases ; 25(3): 126-129, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35261693

RESUMEN

Given the rarity of significant first-degree atrioventricular block (AVB) after Occlutech Figulla Flex II atrial septal defect occluder (OFF II, Occlutech International AB, Helsingborg, Sweden) placement, its management and predictors of recovery have not been established. We report a 9-year-old boy who developed significant first-degree AVB a day after OFF II deployment. Thereafter, oral prednisolone was initiated at 1.5 mg/kg/day. On day 2 of steroid treatment, normal sinus rhythm without conduction delays was occasionally observed, while the prolonged PR interval on the exercise stress test was ameliorated. After 5 days of steroid administration, normal sinus rhythm without conduction delays was completely achieved. An increase in the frequency of normal sinus rhythm and the absence of conduction delays on electrocardiogram monitoring and exercise stress test play an important role in predicting recovery from prolonged PR interval. Thus, steroid treatment can be effective and should be considered for patients who develop first-degree AVB after undergoing OFF II placement for transcatheter device closure of atrial septal defect. .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA