Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 101(4): 813-816, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36740232

RESUMEN

A 67-year-old male patient was admitted with an enormous twisted thoracoabdominal aortic aneurysm (TAAA) with multiple branch arteries stenosis and occlusion. Three-dimensional (3D) printing technology combined with mechanics was used for developing a transparent model of lesion to simulate the segment of diseased aorta. A stent graft was deployed in the 3D model to make a physician-modified stent graft (PMSGs) on table. The locations of the opening of branches were marked twice during operation. The PMSG was successfully deployed during the surgery and repaired the TAAA, with no endoleak and all the branched arteries patency in follow-up. This technique could offer precision individualized therapy and could simplify the procedure process greatly.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Stents , Aneurisma de la Aorta Torácica/cirugía , Constricción Patológica , Resultado del Tratamiento , Diseño de Prótesis , Impresión Tridimensional , Procedimientos Endovasculares/métodos , Estudios Retrospectivos
2.
J Card Surg ; 37(11): 3955-3957, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35930597

RESUMEN

A 69-year-old male patient was admitted by 10 h severe chest pain. Computed tomography angiography showed a 7.3 cm aneurysm of the aortic arch. We used a three-dimensional parametric surface planar topological guide plate to prepare a guide plate in 40 min. The plate was used to localize the opening of the aortic arch branches on table to create a physician-modified stent graft (PMSG). The aneurysm was successfully repaired by the triple inner branched PMSG, with no endoleak and all the branched arteries patency in follow-up. This technique could not only make accurate fenestration but also meet the need for emergency surgery.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Anciano , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Masculino , Diseño de Prótesis , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA