Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 288
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
2.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38795719

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
3.
Nano Lett ; 24(14): 4233-4240, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38557069

RESUMEN

This study represents the synthesis of a novel class of nanoparticles denoted as annular Au nanotrenches (AANTs). AANTs are engineered to possess embedded, narrow circular nanogaps with dimensions of approximately 1 nm, facilitating near-field focusing for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) via a surface-enhanced Raman scattering (SERS)-based immunoassay. Notably, AANTs exhibited an exceedingly low limit of detection (LOD) of 1 fg/mL for SARS-CoV-2 spike glycoproteins, surpassing the commercially available enzyme-linked immunosorbent assay (ELISA) by 6 orders of magnitude (1 ng/mL from ELISA). To assess the real-world applicability, a study was conducted on 50 clinical samples using an SERS-based immunoassay with AANTs. The results revealed a sensitivity of 96% and a selectivity of 100%, demonstrating the significantly enhanced sensing capabilities of the proposed approach in comparison to ELISA and commercial lateral flow assay kits.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , SARS-CoV-2 , Oro , COVID-19/diagnóstico , Inmunoensayo/métodos , Espectrometría Raman/métodos
4.
Emerg Infect Dis ; 30(4): 817-821, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38526320

RESUMEN

Orthohantaviruses cause hantavirus cardiopulmonary syndrome; most cases occur in the southwest region of the United States. We discuss a clinical case of orthohantavirus infection in a 65-year-old woman in Michigan and the phylogeographic link of partial viral fragments from the patient and rodents captured near the presumed site of infection.


Asunto(s)
Infecciones por Hantavirus , Orthohantavirus , Femenino , Humanos , Anciano , Michigan/epidemiología , Filogeografía , Síndrome
5.
Bioinformatics ; 39(5)2023 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-37129547

RESUMEN

Detection and analysis of viral genomes with Nanopore sequencing has shown great promise in the surveillance of pathogen outbreaks. However, the number of virus detection pipelines supporting Nanopore sequencing is very limited. Here, we present VirPipe, a new pipeline for the detection of viral genomes from Nanopore or Illumina sequencing input featuring streamlined installation and customization. AVAILABILITY AND IMPLEMENTATION: VirPipe source code and documentation are freely available for download at https://github.com/KijinKims/VirPipe, implemented in Python and Nextflow.


Asunto(s)
Secuenciación de Nanoporos , Nanoporos , Programas Informáticos , Genoma Viral , Secuenciación de Nucleótidos de Alto Rendimiento
6.
J Med Virol ; 96(1): e29401, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38235603

RESUMEN

Hepatitis E virus (HEV), an emerging zoonotic pathogen, poses a significant public health concern worldwide. Recently, rat HEV (Rocahepevirus ratti genotype C1; HEV-C1) has been reported to cause zoonotic infections and hepatitis in humans. Human infections with HEV-C1 are considered to be underestimated worldwide due to limited knowledge of transmission routes, genome epidemiology, and the risk assessment of zoonosis associated with these viruses. A total of 186 wild Norway rats (Rattus norvegicus) were collected from the Republic of Korea (ROK) between 2011 and 2021. The prevalence of HEV-C1 RNA was 8 of 180 (4.4%) by reverse-transcription polymerase chain reaction. We first reported three nearly whole-genome sequences of HEV-C1 newly acquired from urban rats in the ROK. Phylogenetic analysis demonstrated that Korea-indigenous HEV-C1 formed an independent genetic group with those derived from R. norvegicus rats in other countries, indicating geographical and genetic diversity. Our findings provide critical insights into the molecular prevalence, genome epidemiology, and zoonotic potential of Rocahepevirus. This report raises awareness of the presence of Rocahepevirus-related hepatitis E among physicians in the ROK.


Asunto(s)
Virus de la Hepatitis E , Hepatitis E , Animales , Ratas , Humanos , Virus de la Hepatitis E/genética , Filogenia , Hepatitis E/epidemiología , Hepatitis E/veterinaria , Zoonosis , ARN Viral/genética , República de Corea/epidemiología
7.
J Med Virol ; 96(1): e29346, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38178580

RESUMEN

Orthohantaviruses, etiological agents of hemorrhagic fever with renal syndrome (HFRS) and hantavirus cardiopulmonary syndrome, pose a critical public health threat worldwide. Hantaan orthohantavirus (HTNV) outbreaks are particularly endemic in Gyeonggi Province in northern area of the Republic of Korea (ROK). Small mammals were collected from three regions in the Gyeonggi Province during 2017 and 2018. Serological and molecular prevalence of HTNV was 25/201 (12.4%) and 10/25 (40%), respectively. A novel nanopore-based diagnostic assay using a cost-efficient Flongle chip was developed to rapidly and sensitively detect HTNV infection in rodent specimens within 3 h. A rapid phylogeographical surveillance of HTNV at high-resolution phylogeny was established using the amplicon-based Flongle sequencing. In total, seven whole-genome sequences of HTNV were newly obtained from wild rodents collected in Paju-si (Gaekhyeon-ri) and Yeoncheon-gun (Hyeonga-ri and Wangnim-ri), Gyeonggi Province. Phylogenetic analyses revealed well-supported evolutionary divergence and genetic diversity, enhancing the resolution of the phylogeographic map of orthohantaviruses in the ROK. Incongruences in phylogenetic patterns were identified among HTNV tripartite genomes, suggesting differential evolution for each segment. These findings provide crucial insights into on-site diagnostics, genome-based surveillance, and the evolutionary dynamics of orthohantaviruses to mitigate hantaviral outbreaks in HFRS-endemic areas in the ROK.


Asunto(s)
Virus Hantaan , Fiebre Hemorrágica con Síndrome Renal , Orthohantavirus , Animales , Filogenia , Virus Hantaan/genética , Orthohantavirus/genética , Roedores , Mamíferos , República de Corea/epidemiología
8.
Artículo en Inglés | MEDLINE | ID: mdl-38860614

RESUMEN

BACKGROUND: Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce. METHODS: A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations. RESULTS: Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients ( ≥ $\ge $ 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation ( > $\gt $ mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar. CONCLUSION: Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38764320

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.

10.
Biomarkers ; 29(4): 205-210, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588595

RESUMEN

BACKGROUND: Currently available risk scores fail to accurately predict morbidity and mortality in patients with severe symptomatic aortic stenosis who undergo transcatheter aortic valve implantation (TAVI). In this context, biomarkers like matrix metalloproteinase-2 (MMP-2) and Galectin-3 (Gal-3) may provide additional prognostic information. METHODS: Patients with severe aortic stenosis undergoing consecutive, elective, transfemoral TAVI were included. Baseline demographic data, functional status, echocardiographic findings, clinical outcomes and biomarker levels were collected and analysed. RESULTS: The study cohort consisted of 89 patients (age 80.4 ± 5.1 years, EuroScore II 7.1 ± 5.8%). During a median follow-up period of 526 d, 28 patients (31.4%) died. Among those who died, median baseline MMP-2 (alive: 221.6 [170.4; 263] pg/mL vs. deceased: 272.1 [225; 308.8] pg/mL, p < 0.001) and Gal-3 levels (alive: 19.1 [13.5; 24.6] pg/mL vs. deceased: 25 [17.6; 29.5] pg/mL, p = 0.006) were higher than in survivors. In ROC analysis, MMP-2 reached an acceptable level of discrimination to predict mortality (AUC 0.733, 95% CI [0.62; 0.83], p < 0.001), but the predictive value of Gal-3 was poor (AUC 0.677, 95% CI [0.56; 0.79], p = 0.002). Kaplan-Meier and Cox regression analyses showed that patients with MMP-2 and Gal-3 concentrations above the median at baseline had significantly impaired long-term survival (p = 0.004 and p = 0.02, respectively). CONCLUSIONS: In patients with severe aortic stenosis undergoing transfemoral TAVI, MMP-2 and to a lesser extent Gal-3, seem to have additive value in optimizing risk prediction and streamlining decision-making.


Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Galectina 3 , Metaloproteinasa 2 de la Matriz , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Metaloproteinasa 2 de la Matriz/sangre , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Biomarcadores/sangre , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/sangre , Galectina 3/sangre , Anciano de 80 o más Años , Anciano , Pronóstico , Galectinas , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/metabolismo
11.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750455

RESUMEN

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Asunto(s)
Tejido Adiposo , Estenosis de la Válvula Aórtica , Angiografía Coronaria , Circulación Coronaria , Pericardio , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Masculino , Estudios Retrospectivos , Pericardio/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/fisiopatología , Anciano de 80 o más Años , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Angiografía por Tomografía Computarizada , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Tejido Adiposo Epicárdico
12.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-36883599

RESUMEN

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía
13.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36331961

RESUMEN

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Incidencia , Factores de Riesgo , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Ecocardiografía
14.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31733182

RESUMEN

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Asunto(s)
Válvula Aórtica/fisiopatología , Aspirina/farmacología , Clopidogrel/farmacología , Inhibidores del Factor Xa/farmacología , Prótesis Valvulares Cardíacas , Inhibidores de Agregación Plaquetaria/farmacología , Rivaroxabán/farmacología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/efectos de los fármacos , Válvula Aórtica/patología , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Clopidogrel/uso terapéutico , Quimioterapia Combinada , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Femenino , Tomografía Computarizada Cuatridimensional , Hemorragia/inducido químicamente , Humanos , Análisis de Intención de Tratar , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Rivaroxabán/efectos adversos , Rivaroxabán/uso terapéutico , Tromboembolia/etiología , Tromboembolia/mortalidad
15.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37694603

RESUMEN

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
16.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668097

RESUMEN

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Mar Drugs ; 21(7)2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37504900

RESUMEN

Microalgae are proposed to have powerful applications for human health in the pharmaceutical and food industries. Tetraselmis species (sp.), which are green microalgae, were identified as a source of broad-spectrum health-promoting biological activities. However, the bioactivity of these species has not been elucidated. We aimed to confirm the antioxidant, antiviral, and anti-inflammatory effects of Tetraselmis sp. extract (TEE). TEE showed 2,2-diphenyl-1-picryl-hydrazyl-hydrate radical and hydrogen peroxide scavenging activities and reduced plaque formation in Vero E6 cells infected with vaccinia virus. TEE treatment also significantly inhibited nitric oxide (NO) production and improved cell viability in lipopolysaccharide (LPS)-induced RAW264.7 cells. These anti-inflammatory effects were further analyzed in LPS-induced RAW 264.7 cells and the zebrafish model. Further, TEE reduced induced NO synthase expression and proinflammatory cytokine release, including tumor necrosis factor-α, interleukin-6, and interleukin-1ß, through MAPKs and NF-κB-dependent mechanisms. Further analysis revealed that TEE increased the survival rate and reduced cell death and NO production in an LPS-stimulated zebrafish model. Further, high-performance liquid chromatography revealed a strong presence of the carotenoid lutein in TEE. Overall, the results suggest that lutein-enriched TEE may be a potent antioxidant, antiviral, and anti-inflammatory agent that could be sustainably utilized in industrial applications.


Asunto(s)
Antioxidantes , Luteína , Animales , Ratones , Humanos , Antioxidantes/farmacología , Luteína/farmacología , Luteína/metabolismo , Pez Cebra/metabolismo , Lipopolisacáridos/farmacología , Antivirales/farmacología , Extractos Vegetales/farmacología , Extractos Vegetales/química , Antiinflamatorios/farmacología , FN-kappa B/metabolismo , Células RAW 264.7 , Óxido Nítrico/metabolismo , Óxido Nítrico Sintasa de Tipo II/metabolismo
18.
Int J Mol Sci ; 24(24)2023 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-38139128

RESUMEN

Influenza viruses cause severe endemic respiratory infections in both humans and animals worldwide. The emergence of drug-resistant viral strains requires the development of new influenza therapeutics. Tabamide A (TA0), a phenolic compound isolated from tobacco leaves, is known to have antiviral activity. We investigated whether synthetic TA0 and its derivatives exhibit anti-influenza virus activity. Analysis of structure-activity relationship revealed that two hydroxyl groups and a double bond between C7 and C8 in TA0 are crucial for maintaining its antiviral action. Among its derivatives, TA25 showed seven-fold higher activity than TA0. Administration of TA0 or TA25 effectively increased survival rate and reduced weight loss of virus-infected mice. TA25 appears to act early in the viral infection cycle by inhibiting viral mRNA synthesis on the template-negative strand. Thus, the anti-influenza virus activity of TA0 can be expanded by application of its synthetic derivatives, which may aid in the development of novel antiviral therapeutics.


Asunto(s)
Gripe Humana , Orthomyxoviridae , Virus , Humanos , Animales , Ratones , Antivirales/farmacología , Antivirales/uso terapéutico , Antivirales/química , Gripe Humana/tratamiento farmacológico , Replicación Viral
19.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
20.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA