1.
Europace ; 23(1): 113-122, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33257952

RESUMEN

AIMS: To assess and compare long-term mortality and predictors thereof in de novo cardiac resynchronization therapy defibrillators (CRT-D) vs. upgrade from an implantable cardioverter-defibrillator (ICD) to CRT-D. METHODS AND RESULTS: Study population consisted of 595 consecutive patients with CRT-D implanted between 2002 and 2015 in a tertiary care, university hospital, in a densely inhabited, urban region of Poland [480 subjects (84.3%) with CRT-D de novo implantation; 115 patients (15.7%) upgraded from ICD to CRT-D]. In a median observation of 1692 days (range 457-3067), all-cause mortality for de novo CRT-D vs. CRT-D upgrade was 35.5% vs. 43.5%, respectively (P = 0.045). On multivariable regression analysis including all CRT recipients, the previously implanted ICD was an independent predictor for death [hazard ratio (HR) 1.58, 95% confidence interval (CI) 1.10-2.29, P = 0.02]. For those, who were upgraded from ICD to CRT-D, the independent predictors for all-cause death were as follows: creatinine level (HR 1.01, 95% CI 1.00-1.02, P = 0.01), left ventricular end-systolic diameter (HR 1.07, 95% CI 1.02-1.11, P = 0.002), New York Heart Association (NYHA) IV class at baseline (HR 2.36, 95% CI 1.00-5.53, P = 0.049) and cardiac device-related infective endocarditis during follow-up (HR 2.42, 95% CI 1.02-5.75, P = 0.046). A new CRT scale (Creatinine ≥150 µmol/L; Remodelling, left ventricular end-systolic ≥59 mm; Threshold for NYHA, NYHA = IV) showed high prediction for mortality in CRT-D upgrades (AUC 0.70, 95% CI 0.59-0.80, P = 0.0007). CONCLUSION: All-cause mortality in patients upgraded from ICD is significantly higher compared with de novo CRT-D implantations and reaches almost 45% within 4.5 years. A new CRT scale (Creatinine; Remodelling; Threshold for NYHA) has been proposed to help survival prediction following CRT upgrade.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Polonia , Resultado del Tratamiento
2.
J Electrocardiol ; 51(6): 1015-1018, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30497722

RESUMEN

Patients with a single ventricle have complex anatomy that requires staged palliation which is usually the Fontan procedure. This procedure has undergone a lot of modifications to improve hemodynamics. Despite these efforts, sinus node dysfunction (SND) and bradyarrythmias are still common complications after Fontan operation, therefore there is a need of pacemakers implantation. Unfortunately, the most frequent technique of creating Fontan cannale - the extracardiac lateral tunnel makes the transvenous access to the atrium difficult or impossible to achieve. We report a case of successful implantation of an endocardial atrial lead for SND in patient with an extracardiac autologous Fontan tunnel.


Asunto(s)
Bradicardia/terapia , Procedimiento de Fontan , Cardiopatías Congénitas/cirugía , Marcapaso Artificial , Complicaciones Posoperatorias/terapia , Síndrome del Seno Enfermo/terapia , Bradicardia/diagnóstico , Niño , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Complicaciones Posoperatorias/diagnóstico , Síndrome del Seno Enfermo/diagnóstico
3.
Artículo en Inglés | MEDLINE | ID: mdl-36612708

RESUMEN

There are reports documenting that electromagnetic waves generated by deep brain stimulation devices can interfere with cardiac pacemakers. This might be even a life-threatening problem in cardiac pacemaker-dependent patients. Herein, we present a case report on a patient with bilaterally implanted deep brain stimulation devices, who concomitantly had the indications for permanent cardiac pacing. The report shows that a leadless AV pacemaker may be a safe and reasonable option in these cases.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Prótesis e Implantes , Encéfalo , Diseño de Equipo