Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 91(6): 4092-4099, 2019 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-30807105

RESUMEN

Quantitation of the serum concentration of 25-hydroxyvitamin D is a high-demand assay that suffers from long chromatography time to separate 25-hydroxyvitamin D from its inactive epimer; however, ion mobility spectrometry can distinguish the epimer pair in under 30 ms due to the presence of a unique extended or "open" gas-phase sodiated conformer, not shared with the epimer, reducing the need for chromatographic separation. Five ion mobility mass spectrometers utilizing commercially available IMS technologies, including drift tube, traveling wave, trapped, and high-field asymmetric ion mobility spectrometry, are evaluated for their ability to resolve the unique open conformer. Additionally, settings for each instrument are evaluated to understand their influence on ion heating, which can drive the open conformer into a compact or "closed" conformer shared with the epimer. The four low-field instruments successfully resolved the open conformer from the closed conformer at baseline or near-baseline resolution at typical operating parameters. High-field asymmetric ion mobility was unable to resolve a unique peak but detected two peaks for the epimer, in contrast to the low-field methods that detected one conformer. This study seeks to expand the instrument space by highlighting the potential of each platform for the separation of 25-hydroxyvitamin D epimers.


Asunto(s)
Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masas/métodos , Vitamina D/análogos & derivados , Bioensayo , Humanos , Conformación Molecular , Vitamina D/análisis , Vitamina D/química
2.
Rapid Commun Mass Spectrom ; 33 Suppl 2: 3-10, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30772932

RESUMEN

RATIONALE: Atmospheric pressure drift tube ion mobility is a powerful addition to the Orbitrap mass spectrometer enabling direct separation of isomers. Apart from offering high resolving power in a compact design, it also facilitates optimization of the separation gas, as shown here for a series of biologically relevant isomer pairs. METHODS: An Excellims MA3100 High-Resolution Atmospheric Pressure Ion Mobility Spectrometer (HR-IMS) was coupled to a Thermo Scientific™ Q Exactive™ Focus hybrid quadrupole-Orbitrap™ mass spectrometer, using an Excellims Directspray™ Electrospray Ionization source and a gas mixture setup to provide various drift gases (air, CO2 and mixtures). This instrument combination was used to separate isomers of eight pairs of metabolites and gangliosides, optimizing drift gas conditions for best separation of each set. RESULTS: All but one of the isomers pairs provided could be partially or fully separated by the HR-IMS-MS combination using ion mobility drift times. About half of the separated compounds showed significantly better analytical separation when analyzed in a mixture of CO2 and air rather than air or CO2 alone. Resolving power of up to 102 was achieved using the 10 cm atmospheric drift tube ion mobility add-on for the Orbitrap mass spectrometer. CONCLUSIONS: The present analysis demonstrates the usefulness of using atmospheric drift tube IMS on an Orbitrap mass spectrometer to characterize the isomeric composition of samples. It also highlights the potential benefits of being able to quickly optimize the drift gas composition to selectively maximize the mobility difference for isomer separation.


Asunto(s)
Dióxido de Carbono/química , Gangliósidos/química , Gases/química , Espectrometría de Masas/métodos , Aire/análisis , Isomerismo , Espectrometría de Masas/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA