Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Heart Fail Rev ; 29(1): 227-234, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37950833

RESUMEN

As the survival after heart transplantation (HTx) is steadily improving, an increasing number of patients with late cardiac pathologies such as valvular disease is expected to rise. Nevertheless, no guidelines for indication of redo cardiac surgery after HTx exists. The aim of the present systematic review is to describe the results reported in the literature of surgical management of severe aortic and/or mitral valve disease. A systematic review was conducted including studies reporting on adult patients with severe mitral or aortic valve pathology needing surgery after their previous HTx. Exclusion criteria consisted in surgery with no left heart valve surgery, concomitant valve surgery during heart transplant, transcatheter interventions, and heterotopic HTx. A total of 35 papers met our inclusion criteria out of 2755 potentially eligible studies with 44 mitral valve surgery patients and 20 aortic valve surgery patients. In the entire population, the mean time from HTx to reintervention was 6.19 ± 5.22 years. After a mean follow-up of 2.78 ± 3.54 years and 1.53 ± 2.26 years from reintervention, 65.6% mitral and 86.7% aortic patients were reported as alive, respectively. As guidelines on cardiac surgery after HTx are currently lacking, left-sided valvular cardiac reinterventions can be considered a possible therapeutic approach in carefully selected patients. These interventions may not only improve the patient's functional status and survival, but may ultimately reduce the need for re-transplantation due to the chronic shortage of donor hearts. However, the support of more robust data is warranted.


Asunto(s)
Cardiopatías , Trasplante de Corazón , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Donantes de Tejidos , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
2.
Heart Fail Rev ; 29(1): 219-226, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37851119

RESUMEN

Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.


Asunto(s)
Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Persona de Mediana Edad , Femenino , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Trasplante de Corazón/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos
3.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
J Cardiovasc Magn Reson ; 25(1): 78, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38093273

RESUMEN

BACKGROUND: While the microstructure of the left ventricle (LV) has been largely described, only a few studies investigated the right ventricular insertion point (RVIP). It was accepted that the aggregate cardiomyocytes organization was much more complex due to the intersection of the ventricular cavities but a precise structural characterization in the human heart was lacking even if clinical phenotypes related to right ventricular wall stress or arrhythmia were observed in this region. METHODS: MRI-derived anatomical imaging (150 µm3) and diffusion tensor imaging (600 µm3) were performed in large mammalian whole hearts (human: N = 5, sheep: N = 5). Fractional anisotropy, aggregate cardiomyocytes orientations and tractography were compared within both species. Aggregate cardiomyocytes orientation on one ex-vivo sheep whole heart was then computed using structure tensor imaging (STI) from 21 µm isotropic acquisition acquired with micro computed tomography (MicroCT) imaging. Macroscopic and histological examination were performed. Lastly, experimental cardiomyocytes orientation distribution was then compared to the usual rule-based model using electrophysiological (EP) modeling. Electrical activity was modeled with the monodomain formulation. RESULTS: The RVIP at the level of the inferior ventricular septum presented a unique arrangement of aggregate cardiomyocytes. An abrupt, mid-myocardial change in cardiomyocytes orientation was observed, delimiting a triangle-shaped region, present in both sheep and human hearts. FA's histogram distribution (mean ± std: 0.29 ± 0.06) of the identified region as well as the main dimension (22.2 mm ± 5.6 mm) was found homogeneous across samples and species. Averaged volume is 0.34 cm3 ± 0.15 cm3. Both local activation time (LAT) and morphology of pseudo-ECGs were strongly impacted with delayed LAT and change in peak-to-peak amplitude in the simulated wedge model. CONCLUSION: The study was the first to describe the 3D cardiomyocytes architecture of the basal inferoseptal left ventricle region in human hearts and identify the presence of a well-organized aggregate cardiomyocytes arrangement and cardiac structural discontinuities. The results might offer a better appreciation of clinical phenotypes like RVIP-late gadolinium enhancement or uncommon idiopathic ventricular arrhythmias (VA) originating from this region.


Asunto(s)
Imagen de Difusión Tensora , Ventrículos Cardíacos , Humanos , Animales , Ovinos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Medios de Contraste , Microtomografía por Rayos X , Valor Predictivo de las Pruebas , Gadolinio , Miocitos Cardíacos/fisiología , Arritmias Cardíacas , Mamíferos
5.
Eur Heart J ; 43(12): 1234-1247, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35134898

RESUMEN

AIMS: Mapping data of human ventricular fibrillation (VF) are limited. We performed detailed mapping of the activities underlying the onset of VF and targeted ablation in patients with structural cardiac abnormalities. METHODS AND RESULTS: We evaluated 54 patients (50 ± 16 years) with VF in the setting of ischaemic (n = 15), hypertrophic (n = 8) or dilated cardiomyopathy (n = 12), or Brugada syndrome (n = 19). Ventricular fibrillation was mapped using body-surface mapping to identify driver (reentrant and focal) areas and invasive Purkinje mapping. Purkinje drivers were defined as Purkinje activities faster than the local ventricular rate. Structural substrate was delineated by electrogram criteria and by imaging. Catheter ablation was performed in 41 patients with recurrent VF. Sixty-one episodes of spontaneous (n = 10) or induced (n = 51) VF were mapped. Ventricular fibrillation was organized for the initial 5.0 ± 3.4 s, exhibiting large wavefronts with similar cycle lengths (CLs) across both ventricles (197 ± 23 vs. 196 ± 22 ms, P = 0.9). Most drivers (81%) originated from areas associated with the structural substrate. The Purkinje system was implicated as a trigger or driver in 43% of patients with cardiomyopathy. The transition to disorganized VF was associated with the acceleration of initial reentrant activities (CL shortening from 187 ± 17 to 175 ± 20 ms, P < 0.001), then spatial dissemination of drivers. Purkinje and substrate ablation resulted in the reduction of VF recurrences from a pre-procedural median of seven episodes [interquartile range (IQR) 4-16] to 0 episode (IQR 0-2) (P < 0.001) at 56 ± 30 months. CONCLUSIONS: The onset of human VF is sustained by activities originating from Purkinje and structural substrate, before spreading throughout the ventricles to establish disorganized VF. Targeted ablation results in effective reduction of VF burden. KEY QUESTION: The initial phase of human ventricular fibrillation (VF) is critical as it involves the primary activities leading to sustained VF and arrhythmic sudden death. The origin of such activities is unknown. KEY FINDING: Body-surface mapping shows that most drivers (≈80%) during the initial VF phase originate from electrophysiologically defined structural substrates. Repetitive Purkinje activities can be elicited by programmed stimulation and are implicated as drivers in 37% of cardiomyopathy patients. TAKE-HOME MESSAGE: The onset of human VF is mostly associated with activities from the Purkinje network and structural substrate, before spreading throughout the ventricles to establish sustained VF. Targeted ablation reduces or eliminates VF recurrence.


Asunto(s)
Síndrome de Brugada , Ablación por Catéter , Mapeo del Potencial de Superficie Corporal , Ablación por Catéter/métodos , Electrocardiografía , Ventrículos Cardíacos , Humanos , Fibrilación Ventricular
6.
Am J Physiol Heart Circ Physiol ; 322(6): H936-H952, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35302879

RESUMEN

Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this article, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identified a dual-layer organization of the fiber orientation in the intraventricular septum of ex vivo sheep hearts using diffusion tensor imaging at high field MRI. To expand the scope of the results, we investigated the presence of a similar fiber organization in five mammalian species (rat, canine, pig, sheep, and human) and highlighted the continuity of the layer with the moderator band in large mammalian species. We implemented the measured septal fiber fields in three-dimensional electromechanical computer models to assess the impact of the fiber orientation. The downward fibers produced a diamond activation pattern superficially in the right ventricle. Electromechanically, there was very little change in pressure volume loops although the stress distribution was altered. In conclusion, we clarified that the right ventricular septum has a downwardly directed superficial layer in larger mammalian species, which can have modest effects on stress distribution.NEW & NOTEWORTHY A dual-layer organization of the fiber orientation in the intraventricular septum was identified in ex vivo hearts of large mammals. The RV septum has a downwardly directed superficial layer that is continuous with the moderator band. Electrically, it produced a diamond activation pattern. Electromechanically, little change in pressure volume loops were noticed but stress distribution was altered. Fiber distribution derived from diffusion tensor imaging should be considered for an accurate strain and stress analysis.


Asunto(s)
Imagen de Difusión Tensora , Tabique Interventricular , Animales , Diamante , Perros , Ventrículos Cardíacos , Mamíferos , Miocardio , Ratas , Ovinos , Porcinos , Tabique Interventricular/diagnóstico por imagen
7.
J Card Surg ; 37(9): 2633-2639, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35598309

RESUMEN

OBJECTIVES: The hypothermic circulatory arrest is a major limitation of the frozen elephant trunk (FET) technique, associated with a high incidence of postoperative mobility and mortality. The aim of this study was to evaluate the surgical outcomes of patients suffering from different aortic arch diseases treated with the release and perfuse technique (RPT). METHODS: We retrospectively reviewed the records of patients who had undergone aortic arch repair with the RPT at our Institution between October 2019 and September 2021. Preoperative, intra-operative, and postoperative data were collected. RESULTS: A total of 18 patients undergoing aortic arch surgery with the use of RPT were analyzed. Twelve of them (67%) were males, and the median age of the entire cohort was 67 (56-73) years. The primary indications for surgery included acute type A aortic dissection (50%), chronic type B aortic dissection (33%), and chronic aneurysms (17%). The median cardiopulmonary bypass-, aortic cross-clamp- and circulatory arrest times were 163 (147-213) min, 69 (51-120) min, and 10 (8-13) min, respectively. The median intensive care unit and hospital stay were 4 (2-7) and 12 (11-16) days, respectively. One patient (6%) died during the first 30 days after surgery. CONCLUSIONS: Considering the anatomical limitations related to the use of this technique, the RPT can be safely performed and could represent a promising strategy to reduce the circulatory arrest time during aortic arch surgery. Nevertheless, further studies are required to demonstrate its efficacy.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Disección Aórtica , Implantación de Prótesis Vascular , Anciano , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Cardiovasc Magn Reson ; 23(1): 119, 2021 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-34670572

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance T1ρ mapping may detect myocardial injuries without exogenous contrast agent. However, multiple co-registered acquisitions are required, and the lack of robust motion correction limits its clinical translation. We introduce a single breath-hold myocardial T1ρ mapping method that includes model-based non-rigid motion correction. METHODS: A single-shot electrocardiogram (ECG)-triggered balanced steady state free precession (bSSFP) 2D adiabatic T1ρ mapping sequence that collects five T1ρ-weighted (T1ρw) images with different spin lock times within a single breath-hold is proposed. To address the problem of residual respiratory motion, a unified optimization framework consisting of a joint T1ρ fitting and model-based non-rigid motion correction algorithm, insensitive to contrast change, was implemented inline for fast (~ 30 s) and direct visualization of T1ρ maps. The proposed reconstruction was optimized on an ex vivo human heart placed on a motion-controlled platform. The technique was then tested in 8 healthy subjects and validated in 30 patients with suspected myocardial injury on a 1.5T CMR scanner. The Dice similarity coefficient (DSC) and maximum perpendicular distance (MPD) were used to quantify motion and evaluate motion correction. The quality of T1ρ maps was scored. In patients, T1ρ mapping was compared to cine imaging, T2 mapping and conventional post-contrast 2D late gadolinium enhancement (LGE). T1ρ values were assessed in remote and injured areas, using LGE as reference. RESULTS: Despite breath holds, respiratory motion throughout T1ρw images was much larger in patients than in healthy subjects (5.1 ± 2.7 mm vs. 0.5 ± 0.4 mm, P < 0.01). In patients, the model-based non-rigid motion correction improved the alignment of T1ρw images, with higher DSC (87.7 ± 5.3% vs. 82.2 ± 7.5%, P < 0.01), and lower MPD (3.5 ± 1.9 mm vs. 5.1 ± 2.7 mm, P < 0.01). This resulted in significantly improved quality of the T1ρ maps (3.6 ± 0.6 vs. 2.1 ± 0.9, P < 0.01). Using this approach, T1ρ mapping could be used to identify LGE in patients with 93% sensitivity and 89% specificity. T1ρ values in injured (LGE positive) areas were significantly higher than in the remote myocardium (68.4 ± 7.9 ms vs. 48.8 ± 6.5 ms, P < 0.01). CONCLUSIONS: The proposed motion-corrected T1ρ mapping framework enables a quantitative characterization of myocardial injuries with relatively low sensitivity to respiratory motion. This technique may be a robust and contrast-free adjunct to LGE for gaining new insight into myocardial structural disorders.


Asunto(s)
Medios de Contraste , Infarto del Miocardio , Gadolinio , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Miocardio , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
9.
J Cardiothorac Vasc Anesth ; 35(12): 3547-3556, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34503891

RESUMEN

OBJECTIVE: The European System for Cardiac Operative Risk Evaluation II (EuroSCORE II) initially developed for predicting early postoperative mortality of all types of cardiac surgery, is less able to predict, more specifically, long-term outcomes after aortic valve replacement (AVR). The study authors here evaluated the risk factors for three-year mortality after isolated aortic valve replacement (AVR) for severe calcified tricuspid aortic valve stenosis and compared them with EuroSCORE II to predict long-term outcomes. DESIGN: A retrospective study. SETTING: A university teaching hospital. PARTICIPANTS: This study included 1,101 adults who underwent isolated AVR for severe calcified tricuspid aortic valve stenosis between September 2010 to June 2015. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was that of three-year all-cause mortality after AVR. By three years, 168 patients (15.3%) had died. Risk factors for all-cause mortality were: male gender (odds ratio [OR] = 1.78; 95% confidence interval [CI] = 1.21-2.62; p < 0.01), peripheral arterial disease (OR = 1.77; 95% CI = 1.08-2.92; p = 0.03), age (OR = 1.06 per year increase; 95% CI =1.04-1.09; p < 0.01), pulmonary artery systolic pressure (OR = 1.02 per mmHg increase; 95% CI = 1.01-1.03; p < 0.01), platelet count (OR = 1.003 per G/L increase; 95% CI = 1.000-1.005; p = 0.04), and valve area (OR = 0.97 per cm²/m² increase; 95% CI= 0.95-0.99; p < 0.01). The area under the receiver operating characteristic curves were 0.67 (95% CI = 0.60-0.75) and 0.60 (95% CI = 0.56-0.65) for the authors' logistic regression model and EuroSCORE II, respectively (p = 0.11). CONCLUSIONS: The study authors identified six independent risk factors for three-year mortality after isolated AVR. The logistic regression model had relatively modest predictive performance for three-year mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
10.
J Card Surg ; 35(11): 3116-3119, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32949043

RESUMEN

BACKGROUND: HeartMate 3 is a left ventricular assist device, composed of a centrifugal pump. It can be applied as a myocardial recovery, a bridge to transplant, or a destination therapy, in the treatment of patients with left ventricular heart failure. METHODS: Herein we describe a technique applied against a giant aneurysmal dilatation, which combines a surgical device implantation and a left ventricular reconstruction using a double patch. RESULTS: The patch minimizes thrombotic risk thanks to its internal bovine pericardium layer, which is in contact with blood. CONCLUSIONS: The outlined technique is relatively reproducible and safe in a selected group of patients, as it employs a high-quality device and enables the restoration of an appropriate ventricular geometry.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Aneurisma Cardíaco/cirugía , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Procedimientos de Cirugía Plástica/métodos , Diseño de Prótesis , Implantación de Prótesis/métodos , Animales , Bovinos , Aneurisma Cardíaco/complicaciones , Insuficiencia Cardíaca/etiología , Humanos
11.
Eur J Anaesthesiol ; 37(10): 889-897, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32925436

RESUMEN

BACKGROUND: An inverse linear relationship has been reported between pre-operative fibrinogen levels and postoperative blood loss in cardiac surgery. However, recently high pre-operative fibrinogen levels have also been reported to be associated with increased blood transfusion and re-operation. OBJECTIVE: We tested the hypothesis that the relationship between pre-operative fibrinogen levels and severe peri-operative bleeding is not linear. DESIGN: A large-scale (n = 3883) single-centre retrospective study. SETTING: A tertiary care teaching hospital. PATIENTS: We analysed data from our institutional database which includes all patients above 18 years who underwent on-pump cardiac surgery through a sternotomy between September 2010 and May 2014. MAIN OUTCOME MEASURES: Peri-operative severe bleeding adapted from the Universal Definition of Peri-operative Bleeding, class 3 or 4. The relationship between pre-operative fibrinogen levels and peri-operative severe bleeding was analysed by binary logistic regression. A cubic B-spline transformation was used to estimate the relationship between pre-operative fibrinogen level associated with excessive peri-operative bleeding. RESULTS: Severe peri-operative bleeding was observed in 957 (24.6%) patients. An L-shaped relationship was observed between pre-operative fibrinogen levels and 24-h postoperative blood loss. The relationship between pre-operative fibrinogen levels and severe peri-operative bleeding (i.e. Universal Definition of Peri-operative Bleeding class 3 or 4) was U-shaped: the risk of severe peri-operative bleeding bottomed at 3.3 g l when the upward sloping curve started at 5.8 g l with a steeper increase above 8.2 g l. CONCLUSION: We reported a U-shaped relationship between severe peri-operative bleeding and pre-operative fibrinogen levels. While a low-level of fibrinogen appears to be associated with a high risk of bleeding, a high level does not necessarily protect the patient against such a risk and could even be a risk factor for peri-operative bleeding.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Fibrinógeno , Humanos , Plasma , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Estudios Retrospectivos
12.
J Cardiothorac Vasc Anesth ; 33(11): 3010-3019, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31153719

RESUMEN

OBJECTIVES: Presently, there is enthusiasm for the Enhanced Recovery After Surgery (ERAS) program. The literature clearly indicates this type of program could shorten hospital length of stay and improve patient outcome. However, most of the studies conducted have encompassed mainly colorectal and orthopedic surgeries. Thus, in an effort to provide more evidence to the literature, the authors prospectively investigated the feasibility and clinical effectiveness of a dedicated ERAS program for mini-invasive aortic valve replacements (MIAVRs). DESIGN: Observational before-and-after trial. SETTING: University hospital. PARTICIPANTS: Consecutive patients scheduled for an MIAVR via a mini-sternotomy during 2 time periods-before (MIAVR group) and after implementation of an ERAS program (MIAVR-ERAS group). INTERVENTIONS: Patients in the dedicated MIAVR-ERAS group followed a dedicated pathway specifically designed for this procedure, which encompasses several evidence-based medicine elements for cardiac surgery. MEASUREMENTS AND MAIN RESULTS: Data on patient demographics, patient characteristics, compliance to the ERAS protocol, postoperative morphine consumption, postoperative pain scores, postoperative complications, hospital length of stay, and hospital readmission rate were collected and compared. Twenty-three patients were enrolled in each group. Patients enrolled in the new protocol had significantly lower postoperative pain scores (p = 0.03). The median hospital length of stay was 10 (9-13.5) and 7 (6.5-8) days in the traditional MIAVR group and in the MIAVR-ERAS group, respectively (p < 0.001). CONCLUSIONS: An ERAS pathway planned for MIAVR seems feasible and was associated with a shorter length of hospital stay with trends toward both less opioid consumption and less postoperative complications.


Asunto(s)
Válvula Aórtica/cirugía , Recuperación Mejorada Después de la Cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Tiempo de Internación/tendencias , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Atención Perioperativa/métodos , Complicaciones Posoperatorias/epidemiología , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Estudios Prospectivos , Resultado del Tratamiento
13.
Perfusion ; 34(8): 640-650, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31250726

RESUMEN

BACKGROUND: A high perioperative blood lactate level has been reported to be associated with poor outcomes after cardiac surgery. More than isolated peaks of lactate values, it should be more interesting to take into account changes in intraoperative blood lactate level (∆Lact). This large-scale retrospective study evaluated the relationship between ∆Lact and overall intensive care unit morbidity and 30-day all-cause mortality. METHODS: Perioperative data from consecutive patients undergoing on-pump cardiac surgery between September 2010 and June 2016 were retrospectively analysed through our institutional database including clinical, transfusion and laboratory test results implemented prospectively by physicians. Blood lactate levels were initially measured after induction of anaesthesia (baseline) and periodically during the surgery. The ∆Lact was defined as the difference between the highest intraoperative blood lactate and the baseline lactate level and offered the opportunity to stratify patients into four subgroups: ⩽0, 0.1-0.9, 1-1.9 and ⩾2 mmol L-1. RESULTS: From the 7,795 patients found eligible during the study period, 7,447 patients were analysed. The median ∆Lact of our patients was 0.6 (0.3-1) mmol L-1. Most of the studied patients (65.9%) exhibited a ∆Lact between 0.1 and 0.9 mmol L-1. A concentration-dependent relationship was observed between ∆Lact and intensive care unit morbidity and 30-day mortality. After adjustment for co-variables, all ∆Lact > 0 was associated with an increase in overall intensive care unit morbidity. An independent relationship was also found between ∆Lact and 30-day mortality as of a 1 mmol L-1 increase. CONCLUSION: Our results suggest that ∆Lact is associated with poor short-term outcomes in adult cardiac surgical patients.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Ácido Láctico/sangre , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
14.
Circ J ; 82(10): 2518-2522, 2018 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-30068794

RESUMEN

BACKGROUND: Recently, the carotid artery has been used as an alternative approach for transcatheter aortic valve implantation (TAVI). The aim of this study was to prove the safety and feasibility of transcarotid (TC) vs. transfemoral (TF) TAVI. Methods and Results: This retrospective study enrolled 726 consecutive patients with severe symptomatic aortic stenosis. All patients underwent TC-TAVI or TF-TAVI at Hôpital Haut-Lévèque, Bordeaux Heart University Hospital between September 2012 and October 2017. The TC-TAVI (n=83) and TF-TAVI (n=643) groups were compared statistically. The EuroSCORE II was significantly higher (8.2±6.7 vs. 6.4±5.5; P=0.007) and rates of current smoking, dyslipidemia and peripheral arterial disease were higher in the TC-TAVI than TF-TAVI group. All TC-TAVIs and 9.3% of TF-TAVIs were performed under general anesthesia. Radiation time was significantly shorter in the TC-TAVI than TF-TAVI group (14.5±6.0 vs. 23.0±10.8 min; P<0.001). Postimplant balloon valvuloplasty was performed more frequently in the TF-TAVI than TC-TAVI group (7.2% vs. 19.4%; P=0.006). Postoperative echocardiographic data were similar between the 2 groups, and there were no significant differences in 30-day mortality (8.4% vs. 5.0%; P=0.189) or stroke rate (1.2% vs. 2.6%; P=0.428) between the TF-TAVI and TC-TAVI groups. CONCLUSIONS: The feasibility and 30-day safety of TC-TAVI and TF-TAVI are similar. When TF-TAVI is not suitable anatomically for a particular patient, TC-TAVI is a preferable alternative.


Asunto(s)
Arterias Carótidas/cirugía , Arteria Femoral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/estadística & datos numéricos , Ecocardiografía , Femenino , Humanos , Masculino , Mortalidad , Enfermedad Arterial Periférica , Complicaciones Posoperatorias , Estudios Retrospectivos , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
Europace ; 19(1): 88-95, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26811434

RESUMEN

AIMS: Left ventricular (LV) lead implantation through the coronary sinus (CS) can be limited and sometimes not possible-alternative approaches are needed. Minimally invasive, robotically guided LV lead implantation has major advantages, but there are little published data about the short- and long-term follow-ups, in terms of feasibility, safety, electrical performance, and impact on clinical outcome. METHODS AND RESULTS: A total of 21 heart failure patients underwent robotically guided LV lead implantation using the Da Vinci Robotic System. Indications were failed implant with conventional approach through the CS (n = 16) and non-response to conventional cardiac resynchronization therapy (n = 5). During the procedure, the entire LV free wall was exposed through 3 transthoracic ports (10 mm diameter each) allowing ample choice of stimulation site and the ability to implant 2 LV leads via a Y connector. Patients were prospectively followed up for 1 year. The two LV leads were successfully implanted in all patients. No peri-procedural complications were observed. After a mean stay in the intensive care unit of 1.2 ± 4 days, the 21 patients were hospitalized in the EP department for 6.7 ± 2.9 days. Acute LV thresholds were excellent (1.0 V ± 0.6/0.4 ms) and stayed stable at 1-year follow-up (1.5 V ± 0.6/0.4 ms, P = 0.21). Four patients demonstrated an increased threshold (>2 V/0.4 ms). There was no phrenic nerve stimulation. After 12 months, in the failed implant group, 69% of the patients were echocardiographic and clinical responders. CONCLUSION: The robotic approach was feasible, safe, and minimally invasive. Accordingly, robotically guided LV lead implantation seems to offer a new alternative when conventional approaches are not suitable.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Procedimientos Quirúrgicos Cardíacos/métodos , Insuficiencia Cardíaca/terapia , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
16.
Am J Physiol Heart Circ Physiol ; 310(10): H1371-80, 2016 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-26968545

RESUMEN

To provide a model close to the human heart, and to study intrinsic cardiac function at the same time as electromechanical coupling, we developed a magnetic resonance (MR)-compatible setup of isolated working perfused pig hearts. Hearts from pigs (40 kg, n = 20) and sheep (n = 1) were blood perfused ex vivo in the working mode with and without loaded right ventricle (RV), for 80 min. Cardiac function was assessed by measuring left intraventricular pressure and left ventricular (LV) ejection fraction (LVEF), aortic and mitral valve dynamics, and native T1 mapping with MR imaging (1.5 Tesla). Potential myocardial alterations were assessed at the end of ex vivo perfusion from late-Gadolinium enhancement T1 mapping. The ex vivo cardiac function was stable across the 80 min of perfusion. Aortic flow and LV-dP/dtmin were significantly higher (P < 0.05) in hearts perfused with loaded RV, without differences for heart rate, maximal and minimal LV pressure, LV-dP/dtmax, LVEF, and kinetics of aortic and mitral valves. T1 mapping analysis showed a spatially homogeneous distribution over the LV. Simultaneous recording of hemodynamics, LVEF, and local cardiac electrophysiological signals were then successfully performed at baseline and during electrical pacing protocols without inducing alteration of MR images. Finally, (31)P nuclear MR spectroscopy (9.4 T) was also performed in two pig hearts, showing phosphocreatine-to-ATP ratio in accordance with data previously reported in vivo. We demonstrate the feasibility to perfuse isolated pig hearts in the working mode, inside an MR environment, allowing simultaneous assessment of cardiac structure, mechanics, and electrophysiology, illustrating examples of potential applications.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Metabolismo Energético , Corazón/fisiología , Hemodinámica , Preparación de Corazón Aislado/métodos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Miocardio/metabolismo , Perfusión , Potenciales de Acción , Adenosina Trifosfato/metabolismo , Animales , Presión Arterial , Estudios de Factibilidad , Frecuencia Cardíaca , Cinética , Fosfocreatina/metabolismo , Oveja Doméstica , Volumen Sistólico , Sus scrofa , Función Ventricular Izquierda , Función Ventricular Derecha , Presión Ventricular
17.
Pediatr Cardiol ; 37(5): 826-33, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27126593

RESUMEN

The onset of right ventricular dysfunction in patients presenting with congenital heart disease is associated with a dismal long-term outcome and often represents a therapeutic dead end. Our study had several objectives: (1) to analyse the anatomical, functional, histological and cellular characteristics of an animal model of repaired tetralogy of Fallot with right ventricular dysfunction (2) to test the new electrical treatment known as cardiac contractility modulation in this animal model. Seven sheep underwent a first surgery at the age of three weeks aiming to mimic the characteristics of a repaired tetralogy of Fallot. Five controls were sham-operated. Experimental studies were performed 12 months after the initial operation. The hemodynamic, echocardiographic, and mitochondrial function studies were carried out before and after cardiac contractility modulation in closed- and open-chest conditions. In this animal model of right ventricular dysfunction, short-term cardiac contractility modulation was associated with a significant improvement in (a) right ventricular function, as evidenced by a significant increase in right ventricular dP/dt (p < 0.05) (b) left ventricular function evidenced by the increase in left ventricular dP/dt max (p < 0.05) (c) in mitochondrial function (p < 0.05). In this animal model of chronic right ventricular dysfunction, cardiac contractility modulation significantly improved acute cardiac hemodynamic and mitochondrial functions of both ventricles and may represent a promising option in patients with right heart failure.


Asunto(s)
Contracción Miocárdica , Animales , Ventrículos Cardíacos , Ovinos , Tetralogía de Fallot , Disfunción Ventricular Derecha , Función Ventricular Derecha
18.
J Cardiothorac Vasc Anesth ; 29(6): 1489-97, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26119408

RESUMEN

OBJECTIVES: The robotic totally endoscopic coronary artery bypass graft (TECAB) surgery reduces patients' recovery time. The present trial investigated the feasibility and safety of an initial enhanced recovery after surgery (ERAS) path for patients undergoing robotic beating-heart TECAB and compared it with both conventional surgery and traditional perioperative care. It was hypothesized that the preliminary ERAS pathway associated with a beating-heart TECAB procedure could have a synergistic effect on postoperative patient care. DESIGN: Observational retrospective study. SETTING: University hospital. PARTICIPANTS: Patients scheduled for coronary artery bypass graft and undergoing robotic beating-heart TECAB (n = 38) were compared with those undergoing standard surgery and perioperative care (n = 33). The outcomes were the possibility of tracheal extubation at the end of the surgery and the incidence of postoperative complications. MEASUREMENTS AND MAIN RESULTS: The main comorbidities were similar between the 2 groups. Extubation on the operating table in the TECAB group was possible in all cases without requiring prompt endotracheal tube reinsertion. The proportion of patients transfused was significantly lower in the TECAB group (p = 0.009). In addition, the duration of intensive care unit and hospital stay were reduced significantly by 24 hours and by 4 days, respectively, in the TECAB group compared with the standard group (p< 0.05). CONCLUSIONS: The present results suggested that a program coupling a beating-heart TECAB with a preliminary ERAS path for patients requiring a single coronary revascularization is feasible and safe. This approach could reduce postoperative mechanical ventilation time, transfusion rate, and both intensive care unit and hospital stay.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Endoscopía/métodos , Recuperación de la Función , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38710669

RESUMEN

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Asunto(s)
Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Hemodinámica/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Femenino , Masculino , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía , Persona de Mediana Edad , Diseño de Prótesis
20.
ASAIO J ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701397

RESUMEN

The objective was to investigate the outcomes of concomitant venoarterial extracorporeal membrane oxygenation (ECMO) and left ventricular unloading with Impella (ECPELLA) compared with ECMO alone to treat patients affected by cardiogenic shock. Data from patients needing mechanical circulatory support from 4 international centers were analyzed. Of 438 patients included, ECMO alone and ECPELLA were adopted in 319 (72.8%) and 119 (27.2%) patients, respectively. Propensity score matching analysis identified 95 pairs. In the matched cohort, 30-day mortality rates in the ECMO and ECPELLA were 49.5% and 43.2% ( P = 0.467). The incidences of complications did not differ significantly between groups ( P = 0.877, P = 0.629, P = 1.000, respectively). After a median follow-up of 0.18 years (interquartile range 0.02-2.55), the use of ECPELLA was associated with similar mortality compared with ECMO alone (hazard ratio 0.81, 95% confidence interval 0.54-1.20, P = 0.285), with 1-year overall survival rates of 51.3% and 46.6%, for ECPELLA and ECMO alone, respectively. ECMO alone and ECPELLA are both effective strategies in patients needing mechanical circulatory support for cardiogenic shock, showing similar rates of early and mid-term survival.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA