Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 124(23): 230504, 2020 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-32603167

RESUMEN

Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/sqrt[Hz]. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.

2.
Proc Natl Acad Sci U S A ; 114(38): 10041-10046, 2017 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-28874582

RESUMEN

We investigated the structure of SiO2 glass up to 172 GPa using high-energy X-ray diffraction. The combination of a multichannel collimator with diamond anvil cells enabled the measurement of structural changes in silica glass with total X-ray diffraction to previously unachievable pressures. We show that SiO2 first undergoes a change in Si-O coordination number from fourfold to sixfold between 15 and 50 GPa, in agreement with previous investigations. Above 50 GPa, the estimated coordination number continuously increases from 6 to 6.8 at 172 GPa. Si-O bond length shows first an increase due to the fourfold to sixfold coordination change and then a smaller linear decrease up to 172 GPa. We reconcile the changes in relation to the oxygen-packing fraction, showing that oxygen packing decreases at ultrahigh pressures to accommodate the higher than sixfold Si-O coordination. These results give experimental insight into the structural changes of silicate glasses as analogue materials for silicate melts at ultrahigh pressures.

3.
J Appl Clin Med Phys ; 21(3): 162-166, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32107845

RESUMEN

PURPOSE: As C-arm linac radiation therapy evolves toward faster, more efficient delivery, and more conformal dosimetry, treatments with increasingly complex couch motions are emerging. Monitoring the patient motion independently of the couch motion during non-coplanar, non-isocentric, or dynamic couch treatments is a key bottleneck to their clinical implementation. The goal of this study is to develop a prototype real-time monitoring system for unconventional beam trajectories to ensure a safe and accurate treatment delivery. METHODS: An in-house algorithm was developed for tracking using a couch-mounted three-dimensional (3D) depth camera. The accuracy of patient motion detection on the couch was tested on a 3D printed phantom created from the body surface contour exported from the treatment planning system. The technique was evaluated against a commercial optical surface monitoring system with known phantom displacements of 3, 5, and 7 mm in lateral, longitudinal, and vertical directions by placing a head phantom on a dynamic platform on the treatment couch. The stability of the monitoring system was evaluated during dynamic couch trajectories, at speeds between 10.6 and 65 cm/min. RESULTS: The proposed monitoring system agreed with the ceiling mounted optical surface monitoring system in longitudinal, lateral, and vertical directions within 0.5 mm. The uncertainty caused by couch vibration increased with couch speed but remained sub-millimeter for speeds up to 32 cm/min. For couch speeds of 10.6, 32.2, and 65 cm/min, the uncertainty ranges were 0.27- 0.73 mm, 0.15-0.87 mm, and 0.28-1.29 mm, respectively. CONCLUSION: By mounting a 3D camera in the same frame-of-reference as the patient and eliminating dead spots, this proof of concept demonstrates real-time patient monitoring during couch motion. For treatments with non-coplanar beams, multiple isocenters, or dynamic couch motion, this provides additional safety without additional radiation dose and avoids some of the complexity and limitations of room mounted systems.


Asunto(s)
Algoritmos , Cabeza/efectos de la radiación , Movimiento , Aceleradores de Partículas/instrumentación , Posicionamiento del Paciente , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
4.
Phys Chem Chem Phys ; 19(4): 3265-3278, 2017 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-28084487

RESUMEN

Despite very significant developments in scattering experiments like X-ray and neutron diffraction, it has been challenging to elucidate the nature of tetrahedral molecular configurations in liquid water. A key question is whether the pair correlation functions, which can be obtained from scattering experiments, are sufficient to describe the tetrahedral ordering of water molecules. In our previous study (Dhabal et al., J. Chem. Phys., 2014, 141, 174504), using data-sets generated from reverse Monte Carlo and molecular dynamics simulations, we showed that the triplet correlation functions contain important information on the tetrahedrality of water in the liquid state. In the present study, X-ray scattering experiments and molecular dynamics (MD) simulations are used to link the isothermal pressure derivative of the structure factor with the triplet correlation functions for water. Triplet functions are determined for water up to 3.3 kbar at 298 K to display the effect of pressure on the water structure. The results suggest that triplet functions (H[combining tilde](q)) obtained using a rigid-body TIP4P/2005 water model are consistent with the experimental results. The triplet functions obtained in experiment as well as in simulations evince that in the case of tetrahedral liquids, exertion of higher pressure leads to a better agreement with the Kirkwood superposition approximation (KSA). We further validate this observation using the triplet correlation functions (g(3)(r,s,t)) calculated directly from simulation trajectory, revealing that both H[combining tilde](q) in q-space and g(3)(r,s,t) in real-space contain similar information on the tetrahedrality of liquids. This study demonstrates that the structure factor, even though it has only pair correlation information of the liquid structure, can shed light on three-body correlations in liquid water through its isothermal pressure derivative term.

5.
J Chem Phys ; 145(8): 084503, 2016 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-27586931

RESUMEN

We analyze the recent temperature dependent oxygen-oxygen pair-distribution functions from experimental high-precision x-ray diffraction data of bulk water by Skinner et al. [J. Chem. Phys. 141, 214507 (2014)] with particular focus on the intermediate range where small, but significant, correlations are found out to 17 Å. The second peak in the pair-distribution function at 4.5 Å is connected to tetrahedral coordination and was shown by Skinner et al. to change behavior with temperature below the temperature of minimum isothermal compressibility. Here we show that this is associated also with a peak growing at 11 Å which strongly indicates a collective character of fluctuations leading to the enhanced compressibility at lower temperatures. We note that the peak at ∼13.2 Å exhibits a temperature dependence similar to that of the density with a maximum close to 277 K or 4 °C. We analyze simulations of the TIP4P/2005 water model in the same manner and find excellent agreement between simulations and experiment albeit with a temperature shift of ∼20 K.

6.
Opt Express ; 23(6): 7300-11, 2015 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-25837073

RESUMEN

We present and demonstrate a novel protocol for distributing secret keys between two and only two parties based on N-party single-qubit Quantum Secret Sharing (QSS). We demonstrate our new protocol with N = 3 parties using phase-encoded photons. We show that any two out of N parties can build a secret key based on partial information from each other and with collaboration from the remaining N - 2 parties. Our implementation allows for an accessible transition between N-party QSS and arbitrary two party QKD without modification of hardware. In addition, our approach significantly reduces the number of resources such as single photon detectors, lasers and dark fiber connections needed to implement QKD.

7.
Proc Natl Acad Sci U S A ; 109(41): 16463-8, 2012 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-23010930

RESUMEN

The floating water bridge phenomenon is a freestanding rope-shaped connection of pure liquid water, formed under the influence of a high potential difference (approximately 15 kV). Several recent spectroscopic, optical, and neutron scattering studies have suggested that the origin of the bridge is associated with the formation of anisotropic chains of water molecules in the liquid. In this work, high energy X-ray diffraction experiments have been performed on a series of floating water bridges as a function of applied voltage, bridge length, and position within the bridge. The two-dimensional X-ray scattering data showed no direction-dependence, indicating that the bulk water molecules do not exhibit any significant preferred orientation along the electric field. The only structural changes observed were those due to heating, and these effects were found to be the same as for bulk water. These X-ray scattering measurements are supported by molecular dynamics (MD) simulations which were performed under electric fields of 10(6) V/m and 10(9) V/m. Directional structure factor calculations were made from these simulations parallel and perpendicular to the E-field. The 10(6) V/m model showed no significant directional-dependence (anisotropy) in the structure factors. The 10(9) V/m model however, contained molecules aligned by the E-field, and had significant structural anisotropy.


Asunto(s)
Campos Electromagnéticos , Simulación de Dinámica Molecular , Agua/química , Anisotropía , Modelos Químicos , Temperatura , Difracción de Rayos X
8.
Opt Lett ; 39(22): 6533-6, 2014 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25490512

RESUMEN

We demonstrate compact and accessible squeezed-light magnetometry using four-wave mixing in a single hot rubidium vapor cell. The strong intrinsic coherence of the four-wave mixing process results in nonlinear magneto-optical rotation (NMOR) on each mode of a two-mode relative-intensity squeezed state. This framework enables 4.7 dB of quantum noise reduction while the opposing polarization rotation signals of the probe and conjugate fields add to increase the total signal to noise ratio.


Asunto(s)
Luz , Magnetometría/métodos , Fenómenos Ópticos , Campos Magnéticos , Dinámicas no Lineales , Relación Señal-Ruido
9.
Pract Radiat Oncol ; 14(2): e165-e172, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38048988

RESUMEN

PURPOSE: The purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (CSI) using volumetric modulated arc therapy. METHODS AND MATERIALS: Two scripts were developed using the Eclipse Scripting Application Programming Interface to perform auto-plan preparation and optimization. Ten patients (age, 5-44 years) previously treated at our institution with low dose volumetric modulated arc therapy CSI (prescription of 12 Gy) before total body irradiation were selected to evaluate the efficacy of the proposed auto-planning process. Paired t tests compared the dosimetric indices of the auto-plans to the manually generated clinical plans. All plans were normalized to 95% of planning target volume (PTV) coverage with the prescription dose. Two physicians and one physicist were asked to evaluate the manual plans and auto-plans of each patient in a blinded retrospective review and to indicate clinical acceptability and which plans were preferred for treatment. RESULTS: Compared with the manual CSI plans, the auto plans obtained significant reductions in Dmean to the parotids, submandibular glands, larynx, thyroid, and significant reduction in the plan PTV Dmax and D0.03 cc. The standard deviation range of the dosimetric parameters was greatly reduced for auto plans (range, 0.1-1.3 Gy) relative to manual plans (range, 0.4-5.9 Gy) indicating better plan consistency. Among the 10 patients, the auto-plans were preferred over the manual plans 90% of the time by the reviewing experts. The required time for auto-planning was approximately 1 hour compared with estimated 4 or more hours for manual planning. CONCLUSIONS: Reductions in planning time without sacrifices in plan quality were obtained using the auto-planning process compared with manual planning. Variation in plan quality was also reduced. The auto-planning scripts will be made freely available to other institutions and clinics.


Asunto(s)
Irradiación Craneoespinal , Médicos , Radioterapia de Intensidad Modulada , Humanos , Preescolar , Niño , Adolescente , Adulto Joven , Adulto , Instituciones de Salud , Glándula Parótida
10.
Opt Express ; 21(6): 7549-59, 2013 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-23546137

RESUMEN

We present a workbench for the study of real-time quantum imaging by measuring the frame-by-frame quantum noise reduction of multi-spatial-mode twin beams generated by four wave mixing in Rb vapor. Exploiting the multiple spatial modes of this squeezed light source, we utilize spatial light modulators to selectively pass macropixels of quantum correlated modes from each of the twin beams to a high quantum efficiency balanced detector. In low-light-level imaging applications, the ability to measure the quantum correlations between individual spatial modes and macropixels of spatial modes with a single pixel camera will facilitate compressive quantum imaging with sensitivity below the photon shot noise limit.


Asunto(s)
Gases/análisis , Iluminación/instrumentación , Iluminación/métodos , Fotometría/instrumentación , Fotometría/métodos , Rubidio/química , Diseño de Equipo , Análisis de Falla de Equipo , Teoría Cuántica
11.
Phys Rev Lett ; 110(15): 156802, 2013 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-25167296

RESUMEN

We demonstrate the transduction of macroscopic quantum correlations by Ag localized surface plasmons (LSPs). Quantum noise reduction, or squeezed light, generated through four-wave mixing in Rb vapor, is coupled to a Ag nanohole array designed to exhibit LSP-mediated extraordinary-optical transmission spectrally coincident with the squeezed light source at 795 nm. This first demonstration of the coupling of quantum light into LSPs conserves spatially dependent quantum information, allowing for parallel quantum protocols in on-chip subwavelength quantum information processing.

12.
J Chem Phys ; 138(7): 074506, 2013 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-23445023

RESUMEN

Four recent x-ray diffraction measurements of ambient liquid water are reviewed here. Each of these measurements represents a significant development of the x-ray diffraction technique applied to the study of liquid water. Sources of uncertainty from statistical noise, Q-range, Compton scattering, and self-scattering are discussed. The oxygen-hydrogen contribution to the measured x-ray scattering pattern was subtracted using literature data to yield an experimental determination, with error bars, of the oxygen-oxygen pair-distribution function, g(OO)(r), which essentially describes the distribution of molecular centers. The extended Q-range and low statistical noise of these measurements has significantly reduced truncation effects and related errors in the g(OO)(r) functions obtained. From these measurements and error analysis, the position and height of the nearest neighbor maximum in g(OO)(r) were found to be 2.80(1) Å and 2.57(5) respectively. Numerical data for the coherent differential x-ray scattering cross-section I(X)(Q), the oxygen-oxygen structure factor S(OO)(Q), and the derived g(OO)(r) are provided as benchmarks for calibrating force-fields for water.

13.
Nano Lett ; 12(12): 6152-7, 2012 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-23171302

RESUMEN

We demonstrate the formation of a hybridized plasmon-exciton state exhibiting strong exciton-plasmon coupling in ZnO/Zn(0.85)Mg(0.15)O single quantum wells capped with arrays of Al nanodiscs. Tuning the quantum-well width and the diameter and pitch of the Al nanodisc arrays facilitates a transition from the weak-coupling regime into the strong coupling regime. Finite-difference time-domain simulations substantiate the localization of the plasmonic quadrupole moment within the ZnO quantum-well layer, resulting in a hybridized plasmonexciton state demonstrating a Rabi splitting of roughly 15 meV in heterostructures that exhibit a prominent plasmon quadrupole mode. The significant tunability offered by quantum-well heterostructures like those discussed here provides a flexible system for controlling exciton plasmon coupling in a device-compatible thin-film architecture.

14.
Pract Radiat Oncol ; 2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-37981253

RESUMEN

PURPOSE: Lung blocks for total-body irradiation are commonly used to reduce lung dose and prevent radiation pneumonitis. Currently, molten Cerrobend containing toxic materials, specifically lead and cadmium, is poured into molds to construct blocks. We propose a streamlined method to create 3-dimensional (3D)-printed lung block shells and fill them with tungsten ball bearings to remove lead and improve overall accuracy in the block manufacturing workflow. METHODS AND MATERIALS: 3D-printed lung block shells were automatically generated using an inhouse software, printed, and filled with 2 to 3 mm diameter tungsten ball bearings. Clinical Cerrobend blocks were compared with the physician drawn blocks as well as our proposed tungsten filled 3D-printed blocks. Physical and dosimetric comparisons were performed on a linac. Dose transmission through the Cerrobend and 3D-printed blocks were measured using point dosimetry (ion-chamber) and the on-board Electronic-Portal-Imaging-Device (EPID). Dose profiles from the EPID images were used to compute the full-width-half-maximum and to compare with the treatment-planning-system. Additionally, the coefficient-of-variation in the central 80% of full-width-half-maximum was computed and compared between Cerrobend and 3D-printed blocks. RESULTS: The geometric difference between treatment-planning-system and 3D-printed blocks was significantly lower than Cerrobend blocks (3D: -0.88 ± 2.21 mm, Cerrobend: -2.28 ± 2.40 mm, P = .0002). Dosimetrically, transmission measurements through the 3D-printed and Cerrobend blocks for both ion-chamber and EPID dosimetry were between 42% to 48%, compared with the open field. Additionally, coefficient-of-variation was significantly higher in 3D-printed blocks versus Cerrobend blocks (3D: 4.2% ± 0.6%, Cerrobend: 2.6% ± 0.7%, P < .0001). CONCLUSIONS: We designed and implemented a tungsten filled 3D-printed workflow for constructing total-body-irradiation lung blocks, which serves as an alternative to the traditional Cerrobend based workflow currently used in clinics. This workflow has the capacity of producing clinically useful lung blocks with minimal effort to facilitate the removal of toxic materials from the clinic.

15.
Opt Lett ; 37(9): 1538-40, 2012 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-22555730

RESUMEN

A zinc interstitial defect present but unobservable in ZnO thin films annealed at 500 °C in oxygen or in atmosphere was selectively detected by interaction of the film with an Ag surface-plasmon polariton. The time-dependent differential reflectivity of the ZnO near the ZnO/MgO interface exhibited a subpicosecond decay followed by a several nanosecond recovery, consistent with the Purcell-enhanced Zn interstitial luminescence seen in Ag-ZnO heterostructures. Heterostructures annealed at other temperatures showed significantly greater band-edge photoluminescence and no evidence of the Zn interstitial defect.

16.
Pract Radiat Oncol ; 12(3): e216-e220, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34971793

RESUMEN

PURPOSE: Radiation therapy (RT) is essential to managing many pediatric malignancies but can provoke anxiety, fear, and discomfort for children owing to prolonged treatment time, extended course, and restrictive immobilization. Patients younger than 10 years frequently require daily general anesthesia (GA), which is resource intensive, expensive, potentially toxic, and anxiety and fear provoking. Audio-Visual Assisted Therapeutic Ambience in Radiation Therapy (AVATAR), a video streaming device, has been proposed as an alternative to anesthesia in patients aged 3 to 10 years. A pilot study evaluating the efficacy of this novel innovation is accruing, but patients younger than 3 years are ineligible. METHODS AND MATERIALS: We simulated a 2-year-old with stage IV Wilms tumor for bilateral whole-lung and left-flank irradiation without GA. Using AVATAR, we attempted to deliver RT to this patient without sedation. Patient anxiety at the time of simulation and at the beginning, middle, and end of the treatment course was characterized using the validated Modified Yale Preoperative Anxiety Score (mYPAS) measurement tool. RESULTS: Although the patient tolerated computed tomography simulation without GA or AVATAR use, his mYPAS of 14 out of 18 indicated significant anxiety. Using AVATAR, all treatments were delivered without GA; his mYPASs were 5 and 4 (the lowest possible) and 4 at the first, midcourse, and final treatments, indicating no significant anxiety and a decrease from the pre-AVATAR baseline. Without GA, the time to deliver RT decreased by 66% from 90 to 30 minutes. CONCLUSIONS: We describe an expanded, previously unreported indication for AVATAR by demonstrating the feasibility of this approach to reduce or omit anesthesia in appropriate younger patients currently excluded from ongoing trials. The financial and quality-of-life benefits (including decreased stress, anxiety, toxic effects, cost, and appointment time) of AVATAR use may be extendable to a younger patient population than previously thought. In older children, prospective validation is ongoing, but additional study in patients younger than 3 years is needed.


Asunto(s)
Ansiedad , Neoplasias , Anestesia General , Ansiedad/etiología , Niño , Preescolar , Humanos , Neoplasias/radioterapia , Proyectos Piloto , Cuidados Preoperatorios
17.
Med Phys ; 48(1): 366-375, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33107049

RESUMEN

PURPOSE: The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. METHODS: Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. RESULTS: Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and D max within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. CONCLUSIONS: The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.


Asunto(s)
Nanopartículas del Metal , Radiocirugia , Oro , Método de Montecarlo , Radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Rayos X
18.
Phys Med Biol ; 66(7)2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33657537

RESUMEN

Purpose. Radiation dose delivered to targets located near the upper-abdomen or in the thorax are significantly affected by respiratory-motion. Relatively large-margins are commonly added to compensate for this motion, limiting radiation-dose-escalation. Internal-surrogates of target motion, such as a radiofrequency (RF) tracking system, i.e. Calypso®System, are used to overcome this challenge and improve normal-tissue sparing. RF tracking systems consist of implanting transponders in the vicinity of the tumor to be tracked using radiofrequency-waves. Unfortunately, although the manufacture provides a universal quality-assurance (QA) phantom, QA-phantoms specifically for lung-applications are limited, warranting the development of alternative solutions to fulfil the tests mandated by AAPM's TG142. Accordingly, our objective was to design and develop a motion-phantom to evaluate Calypso for lung-applications that allows the Calypso®Beacons to move in different directions to better simulate truelung-motion.Methods and Materials.A Calypso lung QA-phantom was designed, and 3D-printed. The design consists of three independent arms where the transponders were attached. A pinpoint-chamber with a buildup-cap was also incorporated. A 4-axis robotic arm was programmed to drive the motion-phantom to mimic breathing. After acquiring a four-dimensional-computed-tomography (4DCT) scan of the motion-phantom, treatment-plans were generated and delivered on a Varian TrueBeam®with Calypso capabilities. Stationary and gated-treatment plans were generated and delivered to determine the dosimetric difference between gated and non-gated treatments. Portal cine-images were acquired to determine the temporal-accuracy of delivery by calculating the difference between the observed versus expected transponders locations with the known speed of the transponders' motion.Results.Dosimetric accuracy is better than the TG142 tolerance of 2%. Temporal accuracy is greater than, TG142 tolerance of 100 ms for beam-on, but less than 100 ms for beam-hold.Conclusions.The robotic QA-phantom designed and developed in this study provides an independent phantom for performing Calypso lung-QA for commissioning and acceptance testing of Calypso for lung treatments.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Humanos , Pulmón/diagnóstico por imagen , Neonicotinoides , Fantasmas de Imagen , Impresión Tridimensional , Tiazinas
19.
Phys Med Biol ; 65(15): 155018, 2020 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-32521512

RESUMEN

Gynecologic cancers are often asymmetric, yet current Ir-192 brachytherapy techniques provide only limited radial modulation of the dose. The shielded solutions investigated here solve this by providing the ability to modulate between highly asymmetric and radially symmetric dose distributions at a given location. To find applicator designs that can modulate between full dose and less than 50% dose, at the dimensions of the urethra, a 2D calculation algorithm was developed to narrow down the search space. Two shielding design types were then further investigated using Monte Carlo and Boltzmann-solver dose calculation algorithms. 3D printing techniques using ISO 10993 certified biocompatible plastics and 3D printable tungsten-loaded plastics were tested. It was also found that shadowing effects set by the shape of the shielding cannot be easily modulated out, hence careful design is required. The shielded applicator designs investigated here, allow for reduction of the dose by over 50% at 5 mm from the applicator surface in desired regions, while also allowing radially symmetric dose with isodose line deviations less than 0.5 mm from circular. The shielding designs were also chosen with treatment delivery time in mind. Treatment times for these shielded designs were found to be less than 1.4 times longer than a 6-channel unshielded cylinder for the equivalent fully symmetric dose distribution. The 2D calculation methods developed here provide a simple way to rapidly evaluate shielding designs, while the 3D printing techniques also allow for devices with novel shapes to be rapidly prototyped. Both TOPAS Monte Carlo and Acuros BV calculations show that significant dose shaping and organ at risk sparing can be achieved without significantly compromising the plan in regions that require the full dose.


Asunto(s)
Braquiterapia/instrumentación , Radioisótopos de Iridio/uso terapéutico , Impresión Tridimensional , Radioterapia de Intensidad Modulada/instrumentación , Algoritmos , Femenino , Humanos , Método de Montecarlo , Plásticos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Tungsteno
20.
Med Phys ; 47(11): 5496-5504, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32969075

RESUMEN

PURPOSE: Radiation dose delivered to targets located near the upper abdomen or thorax are significantly affected by respiratory motion, necessitating large margins, limiting dose escalation. Surrogate motion management devices, such as the Real-time Position Management (RPM™) system (Varian Medical Systems, Palo Alto, CA), are commonly used to improve normal tissue sparing. Alternative to current solutions, we have developed and evaluated the feasibility of a real-time position management system that leverages the motion data from the onboard hardware of Apple iOS devices to provide patients with visual coaching with the potential to improve the reproducibility of breathing as well as improve patient compliance and reduce treatment delivery time. METHODS AND MATERIALS: The iOS application, coined the Instant Respiratory Feedback (IRF) system, was developed in Swift (Apple Inc., Cupertino, CA) using the Core-Motion library and implemented on an Apple iPhone® devices. Operation requires an iPhone®, a three-dimensional printed arm, and a radiolucent projector screen system for feedback. Direct comparison between IRF, which leverages sensor fusion data from the iPhone®, and RPM™, an optical-based system, was performed on multiple respiratory motion phantoms and volunteers. The IRF system and RPM™ camera tracking marker were placed on the same location allowing for simultaneous data acquisition. The IRF surrogate measurement of displacement was compared to the signal trace acquired using RPM™ with univariate linear regressions and Bland-Altman analysis. RESULTS: Periodic motion shows excellent agreement between both systems, and subject motion shows good agreement during regular and irregular breathing motion. Comparison of IRF and RPM™ show very similar signal traces that were significantly related across all phantoms, including those motion with different amplitude and frequency, and subjects' waveforms (all r > 0.9, P < 0.0001). We demonstrate the feasibility of performing four-dimensional cone beam computed tomography using IRF which provided similar image quality as RPM™ when reconstructing dynamic motion phantom images. CONCLUSIONS: Feasibility of an iOS application to provide real-time respiratory motion is demonstrated. This system generated comparable signal traces to a commercially available system and offers an alternative method to monitor respiratory motion.


Asunto(s)
Oncología por Radiación , Algoritmos , Biorretroalimentación Psicológica , Tomografía Computarizada Cuatridimensional , Humanos , Movimiento , Fantasmas de Imagen , Reproducibilidad de los Resultados , Respiración , Teléfono Inteligente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA