Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-38310281

RESUMEN

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Diabetes Mellitus , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Sirolimus/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/inducido químicamente , Sistema de Registros , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología
2.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38056772

RESUMEN

INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS). METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events. RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure. CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

3.
JACC Cardiovasc Interv ; 16(14): 1794-1803, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37495352

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications. OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease. METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee. RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881). CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Infarto del Miocardio , Humanos , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Angioplastia Coronaria con Balón/efectos adversos , Sirolimus/efectos adversos , Resultado del Tratamiento , Infarto del Miocardio/complicaciones , Sistema de Registros , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA