Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 121(12): e2314265121, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38470930

RESUMEN

The debate on the sign of the soil moisture-precipitation feedback remains open. On the one hand, studies using global coarse-resolution climate models have found strong positive feedback. However, such models cannot represent convection explicitly. On the other hand, studies using km-scale regional climate models and explicit convection have reported negative feedback. Yet, the large-scale circulation is prescribed in such models. This study revisits the soil moisture-precipitation feedback using global, coupled simulations conducted for 1 y with explicit convection and compares the results to coarse-resolution simulations with parameterized convection. We find significant differences in a majority of points with feedback that is weaker and dominantly negative with explicit convection. The model with explicit convection is more often in a wet regime and prefers the triggering of convection over dry soil in the presence of soil moisture heterogeneity, in contrast to the coarse-resolution model. Further analysis indicates that the feedback not only between soil moisture and evapotranspiration but also between evapotranspiration and precipitation is weaker, in better agreement with observations. Our findings suggest that coarse-resolution models may not be well suited to study aspects of climate change over land such as changes in droughts and heatwaves.

2.
J Neuroimaging ; 13(2): 133-9, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12722495

RESUMEN

BACKGROUND AND PURPOSE: Endarterectomy has been proved to be an effective stroke prevention procedure. However, there are still inconsistencies between the results of different preoperative evaluation methods, which may sometimes complicate treatment plans. This study measured the discrepancies between different angiographic grading methods and attempted to further assess the accuracy of the carotid duplex examination according to these different angiographic grading methods. METHODS: One hundred seventy-one preendarterectomy carotid duplex examinations and angiograms were reviewed. All angiograms were measured blindly by one of the authors using the North American Symptomatic Carotid Endarterectomy Trial (N), the European Carotid Surgery Trial (E), and the common carotid (C) methods. The measurement results were further converted into the area of stenosis indices (N2, E2, and C2, respectively). By using regression testing, all results could be compared. The duplex examination data were then compared with the results of different angiographic measurement methods to evaluate their accuracy. RESULTS: The measurement results of all angiographic grading methods were well correlated. Using different angiographic grading systems as the gold standard, duplex examination for screening endarterectomy candidates produced the following results: According to the N method, accuracy was 74%; according to the E method, accuracy was 90%; and according to the C method, the accuracy rate was 92%. According to N2, accuracy was 88%; according to E2, accuracy was 94%; and according to C2, the accuracy rate was 93%. CONCLUSIONS: The measurement results of all 3 commonly used angiographic grading methods were linearly correlated with one another. (It is important to note that none of those standards should be treated as the only gold standard.) In this study, the duplex criteria have a greater accuracy rate according to E or C rather than N. However, this study also demonstrated that the cut point of the Doppler criteria is the determinant factor for accuracy rather than which gold standard was compared. Through careful adjustment of the cutoff criteria, carotid duplex can be highly accurate, despite the use of different reference standards.


Asunto(s)
Angiografía , Angiografía/métodos , Estenosis Carotídea/diagnóstico por imagen , Ultrasonografía Doppler Dúplex/métodos , Anciano , Anciano de 80 o más Años , Angiografía/normas , Angiografía de Substracción Digital , Estenosis Carotídea/cirugía , Endarterectomía Carotidea , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Ultrasonografía Doppler Dúplex/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA