Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Vet Res ; 19(1): 141, 2023 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-37660015

RESUMEN

BACKGROUND: Upper urinary tract stones are increasingly prevalent in pet cats and are difficult to manage. Surgical procedures to address obstructing ureteroliths have short- and long-term complications, and medical therapies (e.g., fluid diuresis and smooth muscle relaxants) are infrequently effective. Burst wave lithotripsy is a non-invasive, ultrasound-guided, handheld focused ultrasound technology to disintegrate urinary stones, which is now undergoing human clinical trials in awake unanesthetized subjects. RESULTS: In this study, we designed and performed in vitro testing of a modified burst wave lithotripsy system to noninvasively fragment stones in cats. The design accounted for differences in anatomic scale, acoustic window, skin-to-stone depth, and stone size. Prototypes were fabricated and tested in a benchtop model using 35 natural calcium oxalate monohydrate stones from cats. In an initial experiment, burst wave lithotripsy was performed using peak ultrasound pressures of 7.3 (n = 10), 8.0 (n = 5), or 8.9 MPa (n = 10) for up to 30 min. Fourteen of 25 stones fragmented to < 1 mm within the 30 min. In a second experiment, burst wave lithotripsy was performed using a second transducer and peak ultrasound pressure of 8.0 MPa (n = 10) for up to 50 min. In the second experiment, 9 of 10 stones fragmented to < 1 mm within the 50 min. Across both experiments, an average of 73-97% of stone mass could be reduced to fragments < 1 mm. A third experiment found negligible injury with in vivo exposure of kidneys and ureters in a porcine animal model. CONCLUSIONS: These data support further evaluation of burst wave lithotripsy as a noninvasive intervention for obstructing ureteroliths in cats.


Asunto(s)
Enfermedades de los Gatos , Litotricia , Enfermedades de los Porcinos , Urolitiasis , Gatos , Humanos , Animales , Porcinos , Litotricia/veterinaria , Riñón , Urolitiasis/veterinaria , Oxalato de Calcio , Modelos Animales , Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Gatos/terapia
2.
J Biomech Eng ; 145(4)2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36173034

RESUMEN

The Circle of Willis (CoW) is a redundant network of blood vessels that perfuses the brain. The ringlike anatomy mitigates the negative effects of stroke by activating collateral pathways that help maintain physiological perfusion. Previous studies have investigated the activation of these pathways during embolic stroke and internal carotid artery occlusion. However, the role of collateral pathways during cerebral vasospasm-an involuntary constriction of blood vessels after subarachnoid hemorrhage-is not well-documented. This study presents a novel technique to create patient-specific computational fluid dynamics (CFD) simulations of the Circle of Willis before and during vasospasm. Computed tomographic angiography (CTA) scans are segmented to model the vasculature, and transcranial Doppler ultrasound (TCD) measurements of blood flow velocity are applied as boundary conditions. Bayesian analysis leverages information about the uncertainty in the measurements of vessel diameters and velocities to find an optimized parameter set that satisfies mass conservation and that is applied in the final simulation. With this optimized parameter set, the diameters, velocities, and flow rates fall within typical literature values. Virtual angiograms modeled using passive scalar transport agree closely with clinical angiography. A sensitivity analysis quantifies the changes in collateral flow rates with respect to changes in the inlet and outlet flow rates. This analysis can be applied in the future to a cohort of patients to investigate the relationship between the locations and severities of vasospasm, the patient-to-patient anatomical variability in the Circle of Willis, and the activation of collateral pathways.


Asunto(s)
Círculo Arterial Cerebral , Hidrodinámica , Círculo Arterial Cerebral/diagnóstico por imagen , Teorema de Bayes , Circulación Colateral/fisiología , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología
3.
J Acoust Soc Am ; 151(5): 3007, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35649925

RESUMEN

Phase aberration induced by soft tissue inhomogeneities often complicates high-intensity focused ultrasound (HIFU) therapies by distorting the field and, previously, we designed and fabricated a bilayer gel phantom to reproducibly mimic that effect. A surface pattern containing size scales relevant to inhomogeneities of a porcine body wall was introduced between gel materials with fat- and muscle-like acoustic properties-ballistic and polyvinyl alcohol gels. Here, the phantom design was refined to achieve relevant values of ultrasound absorption and scattering and make it more robust, facilitating frequent handling and use in various experimental arrangements. The fidelity of the interfacial surface of the fabricated phantom to the design was confirmed by three-dimensional ultrasound imaging. The HIFU field distortions-displacement of the focus, enlargement of the focal region, and reduction of focal pressure-produced by the phantom were characterized using hydrophone measurements with a 1.5 MHz 256-element HIFU array and found to be similar to those induced by an ex vivo porcine body wall. A phase correction approach was used to mitigate the aberration effect on nonlinear focal waveforms and enable boiling histotripsy treatments through the phantom or body wall. The refined phantom represents a practical tool to explore HIFU therapy systems capabilities.


Asunto(s)
Tratamiento con Ondas de Choque Extracorpóreas , Ultrasonido Enfocado de Alta Intensidad de Ablación , Acústica , Animales , Geles , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Fantasmas de Imagen , Porcinos , Ultrasonografía
4.
J Vasc Surg ; 61(6): 1637-41, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25864045

RESUMEN

Physician-modified endovascular grafts, with fenestrations added to accommodate major branch vessels, provide a means for endovascular treatment of abdominal aortic aneurysms that are adjacent to the renal arteries. Manual measurements of vessel origin locations from computed tomography images, however, take time and can lead to errors in the positions of the fenestrations. To make the fenestration process faster and more accurate, we have developed a procedure to create custom templates that serve as patient-specific guides for graft fenestration. We use a three-dimensional printer to create a clear rigid sleeve that replicates the patient's aorta and includes holes placed precisely at the locations of the branch vessels. The sleeve is slipped over the graft, the locations of the openings are marked with a pen, and the fenestrations are created after the sleeve is removed. Custom fenestration templates can potentially save procedural costs and make minimally invasive aortic aneurysm repair available to more patients.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diseño Asistido por Computadora , Procedimientos Endovasculares/instrumentación , Impresión Tridimensional , Diseño de Prótesis , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Simulación por Computador , Humanos , Imagenología Tridimensional , Modelos Cardiovasculares , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Am J Obstet Gynecol ; 213(1): 104.e1-104.e11, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26003058

RESUMEN

OBJECTIVE: Women who develop preeclampsia have a higher risk of future cardiovascular disease and diabetes compared to women who have uncomplicated pregnancies. We hypothesized that women with prior preeclampsia would have increased visceral adiposity that would be a major determinant of their metabolic and cardiovascular risk factors. STUDY DESIGN: We compared intraabdominal fat (IAF) area, insulin sensitivity index (SI), fasting lipids, low-density lipoprotein relative flotation rate, and brachial artery flow-mediated dilatation in 49 women with prior preeclampsia and 22 controls who were at least 8 months postpartum and matched for age, parity, body mass index, and months postpartum. Women were eligible if they did not smoke tobacco, use hormonal contraception, have chronic hypertension, or have a history of gestational diabetes. RESULTS: The groups were similar for age (mean ± SD: prior preeclampsia 33.4 ± 6.6 vs control 34.6 ± 4.3 years), parity (median: 1 for both), body mass index (26.7 ± 5.9 vs 24.0 ± 7.3 kg/m(2)), and months postpartum (median [25th-75th percentile]: 16 [13-38] vs 16.5 [13-25]). There were no significant differences in IAF area and SI. Despite this, women with preeclampsia had lower high-density lipoprotein (46.0 ± 10.7 vs 51.3 ± 9.3 mg/dL; P < .05), smaller/denser low-density lipoprotein relative flotation rate (0.276 ± 0.022 vs 0.289 ± 0.016; P = .02), higher systolic (114.6 ± 10.9 vs 102.3 ± 7.5 mm Hg) and diastolic (67.6 ± 7.5 vs 60.9 ± 3.6 mm Hg; P < .001) blood pressures, and impaired flow-mediated dilatation (4.5 [2-6.7] vs 8.8 [4.5-9.1] percent change, P < .05) compared to controls. In a subgroup analysis, women with nonsevere preeclampsia (n = 17) had increased IAF (98.3 [60.1-122.2]) vs 63.1 [40.1-70.7] cm(2); P = .02) and decreased SI (4.18 [2.43-5.25] vs 5.5 [3.9-8.3] × 10(-5) min(-1)/pmol/L; P = .035) compared to the controls, whereas women with severe preeclampsia (n = 32) were not different for IAF and SI. IAF was negatively associated with SI and positively associated with cardiovascular risk factors even after adjusting for the matching variables and total body fat. CONCLUSION: Women with prior preeclampsia have an atherogenic lipid profile and endothelial dysfunction compared to matched control subjects despite having similar adiposity and insulin sensitivity, suggesting that there are mechanisms separate from obesity and insulin resistance that lead to their cardiovascular risk factors. Visceral adiposity may have a role in contributing to these risk factors in the subgroup of women who have preeclampsia without severe features.


Asunto(s)
Preeclampsia/fisiopatología , Adulto , Distribución de la Grasa Corporal , Estudios Transversales , Endotelio Vascular/fisiología , Femenino , Glucosa/metabolismo , Humanos , Resistencia a la Insulina/fisiología , Grasa Intraabdominal , Periodo Posparto/fisiología , Embarazo , Vasodilatación/fisiología
6.
Ann Vasc Surg ; 27(2): 146-53, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22749436

RESUMEN

BACKGROUND: Ultrasonographic (US) assessment of abdominal aortic aneurysms is typically performed by measuring maximal aneurysm diameter from two-dimensional images. These measurements are prone to inaccuracies owing to image planes and interobserver variability. The purpose of this study was to compare the variability in diameter, cross-sectional area (CSA), and volume measurements of abdominal aortic aneurysms obtained using a three-dimensional (3D) US imaging system with those obtained using computed tomographic (CT) angiography, and to determine the reliability of these measures. METHODS: Seven patients in whom endovascular aneurysm repairs were performed underwent CT angiography in addition to a 3D US scan. Measurements computed using 3D surface reconstructions of CT and 3D US scans included maximum diameter, CSA, and aneurysm volume. The seven matched CT and 3D US scans were compared at baseline and 6 to 8 weeks later. RESULTS: The average aneurysm measured 57.2 mm on CT and 56.2 mm on US (P = 0.14). Correlation coefficients for diameter, CSA, and volume were 0.88, 0.90, and 0.93, respectively (all P values < 0.001). A Bland-Altman analysis demonstrated a strong agreement between 92% of the diameter, 96.4% of the CSA, and 100% of the volume measurements. The interrater reliability was remarkably high comparing the modalities (CT vs. US), and ranged from 0.934 to 0.997 for single measurements and 0.965 to 0.998 for all measurements together; moreover, there was a strong reliability when the tests were reviewed 6 to 8 weeks later, with a reliability of 0.962 to 0.998 for single measurements and 0.992 to 0.999 for all tests (all P values < 0.001). CONCLUSIONS: The 3D US is an accurate and noninvasive method of determining aneurysm size and geometry that is reproducible. Volumetric measurements may represent a significant advancement in long-term follow-up after endovascular aneurysm repair.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía
7.
J Biomech Eng ; 135(1): 011005, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23363216

RESUMEN

Arteriovenous fistulae are surgically created to provide adequate access for dialysis patients suffering from end-stage renal disease. It has long been hypothesized that the rapid blood vessel remodeling occurring after fistula creation is, in part, a process to restore the mechanical stresses to some preferred level, i.e., mechanical homeostasis. We present computational hemodynamic simulations in four patient-specific models of mature arteriovenous fistulae reconstructed from 3D ultrasound scans. Our results suggest that these mature fistulae have remodeled to return to ''normal'' shear stresses away from the anastomoses: about 1.0 Pa in the outflow veins and about 2.5 Pa in the inflow arteries. Large parts of the anastomoses were found to be under very high shear stresses >15 Pa, over most of the cardiac cycle. These results suggest that the remodeling process works toward restoring mechanical homeostasis in the fistulae, but that the process is limited or incomplete, even in mature fistulae, as evidenced by the elevated shear at or near the anastomoses. Based on the long term clinical viability of these dialysis accesses, we hypothesize that the elevated nonhomeostatic shear stresses in some portions of the vessels were not detrimental to fistula patency.


Asunto(s)
Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Homeostasis , Estrés Mecánico , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Hemodinámica , Humanos , Hidrodinámica , Imagenología Tridimensional , Modelos Biológicos , Diálisis Renal , Resistencia al Corte
8.
PLoS One ; 18(12): e0293907, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38060522

RESUMEN

Obesity is a common finding and a major pathogenetic factor in obstructive sleep apnea (OSA) in adults. To understand the mechanisms behind this, the present study investigated the tissue properties and respiratory kinematics of the tongue base and soft palate in the obese OSA minipig model. In 4 verified obese/OSA and 3 non-obese/non-OSA control minipigs, MRI fat-weighted images, ultrasound elastography (USE), and sleep video-fluoroscopy (SVF) were performed to quantify the fat composition, tissue stiffness, and respiratory kinematics of the tongue base and soft palate during sedated sleep. The results indicated that the fat composition gradually increased from the rostral to caudal tongue base, particularly in the posterior 1/3 of the tongue base, regardless of the presence of obesity and OSA. However, this trend was not seen in the soft palate and pharyngeal wall. The pharyngeal wall presented the highest fat composition as compared with the tongue base and soft palate. Overall, obese OSA minipigs showed stiffer tongue tissue than the controls, particularly in the rostral region of the tongue in obese Yucatan minipigs. The respiratory moving ranges of the soft palate were greater in both dorsal-ventral and rostral-caudal directions and during both respiratory and expiratory phases in OSA obese than control minipigs, and the largest moving ranges were seen in OSA obese Panepinto minipigs. The moving range of the tongue base was significantly smaller. These results suggest more fat infiltration in the caudal region of the tongue base regardless of the presence of obesity and/or OSA. The greater tissue stiffness of the tongue in obese OSA minipigs may result from altered neuromuscular drive.


Asunto(s)
Apnea Obstructiva del Sueño , Adulto , Animales , Humanos , Porcinos , Fenómenos Biomecánicos , Porcinos Enanos , Paladar Blando/patología , Lengua/patología , Obesidad
9.
Ultrasound Med Biol ; 49(12): 2451-2458, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37718123

RESUMEN

OBJECTIVE: Bacterial loads can be effectively reduced using cavitation-mediated focused ultrasound, or histotripsy. In this study, gram-negative bacteria (Escherichia coli) in suspension were used as model bacteria to evaluate the effectiveness of two regimens of histotripsy treatments: cavitation histotripsy (CH) and boiling histotripsy (BH). METHODS: Ten-milliliter volumes of Escherichia coli were treated at different negative focal pressure amplitudes and over time periods up to 40 min. Cavitation activity was characterized with coaxial passive cavitation detection (PCD) and synchronized plane wave B-mode imaging. RESULTS: CH treatments exhibited a threshold behavior that was consistent with PCD metrics of cavitation. Above the threshold, bacterial inactivation followed a monotonically increasing log-linear relationship that indicated an exponential inactivation rate. BH exhibited no threshold, but instead followed a different monotonically increasing inactivation rate. Inactivation rates were larger for BH at or below the CH threshold, and larger for CH substantially above the threshold. CH studies performed at different pulse lengths at the same duty cycle had similar inactivation rates, suggesting that at any given pressure amplitude, the "on time" was the most important variable for inactivating E. coli. The maximum inactivation was produced by CH at the highest pressure amplitudes used, leading to a log reduction >4.2 for a 40 min treatment. CONCLUSION: The results of this study suggest that both CH and BH can be used to inactivate E. coli in suspension, with the optimal regimen depending on the attainable peak negative focal pressure at the target.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Litotricia , Escherichia coli , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Litotricia/métodos , Fantasmas de Imagen
10.
J Vasc Surg ; 56(2): 403-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22551907

RESUMEN

OBJECTIVE: The mechanisms of restenosis in autogenous vein bypass grafts placed for peripheral artery disease are not completely understood. We investigated the role of hemodynamic stress in a case study of a revised bypass graft that failed due to restenosis. METHODS: The morphology of the lumen was reconstructed from a custom three-dimensional ultrasound system. Scans were taken at 1, 6, and 16 months after a patch angioplasty procedure. Computational hemodynamic simulations of the patient-specific model provided the blood flow features and the hemodynamic stresses on the vessel wall at the three times studied. RESULTS: The vessel was initially free of any detectable lesions, but a 60% diameter-reducing stenosis developed during the 16-month study interval. As determined from the simulations, chaotic and recirculating flow occurred downstream of the stenosis due to the sudden widening of the lumen at the patch location. Curvature and a sudden increase in the lumen cross-sectional area induced these flow features that are hypothesized to be conducive to intimal hyperplasia. Favorable agreement was found between simulation results and in vivo Doppler ultrasound velocity measurements. CONCLUSIONS: Transitional and chaotic flow occurs at the site of the revision, inducing a complex pattern of wall shear as computed with the hemodynamic simulations. This supports the hypothesis that the hemodynamic stresses in the revised segment, produced by the coupling of vessel geometry and chaotic flow, led to the intimal hyperplasia and restenosis of the graft.


Asunto(s)
Oclusión de Injerto Vascular/fisiopatología , Dilatación Patológica , Hemodinámica , Humanos , Hiperplasia , Estudios Retrospectivos , Vena Safena/patología , Vena Safena/trasplante , Estrés Mecánico , Trasplante Autólogo , Túnica Íntima/patología
11.
J Biomech Eng ; 133(4): 041008, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21428682

RESUMEN

We report a study of the role of hemodynamic shear stress in the remodeling and failure of a peripheral artery bypass graft. Three separate scans of a femoral to popliteal above-knee bypass graft were taken over the course of a 16 month period following a revision of the graft. The morphology of the lumen is reconstructed from data obtained by a custom 3D ultrasound system. Numerical simulations are performed with the patient-specific geometries and physiologically realistic flow rates. The ultrasound reconstructions reveal two significant areas of remodeling: a stenosis with over 85% reduction in area, which ultimately caused graft failure, and a poststenotic dilatation or widening of the lumen. Likewise, the simulations reveal a complicated hemodynamic environment within the graft. Preliminary comparisons with in vivo velocimetry also showed qualitative agreement with the flow dynamics observed in the simulations. Two distinct flow features are discerned and are hypothesized to directly initiate the observed in vivo remodeling. First, a flow separation occurs at the stenosis. A low shear recirculation region subsequently develops distal to the stenosis. The low shear region is thought to be conducive to smooth muscle cell proliferation and intimal growth. A poststenotic jet issues from the stenosis and subsequently impinges onto the lumen wall. The lumen dilation is thought to be a direct result of the high shear stress and high frequency pressure fluctuations associated with the jet impingement.


Asunto(s)
Simulación por Computador , Arteria Femoral/cirugía , Hemodinámica , Imagenología Tridimensional , Arteria Poplítea/cirugía , Injerto Vascular/métodos , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/fisiopatología , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Estudios Longitudinales , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Falla de Prótesis , Estudios Retrospectivos , Estrés Mecánico , Ultrasonografía
12.
Ultrasound Med Biol ; 47(7): 1920-1930, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33902954

RESUMEN

Abscesses are walled-off collections of infected fluids that often develop as complications in the setting of surgery and trauma. Treatment is usually limited to percutaneous catheterization with a course of antibiotics. As an alternative to current treatment strategies, a histotripsy approach was developed and tested in a novel porcine animal model. The goal of this article is to use advanced ultrasound imaging modes to extract sonographic features associated with the progression of abscess development in a porcine model. Intramuscular or subcutaneous injections of a bi-microbial bacteria mixture plus dextran particles as an irritant led to identifiable abscesses over a 2 to 3 wk period. Selected abscesses were imaged at least weekly with B-mode, 3-D B-mode, shear-wave elastography and plane-wave Doppler imaging. Mature abscesses were characterized by a well-defined core of varying echogenicity surrounded by a hypoechoic capsule that was highly vascularized on Doppler imaging. 3-D imaging demonstrated the natural history of abscess morphology, with the abscess becoming less complex in shape and increasing in volume. Furthermore, shear-wave elastography demonstrated variations in stiffness as phlegmon becomes abscess and then liquefies, over time. These ultrasound features potentially provide biomarkers to aid in selection of treatment strategies for abscesses.


Asunto(s)
Absceso/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Diagnóstico por Imagen de Elasticidad , Femenino , Imagenología Tridimensional , Porcinos , Ultrasonografía , Ultrasonografía Doppler
13.
Ultrasound Med Biol ; 47(3): 603-619, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33250219

RESUMEN

Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical washout when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound (i.e., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.


Asunto(s)
Absceso/terapia , Ultrasonido Enfocado de Alta Intensidad de Ablación , Ultrasonografía Intervencional , Animales , Modelos Animales de Enfermedad , Femenino , Proyectos Piloto , Porcinos
14.
Cardiovasc Ultrasound ; 8: 39, 2010 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-20822530

RESUMEN

INTRODUCTION: Serial monitoring of patients participating in clinical trials of carotid artery therapy requires noninvasive precision methods that are inexpensive, safe and widely available. Noninvasive ultrasonic duplex Doppler velocimetry provides a precision method that can be used for recruitment qualification, pre-treatment classification and post treatment surveillance for remodeling and restenosis. The University of Washington Ultrasound Reading Center (UWURC) provides a uniform examination protocol and interpretation of duplex Doppler velocity measurements. METHODS: Doppler waveforms from 6 locations along the common carotid and internal carotid artery path to the brain plus the external carotid and vertebral arteries on each side using a Doppler examination angle of 60 degrees are evaluated. The UWURC verifies all measurements against the images and waveforms for the database, which includes pre-procedure, post-procedure and annual follow-up examinations. Doppler angle alignment errors greater than 3 degrees and Doppler velocity measurement errors greater than 0.05 m/s are corrected. RESULTS: Angle adjusted Doppler velocity measurements produce higher values when higher Doppler examination angles are used. The definition of peak systolic velocity varies between examiners when spectral broadening due to turbulence is present. Examples of measurements are shown. DISCUSSION: Although ultrasonic duplex Doppler methods are widely used in carotid artery diagnosis, there is disagreement about how the examinations should be performed and how the results should be validated. In clinical trails, a centralized reading center can unify the methods. Because the goals of research examinations are different from those of clinical examinations, screening and diagnostic clinical examinations may require fewer velocity measurements.


Asunto(s)
Centros Médicos Académicos/métodos , Estenosis Carotídea/diagnóstico por imagen , Ensayos Clínicos como Asunto , Guías de Práctica Clínica como Asunto/normas , Consulta Remota/métodos , Ultrasonografía Doppler Dúplex/normas , Humanos , Reproducibilidad de los Resultados , Washingtón
15.
Vasc Endovascular Surg ; 53(7): 529-535, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31230589

RESUMEN

OBJECTIVE: We developed a duplex ultrasound simulator and used it to assess accuracy of volume flow measurements in dialysis access fistula (DAF) models. METHODS: The simulator consists of a mannequin, computer, and mock transducer. Each case is built from a patient's B-mode images that are used to create a 3-dimensional surface model of the DAF. Computational fluid dynamics is used to determine blood flow velocities based on model vessel geometry. The simulator displays real-time B-mode and color-flow images, and Doppler spectral waveforms are generated according to user-defined settings. Accuracy was assessed by scanning each case and measuring volume flow in the inflow artery and outflow vein for comparison with true volume flow values. RESULTS: Four examiners made 96 volume flow measurements on four DAF models. Measured volume flow deviated from the true value by 35 ± 36%. Mean absolute deviation from true volume flow was lower for arteries than veins (22 ± 19%, N = 48 vs. 58 ± 33%, N = 48, p < 0.0001). This finding is attributed to eccentricity of outflow veins which resulted in underestimating true cross-sectional area. Regression analysis indicated that error in measuring cross-sectional area was a predictor of error in volume flow measurement (ß = 0.948, p < 0.001). Volume flow error was reduced from 35 ± 36% to 9 ± 8% (p < 0.000001) by calculating vessel area as an ellipse. CONCLUSIONS: Duplex volume flow measurements are based on a circular vessel shape. DAF inflow arteries are circular, but outflow veins can be elliptical. Simulation-based analysis showed that error in measuring volume flow is mainly due to assumption of a circular vessel.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Simulación por Computador , Maniquíes , Modelos Cardiovasculares , Diálisis Renal , Extremidad Superior/irrigación sanguínea , Velocidad del Flujo Sanguíneo , Humanos , Hidrodinámica , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Transductores , Ultrasonografía Doppler en Color/instrumentación
16.
Environ Health Perspect ; 116(7): 937-42, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18629317

RESUMEN

BACKGROUND: Traffic-related air pollution is consistently associated with cardiovascular morbidity and mortality. Recent human and animal studies suggest that exposure to air pollutants affects vascular function. Diesel exhaust (DE) is a major source of traffic-related air pollution. OBJECTIVES: Our goal was to study the effects of short-term exposure to DE on vascular reactivity and on mediators of vascular tone. METHODS: In a double-blind, crossover, controlled exposure study, 27 adult volunteers (10 healthy and 17 with metabolic syndrome) were exposed in randomized order to filtered air (FA) and each of two levels of diluted DE (100 or 200 microg/m(3) of fine particulate matter) in 2-hr sessions. Before and after each exposure, we assessed the brachial artery diameter (BAd) by B-mode ultrasound and collected blood samples for endothelin-1 (ET-1) and catecholamines. Postexposure we also assessed endothelium-dependent flow-mediated dilation (FMD). RESULTS: Compared with FA, DE at 200 microg/m(3) elicited a decrease in BAd (0.11 mm; 95% confidence interval, 0.02-0.18), and the effect appeared linearly dose related with a smaller effect at 100 microg/m(3). Plasma levels of ET-1 increased after 200 microg/m(3) DE but not after FA (p = 0.01). There was no consistent impact of DE on plasma catecholamines or FMD. CONCLUSIONS: These results demonstrate that short-term exposure to DE is associated with acute endothelial response and vasoconstriction of a conductance artery. Elucidation of the signaling pathways controlling vascular tone that underlie this observation requires further study.


Asunto(s)
Arteria Braquial/efectos de los fármacos , Exposición por Inhalación/efectos adversos , Síndrome Metabólico/fisiopatología , Material Particulado/toxicidad , Vasoconstricción/efectos de los fármacos , Emisiones de Vehículos/toxicidad , Adulto , Arteria Braquial/diagnóstico por imagen , Arteria Braquial/fisiopatología , Catecolaminas/metabolismo , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Endotelina-1/metabolismo , Femenino , Humanos , Masculino , Síndrome Metabólico/metabolismo , Persona de Mediana Edad , Factores de Tiempo , Ultrasonografía , Vasodilatación/efectos de los fármacos
17.
Ultrasound Med Biol ; 34(8): 1200-8, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18336991

RESUMEN

Tissue pulsatility imaging (TPI) is an ultrasonic technique that is being developed at the University of Washington to measure tissue displacement or strain as a result of blood flow over the cardiac and respiratory cycles. This technique is based in principle on plethysmography, an older nonultrasound technology for measuring expansion of a whole limb or body part due to perfusion. TPI adapts tissue Doppler signal processing methods to measure the "plethysmographic" signal from hundreds or thousands of sample volumes in an ultrasound image plane. This paper presents a feasibility study to determine if TPI can be used to assess cerebral vasoreactivity. Ultrasound data were collected transcranially through the temporal acoustic window from four subjects before, during and after voluntary hyperventilation. In each subject, decreases in tissue pulsatility during hyperventilation were observed that were statistically correlated with the subject's end-tidal CO2 measurements. (


Asunto(s)
Circulación Cerebrovascular , Hiperventilación/diagnóstico por imagen , Ultrasonografía Doppler Transcraneal , Adulto , Arteriolas/fisiopatología , Fenómenos Biomecánicos , Estudios de Factibilidad , Humanos , Hiperventilación/fisiopatología , Hipocapnia/fisiopatología , Modelos Lineales , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Resistencia Vascular
18.
Ultrasound Med Biol ; 44(8): 1712-1720, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29793851

RESUMEN

We developed a duplex ultrasound simulator for training and assessment of scanning skills. We used the simulator to test examiner performance in the measurement of flow velocities in dialysis access fistulas. Test cases were created from 3-D ultrasound scans of two dialysis access fistulas by reconstructing 3-D blood vessel models and simulating blood flow velocity fields within the lumens. The simulator displays a 2-D B-mode or color Doppler image corresponding to transducer position on a mannequin; a spectral waveform is generated according to Doppler sample volume location and system settings. Examiner performance was assessed by comparing the measured peak systolic velocity (PSV) with the true PSV provided by the computational flow model. The PSV measured by four expert examiners deviated from the true value by 7.8 ± 6.1%. The results indicate the ability of the simulator to objectively assess an examiner's measurement accuracy in complex vascular targets.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Competencia Clínica/estadística & datos numéricos , Simulación por Computador , Riñón/diagnóstico por imagen , Diálisis Renal/instrumentación , Ultrasonografía Doppler Dúplex/métodos , Velocidad del Flujo Sanguíneo , Oclusión de Injerto Vascular/diagnóstico por imagen , Imagenología Tridimensional/métodos , Riñón/irrigación sanguínea , Maniquíes , Modelos Biológicos , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Ultrasonido/educación
19.
BMC Cardiovasc Disord ; 7: 11, 2007 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-17376239

RESUMEN

BACKGROUND: In order to establish a consistent method for brachial artery reactivity assessment, we analyzed commonly used approaches to the test and their effects on the magnitude and time-course of flow mediated dilation (FMD), and on test variability and repeatability. As a popular and noninvasive assessment of endothelial function, several different approaches have been employed to measure brachial artery reactivity with B-mode ultrasound. Despite some efforts, there remains a lack of defined normal values and large variability in measurement technique. METHODS: Twenty-six healthy volunteers underwent repeated brachial artery diameter measurements by B-mode ultrasound. Following baseline diameter recordings we assessed endothelium-dependent flow mediated dilation by inflating a blood pressure cuff either on the upper arm (proximal) or on the forearm (distal). RESULTS: Thirty-seven measures were performed using proximal occlusion and 25 with distal occlusion. Following proximal occlusion relative to distal occlusion, FMD was larger (16.2 +/- 1.2% vs. 7.3 +/- 0.9%, p < 0.0001) and elongated (107.2 s vs. 67.8 s, p = 0.0001). Measurement of the test repeatability showed that differences between the repeated measures were greater on average when the measurements were done using the proximal method as compared to the distal method (2.4%; 95% CI 0.5-4.3; p = 0.013). CONCLUSION: These findings suggest that forearm compression holds statistical advantages over upper arm compression. Added to documented physiological and practical reasons, we propose that future studies should use forearm compression in the assessment of endothelial function.


Asunto(s)
Presión Sanguínea/fisiología , Arteria Braquial/fisiología , Vasodilatación/fisiología , Adulto , Brazo/irrigación sanguínea , Determinación de la Presión Sanguínea/métodos , Arteria Braquial/diagnóstico por imagen , Endotelio Vascular/fisiología , Femenino , Antebrazo/irrigación sanguínea , Humanos , Masculino , Flujo Sanguíneo Regional/fisiología , Reproducibilidad de los Resultados , Factores de Tiempo , Ultrasonografía
20.
Ultrasound Med Biol ; 33(5): 681-90, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17346872

RESUMEN

Functional tissue pulsatility imaging is a new ultrasonic technique being developed to map brain function by measuring changes in tissue pulsatility as a result of changes in blood flow with neuronal activation. The technique is based in principle on plethysmography, an older, nonultrasound technology for measuring expansion of a whole limb or body part as a result of perfusion. Perfused tissue expands by a fraction of a percent early in each cardiac cycle when arterial inflow exceeds venous outflow, and it relaxes later in the cardiac cycle when venous drainage dominates. Tissue pulsatility imaging (TPI) uses tissue Doppler signal processing methods to measure this pulsatile "plethysmographic" signal from hundreds or thousands of sample volumes in an ultrasound image plane. A feasibility study was conducted to determine if TPI could be used to detect regional brain activation during a visual contrast-reversing checkerboard block paradigm study. During a study, ultrasound data were collected transcranially from the occipital lobe as a subject viewed alternating blocks of a reversing checkerboard (stimulus condition) and a static, gray screen (control condition). Multivariate analysis of variance was used to identify sample volumes with significantly different pulsatility waveforms during the control and stimulus blocks. In 7 of 14 studies, consistent regions of activation were detected from tissue around the major vessels perfusing the visual cortex.


Asunto(s)
Encéfalo/fisiología , Ecoencefalografía/métodos , Estimulación Luminosa/métodos , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Ultrasonografía Doppler Transcraneal/métodos , Corteza Visual/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA