Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Herz ; 46(Suppl 2): 166-172, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32880663

RESUMEN

BACKGROUND: Some patients referred for transcatheter aortic valve replacement (TAVR) have excessively large annuli (ELA) without device options according to current sizing charts. This retrospective study aims to summarize the presentation and outcomes of ELA patients receiving first-generation self-expanding valves. METHODS: The TAVR database was reviewed in search for cases of self-expanding valves. Patients who had annuli exceeding the perimeter limit on the device sizing chart were referred to as the ELA group. Patients who had annuli within the range covered by the two largest sizes and received the corresponding valve size served as the control group (CG). Baseline, procedures, outcomes, and imaging characteristics on multislice computed tomography (MSCT), such as native anatomy and postimplant stent geometry, were compared. RESULTS: A total of 28 patients were included in the ELA group and 82 in the CG. The patients in the ELA group were younger than those in the CG (72.5 ± 6.2 vs. 75.4 ± 5.8 years, P = 0.03). The median intended perimeter oversizing in relation to the annulus in the ELA group was much smaller than in the CG (-0.4 [-4.6, 4.1] % vs. 16.1 [11.7, 20.8] %, P < 0.01). The calcium burden in the aortic root was around 1.3-fold greater in the ELA group than the CG (756.0 [534.5, 1670.9] vs. 582.1 [310.3, 870.9] mm3, P = 0.01). The need for second valve implantation was higher in ELA (21.4% vs. 12.2%, P = 0.23) but no valve embolization was encountered. The 1­year follow-up was comparable, including >mild paravalvular leak. CONCLUSION: Under cautious patient selection using MSCT, TAVR with self-expanding valves in patients with ELA appears feasible. Supra-annular structures likely provide the extra anchoring.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 96(7): 1491-1497, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32400115

RESUMEN

OBJECTIVE: We hypothesize that different degree of pre-existing aortic regurgitation (AR) may affect the presence of hypo-attenuated leaflet thickening (HALT) after transcatheter aortic valve replacement (TAVR). BACKGROUND: The mechanism of the presence of HALT post-TAVR is not fully understood. METHODS: We retrospectively evaluated the post-procedural multi-slice computed tomography (MSCT) before discharge for evidence of HALT. Patients were grouped according to the degree of pre-existing AR. Baseline, native anatomy and procedure details were compared, then multivariate regression was performed. RESULTS: MSCT analyzed was performed at a median of 6 days post-TAVR in 179 patients. HALT was detected in 10.6% of patients. After adjusting for variables that were significantly different between groups, pre-existing ≥ moderate AR was protective to the risk of HALT (OR 0.15, 95% CI 0.03-0.84, p = .03). Stratifying for factors that might explain the impact of pre-existing AR on HALT, patients with a small Sinus of Valsalva, non-eccentric remodeling and receiving a large bioprosthesis experienced a sevenfold higher risk for HALT (OR 7.16, 95% CI 2.05-25.08, p = .002). CONCLUSIONS: Patients underwent TAVR with pre-existing ≥ moderate AR appeared to experience a lower incidence of early HALT compared to those patients with less than moderate AR, which may be explained by a larger Sinus of Valsalva and a higher proportion of LV eccentric remodeling.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
3.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31943783

RESUMEN

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Femenino , Humanos , Masculino , Proyectos Piloto , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
BMC Cardiovasc Disord ; 20(1): 229, 2020 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-32423380

RESUMEN

BACKGROUND: To explore why bicuspid aortic stenosis has certain clinical differences from the tricuspid morphology, we evaluated the metabolomics profile involved in bicuspid aortic valve (BAV) aortic stenosis prior to and after transcatheter aortic valve replacement (TAVR) in comparison with tricuspid aortic valve (TAV). METHODS: In this TAVR cohort with prospectively collected data, blood samples were obtained before TAVR valve deployment and at the 7th day after TAVR, which were then sent for liquid and gas chromatography-mass spectrometry detection. Besides comparisons between BAV and TAV, BAV patients were also divided in subgroups according to baseline hemodynamics (i.e. maximal transaortic velocity, Vmax) and post-procedural reverse left ventricular (LV) remodeling (i.e. the change in LV mass index from baseline, ∆LVMI) for further analysis. Metabolic differences between groups were identified by integrating univariate test, multivariate analysis and weighted correlation network analysis algorithm. RESULTS: A total of 57 patients were enrolled including 33 BAV patients. The BAV group showed lower arginine and proline metabolism both before and post TAVR than TAV represented by decreased expression of L-Glutamine. In BAV subgroup analysis, patients with baseline Vmax > 5 m/s (n = 11) or the 4th quartile of change in ∆LVMI at one-year follow-up (i.e. poorly-recovered LV, n = 8) showed elevated arachidonic acid metabolism compared with Vmax < 4.5 m/s (n = 12) or the 1st quartile of ∆LVMI (i.e. well-recovered LV, n = 8) respectively. CONCLUSIONS: Difference in arginine and proline metabolism was identified between BAV and TAV in TAVR recipients. Elevated arachidonic acid metabolism may reflect more severe baseline hemodynamics and worse LV reserve remodeling after TAVR in BAV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Metabolismo Energético , Enfermedades de las Válvulas Cardíacas/cirugía , Metabolómica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Ácido Araquidónico/sangre , Arginina/sangre , Enfermedad de la Válvula Aórtica Bicúspide , Biomarcadores/sangre , Femenino , Enfermedades de las Válvulas Cardíacas/sangre , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Masculino , Prolina/sangre , Estudios Prospectivos , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
5.
J Cell Mol Med ; 23(11): 7673-7684, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31468674

RESUMEN

Stromal cell-derived factor-1 (SDF-1) is a well-characterized cytokine that protects heart from ischaemic injury. However, the beneficial effects of native SDF-1, in terms of promoting myocardial repair, are limited by its low concentration in the ischaemic myocardium. Annexin V (AnxA5) can precisely detect dead cells in vivo. As massive cardiomyocytes die after MI, we hypothesize that AnxA5 can be used as an anchor to carry SDF-1 to the ischaemic myocardium. In this study, we constructed a fusion protein consisting of SDF-1 and AnxA5 domains. The receptor competition assay revealed that SDF-1-AnxA5 had high binding affinity to SDF-1 receptor CXCR4. The treatment of SDF-1-AnxA5 could significantly promote phosphorylation of AKT and ERK and induce chemotactic response, angiogenesis and cell survival in vitro. The binding membrane assay and immunofluorescence revealed that AnxA5 domain had the ability to specifically recognize and bind to cells injured by hypoxia. Furthermore, SDF-1-AnxA5 administered via peripheral vein could accumulate at the infarcted myocardium in vivo. The treatment with SDF-1-AnxA5 attenuated cell apoptosis, enhanced angiogenesis, reduced infarcted size and improved cardiac function after mouse myocardial infarction. Our results suggest that the bifunctional SDF-1-AnxA5 can specifically bind to dead cells. The systemic administration of bifunctional SDF-1-AnxA5 effectively provides cardioprotection after myocardial infarction.


Asunto(s)
Anexina A5/metabolismo , Quimiocina CXCL12/metabolismo , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/fisiopatología , Proteínas Recombinantes de Fusión/uso terapéutico , Administración Intravenosa , Animales , Muerte Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Quimiotaxis/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Masculino , Ratones Endogámicos C57BL , Infarto del Miocardio/patología , Isquemia Miocárdica/fisiopatología , Miocardio/metabolismo , Miocardio/patología , Neovascularización Fisiológica/efectos de los fármacos , Unión Proteica/efectos de los fármacos , Receptores de Quimiocina/metabolismo , Proteínas Recombinantes de Fusión/administración & dosificación , Proteínas Recombinantes de Fusión/farmacología , Transducción de Señal/efectos de los fármacos
6.
J Interv Cardiol ; 2019: 7348964, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31777470

RESUMEN

OBJECTIVES: We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion. BACKGROUND: It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS. METHODS: This retrospective study enrolled consecutive patients with severe symptomatic AS and type-0 bicuspid aortic valve, who underwent TAVR at our institution between 2012 and 2017. TAVR outcomes were defined based on the Valve Academic Research Consortium-2 recommendations. RESULTS: Compared to patients with mixed cusp fusion (44/71), those with coronary cusp fusion (27/71) had a larger ellipticity index for the aortic annulus (21.9% ± 9.0% vs 15.6% ± 9.3%, p=0.007) and increased left ventricular outflow tract obstruction (31.1% ± 9.4% vs 26.9% ± 7.5%, p=0.04) but comparable rates of second valve implantation (15.9% vs 14.8%), mild paravalvular leakage (PVL, 38.5% vs 30.2%), permanent pacemaker implantation (PPM, 25.9% vs 15.9%), and 30-day mortality (7.4% vs 6.8%). Use of a first-generation transcatheter heart valve was associated with higher risk for mild PVL (odds ratio (OR) = 4.37; 95% confidence interval (95% CI) = 1.14-16.75; p=0.03) but not PPM (OR = 0.77; 95% CI = 0.22-2.62; p=0.67), whereas a larger oversizing ratio tended to be associated with a higher PPM rate (OR = 1.49; 95% CI = 0.46-4.86; p=0.51) but lower incidence of mild PVL (OR = 0.51; 95% CI = 0.19-1.35; p=0.17). CONCLUSIONS: In AS patients with type-0 bicuspid valves, cusp fusion morphology does not affect the procedural or clinical results of TAVR. Use of second-generation transcatheter heart valves may provide more favorable results in such patients. This trial is registered with NCT01683474.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Humanos , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis
7.
Lipids Health Dis ; 18(1): 21, 2019 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-30670053

RESUMEN

BACKGROUND: The role of triglyceride (TG) in secondary prevention of patients with coronary artery disease (CAD) was debated. In the present study, we assessed the association between admission TG levels and long-term mortality risk in CAD patients. METHODS: A retrospective analysis was conducted from a single registered database. 3061 consecutive patients with CAD confirmed by coronary angiography were enrolled and were grouped into 3 categories by the tertiles of admission serum TG levels. The primary end point in this study was all-cause mortality and the secondary end point was cardiovascular mortality. RESULTS: The mean follow-up time was 26.9 ± 13.6 months and death events occurred in 258 cases and cardiovascular death events occurred in 146 cases. Cumulative survival curves indicated that the risk of all-cause death decreased with increasing TG level (Tertile 1 vs. Tertile 2 vs. Tertile 3 = 10.3% vs. 8.6% vs. 6.3%, log rank test for overall p = 0.001). Cox regression analysis showed an independent correlation between TG level and risk of all-cause mortality [hazard ratio (HR) 0.71, 95% confidence interval (CI) 0.58-0.86] and cardiovascular mortality (HR 0.67, 95% CI 0.51-0.89) in total patients with CAD. Subgroup analysis found the similar results in patients with acute coronary syndrome and acute myocardial infarction. CONCLUSIONS: This study found an inverse association between TG levels and mortality risk in CAD patients, which suggests that the "TG paradox" may exist in CAD patients. TRIAL REGISTRATION: ChiCTR, ChiCTR-OOC-17010433 . Registered 17 February 2017 - Retrospectively registered.


Asunto(s)
Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/mortalidad , Triglicéridos/sangre , Anciano , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad
8.
J Interv Cardiol ; 31(6): 878-884, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30079561

RESUMEN

BACKGROUND: Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS: A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS: The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS: Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Asunto(s)
Válvula Aórtica/anomalías , Arritmias Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Arritmias Cardíacas/etiología , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Incidencia , Masculino , Tomografía Computarizada Multidetector , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
9.
J Thromb Thrombolysis ; 45(3): 463-465, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29478129

RESUMEN

The imaging finding of hypo-attenuated leaflet thickening (HALT) on bioprosthesis after transcatheter aortic valve replacement (TAVR) has been reported. The underlying mechanism is not clear, but leaflet thrombosis is speculated to be the cause. Heterogeneous antiplatelet responses may play a role in the process. This is a prospective, single-center pilot study in patients who received successful TAVR from June 2012 to November 2016. HALT on post-procedural multi-detector computed tomography. We thoroughly genotyped 34 SNPs and 8 SNPs that have been reported for clopidogrel and aspirin resistance. A total of 148 patients were enrolled. There were 15 patients demonstrating signs of HALT. Patients with HALT had a higher rate of atrial fibrillation (AF) pre-TAVR (33.3 vs. 7.5%, P = 0.01). We found that rs4244285 G>A polymorphism of the CYP2C19 gene was associated with the risk of HALT in the overdominant model (OR 4.00 [1.15-13.97], P = 0.02 for GA vs. GG+AA) adjusted by sex and the presence of pre-TAVR AF. Antiplatelet drug resistance is a reasonable possibility involved in HALT. Potential directions were suggested in polymorphisms of the CYP2C19 gene.


Asunto(s)
Inhibidores de Agregación Plaquetaria/uso terapéutico , Polimorfismo de Nucleótido Simple , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Aspirina/farmacología , Aspirina/uso terapéutico , Clopidogrel , Citocromo P-450 CYP2C19/genética , Resistencia a Medicamentos/genética , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Ticlopidina/análogos & derivados , Ticlopidina/farmacología , Ticlopidina/uso terapéutico
10.
Aging Clin Exp Res ; 30(9): 1071-1077, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29260400

RESUMEN

BACKGROUND: Statins therapy in the secondary prevention of coronary artery disease (CAD) is associated with a lower risk of adverse cardiovascular events. However, little is known regarding the association of elderly patients with nutritional risk on statin therapy. AIMS: To investigate whether older patients with CAD who were at nutritional risk gain similar survival benefit from statins therapy as their counterparts without nutritional risk. METHODS: We conducted a retrospective hospital-based cohort study among 1705 patients with CAD who were older than 65 years of age, using coronary heart disease database from 2008 to 2012. Nutritional status of included patients was gauged using the geriatric nutritional risk index. After stratification by nutritional status, the hazard of all-cause death was compared between those with or without statins therapy. RESULTS: Of the 1705 patients included in the study (mean age 72 years; 73% male), all-cause death occurred in 146 (9.2%) patients with statins use and in 33 (26.2%) patients without statins use. The rate of all-cause death was higher in patients not receiving statins irrespective of nutritional status. After adjustments for potential confounders, the HR with statins use was 0.33 (95% CI 0.20-0.55) in patients without nutritional risk and 0.47 (95% CI 0.22-1.00) in patients with nutritional risk. No interaction effect was detected between nutritional status and statins use in relation to all-cause death (P value for interaction effect 0.516). CONCLUSION: Despite of the patient's nutritional status, statins therapy as a secondary prevention in elderly CAD patients was associated with decreased risk of all-cause death.


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Estado Nutricional , Anciano , Causas de Muerte , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Prevención Secundaria/métodos
11.
Heart Lung Circ ; 27(4): e46-e50, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29198572

RESUMEN

Bioprosthesis thrombosis after transcatheter aortic valve replacement (TAVR) raised concerns about further clinical events. We report the case of a patient who suffered acute myocardial infarction (AMI) after TAVR for 3 years. Thrombosis was confirmed in the right coronary sinus of Valsalva by transthoracic echocardiography. Coronary angiography demonstrated the ostium of the right coronary artery was occluded. As an attempt to perform percutaneous coronary intervention (PCI) was unsuccessful, long-term therapeutic anticoagulation with warfarin was undertaken. Within 2 weeks, symptoms were relieved, and the right coronary ostium thrombus disappeared on computed tomography (CT) angiography. This case highlights the AMI as initial manifestation of delayed bioprosthesis thrombosis and the importance of anticoagulation against the bioprosthesis thrombosis. Meanwhile, the difficulty of PCI after TAVR is not only the stent frame of bioprosthesis, but also the location of the thrombosis.


Asunto(s)
Bioprótesis/efectos adversos , Cardiopatías/complicaciones , Infarto del Miocardio con Elevación del ST/etiología , Trombosis/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Electrocardiografía , Cardiopatías/diagnóstico , Cardiopatías/terapia , Humanos , Masculino , Intervención Coronaria Percutánea/métodos , Falla de Prótesis , Reoperación , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Terapia Trombolítica , Trombosis/diagnóstico
12.
Catheter Cardiovasc Interv ; 89(S1): 528-533, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28318133

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A-Valve and the CoreValve; however, there is no data on their comparative performance. METHODS: Consecutive patients undergoing TAVI with the aforementioned devices were included. The outcomes were reported according to the Valve Academic Research Consortium-2 (VARC) definitions. RESULTS: A total of 54 TAVI procedures were performed, 27 with the CoreValve and the other 27 with the Venus A-Valve. An additional valve was required in 4 (14.8%) and 3 (11.1%) patients, and the VARC-2 device success rates were 81.5 and 85.2%, respectively. The incidences of common complications were similar, except for the significantly less frequent pacemaker insertion in the Venus A-Valve group (7.4 vs. 37.0%, P = 0.03). Within 30 days, 2 (3.7%) patients died, 1 in each group, and both had a bicuspid aortic valve (BAV). No other serious complications, such as annular rupture, coronary obstruction and aortic dissection, occurred in the 32 BAV patients treated with the Venus A-Valve (14) or the CoreValve (18). After 2-years of follow-up, there was no significant difference between CoreValve group and Venus-A group (11.1 vs. 7.4%, P = 0.64). CONCLUSION: TAVI with the domestic Venus A-Valve is feasible, safe, and can produce favorable short-term outcomes comparable to those with the CoreValve in inoperable or high-risk patients with tricuspid and bicuspid aortic valve stenosis. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , China , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
13.
Cardiovasc Diabetol ; 15(1): 106, 2016 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-27484994

RESUMEN

OBJECTIVE: We try to analyse the effect of renal functions on death in CAD patients with different body compositions. METHODS: A retrospective analysis was conducted in 2989 consecutive patients with CAD confirmed by coronary angiography were enrolled and were grouped into two categories: basically preserved renal function (PRF) (eGFR ≥60 ml/min) and obviously reduced renal function (RRF) (eGFR <60 ml/min). The influence of renal insufficiency on mortality of CAD was detected in every tertile of body composition, including body mass index (BMI), body fat (BF) and lean mass index (LMI). The end points were all-cause mortality. RESULTS: The mean follow-up time was 29.1 ± 12.5 months and death events occurred in 271 cases. The percentage of patients with RRF was positively correlated with BF and inversely correlated with the LMI, but no relationship to BMI. The survival curves showed that the risk of death was significantly higher in the RRF patients in all subgroups stratified using BMI, BF, or LMI (log rank test, all p < 0.001). The COX multivariate regression analysis showed that the risk of death was significantly higher in the RRF patients with high BF (HR 1.95, CI 1.25-3.05) and low LMI (HR 1.82, CI 1.19-2.79). Meanwhile, risk of death was significantly higher in RRF patients with a high BMI (HR 2.08, CI 1.22-3.55) or low BMI (HR 1.98, CI 1.28-3.08) but this risk was not significant in patients with a medium BMI (HR 1.12, 0.65-1.94). The subgroup analysis of patients with acute coronary syndrome (ACS) showed similar results. CONCLUSIONS: For patients with CAD, renal insufficiency was positively correlated with BF, inversely correlated with LMI, and unrelated to BMI. The effect of renal insufficiency on the risk of death of CAD was related to body composition.


Asunto(s)
Composición Corporal/fisiología , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Riñón/fisiopatología , Obesidad/complicaciones , Adulto , Anciano , Índice de Masa Corporal , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico , Pronóstico , Estudios Retrospectivos
14.
Catheter Cardiovasc Interv ; 87 Suppl 1: 570-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26856312

RESUMEN

OBJECTIVE: The present study was performed to investigate the relationship between chronic obstructive pulmonary disease (COPD) and transcatheter aortic valve implantation (TAVI). BACKGROUND: Controversies regarding the relationship between COPD and TAVI have intensified. METHODS: A literature review of the PubMed online database was performed, and articles published between January 1, 2002 and March 20, 2015 were analyzed. Random-effect and fixed-effect models were used, depending on the between-study heterogeneity. RESULTS: A total of 28 studies, involving 51,530 patients, were identified in our review. The burden of COPD ranged from 12.5% to 43.4%, and COPD negatively impacted both short-term and long-term all-cause survival (30 days: odds ratio [OR], 1.43, 95% CI, 1.14-1.79; >2 years: hazard ratio [HR], 1.34, 95% CI, 1.12-1.61). COPD was also associated with increased short-term and mid-term cardiac-cause mortality (30 days: OR, 1.29, 95% CI, 1.02-1.64; 1 year: HR: 1.09, 1.02-1.17). Moreover, COPD (OR, 1.97, 95% CI, 1.29-3.0) predicted post-TAVI acute kidney disease. Importantly, chronic kidney disease (CKD) (HR, 1.2, 95% CI, 1.1-1.32) and the distance of the 6 minute walk test (6MWT) (HR, 1.16, 1.06-1.27) predicted TAVI futility in patients with COPD. CONCLUSION: COPD is common among patients undergoing TAVI, and COPD impacts both short- and long-term survival. COPD patients, who had a lower BMI, shorter distance of 6MWT and CKD, were at higher risk for TAVI futility.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Lesión Renal Aguda/epidemiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Índice de Masa Corporal , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Comorbilidad , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Modelos Logísticos , Pulmón/fisiopatología , Masculino , Análisis Multivariante , Oportunidad Relativa , Prevalencia , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Insuficiencia Renal Crónica/epidemiología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Caminata
15.
J Cardiovasc Pharmacol ; 66(5): 468-77, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26222993

RESUMEN

BACKGROUND: Bisphosphonates have shown potential to inhibit atherosclerosis in animal experiments; however, whether bisphosphonates therapy lowers the risk of incidence of myocardial infarction (MI) is debated. We performed the meta-analysis and trial sequential analysis (TSA) to investigate the relation between bisphosphonates therapy and incident MI. METHODS: Pubmed and Embase databases were systematically searched in April 2015 to identify studies, which compared the incidence of MI in subjects receiving bisphosphonates with that in subjects not receiving the agents. Meta-analysis was conducted using random effects model in consideration of statistical heterogeneity between studies. Reliability of the results from meta-analysis was examined using TSA. RESULTS: Six observational studies (n = 440261) and 3 randomized control trials (RCTs, n = 11,024) met the eligible criteria. In the pooled analysis of observational studies, bisphosphonates therapy was not associated with reduced risk of MI either using unadjusted estimates (relative risk 0.93, 95% confidence interval (CI), 0.75-1.15) or estimates adjusted for confounding factors (hazard ratio 1.01, 95% CI, 0.84-1.21). Furthermore, hazard of incident MI did not differ between alendronate users and nonusers. TSA showed that evidence from observational studies firmly precluded the association between bisphosphonates and incident MI. Pooled analysis of RCTs also suggested no benefits of decrease in incident MI associated with bisphosphonates therapy (relative risk 1.05, 95% CI, 0.53-2.09). However, TSA demonstrated that evidence from RCTs was insufficient to draw a conclusion. CONCLUSIONS: Despite the encouraging findings from animal studies, bisphosphonates therapy is not associated with reduced risk of MI.


Asunto(s)
Difosfonatos/uso terapéutico , Infarto del Miocardio/prevención & control , Humanos , Incidencia , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Oportunidad Relativa , Factores Protectores , Medición de Riesgo , Factores de Riesgo
16.
Herz ; 40(8): 1097-106, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26115740

RESUMEN

BACKGROUND: Studies focusing on the relationship between calcified lesions and adverse outcomes in the drug-eluting stent (DES) era have presented inconsistent conclusions. The aim of this study was to assess the association between target lesion calcification and adverse outcomes in patients undergoing DES implantation. METHODS: A systematic search was conducted on Medline (Ovid SP, 1946 to 28 February 2014), Embase (Ovid SP, 1974 to 28 February 2014), and the Chinese Biomedical Literature Database (CBM, 1978 to 28 February 2014). Abstracts from the 2012 and 2013 scientific meetings of the American College of Cardiology and American Heart Association were manually searched. Hazard ratios (HRs) were pooled using a fixed or random effects model in the context of heterogeneity. RESULTS: A total of 13 studies comprising 66,361 patients were included. Target lesion calcification was associated with an increased risk of all-cause mortality (HR = 1.41; 95 % CI = 1.27-1.56), cardiac death (HR = 1.97; 95 % CI = 1.68-2.31), myocardial infarction (HR = 1.33; 95 % CI = 1.13-1.57), target lesion revascularization (TLR; HR 1.47, 95 % CI 1.18-1.83), stent thrombosis (HR 1.63, 95 % CI 1.36-1.96), and major cardiovascular events (HR 1.37, 95 % CI 1.19-1.58). The results proved robust in subgroup analyses for TLR and stent thrombosis. CONCLUSION: Calcified target lesions are risk factors for adverse outcomes in the DES era. Further studies focusing on comprehensive therapy in patients with coronary calcification are urgently needed.


Asunto(s)
Calcinosis/mortalidad , Calcinosis/terapia , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Causalidad , Comorbilidad , Muerte Súbita Cardíaca/epidemiología , Femenino , Humanos , Incidencia , Masculino , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
17.
Eur J Clin Invest ; 44(10): 893-901, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25104141

RESUMEN

BACKGROUND: A new 4-tired classification of left ventricular hypertrophy (LVH) based on LV concentricity and dilation has been proposed; however, the association between the new categorization of LV geometry and outcomes in patients with coronary artery disease (CAD) is still unknown. METHODS: All the 2297 patients with CAD included underwent echocardiographic examination prior to discharge. Left ventricular mass (LVM) was calculated, and left ventricular end-diastolic volume (EDV) was indexed by body surface area (BSA). Study cohort was divided into five groups according to LV geometry: (i) eccentric nondilated LVH (normal LVM/EDV((2/3)) and EDV/BSA) (n = 129); (ii) eccentric dilated LVH (normal LVM/EDV((2/3)) with increased EDV/BSA) (n = 222); (iii) concentric nondilated LVH (increased LVM/EDV((2/3)) with normal EDV/BSA) (n = 441); (iv) concentric dilated LVH (increased LVM/EDV((2/3)) and EDV/BSA) (n = 118); and (v) normal LV mass (n = 1387). RESULTS: Dilated LVH was associated with a higher event rates of all-cause death (eccentric 13·1% vs. 3·1%; concentric 13·6% vs. 8·4%) and composite events (eccentric: 17·6% vs. 5·4%; concentric: 18·6% vs. 12·7%) compared with nondilated LVH. While eccentric nondilated LVH had comparable risk for adverse outcomes compared with normal LV mass (all-cause death: relative risk (RR) 0·68, 95% confidential interval (CI) 0·25-1·85; composite events: RR 0·75, 95% CI 0·36-1·58). Cox regression analyses showed that eccentric dilated LVH had the highest propensity to all-cause death (adjusted hazard ratio [aHR] 2·752 [95% CI 1·749-4·328], P < 0·001) and composite events (aHR 2·462 [95% CI 1·688-3·592], P < 0·001). CONCLUSION: In patients with CAD, dilated LVH and nondilated LVH provide distinct prognostic information. Eccentric nondilated LVH does not predict adverse outcomes.


Asunto(s)
Hipertrofia Ventricular Izquierda/clasificación , Distribución por Edad , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Ecocardiografía , Métodos Epidemiológicos , Femenino , Humanos , Hipertrofia Ventricular Izquierda/patología , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Pronóstico , Remodelación Ventricular/fisiología
18.
Front Cardiovasc Med ; 9: 794850, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35369357

RESUMEN

Objective: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method: Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results: A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions: Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

19.
JACC Cardiovasc Interv ; 15(16): 1652-1660, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35981839

RESUMEN

BACKGROUND: It is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs). OBJECTIVES: The aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs. METHODS: In this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes. RESULTS: A total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women. CONCLUSIONS: In patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Caracteres Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
J Geriatr Cardiol ; 18(10): 825-835, 2021 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-34754294

RESUMEN

BACKGROUND: The high-degree atrioventricular block (HAVB) in patients with bicuspid aortic valve (BAV) treated with transcatheter aortic valve implantation (TAVI) remains high. The study aims to explore this poorly understood subject of mechanisms and predictors for HAVB in BAV self-expandable TAVI patients. METHODS: We retrospectively included 181 BAV patients for analysis. Using computed tomography data, the curvature of ascending aorta (AAo) was quantified by the angle (AAo angle) between annulus and the cross-section at 35 mm above annulus (where the stent interacts with AAo the most). The valvular anatomy and leaflet calcification were also characterized. RESULTS: The 30-day HAVB rate was 16.0% (median time to HAVB was three days). Type-1 morphology was found in 79 patients (43.6%) (left- and right-coronary cusps fusion comprised 79.7%). Besides implantation below membrane septum, large AAo angle [odds ratio (OR) = 1.08, P = 0.016] and type-1 morphology (OR = 4.97, P = 0.001) were found as the independent predictors for HAVB. Together with baseline right bundle branch block, these predictors showed strong predictability for HAVB with area under the cure of 0.84 (sensitivity = 62.1%, specificity = 92.8%). Bent AAo and calcified raphe had a synergistic effect in facilitating high implantation, though the former is associated with at-risk deployment (device implanted above annulus + prothesis pop-out, versus straight AAo: 9.9% vs. 2.2%, P = 0.031). CONCLUSIONS: AAo curvature and type-1 morphology are novel predictors for HAVB in BAV patients following self-expandable TAVI. For patients with bent AAo or calcified raphe, a progressive approach to implant the device above the lower edge of membrane septum is favored, though should be done cautiously to avoid pop-out.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA