RESUMEN
Circular RNAs (circRNAs) are recently discovered as a special novel type of endogenous noncoding RNAs (ncRNAs), which form a covalently closed continuous loop and are highly represented in the eukaryotic transcriptome. Recent research revealed that circRNAs can function as microRNA (miRNA) sponges, regulators of splicing and transcription, as well as interact with RNA-binding proteins (RBPs). In this review, not only the function and mechanism, but also the experimental methods of circRNA are summarized. The summary of the current state of circRNA will help us in the discovery of novel biomarkers, the therapeutic targets and their potential significance in diagnosis and treatment of diseases. CircRNAs might play important roles in cancers especially in hepatocellular carcinoma, gastric carcinoma and colorectal cancer as well as serving as diagnostic or predictive biomarkers of some diseases and providing new treatments of diseases.
RESUMEN
The issue of the clinical appropriateness of blood transfusion has become a focus of transfusion medicine worldwide. In China, irrational uses of blood have often been reported in recent years. However, to date there lacks a systematic review of the rational uses of blood. This study aimed to determine the clinical appropriateness of blood transfusion in China. We searched PubMed, Web of Science, the Cochrane Library, China National Knowledge Infrastructure (CNKI), China Science and Technology Journal Database, WanFang Database, and Chinese BioMedical Literature Database, and the retrieval cut-off date was June 31, 2015. SPSS 17.0 and MetaAnalyst 3.13 were employed as the statistics tools in this review. A pooled rate of clinical inappropriateness of transfusion was analyzed by DerSimonian-Laird method. In this study, a total of 39 observational studies were included, which related to 75,132 cases of blood transfusion. According to the meta-analysis results, the overall incidence of clinical inappropriateness of transfusion in China was estimated to be 37.3% (95% confidence interval [CI] [32.1, 42.8]). The subgroup analyses revealed that the pooled rates of clinical inappropriateness of transfusion of plasma, red blood cells (RBCs), cryoprecipitate, and platelets were 56.3% (95% CI [45.8, 66.2]), 30.9% (95% CI [27.1, 35.0]), 25.2% (95% CI [13.2, 42.7]), and 14.1% (95% CI [8.8, 21.9]), respectively. However, the pooled incidence of inappropriateness of transfusion in operative departments was 47.5% (95% CI [36.8, 58.3]), which was significantly higher than that in nonoperative departments, 25.8% (95% CI [18.7, 34.4], Pâ<â0.05). The overall rates of inappropriate use were 36.7% (95% CI [30.2, 43.6]) in major cities and 37.5% (95% CI [31.2, 44.3]) in other cities, respectively; there was no statistically significant difference (Pâ>â0.05). In conclusion, China has suffered from a disadvantage in the clinical appropriateness of blood transfusion, especially in plasma and RBC use. In future, comprehensive measures should be implemented in order to improve the clinical appropriateness of blood transfusion.
Asunto(s)
Transfusión Sanguínea/estadística & datos numéricos , Transfusión Sanguínea/normas , Pautas de la Práctica en Medicina/estadística & datos numéricos , Pautas de la Práctica en Medicina/normas , Transfusión de Componentes Sanguíneos , China , Humanos , Estudios Observacionales como Asunto , Calidad de la Atención de SaludRESUMEN
The purpose of this study was to determine whether the fully automated ORTHO AutoVue Innova system, which based on the microcolumn glass sphere technology, is accurate enough to meet immunohematology testing needs at blood banks. 16 IgM anti-C, anti-c, anti-D, anti-E and anti-e dilution series were tested respectively, with corresponding antigen positive red blood cell solutions, by ORTHO AutoVue Innova system and saline medium test. 16 IgG anti-D dilution series were tested respectively with RhD positive red blood cell solutions by ORTHO AutoVue Innova system, polybrene test and antiglobulin test. The accuracies of microcolumn glass sphere technology were analysed, by comparing to the reference assays. The results showed that the sensitivities of the ORTHO AutoVue Innova tests were 1:69.8, 1:33.4, 1:1448.1, 1:139.6 and 1:32.0 for IgM anti-C, anti-c, anti-D, anti-E and anti-e respectively; the corresponding value of saline medium tests were 1:16.7, 1:16.6, 1:430.5, 1:34.9 and 1:9.9. There were statistically significant differences between the groups of each tests (t values were 14.38, 5.48, 10.25, 12.65 and 9.59 for IgM anti-C, anti-c, anti-D, anti-E and anti-e respectively, p < 0.05). For IgG anti-D, the sensitivities of the ORTHO AutoVue Innova test, polybrene test and antiglobulin test were 1:980.6, 1:181.0 and 1:304.4 respectively. There was statistically significant difference among the 3 groups (F = 51.15, p < 0.01). It is concluded the use of ORTHO AutoVue Innova system for blood group compatibility test can obtain more accurate results than traditional tube tests, it is reliable and safe for routine tests performed in immunohematology laboratories.
Asunto(s)
Tipificación y Pruebas Cruzadas Sanguíneas/métodos , Prueba de Coombs/métodos , Isoanticuerpos/sangre , Humanos , Ensayo de Materiales , Globulina Inmune rho(D) , Sensibilidad y EspecificidadRESUMEN
This study was aimed to investigate the relation of human leukocyte antigen-A, B, DRB1 genes with the susceptibility of population to leukemia in Anhui province of China. The HLA genotypes were analyzed by PCR-SSP in 140 patients with chronic myelocytic leukemia (CML), 84 patients with acute lymphoblastic leukemia (ALL), 90 patients with acute nonlymphocytic leukemia (ANLL) and 916 healthy unrelated donors of hematopoietic stem cell as normal control admitted to Anhui provincial hospital. The gene frequencies of HLA-A, B, DRB1 between patients and normal controls were compared, chi² test was used for statistical analysis. The results showed that as compared with normal controls, the gene frequencies of A2, A11, B58 and DR9 in CML patients all obviously increased, and gene frequency of DR7 decreased; the gene frequencies of All and B13 in ALL patients were significantly higher than that in normal controls; the gene frequencies of A24, B58 and DR9 in ANLL patients were significantly higher than that in normal controls. It is concluded that HLA-A2, A11, B58 and DR9 are predisposing genes of CML patients, DR7 is an antagonistic gene, HLA-A11 and B13 are predisposing genes of ALL patients, HLA-A24, B58 and DR9 are predisposing genes of ANLL patients.