RESUMEN
BACKGROUND: The recent emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a rapid proliferation of serologic assays. However, little is known about their clinical performance. Here, we compared two commercial SARS-CoV-2 IgG assays. METHODS: 103 specimens from 48 patients with PCR-confirmed SARS-CoV-2 infections and 153 control specimens were analyzed using SARS-CoV-2 serologic assays by Abbott and EUROIMMUN (EI). Duration from symptom onset was determined by medical record review. Diagnostic sensitivity, specificity, and concordance were calculated. RESULTS: The Abbott SARS-CoV-2 assay had a diagnostic specificity of 99.4% (95% CI; 96.41-99.98%), and sensitivity of 0.0% (95% CI; 0.00-26.47%) at <3 days post symptom onset, 30.0% (95% CI; 11.89-54.28) at 3-7d, 47.8% (95% CI; 26.82-69.41) at 8-13d and 93.8% (95% CI; 82.80-98.69) at ≥14d. Diagnostic specificity on the EI assay was 94.8% (95% CI; 89.96-97.72) if borderline results were considered positive and 96.7% (95% CI; 92.54-98.93) if borderline results were considered negative. The diagnostic sensitivity was 0.0% (95% CI; 0.00-26.47%) at <3d, 25.0% (95% CI; 8.66-49.10) at 3-7d, 56.5% (95% CI; 34.49-76.81) at 3-7d and 85.4% (95% CI; 72.24-93.93) at ≥14d if borderline results were considered positive. The qualitative concordance between the assays was 0.83 (95% CI; 0.75-0.91). CONCLUSION: The Abbott SARS-CoV-2 assay had fewer false positive and false negative results than the EI assay. However, diagnostic sensitivity was poor in both assays during the first 14 days of symptoms.
Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Anticuerpos Antivirales/inmunología , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/virología , Reacciones Falso Positivas , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoglobulina G/análisis , Inmunoglobulina G/inmunología , Pandemias , Neumonía Viral/virología , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , SARS-CoV-2 , Sensibilidad y Especificidad , Factores de TiempoAsunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/virología , Reacciones Falso Positivas , Humanos , Inmunoensayo , Pandemias , Neumonía Viral/virología , Juego de Reactivos para Diagnóstico , SARS-CoV-2 , Factores de TiempoRESUMEN
BACKGROUND: Serum free light chain (FLC) assays are used clinically to measure the concentration of κ and λ FLC in patients with suspected or diagnosed plasma cell proliferative disorders. Previous studies have demonstrated a loss of linearity in low concentration ranges of these assays. We hypothesized that this result could be caused by a matrix effect. METHODS: Recovery studies were performed for κ and λ FLC in both serum and saline using the Freelite assay (Binding Site) on a Cobas c502 system (Roche). Samples were analyzed either at the recommended dilution or undiluted. Follow-up studies were performed in varying matrices ranging from 0% to 100% saline. Retrospective patient data were analyzed to assess the impact on reported κ FLC, λ FLC, and κ/λ ratio. RESULTS: FLC in a serum matrix demonstrated underrecovery relative to samples diluted in saline for both κ and λ FLC. Of 255 patient samples with λ FLC measured undiluted (λ FLC <6.0 mg/L), an unexpected gap was observed in patient results between 2.0 and 6.0 mg/L. In addition, 23 patients measured serially with λ FLC between 2.0 and 6.0 mg/L demonstrated dramatic changes in κ/λ ratio, with no changes in κ FLC, likely because of the matrix effect. CONCLUSIONS: The κ and λ Freelite assays exhibit a matrix effect when samples are tested undiluted, which has the potential to affect the κ/λ ratio. Consequently, our laboratory has stopped reporting λ FLC <6.0 mg/L.
Asunto(s)
Bioensayo/métodos , Bioensayo/normas , Cadenas Ligeras de Inmunoglobulina/sangre , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Reproducibilidad de los Resultados , Estudios RetrospectivosRESUMEN
Mice with heterozygous deletion of the PTEN tumor suppressor gene develop a range of epithelial neoplasia as well as lymphoid hyperplasia. Previous studies suggest that PTEN suppresses tumor formation by acting as a phosphoinositide phosphatase to limit signaling by phosphoinositide 3-kinase (PI3K). Here, we examined the effect of deleting various regulatory subunits of PI3K (p85alpha and p85beta) on epithelial neoplasia and lymphoid hyperplasia in PTEN+/- mice. Interestingly, we found the loss of one p85alpha allele with or without the loss of p85beta led to increased incidence of intestinal polyps. Signaling downstream of PI3K was enhanced in the PTEN+/-p85alpha+/-p85beta-/- polyps, as judged by an increased fraction of both cells with cytoplasmic staining of the transcription factor FKHR and cells with positive staining for the proliferation marker Ki-67. In contrast, the incidence of prostate intraepithelial neoplasia was not significantly altered in PTEN+/- mice heterozygous for p85alpha or null for p85beta, whereas the fraction of proliferating cells in prostate intraepithelial neoplasia was reduced in mice lacking p85beta. Finally, there was no significant change in T lymphocyte hyperplasia in the PTEN+/- mice with various p85 deletions, although anti-CD3-stimulated AKT activation was somewhat reduced in the p85alpha+/- background. These results indicate that decreasing the levels of different p85 regulatory subunits can result in enhanced PI3K signaling in some tissues and decreased PI3K signaling in others, supporting the model that, although p85 proteins are essential for class I(A) PI3K signaling, they can function as inhibitors of PI3K signaling in some tissues and thus suppress tumor formation.