Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880779

RESUMEN

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.

2.
Clin Chem Lab Med ; 61(7): 1255-1265, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36753693

RESUMEN

OBJECTIVES: The therapeutic antibody infliximab (IFX) has improved the life quality of numerous autoinflammatory disease patients. However, IFX can trigger the generation of anti-drug antibodies (ADA), whose optimal evaluation and management are currently subject of controversial discussions. We present two novel surface plasmon resonance (SPR) biosensor assays for therapeutic drug monitoring of IFX and characterization of ADA and investigated the diagnostic value of ADA binding properties. METHODS: IFX and ADA were quantified via developed SPR biosensor assays (IFXmon and ADAmon, respectively) and diagnostics-approved ELISA in sera from inflammatory bowel disease patients. Pre-analytic ADA enrichment with magnetic beads enabled analytical drug tolerance of the ADAmon assay. The dissociation ratio (DissR) as an index for ADA:IFX binding stability was calculated from the SPR sensorgrams of ADA quantification runs. RESULTS: IFX levels determined by IFXmon assay and ELISA showed high agreement, whereas ADA quantification concordance between ADAmon assay and ELISA was poor. In patients, DissR was predominantly constant over time and differed significantly between therapy outcomes. A DissR cut-off of 1.524 indicated undetectable IFX levels with 71.4% sensitivity and 88.9% specificity. Additionally, the SPR reference surface was exploited as serum-individual negative control to check result plausibility within multi-sample run sequences. CONCLUSIONS: Overall, both SPR biosensor assays exhibited reliable quantitative performance with accuracies superior to their ELISA counterparts and precision inferior to ELISA only for ADAmon. DissR presented itself as promising ADA binding parameter and could contribute to both earlier and more tailored therapeutic decisions.


Asunto(s)
Monitoreo de Drogas , Resonancia por Plasmón de Superficie , Humanos , Infliximab , Relevancia Clínica , Anticuerpos , Ensayo de Inmunoadsorción Enzimática
3.
Anal Bioanal Chem ; 414(10): 3243-3255, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34936009

RESUMEN

The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported.


Asunto(s)
Inmunosupresores , Dispositivos Ópticos , Humanos , Inmunoensayo , Microfluídica , Silicio
4.
Clin Chem Lab Med ; 59(5): 935-945, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33554521

RESUMEN

OBJECTIVES: Therapeutic drug monitoring (TDM) plays a crucial role in personalized medicine. It helps clinicians to tailor drug dosage for optimized therapy through understanding the underlying complex pharmacokinetics and pharmacodynamics. Conventional, non-continuous TDM fails to provide real-time information, which is particularly important for the initial phase of immunosuppressant therapy, e.g., with cyclosporine (CsA) and mycophenolic acid (MPA). METHODS: We analyzed the time course over 8 h of total and free of immunosuppressive drug (CsA and MPA) concentrations measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 16 kidney transplant patients. Besides repeated blood sampling, intravenous microdialysis was used for continuous sampling. Free drug concentrations were determined from ultracentrifuged EDTA-plasma (UC) and compared with the drug concentrations in the respective microdialysate (µD). µDs were additionally analyzed for free CsA using a novel immunosensor chip integrated into a fluorescence detection platform. The potential of microdialysis coupled with an optical immunosensor for the TDM of immunosuppressants was assessed. RESULTS: Using LC-MS/MS, the free concentrations of CsA (fCsA) and MPA (fMPA) were detectable and the time courses of total and free CsA comparable. fCsA and fMPA and area-under-the-curves (AUCs) in µDs correlated well with those determined in UCs (r≥0.79 and r≥0.88, respectively). Moreover, fCsA in µDs measured with the immunosensor correlated clearly with those determined by LC-MS/MS (r=0.82). CONCLUSIONS: The new microdialysis-supported immunosensor allows real-time analysis of immunosuppressants and tailor-made dosing according to the AUC concept. It readily lends itself to future applications as minimally invasive and continuous near-patient TDM.


Asunto(s)
Técnicas Biosensibles , Inmunosupresores , Cromatografía Liquida , Monitoreo de Drogas , Humanos , Inmunoensayo , Ácido Micofenólico , Preparaciones Farmacéuticas , Espectrometría de Masas en Tándem
5.
Platelets ; 32(3): 398-403, 2021 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-32316806

RESUMEN

The extent of the involvement of platelets in venous thromboembolisms (VTE) is still not fully understood. Immature platelets are large, RNA-rich, prothrombotic platelets. They are involved in arterial thromboembolisms and are associated with adverse cardiovascular events. Their role in VTE has not been investigated before. The aim of this study was to assess different platelet parameters including immature platelet fraction (IPF), immature platelet count (IPC), absolute platelet count and platelet aggregation (PA) over time in patients with VTE at time of diagnosis, as well as at 3-10 days and at 90-110 days after diagnosis. 50 healthy volunteers similar in age and sex to patients served as controls at diagnosis. IPF was measured by the Sysmex XE-5000 analyzer, PA was assessed using the Multiplate analyzer. Diagnosis of VTE had no relevant effect on IPF and IPC whereas absolute platelet count and PA were significantly decreased compared to controls. In the course of VTE, IPF decreased significantly, whereas IPC, absolute platelet count and PA increased. In conclusion, VTE was associated with relevant changes of the absolute platelet count and PA at diagnosis, as well as changes in IPF and IPC over time reflecting a relevant and measurable platelet consumption in VTEs.


Asunto(s)
Plaquetas/metabolismo , Recuento de Plaquetas/métodos , Tromboembolia Venosa/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agregación Plaquetaria
6.
PLoS Pathog ; 14(5): e1007048, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29718991

RESUMEN

The exceptional toxicity of botulinum neurotoxins (BoNTs) is mediated by high avidity binding to complex polysialogangliosides and intraluminal segments of synaptic vesicle proteins embedded in the presynaptic membrane. One peculiarity is an exposed hydrophobic loop in the toxin's cell binding domain HC, which is located between the ganglioside- and protein receptor-binding sites, and that is particularly pronounced in the serotypes BoNT/B, DC, and G sharing synaptotagmin as protein receptor. Here, we provide evidence that this HC loop is a critical component of their tripartite receptor recognition complex. Binding to nanodisc-embedded receptors and toxicity were virtually abolished in BoNT mutants lacking residues at the tip of the HC loop. Surface plasmon resonance experiments revealed that only insertion of the HC loop into the lipid-bilayer compensates for the entropic penalty inflicted by the dual-receptor binding. Our results represent a new paradigm of how BoNT/B, DC, and G employ ternary interactions with a protein, ganglioside, and lipids to mediate their extraordinary neurotoxicity.


Asunto(s)
Toxinas Botulínicas/genética , Toxinas Botulínicas/metabolismo , Animales , Sitios de Unión , Toxinas Botulínicas Tipo A/metabolismo , Proteínas Portadoras/metabolismo , Membrana Celular/metabolismo , Cristalografía por Rayos X , Gangliósidos , Interacciones Hidrofóbicas e Hidrofílicas , Lípidos , Glicoproteínas de Membrana/metabolismo , Ratones , Unión Proteica , Conformación Proteica , Receptores de Neurotransmisores/metabolismo , Serogrupo , Vesículas Sinápticas
7.
Clin Lab ; 66(1)2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32013370

RESUMEN

BACKGROUND: Point-of-care tests (POCT) measure analytes close to the patients and are a complementary supplement to the test menu of medical laboratories. However, the involvement of many different stakeholders makes it challenging to ensure reliable results. METHODS: In a survey, we asked experienced POCT users how they control their total POCT process and what factors they consider essential for success. Results were verified in four in-depth interviews. RESULTS: Overall, 73 German participants from various medical disciplines completed the survey. All but one participant regarded operator training as important but only half of the participants' institutions conducted operator training on a regular basis. Participants often requested e-learning, but face-to-face teaching is still preferred. Twenty-one percent of participants already used e-learning and reported mixed satisfaction. Fifty-five percent of the participants never refer to the quality management manual. Instead, 94% stated that if a POCT error arises a contact person for POCT is always available at their workplace. The majority of participants think that external and, in particular, internal quality controls are important for POCT. Only a few difficulties for performing quality control such as "temporal expenditure" and "lack of information about the importance of internal quality control" were commonly mentioned. For future developments, participants expect evolution and improvements especially with regard to "measurement quality and reliability". The answers of the experts in the in-depth interviews largely corresponded with the participants of the survey. CONCLUSIONS: The importance of operator training is well established and confirmed in this work. How to conduct this training is less certain, but the answers in this survey suggest some form of blended learning with e-learning and practical elements. The discrepancy between the high importance that guidelines and other normative documents place on written information and their low practical usage was striking.


Asunto(s)
Personal de Salud/educación , Sistemas de Atención de Punto/normas , Pruebas en el Punto de Atención/normas , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Garantía de la Calidad de Atención de Salud , Control de Calidad , Adulto Joven
8.
Anal Bioanal Chem ; 411(29): 7623-7635, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31236649

RESUMEN

Immunodiagnostic tests performed at the point of care (POC) today usually employ antibodies for biorecognition and are read out either visually or with specialized equipment. Availability of alternative biorecognition elements with promising features as well as smartphone-based approaches for signal readout, however, challenge the described established configuration in terms of analytical performance and practicability. Assessing these developments' clinical relevance and their impact on POC immunodiagnostics is demanding. The first part of this review will therefore give an overview on suitable diagnostic biosensors based on alternative recognition elements (such as nucleic acid-based aptamers or engineered binding proteins) and exemplify advantages and drawbacks of these biomolecules on the base of selected assays. The second part of the review then focuses on smartphone-connected diagnostics and discusses the indispensable considerations required for successful future clinical POCT implementation. Together, the joint depiction of two of the most innovative and exciting developments in the field will enable the reader to cast a glance into the distant future of POC immunodiagnostics.


Asunto(s)
Pruebas Inmunológicas/métodos , Teléfono Inteligente , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/instrumentación , Humanos , Pruebas Inmunológicas/normas , Sistemas de Atención de Punto , Sensibilidad y Especificidad
9.
Anal Bioanal Chem ; 411(29): 7607-7621, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31152226

RESUMEN

Immunological methods are widely applied in medical diagnostics for the detection and quantification of a plethora of analytes. Associated analytical challenges usually require these assays to be performed in a central laboratory. During the last several years, however, the clinical demand for rapid immunodiagnostics to be performed in the immediate proximity of the patient has been constantly increasing. Biosensors constitute one of the key technologies enabling the necessary, yet challenging transition of immunodiagnostic tests from the central laboratory to the point of care. This review is intended to provide insights into the current state of this transition process with a focus on the role of biosensor-based systems. To begin with, an overview on standard immunodiagnostic tests presently employed in the central laboratory and at the point of care is given. The review then moves on to demonstrate how biosensor technologies are reshaping this landscape. Single analyte as well as multiplexed immunosensors applicable to point of care scenarios are presented. A section on the areas of clinical application then creates the bridge to day-to-day diagnostic practice. Finally, the depicted developments are critically weighed and future perspectives discussed in order to give the reader a firm idea on the forthcoming trends to be expected in this diagnostic field.


Asunto(s)
Técnicas Biosensibles/instrumentación , Pruebas Inmunológicas/métodos , Laboratorios/organización & administración , Sistemas de Atención de Punto/tendencias , Humanos
10.
Kidney Int ; 93(1): 221-230, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28941940

RESUMEN

Chronic inflammation contributes to increased mortality in hemodialysis (HD) patients. YKL-40 is a novel marker of inflammation, tissue remodeling, and highly expressed in macrophages inside vascular lesions. Elevated levels of YKL-40 have been reported for HD patients but how it integrates into the proinflammatory mediator network as a predictor of mortality remains elusive. We studied serum YKL-40, Interleukin-6 (IL-6), high-sensitivity C-reactive protein, monocyte chemotactic protein-1 (MCP-1), and interferon-gamma induced protein-10 (IP-10) in 475 chronic hemodialysis patients. Patients were followed for mortality for a median of 37 [interquartile range: 25-49] months and checked for interrelation of the measured mediators. To plot cumulative incidence functions, patients were stratified into terciles per YKL-40, IL-6, MCP-1, and IP-10 levels. Multivariable Cox regression models were built to examine associations of YKL-40, IP-10, and MCP-1 with all-cause and cause-specific mortality. Net reclassification improvement was calculated for the final models containing YKL-40 and IL-6. Increased YKL-40 was independently associated with age, IP-10, and IL-6 serum levels. After adjustment for demographic and laboratory parameters, comorbidities, and IL-6, only YKL-40 significantly improved risk prediction for all-cause (hazard ratio 1.4; 95% confidence interval 1.1-1.8) and cardiovascular mortality (hazard ratio 1.5; 95% confidence interval 1.03-2.2). Thus, in contrast to other biomarkers of aberrant macrophage activation, YKL-40 reflects inflammatory activity, which is not covered by IL-6. Mechanistic and prospective studies are needed to test for causal involvement of YKL-40 and whether it might qualify as a therapeutic target.


Asunto(s)
Proteína 1 Similar a Quitinasa-3/sangre , Mediadores de Inflamación/sangre , Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/terapia , Diálisis Renal/mortalidad , Anciano , Biomarcadores/sangre , Estudios Transversales , Femenino , Humanos , Fallo Renal Crónico/sangre , Fallo Renal Crónico/diagnóstico , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Clin Chem Lab Med ; 56(8): 1238-1250, 2018 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-29708877

RESUMEN

BACKGROUND: Determination of blood glucose concentration is one of the most important measurements in clinical chemistry worldwide. Analyzers in central laboratories (CL) and point-of-care tests (POCT) are both frequently used. In Germany, regular participation in external quality assessment (EQA) schemes is mandatory for laboratories performing glucose testing. METHODS: Glucose testing data from the two German EQAs "Reference Institute for Bioanalytics" (RfB) and "INSTAND - Gesellschaft zur Förderung der Qualitätssicherung in medizinischen Laboratorien" (Instand) were analyzed from 2012 to 2016. Multivariable odds ratios (OR) for the probability to reach a "good" result were calculated. Imprecision and bias were determined and clinical risk of measurement errors estimated. RESULTS: The device employed was the most important variable required for a "good" performance in all EQAs. Additional participation in an EQA for CL automated analyzers improved performance in POCT EQAs. The reciprocal effect was less pronounced. New participants performed worse than experienced participants especially in CL EQAs. Imprecision was generally smaller for CL, but some POCT devices reached a comparable performance. Large lot-to-lot differences occurred in over 10% of analyzed cases. We propose the "bias budget" as a new metric to express the maximum allowable bias that still carries acceptable medical risk. Bias budgets were smallest and clinical risks of errors greatest in the low range of measurement 60-115 mg/dL (3.3-6.4 mmol/L) for most devices. CONCLUSIONS: EQAs help to maintain high analytical performances. They generate important data that serve as the foundation for learning and improvement in the laboratory healthcare system.


Asunto(s)
Análisis Químico de la Sangre/normas , Glucemia/análisis , Control de Calidad , Sesgo , Análisis Químico de la Sangre/instrumentación , Alemania , Humanos , Pruebas en el Punto de Atención/normas
12.
Biochem J ; 474(8): 1361-1371, 2017 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-28246334

RESUMEN

Analysis of membrane proteins is still inadequately represented in diagnostics despite their importance as drug targets and biomarkers. One main reason is the difficult handling caused by their insolubility in aqueous buffer solutions. The nanodisc technology was developed to circumvent this challenge and enables analysis of membrane proteins with standard research methods. However, existing nanodisc generation protocols rely on time-consuming membrane isolation and protein purification from overexpression systems. In the present study, we present a novel, simplified procedure for the rapid generation of nanodiscs directly from intact cells. Workflow and duration of the nanodisc preparation were shortened without reducing the reconstitution efficiency, and all the steps were modified for the use of only standard laboratory equipment. This protocol was successfully applied to various human cell types, such as cultivated human embryonic kidney 293 (HEK-293) cells, as well as freshly isolated human red blood cells and platelets. In addition, the reconstitution of membrane proteins from cell organelles was achieved. The use of endogenous lipids ensures a native-like environment, which promotes native protein (re)folding. Nanodisc generation was verified by size exclusion chromatography and EM, whereas incorporation of different membrane proteins was demonstrated by Western blot analysis. Our protocol enabled the rapid incorporation of endogenous membrane proteins from human cells into nanodiscs, which can be applied to analytical approaches.


Asunto(s)
Plaquetas/metabolismo , Eritrocitos/metabolismo , Riñón/metabolismo , Membrana Dobles de Lípidos/metabolismo , Microdominios de Membrana/metabolismo , Proteínas de la Membrana/metabolismo , Modelos Moleculares , Plaquetas/ultraestructura , Cromatografía en Gel , Eritrocitos/ultraestructura , Células HEK293 , Humanos , Riñón/ultraestructura , Membrana Dobles de Lípidos/química , Lípidos de la Membrana/química , Lípidos de la Membrana/metabolismo , Microdominios de Membrana/ultraestructura , Proteínas de la Membrana/química , Proteínas de la Membrana/genética , Microscopía Electrónica de Transmisión , Nanoestructuras/química , Nanoestructuras/ultraestructura , Orgánulos/metabolismo , Orgánulos/ultraestructura , Fosfolípidos/química , Fosfolípidos/metabolismo , Pliegue de Proteína , Replegamiento Proteico
13.
Clin Chem ; 63(8): 1377-1387, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28615228

RESUMEN

BACKGROUND: In clinical chemistry, quality control (QC) often relies on measurements of control samples, but limitations, such as a lack of commutability, compromise the ability of such measurements to detect out-of-control situations. Medians of patient results have also been used for QC purposes, but it may be difficult to distinguish changes observed in the patient population from analytical errors. This study aims to combine traditional control measurements and patient medians for facilitating detection of biases. METHODS: The software package "rSimLab" was developed to simulate measurements of 5 analytes. Internal QC measurements and patient medians were assessed for detecting impermissible biases. Various control rules combined these parameters. A Westgard-like algorithm was evaluated and new rules that aggregate Z-values of QC parameters were proposed. RESULTS: Mathematical approximations estimated the required sample size for calculating meaningful patient medians. The appropriate number was highly dependent on the ratio of the spread of sample values to their center. Instead of applying a threshold to each QC parameter separately like the Westgard algorithm, the proposed aggregation of Z-values averaged these parameters. This behavior was found beneficial, as a bias could affect QC parameters unequally, resulting in differences between their Z-transformed values. In our simulations, control rules tended to outperform the simple QC parameters they combined. The inclusion of patient medians substantially improved bias detection for some analytes. CONCLUSIONS: Patient result medians can supplement traditional QC, and aggregations of Z-values are novel and beneficial tools for QC strategies to detect biases.


Asunto(s)
Algoritmos , Control de Calidad , Sesgo , Química Clínica , Humanos , Laboratorios , Programas Informáticos
14.
BJU Int ; 119(1): 30-37, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27037533

RESUMEN

OBJECTIVE: To determine the impact of elevated neuroendocrine serum markers on treatment outcome in patients with metastatic castration-resistant prostate cancer (mCRPC) undergoing treatment with abiraterone in a post-chemotherapy setting. PATIENTS AND METHOD: Chromogranin A (CGa) and neurone-specific enolase (NSE) were determined in serum drawn before treatment with abiraterone from 45 patients with mCRPC. Outcome measures were overall survival (OS), prostate-specific antigen (PSA) response defined by a PSA level decline of ≥50%, PSA progression-free survival (PSA-PFS), and clinical or radiographic PFS. RESULTS: The CGa and NSE serum levels did not correlate (P = 0.6). Patients were stratified in to low- (nine patients), intermediate- (18) or high-risk (18) groups according to elevation of none, one, or both neuroendocrine markers, respectively. The risk groups correlated with decreasing median OS (median OS not reached vs 15.3 vs 6.6 months; P < 0.001), decreasing median clinical or radiographic PFS (8.3 vs 4.4 vs 2.7 months; P = 0.001) and decreasing median PSA-PFS (12.0 vs 3.2 vs 2.7 months; P = 0.012). In multivariate Cox regression analysis the combination of CGa and NSE (≥1 marker positive vs both markers negative) remained significant predictors of OS, clinical or radiographic PFS, and PSA-PFS. We did not observe a correlation with PSA response (63% vs 35% vs 31%; P = 0.2). CONCLUSION: Chromogranin A and NSE did not predict PSA response in patients with mCRPC treated with abiraterone. However, we observed a correlation with shorter PSA-PFS, clinical or radiographic PFS, and OS. This might be due to an elevated risk of developing resistance under abiraterone treatment related to neuroendocrine differentiation.


Asunto(s)
Androstenos/uso terapéutico , Cromogranina A/sangre , Fosfopiruvato Hidratasa/sangre , Neoplasias de la Próstata Resistentes a la Castración/sangre , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Humanos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Valor Predictivo de las Pruebas , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata Resistentes a la Castración/patología , Estudios Retrospectivos , Resultado del Tratamiento
15.
Ther Drug Monit ; 39(3): 211-219, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28328764

RESUMEN

BACKGROUND: Therapeutic drug monitoring (TDM) of immunosuppressants is essential to optimize patient care after organ transplantation. In blood, most immunosuppressive drugs are bound to plasma proteins or located inside blood cells. However, it is generally assumed that only protein-unbound (free) drug concentrations are pharmacologically active and could therefore better reflect the clinical outcome. Study data are still limited due to lacking rapid analytical methods. Therefore, a simple multiplex method for direct measurement of free cyclosporine A (CsA) and mycophenolic acid (MPA) has been developed. METHODS: The sample preparation included ultracentrifugation, followed by liquid-liquid extraction. Stable isotope labeled analogues of CsA and MPA were used as internal standards. The LC-MS/MS analysis was performed on a triple quadrupole mass spectrometer in the multiple reaction monitoring mode. The validated assay was used in a study of 40 blood samples from kidney transplant patients. RESULTS: The lower limits of quantification were 0.1 (CsA) and 0.5 ng/mL (MPA). Assay linearity was confirmed in the concentration ranges of 0.1-10.0 ng/mL (CsA) and 0.5-100 ng/mL (MPA). For both analytes, inaccuracy was ≤9.8% and imprecision was ≤7.8%. The extraction efficiency ranged between 91% and 96%. In the patient samples the average free CsA and MPA fractions were 5.8% (2.1%-16.8%) and 1.2% (0.5%-2.4%) respectively. CONCLUSIONS: A reliable and highly sensitive LC-MS/MS method as a new suitable tool for measuring protein-unbound CsA and MPA has been developed, validated and applied in kidney transplant patient samples. Now, larger studies can be conducted to investigate the benefit of free drug monitoring in transplant recipients.


Asunto(s)
Ciclosporina/sangre , Ácido Micofenólico/sangre , Adulto , Anciano , Cromatografía Liquida/métodos , Monitoreo de Drogas/métodos , Femenino , Humanos , Inmunosupresores/sangre , Riñón/cirugía , Trasplante de Riñón/métodos , Extracción Líquido-Líquido/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Espectrometría de Masas en Tándem/métodos
17.
Clin Chem Lab Med ; 54(12): 1929-1937, 2016 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-27227709

RESUMEN

BACKGROUND: Method evaluation of new assays for the detection of antiphospholipid antibodies (aPL) such as anti-cardiolipin (aCL) or anti-ß2-glycoprotein I (aß2-GPI) is challenging, as no internationally accepted reference material is available yet. Besides a lack of standardization, unacceptable inter-laboratory comparability of established tests is regularly observed. Owing to the absence of a commonly accepted reference standard, the evaluation of two research surface plasmon resonance (SPR) biosensor assays was performed using statistical methods from latent class analysis (LCA). METHODS: aCL and aß2-GPI IgG and IgM were measured in sera from 63 antiphospholipid syndrome patients, fulfilling the Sydney criteria, and in 34 healthy controls with four commercial assays. LCA was performed on the results and sera were assigned to the antibody-positive or antibody-negative group. Sera were subsequently evaluated in the SPR assays for aCL and aß2-GPI. Optimal cutoffs and diagnostic performances of the research systems were established employing the LCA-derived gold standard. RESULTS: With area under the curve results of 0.96 and 0.89 for the detection of aCL and aß2-GPI, the research SPR assays discriminated well between antibody-positive and antibody-negative sera. Their sensitivities and specificities were comparable to the investigated commercial immunoassays. CONCLUSIONS: SPR assays are a suitable tool for the detection of aCL and aß2-GPI with diagnostic performances not different from currently available commercial tests. LCA enabled the calculation of sensitivities and specificities for aPL assays in absence of a reference standard.


Asunto(s)
Anticuerpos Antifosfolípidos/sangre , Modelos Estadísticos , Resonancia por Plasmón de Superficie/métodos , Adulto , Femenino , Humanos , Masculino , Estándares de Referencia , Resonancia por Plasmón de Superficie/normas
18.
Clin Chem Lab Med ; 54(1): 63-72, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26087066

RESUMEN

BACKGROUND: C-terminal agrin fragment (CAF), cleavage product of agrin, was previously correlated with kidney function in renal transplant patients. This article studies the predictive value of CAF for long-term outcomes in renal transplant recipients. METHODS: In this observational cohort study, serum CAF, creatinine and blood-urea-nitrogen (BUN) concentrations and eGFR (CKD-EPI) were assessed 1-3 months after transplantation in 105 patients undergoing kidney transplantation. Cox regression models were used to analyse the predictive value of all parameters concerning all-cause mortality (ACM), graft loss (GL), doubling of creatinine/proteinuria at the end of follow-up. RESULTS: Median follow-up time was 3.1 years. The mean concentrations were 191.9±152.4 pM for CAF, 176±96.8 µmol/L for creatinine, 12.6±6.2 mmol/L for BUN and 44.9±21.2 mL/min for CKD-EPI formula, respectively. In univariate analysis CAF and BUN concentrations predicted ACM (CAF: HR=1.003, 1.1-fold risk, p=0.043; BUN: HR=1.037, 1.3-fold risk, p=0.006). Concerning GL, CAF (HR=1.006, 3.1-fold risk, p<0.001), creatinine (HR=2.396, 2.6-fold risk, p<0.001), BUN (HR=1.048, 1.7-fold risk, p=0.001) and eGFR (CKD-EPI) (HR=0.941, 0.45-fold risk reduction, p=0.006) showed a statistically significant association. CAF was the only parameter significantly associated with doubling of proteinuria (HR=1.005, 1.7-fold risk, p<0.001). In multiple regression analysis (CAF only) the association remained significant for GL and doubling of proteinuria but not ACM. CONCLUSIONS: Early postoperative serum CAF appears to be a useful tool for the assessment of long-term outcomes in renal transplant recipients. Most importantly it represents a promising predictor for the development of proteinuria.


Asunto(s)
Agrina/sangre , Rechazo de Injerto/sangre , Rechazo de Injerto/diagnóstico , Supervivencia de Injerto , Trasplante de Riñón , Fragmentos de Péptidos/sangre , Proteinuria/sangre , Proteinuria/diagnóstico , Nitrógeno de la Urea Sanguínea , Estudios de Cohortes , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Persona de Mediana Edad
19.
Clin Lab ; 62(10): 2025-2031, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28164512

RESUMEN

BACKGROUND: During the course of acute kidney injury (AKI) patients may require renal replacement therapy (RRT). The preferred therapeutic measure for such patients is continuous RRT (CRRT). Anticoagulation is required to prevent clotting of the extracorporeal circuit. The actual KDIGO guidelines recommend citrate as the first line anticoagulant. METHODS: Citrate dose infused into the extracorporeal circuit should achieve an extracorporeal calcium concentration of 0.2 - 0.3 mmol/L. Here, we evaluated two blood gas analysers for their ability of covering the calcium concentration range needed for CRRT (Radiometer ABL 835; Instrumentation Laboratory GEM 4000). Measurements of iCa from 0.2 to 3.0 mmol/L were performed in aqueous 0.9% NaCl solutions with and without human serum albumin (HAS) and also in patient samples. RESULTS: Using the GEM analyser, differences of measured results to target values were low throughout the whole concentration range. Using the ABL system, the difference increased with lower target values and exceeded up to 60% at 0.2 mmol/L. The results were reproduced in patient samples. CONCLUSIONS: Measuring Ca2+ concentrations could result in an overdosing or underdosing of citrate when using an analytical method which is different to the instrument used initially to achieve the recommended concentrations. If measurement of the new method results in lower Ca2+ concentration and, therefore, reduced anticoagulation by citrate infusion this could lead to more clotting events. Overestimation of the calcium concentration by the new method in the extracorporeal circuit would result in an increased citrate dose delivered to the patient, leading to in vivo hypocalcemia and a pronouncement of citrate induced acid base derangements. Therefore, to monitor Ca2+ concentrations in CRRT during citrate anticoagulation, specific target values for each individual instrument must be established.


Asunto(s)
Anticoagulantes/farmacología , Análisis de los Gases de la Sangre/instrumentación , Calcio/sangre , Citratos/farmacología , Diálisis Renal , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad
20.
Clin Chem Lab Med ; 53(5): 801-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25274952

RESUMEN

BACKGROUND: The parallelization of clinically relevant antigens in a microarray format is of growing importance due to the ability to measure multiple antigen-antibody interactions. With the development of a microarray for the detection of antiphospholipid antibodies we focussed on one important autoimmune disease that is still diagnostically challenging. Reasons are the heterogeneity of the autoantibodies and the unspecific clinical symptoms. METHODS: For the covalent immobilization of antigenic structures, glass transducers were coated with 11-aminoundecyltrimethoxysilane (11-AUTMS). In total 35 antiphospholipid syndrome (APS) patients, six patients with lupus erythematosus and 24 healthy controls were investigated on a microarray format using polarized imaging reflectometric interference spectroscopy. RESULTS: The novel surface modification based on the short derivative 11-AUTMS resulted in a selective biosensor allowing a clear differentiation of patient and control samples. It combined proteinogenic as well as phospholipid-derived antigens, namely ß2-glycoprotein I (ß2-GPI), prothrombin, cardiolipin (CL) and a ß2-GPI/CL complex. With optimized regeneration conditions, up to 20 consecutive measurements could be performed on one chip. Sensitivity was determined to be 0.800-0.929, specificity was between 0.733 and 0.969, depending on the respective antigen. CONCLUSIONS: Multiplexed determination of serological parameters has a great potential. We have shown that our biosensor is capable of detecting four different APS relevant antibodies in parallel exhibiting a sensitivity and specificity comparable to existing ELISA methods.


Asunto(s)
Anticuerpos Antifosfolípidos/análisis , Antígenos/inmunología , Síndrome Antifosfolípido/diagnóstico , Análisis por Micromatrices/métodos , Anticuerpos Antifosfolípidos/inmunología , Antígenos/química , Vidrio/química , Humanos , Proteínas Inmovilizadas/química , Proteínas Inmovilizadas/inmunología , beta 2 Glicoproteína I/química , beta 2 Glicoproteína I/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA