Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Anaesthesia ; 71(6): 669-74, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26843146

RESUMEN

This observational study was designed to investigate the anatomical changes of the lumbar spine over the course of pregnancy using serial ultrasound scans. We performed paramedian scans on 58 women at the L2-3, L3-4 and L4-5 levels; these were done at four periods of 11+0-13+6, 19+0-23+0, 28+0-32+0 and 38+0-40+0 weeks gestation. At each intervertebral level, the length of the interlaminar space, length of the visible intervertebral posterior dura and depth of the posterior dura mater from the skin were measured. The length of the interlaminar space and length of the visible intervertebral posterior dura mater were longer, and the depth of the posterior dura mater was shallower, with ascending spinal interspace. The depth of the posterior dura mater increased during pregnancy, although it plateaued between the third and fourth measurement periods. The other spinal measurements were not affected by gestation. These findings indicate that the L2-3 level is the most appropriate puncture site for epidural anaesthesia in pregnant women. Our results ought to be embraced as a departure point towards developing neuraxial insertion techniques guided or aided by ultrasound.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/patología , Ultrasonografía , Adulto , Anestesia Epidural/métodos , Anestesia Obstétrica/métodos , Femenino , Humanos , Estudios Longitudinales , Embarazo
2.
Unfallchirurg ; 113(3): 195-202, 2010 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-19629421

RESUMEN

BACKGROUND: Locked plate devices offer advantages in the treatment of periprosthetic femur fractures associated with fixed total hip or total knee arthroplasty. The purpose of this study was to evaluate the early results and complications with a locked plate system (NCB-DF(R)). PATIENTS AND METHODS: A total of 31 patients (mean age 76 years, 7 males, 24 females) with a femur fracture above a fixed total knee arthroplasty (TKA, n=12) or a total hip arthroplasty (THA, n=19) were treated with a locked plate. RESULTS: There were 11 complications necessitating revision: 6 implant failures, 2 in patients with a THA and 4 in patients with a TKA, 4 hematomas and 1 infection and 2 patients died. After 6 months all fractures had healed securely but a secondary correction was necessary in one patient. CONCLUSION: Fixation of periprosthetic femur fractures with a locked plate system provided satisfactory results in patients with a THA, however, the relatively high implant failure rate in fractures above a stable TKA is a cause for concern.


Asunto(s)
Placas Óseas/efectos adversos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Prótesis de Cadera/efectos adversos , Prótesis de la Rodilla/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA