Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(7): 1360-1367, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38715310

RESUMEN

INTRODUCTION: Numerous P-wave indices have been explored as biomarkers to assess atrial fibrillation (AF) risk and the impact of therapy with variable success. OBJECTIVE: We investigated the utility of P-wave alternans (PWA) to track the effects of pulmonary vein isolation (PVI) and to predict atrial arrhythmia recurrence. METHODS: This medical records study included patients who underwent PVI for AF ablation at our institution, along with 20 control subjects without AF or overt cardiovascular disease. PWA was assessed using novel artificial intelligence-enabled modified moving average (AI-MMA) algorithms. PWA was monitored from the 12-lead ECG at ~1 h before and ~16 h after PVI (n = 45) and at the 4- to 17-week clinically indicated follow-up visit (n = 30). The arrhythmia follow-up period was 955 ± 112 days. RESULTS: PVI acutely reduced PWA by 48%-63% (p < .05) to control ranges in leads II, III, aVF, the leads with the greatest sensitivity in monitoring PWA. Pre-ablation PWA was ~6 µV and decreased to ~3 µV following ablation. Patients who exhibited a rebound in PWA to pre-ablation levels at 4- to 17-week follow-up (p < .01) experienced recurrent atrial arrhythmias, whereas patients whose PWA remained reduced (p = .85) did not, resulting in a significant difference (p < .001) at follow-up. The AUC for PWA's prediction of first recurrence of atrial arrhythmia was 0.81 (p < .01) with 88% sensitivity and 82% specificity. Kaplan-Meier analysis estimated atrial arrhythmia-free survival (p < .01) with an adjusted hazard ratio of 3.4 (95% CI: 1.47-5.24, p < .02). CONCLUSION: A rebound in PWA to pre-ablation levels detected by AI-MMA in the 12-lead ECG at standard clinical follow-up predicts atrial arrhythmia recurrence.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Electrocardiografía , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Venas Pulmonares , Recurrencia , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Factores de Tiempo , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Estudios de Casos y Controles
2.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1255-1270, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819346

RESUMEN

BACKGROUND: The boundaries of critical isthmuses for re-entrant ventricular tachycardia (VT) are formed by wavefront discontinuities (fixed lines of block, slow propagation, and rotational propagation) seen during baseline rhythm. It is unknown whether wavefront discontinuities can be automatically identified and targeted for ablation using electroanatomic mapping systems. OBJECTIVES: The purpose of this study was to assess the electrophysiologic characteristics of automatically projected wavefront discontinuity lines (WADLs) and outcomes of an ablation strategy targeting WADLs in a mixed cohort of VT patients. METHODS: Late activation substrate maps were analyzed from 1 or more baseline rhythm wavefronts. WADLs were identified using the Carto Extended Early Meets Late module. Number, total length, and distance to critical VT sites were measured. VT recurrence and VT-free survival were followed. RESULTS: In total, 49 patients underwent 52 ablations with 71 unique substrate maps analyzed (18.8% epicardial; 62.0% right ventricular paced, 28.2% sinus rhythm, 9.9% left ventricular paced). A total of 28 VT critical sites were identified in 24 patients. WADLs were present in 49 of 71 (69.0%) maps. WADLs were present regardless of cardiomyopathy etiology, mapping wavefront, or surface. At a WADL threshold of 30%, 73.9% of critical VT sites were in close proximity (≤15 mm) to a WADL. VT-free survival was 62% at 1 year, with a competing risk model estimating a 1-year risk of VT recurrence of 23%. CONCLUSIONS: WADLs can be automatically projected in a majority of patients in a mixed cohort of cardiomyopathy etiology, mapped wavefronts, and myocardial surfaces mapped. Targeting WADLs results in low rate of VT recurrence at 1 year.


Asunto(s)
Ablación por Catéter , Cicatriz , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Cicatriz/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Recurrencia
3.
Heart Rhythm ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38718942

RESUMEN

BACKGROUND: Myocardial electrical heterogeneity is critical for normal cardiac electromechanical function, but abnormal or excessive electrical heterogeneity is proarrhythmic. The spatial ventricular gradient (SVG), a vectorcardiographic measure of electrical heterogeneity, has been associated with arrhythmic events during long-term follow-up, but its relationship with short-term inducibility of ventricular arrhythmias (VAs) is unclear. OBJECTIVE: This study was designed to determine associations between SVG and inducible VAs during electrophysiology study. METHODS: A retrospective study was conducted of adults without prior sustained VA, cardiac arrest, or implantable cardioverter-defibrillator who underwent ventricular stimulation for evaluation of syncope and nonsustained ventricular tachycardia or for risk stratification before primary prevention implantable cardioverter-defibrillator implantation. The 12-lead electrocardiograms were converted into vectorcardiograms, and SVG magnitude (SVGmag) and direction (azimuth and elevation) were calculated. Odds of inducible VA were regressed by logistic models. RESULTS: Of 143 patients (median age, 69 years; 80% male; median left ventricular ejection fraction [LVEF], 47%; 52% myocardial infarction), 34 (23.8%) had inducible VAs. Inducible patients had lower median LVEF (38% vs 50%; P < .0001), smaller SVGmag (29.5 vs 39.4 mV·ms; P = .0099), and smaller cosine SVG azimuth (cosSVGaz; 0.64 vs 0.89; P = .0007). When LVEF, SVGmag, and cosSVGaz were dichotomized at their medians, there was a 39-fold increase in adjusted odds (P = .002) between patients with all low LVEF, SVGmag, and cosSVGaz (65% inducible) compared with patients with all high LVEF, SVGmag, and cosSVGaz (4% [n = 1] inducible). After multivariable adjustment, SVGmag, cosSVGaz, and sex but not LVEF or other characteristics remained associated with inducible VAs. CONCLUSION: Assessment of electrical heterogeneity by SVG, which reflects abnormal electrophysiologic substrate, adds to LVEF and identifies patients at high and low risk of inducible VA at electrophysiology study.

4.
J Innov Card Rhythm Manag ; 15(7): 5930-5934, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39011464

RESUMEN

With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA