1.
Catheter Cardiovasc Interv ; 92(6): 1030-1039, 2018 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-29271575

RESUMEN

OBJECTIVES: To evaluate the safety and efficacy of the PRO-Kinetic Energy (PKE) Cobalt Chromium Coronary Stent System (BIOTRONIK AG, Switzerland). BACKGROUND: Percutaneous coronary intervention is a mainstay treatment for symptomatic coronary artery disease (CAD). While drug-eluting stents constitute a majority of implants, bare-metal stents (BMS) remain important for a subset of patients. Newer generation BMS offer advantages due to stent design improvements. METHODS: The BIOHELIX-I study was a prospective, multicenter, non-randomized, single arm clinical trial designed to evaluate the safety and efficacy of the PKE bare metal stent. Thirty-three study centers (US, Columbia, Europe) enrolled 329 patients for treatment of one target lesion (≤31 mm). Eligible patients received a PKE stent(s), at least one month of dual antiplatelet therapy and were followed for 36-months. The primary endpoint was the 9-month rate of target vessel failure (TVF) compared with a prespecified performance goal of 18.7% derived from prior BMS trials. RESULTS: The mean patient age was 69 years, 28.6% with diabetes. The mean lesion length was 13.7 ± 6.0 mm. The 9-month TVF rate was 9.06% and met the primary endpoint (P < 0.001). The TVF component rates were 0.95% cardiac death, 1.58% myocardial infarction, and 7.26% ischemia-driven target vessel revascularization (TVR). The ischemia-driven target lesion revascularization rate at 9-months was 6.62%. CONCLUSIONS: The 9-month TVF rate of the PKE stent was comparable to other BMS and is a viable option for treating CAD. The low observed rate of ischemia-driven TVR supports the safety and efficacy of the novel BMS design.


Asunto(s)
Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 88(7): 1046-1055, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26707858

RESUMEN

BACKGROUND: In the RadiCure study 505 catheterization procedures were 1:1 randomized to use or no use of real-time radiation monitoring. Use of the Bleeper Sv monitor resulted in a significant reduction in operator radiation exposure. METHODS: We examined the association between several baseline and procedural parameters with operator and patient radiation exposure using univariable and multivariable analysis in the 505 patients that were enrolled in RadiCure. All baseline demographic and procedure characteristics recorded were included in the univariable analysis. RESULTS: Median fluoroscopy time was 6.2 (2.5-12.5) minutes, median patient air kerma dose was 0.908 (0.602-1.636) Gray and median first operator exposure was 10 (5-22) µSv. For analysis purposes, the 505 procedures were dichotomized based on the median operator exposure (10 µSv) and median patient radiation dose (0.908 Gray). On multivariable analysis, factors associated with high (above median or >10 µSv) first operator radiation exposure included radial access (odds ratio [OR] 5.44, 95% Confidence Interval [CI] 2.88-10.76), chronic total occlusion (CTO) intervention (OR 12.78, 95% CI 4.42-43.60), real-time radiation monitoring (OR 0.42, 95% CI 0.26-0.66), and use of a radioabsorbent drape (OR 0.53, 95% CI 0.28-0.96). High patient radiation dose (above median or >0.908 Gray) was associated with body mass index>30 kg/m2 (OR 3.22, 95% CI 1.99-5.29), prior MI (OR 2.26, 95% CI 1.29-4.04), prior cerebrovascular disease (OR 0.34, 95% CI 0.15-0.75), hypertension (OR 2.40, 95% CI 1.05-5.82), prior coronary artery bypass graft surgery (OR 2.46, 95% CI 1.40-4.39) and CTO intervention (OR 12.93, 95% CI 3.28-87.31), but was not associated with real-time radiation monitoring and use of a radioabsorbent drape. CONCLUSIONS: Several clinical and procedural factors are associated with higher patient and operator radiation exposure. Real-time radiation monitoring and use of disposable radiation shields were associated with lower operator, but not patient, radiation dose. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Alarmas Clínicas , Exposición Profesional/prevención & control , Dosis de Radiación , Exposición a la Radiación/prevención & control , Monitoreo de Radiación/instrumentación , Protección Radiológica/instrumentación , Radiografía Intervencional/métodos , Anciano , Cateterismo Cardíaco/efectos adversos , Distribución de Chi-Cuadrado , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Exposición Profesional/efectos adversos , Salud Laboral , Oportunidad Relativa , Seguridad del Paciente , Equipo de Protección Personal , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Medición de Riesgo , Factores de Riesgo , Texas , Factores de Tiempo
3.
Catheter Cardiovasc Interv ; 85(3): 393-9, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-24407867

RESUMEN

BACKGROUND: The impact of operator experience on fluoroscopy time and contrast utilization during percutaneous coronary intervention (PCI) of coronary chronic total occlusions (CTOs) has received limited study. METHODS: We evaluated temporal trends in fluoroscopy time and contrast utilization among 1,363 consecutive CTO PCIs performed at three US institutions between January 2006 and November 2011. RESULTS: Mean age was 65 ± 11 years, 85% of patients were men, 40% had diabetes, 37% had prior coronary artery bypass graft surgery, and 42% had prior PCI. The CTO target vessel was the right coronary artery (55%), circumflex (23%), left anterior descending artery (21%), and left main or bypass graft (1%). The retrograde approach was used in 34% of all procedures. The technical and procedural success rates were 85.5 and 84.2%, respectively. The mean procedural time, fluoroscopy time, and contrast utilization were 113 ± 61 min, 42 ± 29 min, and 294 ± 158 mL, respectively. Years since initiation of CTO PCI were independently associated with higher technical success rate (odds ratio [OR] = 1.52, 95% confidence interval [CI] = 1.52-1.70, P < 0.001), lower fluoroscopy time (OR = 0.84, 95% CI = 0.75-0.95, P = 0.005), and contrast utilization (OR = 0.84, 95% CI = 0.62-0.79, P < 0.001) during the study period. CONCLUSIONS: Among selected US-based institutions performing CTO PCI, we observed a significant reduction in total fluoroscopy time and contrast utilization paralleled with an improved technical success rate over time.


Asunto(s)
Medios de Contraste , Angiografía Coronaria/tendencias , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea/tendencias , Pautas de la Práctica en Medicina/tendencias , Radiografía Intervencional/tendencias , Anciano , Distribución de Chi-Cuadrado , Competencia Clínica , Medios de Contraste/efectos adversos , Angiografía Coronaria/efectos adversos , Femenino , Fluoroscopía/tendencias , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Dosis de Radiación , Radiografía Intervencional/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
4.
Catheter Cardiovasc Interv ; 84(4): 670-5, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-24327476

RESUMEN

BACKGROUND: Aortocoronary dissection can complicate percutaneous coronary intervention (PCI) of chronic total occlusions (CTOs). METHODS: We retrospectively examined the frequency and outcomes of aortocoronary dissection among 336 consecutive CTO PCIs performed at our institution between 2005 and 2012 and performed a systematic review of the published literature. RESULTS: Aortocoronary dissection occurred in six patients (1.8%, 95% confidence intervals 0.7%, 3.8%). All aortocoronary dissections occurred in the right coronary artery (CTO target vessel in five patients and donor vessel in one patient). The baseline clinical characteristics of patients with and without aortocoronary dissection were similar. Compared to patients without, those with aortocoronary dissection were more likely to undergo crossing attempts using the retrograde approach (25% vs. 67%, P = 0.036) and experience a major complication (2.4% vs. 33.3%, P = 0.008). Technical and procedural success rates were similar in both groups. Of the six patients with aortocoronary dissection one underwent emergency coronary bypass graft surgery (CABG), four were treated with ostial stenting, and one was treated conservatively without subsequent adverse clinical outcomes. Systematic literature review provided 107 published cases of aortocoronary dissection during PCI, that occurred mainly in the right coronary artery (74.8%) and were treated with stenting (49.5%), emergency CABG (29%), or conservatively (21.5%). CONCLUSIONS: Aortocoronary dissection is an infrequent complication of CTO PCI and although it can be treated with stents in most patients, it may infrequently require emergency CABG.


Asunto(s)
Aorta , Puente de Arteria Coronaria , Oclusión Coronaria/terapia , Vasos Coronarios/cirugía , Lesiones Cardíacas/terapia , Intervención Coronaria Percutánea/efectos adversos , Lesiones del Sistema Vascular/terapia , Anciano , Aorta/lesiones , Enfermedad Crónica , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Oclusión Coronaria/diagnóstico , Vasos Coronarios/lesiones , Ecocardiografía Transesofágica , Femenino , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/etiología , Lesiones Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Stents , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/cirugía
5.
Catheter Cardiovasc Interv ; 84(5): 727-31, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-23804461

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) coronary imaging requires displacement of red blood cells from the vessel lumen. This is usually accomplished using radiographic contrast. Low molecular weight dextran has low cost and is safe in low volumes. In the present study, we compared dextran with contrast for coronary OCT imaging. METHODS: Fifty-one vessels in 26 patients were sequentially imaged using manual injection of radiographic contrast (iodixanol) and dextran. OCT images were analyzed at 1 mm intervals to determine the image clarity (defined as a visible lumen border > 270°) and to measure the lumen area and lumen diameter. To correct for the refractive index of dextran, the dextran area measurements were multiplied by 1.117 and the dextran length measurements were multiplied by 1.057. RESULTS: A total of 3,418 cross-sections (1,709 with contrast and 1,709 with dextran) were analyzed. There were no complications related to OCT imaging or to contrast or dextran administration. Clear image segments were observed in 97.0% vs. 96.7% of the cross-sections obtained with contrast and dextran, respectively (P = 0.45). The mean lumen areas were also similar: 6.69 ± 1.95 mm(2) with iodixanol vs. 7.06 ± 2.06 mm(2) with dextran (correlation coefficient 0.984). CONCLUSIONS: The image quality and measurements during OCT image acquisition are similar for dextran and contrast. Dextran could be used instead of contrast for OCT imaging, especially in patients in whom contrast load minimization is desired.


Asunto(s)
Medios de Contraste , Enfermedad de la Arteria Coronaria/diagnóstico , Dextranos , Tomografía de Coherencia Óptica/métodos , Ácidos Triyodobenzoicos , Anciano , Estudios de Cohortes , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Peso Molecular , Sensibilidad y Especificidad , Stents
6.
Catheter Cardiovasc Interv ; 84(4): 637-43, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-24142769

RESUMEN

OBJECTIVES: We sought to determine the contemporary prevalence and management of coronary chronic total occlusions (CTO) in a veteran population. BACKGROUND: The prevalence and management of CTOs in various populations has received limited study. METHODS: We collected clinical and angiographic data in consecutive patients that underwent coronary angiography at our institution between January 2011 and December 2012. Coronary artery disease (CAD) was defined as ≥50% diameter stenosis in ≥1 coronary artery. CTO was defined as total coronary artery occlusion of ≥3 month duration. RESULTS: Among 1,699 patients who underwent angiography during the study period, 20% did not have CAD, 20% had CAD and prior coronary artery bypass graft surgery (CABG), and 60% had CAD but no prior CABG. The prevalence of CTO among CAD patients with and without prior CABG was 89 and 31%, respectively. Compared to patients without CTO, CTO patients had more co-morbidities, more extensive CAD and were more frequently referred for CABG. Percutaneous coronary intervention (PCI) to any vessel was performed with similar frequency in patients with and without CTO (50% vs. 53%). CTO PCI was performed in 30% of patients without and 15% of patients with prior CABG with high technical (82 and 75%, respectively) and procedural success rates (80 and 73%, respectively). CONCLUSIONS: In a contemporary veteran population, coronary CTOs are highly prevalent and are associated with more extensive co-morbidities and higher likelihood for CABG referral. PCI was equally likely to be performed in patients with and without CTO.


Asunto(s)
Puente de Arteria Coronaria , Oclusión Coronaria/epidemiología , Oclusión Coronaria/terapia , Hospitales de Veteranos , Intervención Coronaria Percutánea , Centros de Atención Terciaria , United States Department of Veterans Affairs , Anciano , Enfermedad Crónica , Comorbilidad , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Derivación y Consulta , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
7.
J Interv Cardiol ; 27(2): 177-81, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24450393

RESUMEN

OBJECTIVES: To assess the impact of viscosity on angioplasty balloon deflation times. BACKGROUND: Lower contrast viscosity could result in more rapid coronary balloon deflation times. METHODS: We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. RESULTS: The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P < 0.001) and 39.0% (P < 0.001) reduction in mean balloon deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). CONCLUSIONS: Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Medios de Contraste , Cineangiografía , Ácido Yoxáglico , Factores de Tiempo , Ácidos Triyodobenzoicos , Viscosidad
8.
J Interv Cardiol ; 27(5): 465-71, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25158049

RESUMEN

OBJECTIVE: To compare long-term clinical outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using the retrograde and antegrade approach. BACKGROUND: There is limited long-term clinical outcomes data on the retrograde approach to CTO PCI. METHODS: We performed a retrospective analysis of the long-term clinical outcomes of 193 consecutive patients who underwent successful CTO PCI at our institution between March 2008 and December 2011. RESULTS: Mean age was 63.6 ± 8.3 years. The target vessel was right coronary artery in 52.6%, left anterior descending artery in 24.5% and circumflex in 21.4% of cases. The retrograde approach was used in 41 patients (21.2%). The mean stent length was longer in the retrograde group (83 ± 32 vs. 64 ± 32 mm, P = 0.001). Two major procedural complications occurred, both in the retrograde group (P = 0.012). During a median follow-up of 2.0 years compared to the antegrade CTO PCI group, patients who underwent retrograde CTO PCI were more likely to undergo target lesion revascularization (TLR) (45.6% vs. 25.7%, P = 0.006). No significant difference was observed in the incidence of all-cause mortality, myocardial infarction, non-target vessel revascularization, or coronary artery bypass graft surgery between the 2 groups. On multivariate analysis, stent length was the only independent predictor of TLR during follow-up. CONCLUSIONS: Retrograde CTO PCI was associated with higher incidence of TLR, but similar incidence of death and myocardial infarction compared to antegrade CTO PCI. These findings likely reflect the higher complexity of CTO lesions treated with the retrograde approach.


Asunto(s)
Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/estadística & datos numéricos , Evaluación del Resultado de la Atención al Paciente , Estudios Retrospectivos , Stents
9.
J Interv Cardiol ; 27(1): 36-43, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24456334

RESUMEN

OBJECTIVE: To assess the outcomes of the "hybrid" approach to chronic total occlusion (CTO) percutaneous coronary interventions (PCIs). BACKGROUND: The "hybrid approach" to CTO PCI advocates appropriate and early change of crossing strategy to maximize success, safety, and efficiency. METHODS: We prospectively recorded and analyzed detailed step-by-step procedural data in 73 consecutive CTO PCI cases performed by a single operator between July 2011 and August 2012. RESULTS: Technical success was achieved in 66 of 73 cases (90.4%). Mean patient age was 65 ± 7 years, and 30% had prior coronary artery bypass surgery. Dual injection was used in 78%. The primary approach was retrograde in 9 cases (12.5%) and antegrade in 64 cases (87.5%), of whom 25 cases (39.1%) underwent retrograde attempt after failed antegrade approach. The initial crossing approach was successful in 40 cases (54.8%), but 32 cases (44%) required 3.6 ± 1.4 approach changes (range 2-7). Antegrade wire escalation, antegrade dissection/reentry, and retrograde crossing were utilized in 97.2%, 46.6%, and 46.6% of cases, respectively. Among successful cases, the final CTO crossing technique was antegrade wire escalation in 50.0%, antegrade dissection/reentry in 24.2%, and retrograde in 25.8%. The mean procedure time, fluoroscopy time, and air kerma radiation exposure until CTO crossing or stopping the procedure were 66 ± 55 minutes, 25 ± 23 minutes, and 2.3 ± 1.9 Gray, respectively. Three patients (4.1%) had a major complication. CONCLUSION: In the "hybrid approach" to CTO PCI, changes in crossing strategy were needed in approximately half the cases, resulting in high success and low complication rates.


Asunto(s)
Intervención Coronaria Percutánea/métodos , Anciano , Angiografía Coronaria , Femenino , Humanos , Masculino , Estudios Prospectivos
10.
Catheter Cardiovasc Interv ; 80(7): 1157-62, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-22511587

RESUMEN

BACKGROUND: Stenting of large lipid core plaques (LCPs), as assessed by near-infrared spectroscopy (NIRS), has been associated with periprocedural myocardial infarction (MI), possibly due to distal embolization. METHODS: An embolic protection device (EPD) was inserted before stenting in nine native coronary arteries with large LCP, as assessed by NIRS. Embolized material was assessed by histopathology. RESULTS: Mean age was 64 ± 7 years and all patients were men. The target lesion was located in the right (67%) or left anterior descending (33%) coronary artery. A filter was utilized in eight patients (89%) and proximal embolic protection in one (11%). In one patient two filters were required because the originally placed filter became obstructed with debris after initial stent placement. The mean percent angiographic stenosis prestenting and poststenting was 87% ± 9% and 2% ± 4%, respectively and final TIMI 3 flow was achieved in all patients. Embolized material was retrieved in eight of nine patients (89%) and consisted mainly of platelet and fibrin thrombi. The mean target segment lipid core burden index decreased from 395 ± 114 before stenting to 152 ± 106 after stenting (P < 0.001) and the lesion angular extent decreased from 312° ± 70° to 240° ± 90° (P = 0.07). Postprocedural MI occurred in two of nine patients (22%), in one of whom two filters were required. CONCLUSION: Use of EPDs frequently resulted in embolized material retrieval after stenting of native coronary artery lesions with large LCPs. These findings support further study of EPDs as a means to prevent poststenting MI.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/química , Vasos Coronarios/patología , Dispositivos de Protección Embólica , Embolia/prevención & control , Lípidos/análisis , Intervención Coronaria Percutánea/instrumentación , Placa Aterosclerótica , Espectroscopía Infrarroja Corta , Stents , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Embolia/etiología , Embolia/metabolismo , Embolia/patología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Intervención Coronaria Percutánea/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 80(7): 1120-6, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-22422709

RESUMEN

BACKGROUND: Although embolic protection devices (EPDs) have been shown to be beneficial in saphenous vein graft (SVG) lesions, their role in the subgroup of ostial SVG lesions has received limited study. METHODS: The coronary angiograms and procedural outcomes of 109 patients undergoing stenting of 113 ostial SVG lesions were retrospectively reviewed to determine the frequency of EPD use and the periprocedural outcomes. RESULTS: Ninety-eight (87%) of the 113 lesions were suitable for EPD use, that was used in 70 lesions (71%). A Filterwire (Boston Scientific) or a SPIDER (ev3) filter were used in 54 (77%) and 16 (23%) of lesions, respectively. Difficulty retrieving the filter post stenting was encountered in eight lesions (11%) and led to stent thrombosis causing cardiac arrest in one patient (1%). Angiographic success was achieved in 111 (98%) of 113 lesions. CONCLUSIONS: EPDs can be utilized in the majority of ostial SVG lesions, but in 11% of cases filter retrieval can be challenging and may rarely (in approximately 1%) lead to a significant complication.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Dispositivos de Protección Embólica , Oclusión de Injerto Vascular/terapia , Intervención Coronaria Percutánea/instrumentación , Vena Safena/trasplante , Anciano , Distribución de Chi-Cuadrado , Angiografía Coronaria , Puente de Arteria Coronaria/mortalidad , Remoción de Dispositivos , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/mortalidad , Paro Cardíaco/etiología , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Vena Safena/diagnóstico por imagen , Stents , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 74(1): 22-5, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19530179

RESUMEN

Knowing the location of the vertebral and the internal mammary artery ostia is crucial during proximal subclavian artery percutaneous intervention to prevent inadvertent injury to either artery. We report a case of severe proximal left subclavian artery stenosis in a patient with a three-vessel disease referred to coronary artery bypass graft surgery. Retrograde angiography via left radial access allowed visualization of the left internal mammary artery and the left vertebral artery ostia and placement of a Filterwire in the left vertebral artery. The proximal left subclavian artery was successfully stented without complications. Debris was retrieved in the Filterwire.


Asunto(s)
Angioplastia de Balón , Embolia/prevención & control , Filtración/instrumentación , Síndrome del Robo de la Subclavia/terapia , Arteria Vertebral/diagnóstico por imagen , Angiografía de Substracción Digital , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Puente de Arteria Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/cirugía , Embolia/etiología , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Stents , Síndrome del Robo de la Subclavia/complicaciones , Síndrome del Robo de la Subclavia/diagnóstico por imagen , Resultado del Tratamiento
14.
Cardiovasc Revasc Med ; 17(7): 444-449, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27133499

RESUMEN

BACKGROUND: There is limited information on optical coherence tomography (OCT) findings after percutaneous coronary intervention (PCI) of chronic total occlusions (CTOs). OCT allows high resolution imaging that can enhance understanding of the vascular response after stenting of chronically occluded vessels. METHODS: The Angiographic Evaluation of the Everolimus-Eluting Stent in Chronic Total Occlusions (ACE-CTO) study collected angiographic and clinical outcomes from 100 patients undergoing CTO PCI with the everolimus-eluting stent (EES). OCT was performed 8-months post stenting in 62 patients. Every third frame was analyzed throughout the course of the stented arterial segment. Lumen contours were semi-automatically traced and stent struts were manually delineated, with automatic measurement of the strut to lumen distance. Struts on the luminal side of the lumen contour were classified as malapposed if the distance to the lumen contour exceeded 0.108mm. RESULTS: A total of 44,450 struts in 6047 frames were analyzed, of which 4113 9.3%, 95% confidence intervals [CI] 9.0% to 9.5%) were malapposed and 1230 (2.8%, 95% CI 2.6% to 2.9%) were uncovered. Fifty-five of 62 patients (88.7%, 95% CI 78.5% to 98.4%) had at least one malapposed stent strut and 50 patients (80.7%, 95% CI 69.2% to 88.6%) had at least one uncovered stent strut. Mean strut-intimal thickness of the apposed and malapposed struts was 0.126±0.140mm and -0.491±0.440mm, respectively. CONCLUSION: High rates of stent strut malapposition and incomplete stent strut coverage were observed after CTO PCI using EES, highlighting unique challenges associated with stent implantation in CTOs.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Anciano , Enfermedad Crónica , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Cicatrización de Heridas
15.
J Invasive Cardiol ; 27(9): 393-400, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26332874

RESUMEN

BACKGROUND: There are limited data on outcomes after implantation of second-generation drug-eluting stents in coronary chronic total occlusions (CTOs). We aimed to evaluate the frequency of angiographic restenosis and clinical outcomes after implantation of the everolimus-eluting stent (EES) in coronary CTOs. METHODS: One hundred patients undergoing successful CTO percutaneous coronary intervention using EES at our institution between 2009 and 2012 were enrolled. The primary study endpoint was binary in-segment restenosis at 8-month follow-up quantitative coronary angiography. Secondary endpoints included death, myocardial infarction, target-lesion and target-vessel revascularization, and symptom improvement. RESULTS: Mean age was 64 ± 7 years and 99% of the patients were men. The successful crossing technique was antegrade wiring in 51 patients, antegrade dissection/reentry in 24 patients, and retrograde in 25 patients. Binary angiographic restenosis occurred in 46% of the patients (95% confidence interval [CI], 35%-57%). The pattern of restenosis was focal, proliferative, and total occlusion in 19 lesions (46%), 14 lesions (34%), and 8 lesions (20%), respectively. At 12 months, the incidences of death, myocardial infarction, target-lesion revascularization, and target-vessel revascularization were 2%, 2%, 37%, and 39%, respectively. At 12 months, symptoms were improved, unchanged, or worse compared with baseline in 89 patients, 8 patients, and 1 patient, respectively (2 patients died before the 12-month follow-up). On multivariable analysis, smaller stent diameter was associated with higher risk for binary angiographic restenosis. CONCLUSION: High rates of angiographic restenosis and repeat revascularization were observed among patients receiving EES in coronary CTOs, but most had significant symptom improvement.


Asunto(s)
Oclusión Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Everolimus/farmacología , Intervención Coronaria Percutánea , Anciano , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/cirugía , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Reestenosis Coronaria/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Evaluación de Síntomas , Factores de Tiempo , Estados Unidos/epidemiología , Grado de Desobstrucción Vascular
16.
J Invasive Cardiol ; 27(2): 78-84, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25661758

RESUMEN

BACKGROUND: The frequency and outcomes of "balloon-uncrossable" coronary chronic total occlusions (CTOs) have received limited study. METHODS: We retrospectively examined 373 consecutive CTO percutaneous coronary interventions (PCIs) performed at our institution between 2005 and 2013 to determine the frequency and treatment of balloon-uncrossable CTOs. RESULTS: Mean age was 63.7 ± 8.3 years and 98.9% of the patients were men. Twenty-four patients (6.4%, 95% confidence intervals 4.2% to 9.4%) were found to have a balloon-uncrossable CTO. Compared to the other CTO PCI patients, those with balloon-uncrossable CTOs had similar clinical and angiographic characteristics. Successful crossing of the balloon-uncrossable CTO was achieved in 22 of 24 patients (91.7%) using a variety of techniques, such as successive balloon inflations (43.5%), microcatheter advancement (21.7%), laser (8.7%), techniques that increase guide catheter support (13.0%), and subintimal lesion crossing (13.0%). Patients with balloon-uncrossable CTOs had longer procedure time (184.5 ± 77.9 vs 134.0 ± 69.0 min, P<.01), fluoroscopy time (55.2 ± 24.9 vs 37.9 ± 20.8 min, P<.01), and received high contrast volume (404.4 ± 137.9 vs 351.7 ± 138.5 mL, P=.08), but had similar incidence of major complications (8.3% vs 3.2%, P=.25) as compared with patients who did not have balloon-uncrossable CTOs. CONCLUSION: Balloon-uncrossable CTOs are encountered in 6.4% of contemporary CTO PCIs and can be successfully treated in most patients using a variety of techniques.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres , Oclusión Coronaria/cirugía , Angioplastia Coronaria con Balón/estadística & datos numéricos , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
17.
JACC Cardiovasc Interv ; 7(1): 47-54, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24332422

RESUMEN

OBJECTIVES: This study sought to evaluate the incidence, correlates, and clinical implications of periprocedural myocardial injury (PMI) during percutaneous coronary intervention (PCI) of chronic total occlusions (CTO). BACKGROUND: The risk of PMI during CTO PCI may be underestimated because systematic cardiac biomarker measurement was not performed in published studies. METHODS: We retrospectively examined PMI among 325 consecutive CTO PCI performed at our institution between 2005 and 2012. Creatine kinase-myocardial band fraction and troponin were measured before PCI and 8 to 12 h and 18 to 24 h after PCI in all patients. PMI was defined as creatine kinase-myocardial band increase ≥ 3 x the upper limit of normal. Major adverse cardiac events during mid-term follow-up were evaluated. RESULTS: Mean age was 64 ± 8 years. The retrograde approach was used in 26.8% of all procedures. The technical and procedural success was 77.8% and 76.6%, respectively. PMI occurred in 28 patients (8.6%, 95% confidence intervals: 5.8% to 12.2%), with symptomatic ischemia in 7 of those patients. The incidence of PMI was higher in patients treated with the retrograde than the antegrade approach (13.8% vs. 6.7%, p = 0.04). During a median follow-up of 2.3 years, compared with patients without PMI, those with PMI had a higher incidence of major adverse cardiac events (hazard ratio [HR]: 2.25, p = 0.006). Patients with only asymptomatic PMI also had a higher incidence of major adverse cardiac events on follow-up (HR: 2.26, p = 0.013). CONCLUSIONS: Systematic measurement of cardiac biomarkers post-CTO PCI demonstrates that PMI occurs in 8.6% of patients, is more common with the retrograde approach, and is associated with worse subsequent clinical outcomes during mid-term follow-up.


Asunto(s)
Oclusión Coronaria/terapia , Forma MB de la Creatina-Quinasa/sangre , Cardiopatías/sangre , Intervención Coronaria Percutánea/efectos adversos , Troponina/sangre , Anciano , Biomarcadores/sangre , Enfermedad Crónica , Oclusión Coronaria/diagnóstico , Femenino , Cardiopatías/diagnóstico , Cardiopatías/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Texas/epidemiología , Factores de Tiempo , Resultado del Tratamiento
18.
J Invasive Cardiol ; 26(3): 100-5, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24610502

RESUMEN

OBJECTIVES: To identify clinical, angiographic, and procedural factors associated with increased risk of periprocedural complications during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). BACKGROUND: Successful CTO PCI can provide significant clinical benefit; however, procedural risks have received limited study. We sought to identify factors associated with increased CTO PCI periprocedural risk that could be utilized to guide patient and lesion selection. METHODS: The clinical, angiographic, and procedural records of 336 consecutive CTO PCI procedures performed at a single center from May 2005 through 2012 were reviewed, and data on periprocedural complications were recorded. Logistic regression was performed to identify independent predictors of periprocedural complications during CTO PCI. RESULTS: The incidence of major and minor complications was 3.9% and 10.4%, respectively. Minor bleeding and vascular events were the most common complications (4.8%), followed by perforation (2.4%), contrast-induced nephropathy (1.8%), and transient hypotension (0.6%). Major complications were uncommon: death (0.3%); emergency coronary artery bypass grafting (0.6%); stroke (0.3%); tamponade (0.3%); clinical myocardial infarction (0.9%); donor vessel injury (0.6%); and major bleeding or vascular events (0.9%). Patients who experienced any complication had higher preprocedure troponin levels and were more likely to undergo treatment using the retrograde approach. In multivariable analysis, use of the retrograde approach was independently associated with increased risk of periprocedural complications (odds ratio, 2.057; 95% confidence interval, 1.045-4.051; P=.04). CONCLUSIONS: Major complications of CTO PCI are infrequent, but are more common with use of the retrograde approach.


Asunto(s)
Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias/epidemiología , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/epidemiología , Anciano , Medios de Contraste/efectos adversos , Femenino , Hemorragia/epidemiología , Humanos , Hipotensión/epidemiología , Incidencia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Lesiones del Sistema Vascular/epidemiología
19.
J Invasive Cardiol ; 26(9): 437-42, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25198487

RESUMEN

OBJECTIVES: To determine the impact of music intervention on endothelial function, hemodynamics, and patient anxiety before, during, and after cardiac catheterization. BACKGROUND: The effect of music therapy during cardiac catheterization on endothelial function and patient satisfaction has received limited study. METHODS: Seventy patients undergoing elective cardiac catheterization were randomized to music therapy (n=36) or no music therapy (n=34). Peripheral arterial tonometry was performed before and after catheterization. A 6 item (24-point scale) questionnaire evaluating patient anxiety and discomfort levels was also administered after the procedure. RESULTS: Both study groups had similar baseline characteristics, fluoroscopy time, and contrast administration. Reactive hyperemia index (RHI) change was 0.14 ± 0.72 in the music group and 0.30 ± 0.58 in the control group (P=.35). Systolic and diastolic blood pressure (BP) changes did not significantly differ between the two groups (systolic BP change -3.3 ± 17.3 mm Hg vs -2.3 ± 19.4 mm Hg; P=.83 and diastolic BP change -1.9 ± 12.2 mm Hg vs. 2.0 ± 13.4 mm Hg; P=.23). Heart rate changes were also comparable between the two groups (-1 ± 6 beats/ min vs -1 ± 7 beats/min; P=.22). Patient satisfaction questionnaire measurements were found to be similar in patients with and without music therapy (8 [7-11] vs 9 [8-12]; P=.36). CONCLUSIONS: In this study, music intervention did not elicit a vasodilator response, did not lower blood pressure or heart rate, and did not relieve anxiety or stress discomfort in patients who underwent coronary angiography.


Asunto(s)
Cateterismo Cardíaco/psicología , Enfermedades Cardiovasculares/terapia , Endotelio Vascular/fisiopatología , Hiperemia/epidemiología , Musicoterapia , Satisfacción del Paciente , Anciano , Ansiedad/fisiopatología , Presión Sanguínea/fisiología , Enfermedades Cardiovasculares/fisiopatología , Femenino , Frecuencia Cardíaca/fisiología , Hemodinámica/fisiología , Humanos , Hiperemia/fisiopatología , Incidencia , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios , Resultado del Tratamiento
20.
Int J Cardiol ; 174(2): 243-8, 2014 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-24768461

RESUMEN

BACKGROUND: The efficacy and safety profile of retrograde chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. We sought to perform a weighted meta-analysis of the success and complication rates of retrograde CTO PCI. METHODS: We conducted a meta-analysis of 26 studies published between 2006 and April 2013 reporting in-hospital outcomes of retrograde CTO PCI. Data on procedural success, frequency of death, emergent coronary artery bypass graft surgery (CABG), stroke, myocardial infarction (MI), perforation, tamponade, stent thrombosis, major vascular or bleeding events, contrast nephropathy, and radiation skin injury were collected. RESULTS: A total of 26 studies with 3482 patients and 3493 target CTO lesions were included. Primary retrograde CTO PCI was attempted in 52.4%. Pooled estimates of outcomes were as follows: procedural success 83.3% [95% confidence interval (CI): 79.0% to 87.7%]; death 0.7% (95% CI: 0.5% to 1.2%); urgent CABG 0.7% (95% CI: 0.4% to 1.2%); tamponade 1.4% (95% CI: 1.0% to 2.2%); collateral perforation 6.9% (95% CI: 4.6% to 10.4%); coronary perforation 4.3% (95% CI: 1.2% to 15.4%); donor vessel dissection 2% (95% CI: 0.9% to 4.5%); stroke 0.5% (95% CI: 0.2% to 1.0%); MI 3.1% (95% CI: 0.2% to 5.0%); Q wave MI 0.6% (95% CI: 0.4% to 1.1%); vascular access complications 2% (95% CI: 0.9% to 4.5%); contrast nephropathy 1.8% (95% CI: 0.8% to 3.7%); and wire fracture and equipment entrapment 1.2% (95% CI: 0.6% to 2.5%). CONCLUSIONS: Retrograde CTO PCI is associated with high procedural success rate and acceptable risk for procedural complications.


Asunto(s)
Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/efectos adversos , Humanos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Inducción de Remisión