Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 891-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26899899

RESUMEN

PURPOSE: Many eye diseases require on-going assessment for optimal management, creating an ever-increasing burden on patients and hospitals that could potentially be reduced through home vision monitoring. However, there is limited evidence for the utility of current applications and devices for this. To address this, we present a new automated, computer tablet-based method for self-testing near visual acuity (VA) for both high and low contrast targets. We report on its reliability and agreement with gold standard measures. METHODS: The Mobile Assessment of Vision by intERactIve Computer (MAVERIC) system consists of a calibrated computer tablet housed in a bespoke viewing chamber. Purpose-built software automatically elicits touch-screen responses from subjects to measure their near VA for either low or high contrast acuity. Near high contrast acuity was measured using both the MAVERIC system and a near Landolt C chart in one eye for 81 patients and low contrast acuity using the MAVERIC system and a 25 % contrast near EDTRS chart in one eye of a separate 95 patients. The MAVERIC near acuity was also retested after 20 min to evaluate repeatability. RESULTS: Repeatability of both high and low contrast MAVERIC acuity measures, and their agreement with the chart tests, was assessed using the Bland-Altman comparison method. One hundred and seventy-three patients (96 %) completed the self- testing MAVERIC system without formal assistance. The resulting MAVERIC vision demonstrated good repeatability and good agreement with the gold-standard near chart measures. CONCLUSIONS: This study demonstrates the potential utility of the MAVERIC system for patients with ophthalmic disease to self-test their high and low contrast VA. The technique has a high degree of reliability and agreement with gold standard chart based measurements.


Asunto(s)
Computadoras de Mano , Sensibilidad de Contraste/fisiología , Diagnóstico por Computador/instrumentación , Autocuidado/métodos , Trastornos de la Visión/diagnóstico , Pruebas de Visión/instrumentación , Agudeza Visual/fisiología , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA