RESUMEN

BACKGROUND: Trunnionosis of the tapered head-stem junction of total hip arthroplasties, either through corrosion or mechanical wear, has been implicated in early implant failure. Retrieval analysis of large numbers of failed implants can help us better understand the factors that influence damage at this interface. METHODS: In this study, we examined 120 retrieved total hip arthroplasties of one bearing design, the 36-mm diameter metal-on-metal, DePuy Pinnacle, that had been paired with 3 different stems. We measured material loss of the bearing and head-trunnion taper surfaces and collected clinical and component data for each case. We then used multiple linear regression analysis to determine which factors influenced the rate of taper material loss. RESULTS: We found 4 significant variables: (1) longer time to revision (P = .004), (2) the use of a 12/14 taper for the head-trunnion junction (P < .001), (3) decreased bearing surface wear (P = .003), and (4) vertical femoral offset (P = .05). These together explained 29% of the variability in taper material loss. CONCLUSION: Our most important finding is the effect of trunnion design. Of the 3 types studied, we found that S-ROM design was the most successful at minimizing trunnionosis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Falla de Prótesis , Adulto , Anciano , Corrosión , Remoción de Dispositivos , Femenino , Fémur/cirugía , Humanos , Masculino , Metales/efectos adversos , Persona de Mediana Edad , Diseño de Prótesis
2.
J Arthroplasty ; 31(6): 1261-1266, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26775067

RESUMEN

BACKGROUND: Adverse soft tissue reactions in metal-on-metal (MoM) hip replacements are associated with cobalt (Co) and chromium (Cr) ions in blood. We report the prevalence and risk factors for elevated blood Co and Cr levels in patients with a unilateral MoM hip. METHODS: From a single institution, blood Co and Cr levels were analyzed in 1748 patients (692 hip resurfacings and 1056 total hip arthroplasties [THAs]). Concentrations exceeding 7 ppb were considered elevated, and the risk factors for elevated levels were calculated with binary logistic regression. RESULTS: Elevated blood metal ion levels were more common in MoM THA than in resurfacing patients (17.4% vs 5.9%, P < .001), and in 5 of the 7 THA brands, more than 20% of patients had elevated metal ion concentrations, whereas the proportion was less than 10% in all hip resurfacings. In resurfacings, small femoral head (odds ratio [OR] 1.30 per millimeter decrease [CI, 1.12-1.49]), high acetabular inclination (OR 1.15 per degree increase [CI 1.09-1.22]), and young age (OR 1.05 per year decrease [1.02-1.10]) were independent risk factors for elevated ions. In the THA group, female gender (OR 2.04 [CI 1.35-3.06]), longer time between surgery and ion measurement (OR 1.19 per year increase [CI 1.05-1.34]), and large headsize (OR 1.07 per millimeter increase [CI 1.01-1.13]) were risk factors for elevated ions. CONCLUSION: Given the high percentage of elevated levels, the systematic surveillance of especially large diameter MoM THAs seems justified.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo/sangre , Cobalto/sangre , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Anciano , Femenino , Humanos , Iones , Masculino , Metales , Persona de Mediana Edad , Análisis Multivariante , Rango del Movimiento Articular , Factores de Riesgo