1.
PLoS One ; 19(4): e0301753, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38578782

RESUMEN

BACKGROUND: Atrial arrhythmias (AA) commonly affect patients with cardiac amyloidosis (CA) and are a contributing risk factor for the development of heart failure (HF). This study sought to investigate the long-term efficacy and impact of catheter ablation on HF progression in patients with CA and AA. METHODS: Thirty-one patients with CA and AA undergoing catheter ablation were retrospectively included (transthyretin-ATTR CA 61% and light chain-AL CA 39%). AA subtypes included atrial fibrillation (AFib) in 22 (paroxysmal in 10 and persistent in 12), atrial flutter (AFl) in 17 and atrial tachycardia (AT) in 11 patients. Long-term AA recurrence rates were evaluated along with the impact of sinus rhythm (SR) maintenance on HF and mortality. RESULTS: AA recurrence was observed in 14 patients (45%) at a median of 3.5 months (AFib n = 8, AT n = 6, AFl = 0). Post-cardioversion, medical therapy or catheter ablation, 10 patients (32%) remained in permanent AA. Over a median follow-up of 19 months, all-cause mortality was 39% (n = 12): 3 with end-stage HF, 5 due to late complications of CA, 1 sudden cardiac death, 1 stroke, 1 COVID 19 (and one unknown). With maintenance of SR following catheter ablation, significant reductions in serum creatinine and natriuretic peptide levels were observed with improvements in NYHA class. Two patients required hospitalization for HF in the SR maintenance cohort compared to 5 patients in the AA recurrence cohort (p = 0.1). All 3 patients with deaths secondary to HF had AA recurrence compared to 11 out of the 28 patients whom were long-term survivors or deaths not related to HF (p = 0.04). All-cause mortality was not associated with AA recurrence. CONCLUSION: This study demonstrates moderate long-term efficacy of SR maintenance with catheter ablation for AA in patients with CA. Improvements in clinical and biological status with positive trends in HF mortality are observed if SR can be maintained.


Asunto(s)
Amiloidosis , Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Amiloidosis/complicaciones , Amiloidosis/cirugía , Ablación por Catéter/efectos adversos
2.
Arch Cardiovasc Dis ; 117(4): 244-248, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38490843

RESUMEN

BACKGROUND: The true incidence of sudden death remains undetermined, with controversial results from various publications over time and countries. AIM: To investigate if different estimations would reach the values usually reported for France. METHODS: Three different kinds of estimations were used. First, the number of resuscitated sudden deaths and necropsies for sudden death in the Haute-Garonne French administrative department (i.e. county) over the last 10years was expanded to the national level. Second, sudden death coding of death certificates was collected at the national level. Third, the total number of out-of-hospital cardiac arrests leading to any emergency call (with/without intervention) in Haute-Garonne over the last 10years was expanded to the national level. RESULTS: There was a mean of 26 resuscitated sudden deaths and 145 necropsies for sudden death each year in Haute-Garonne, i.e. 12 to 14 sudden deaths for 100,000 inhabitants, and 7700 to 9400 sudden deaths yearly when related to the whole French population, according to the year of inclusion. Based on death certificates, a mean of 6584 sudden deaths was registered each year in France. Finally, there were about 600 yearly calls/interventions for out-of-hospital cardiac arrests in Haute-Garonne, i.e. 40 to 50 sudden deaths for 100,000 inhabitants, and 16,000 to 27,000 sudden deaths yearly for the whole French territory, according to the year of inclusion. CONCLUSIONS: The incidence of sudden death ranges from 6500 to 27,000 in France according to the calculation methods. This huge difference raises the question of the true current incidence of sudden death, which may have been overestimated previously or may be underestimated in France. More straight prospective surveys are needed to solve this question, because of relevant implications for priorities that should be given to sudden death.


Asunto(s)
Paro Cardíaco Extrahospitalario , Humanos , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/epidemiología , Paro Cardíaco Extrahospitalario/terapia , Incidencia , Estudios Prospectivos , Muerte Súbita , Francia/epidemiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control
3.
Heart Rhythm ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38810921

RESUMEN

BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA