RESUMEN
INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Frecuencia Cardíaca , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Criocirugía/efectos adversos , Ablación por Catéter/efectos adversos , Factores de Tiempo , Potenciales de Acción , Vena Cava Superior/cirugía , Vena Cava Superior/fisiopatología , Sistema Nervioso Autónomo/fisiopatología , Sistema Nervioso Autónomo/cirugía , Estudios Retrospectivos , Factores de RiesgoRESUMEN
AIMS: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF > 6â m) and long-standing persistent AF (LSPAF). METHODS AND RESULTS: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). Seventy-two [age:68 ± 10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF > 6â m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112 ± 25â min and 59 ± 22â min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9 ± 2.7 months of follow-up; AF-free survival was 89.2%. CONCLUSION: In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favourable clinical outcomes were observed during >1 year of follow-up.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Humanos , Masculino , Ablación por Catéter/métodos , Femenino , Anciano , Persona de Mediana Edad , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia , Factores de Tiempo , Catéteres Cardíacos , Frecuencia Cardíaca , Potenciales de AcciónRESUMEN
INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Sistema Nervioso Autónomo/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Nervio Vago/cirugía , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Resultado del TratamientoRESUMEN
AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Resultado del Tratamiento , Estudios de Seguimiento , Estudios Prospectivos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Taquicardia/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , RecurrenciaRESUMEN
AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Enfermedad de la Arteria Coronaria , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , RecurrenciaRESUMEN
AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.
Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Seguimiento , Atrios Cardíacos , Estudios Retrospectivos , Taquicardia , Resultado del TratamientoRESUMEN
AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.
Asunto(s)
Síndrome de Brugada , Adulto , Humanos , Niño , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Pruebas Genéticas , Arritmias Cardíacas/genética , Cardioversión Eléctrica , Pronóstico , Electrocardiografía/métodos , Canal de Sodio Activado por Voltaje NAV1.5/genéticaRESUMEN
AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Puntaje de Propensión , Resultado del Tratamiento , Atrios Cardíacos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , RecurrenciaRESUMEN
BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Criocirugía/métodos , Estudios de Factibilidad , Resultado del Tratamiento , Ablación por Catéter/métodos , Recurrencia , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , CatéteresRESUMEN
BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.
Asunto(s)
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Pruebas Genéticas , Arritmias Cardíacas/genética , Mutación Missense , Canal de Sodio Activado por Voltaje NAV1.5/genética , MutaciónRESUMEN
BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Nervio Vago , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Frecuencia Cardíaca/fisiología , Nervio Vago/fisiopatología , Nervio Vago/fisiología , Estudios Prospectivos , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Resultado del Tratamiento , Ganglios Autónomos/fisiopatología , Ganglios Autónomos/cirugía , Estudios de SeguimientoRESUMEN
Previous clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall (PW) when facing the esophagus region. Here, we retrospectively assess whether 15 s of RF delivery time on posterior electrodes is safe while still ensuring lesion metrics of sufficient quality. This retrospective study included 133 patients with paroxysmal and persistent atrial fibrillation who underwent PVI using an RFB (Heliostar, Biosense Webster, Inc., Irvine, CA, USA) at two European centers. The ablation protocol was set for an RF duration of 20 s/60 s for the posterior/anterior electrodes. A multielectrode temperature probe was systematically used. In the case of an esophageal temperature rise (ETR) above 42 °C (ETR+), an endoscopic evaluation was performed. All posterior electrode lesion metric dynamics (temperature (T) and impedance (Z)) were collected from the RFB generator and analyzed offline. In total, 2435 posterior electrode applications were analyzed. With an RF delivery of 19.8 (19.7-19.8) s, the median impedance drop was 18.4 (12.2-25.2) Ω, while the temperature rise was 11.1 (7.1-14.9) °C. Accordingly, impedance (84.6 (79.3-90.2) Ω) and temperature plateaus (38 (35.3-41.1) °C) were reached at 13.9 (10.6-16) s and 16.4 (12.6-18.5) s, respectively. Overall, 99.6% and 95.8% of electrodes reached 90% (16.6 Ω) and 95% (17.5 Ω) of their impedance drops within 15 s of RF delivery, while 97.2% and 92.8% achieved 90% (34.2 °C) and 95% (36.1 °C) of their temperature rise to reach the plateaus within 15 s of RF delivery. An ETR >42 °C occurred in 37 (30.1%) patients after 17.7 ± 2.3 s of RF delivery. In the ETR+ group, the impedance drop and temperature rise on the posterior electrodes were higher compared to patients where ETR was <42 °C. Two asymptomatic thermal esophageal injuries were observed. In conclusion, 15 s of RF delivery on the posterior electrodes provides a good balance between safety, with no esophageal temperature rise, and efficacy with high-profile lesion metrics.
RESUMEN
BACKGROUND: Patients with Brugada syndrome (BrS) have an increased risk of arrhythmias, including atrial tachyarrhythmias (ATas). OBJECTIVES: The purpose of this study was to assess underlying atrial cardiomyopathy in BrS and the effect of ajmaline (AJM) test on the atrium of BrS patients using electrocardiogram imaging (ECGI). METHODS: All consecutive patients diagnosed with BrS in a monocentric registry were screened and included if they met the following criteria: 1) BrS diagnosed following current recommendations; and 2) ECGI map performed before and after AJM with a standard protocol. Consecutive patients with no structural heart disease or BrS who had undergone ECGI were included as a control group. Genetic analysis for SCN5A was performed in all BrS patients. Total atrial conduction time (TACT) and local atrial conduction time (LACT) were calculated from atrial ECGI. The primary endpoint was ATas during follow-up. RESULTS: Forty-three consecutive BrS patients and 40 control patients were included. Both TACT and LACT were significantly prolonged in BrS patients compared with control patients. Furthermore, TACT and LACT were significantly higher after AJM administration and in BrS patients who were carriers of a pathogenic/likely pathogenic SCN5A variant. After a mean follow-up of 40.9 months, 6 patients experienced a first ATa occurrence (all in the BrS group, 13.9%). TACT was the only independent predictor of ATas with a cutoff of >138.5 ms (sensitivity 0.92 [95% CI: 0.83-0.98], specificity 0.70 [95% CI: 0.59-0.81]). CONCLUSIONS: ECGI-calculated TACT and LACT are significantly prolonged in BrS patients compared with control patients, and in BrS patients after AJM. This may be consistent with a concealed atrial cardiomyopathy in BrS.
Asunto(s)
Fibrilación Atrial , Síndrome de Brugada , Cardiomiopatías , Humanos , Síndrome de Brugada/diagnóstico por imagen , Síndrome de Brugada/genética , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Electrocardiografía/métodos , AjmalinaRESUMEN
BACKGROUND: This study aimed to evaluate the feasibility and safety of an innovative "all in one" integrated transseptal crossing device to achieve transseptal puncture (TSP). METHODS: Twenty patients (10 males, mean age 65.65 ± 9.25 years), indicated to supraventricular left side tachyarrhythmia ablation, underwent TSP using a new-generation integrated crossing device, and a control cohort of twenty patients (10 males, mean age 65.5 ± 10.12 years) underwent TSP using the traditional TSP system. RESULTS: In all the study patients, the novel TSP device led to a successful and safe access to the left atrium (LA). The mean transseptal time, defined as the time occurring between the groin puncture and the advancing of the guidewire into the left superior pulmonary vein (PV), was 3 min 33 s ± 44 s, 7 min 5 s ± 36 s in the control cohort. Additionally, we compared the cost of the two systems. No acute complications related to the TSP were noted in both cohorts. CONCLUSIONS: TSP performed with the new integrated transseptal system is feasible and safe.
Asunto(s)
Humanos , Persona de Mediana Edad , AncianoRESUMEN
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim of combining the advantages of a thoracoscopic surgical ablation (direct visualization of anatomical structures to be spared and the possibility to perform epicardial lesions) and endocardial ablation (possibility to check line block, confirm PVI, and possibility to perform cavotricuspid isthmus ablation). Patient selection is of utmost importance. In persistent and long-term persistent AF, hybrid AF ablation demonstrated promising results in terms of AF free survival. It has been associated with a relatively low complication rate if performed in centers with expertise in hybrid procedures and experience with both surgical and endocardial ablation. Different techniques have been described, with different approaches and lesion sets. The aim of this review is to provide a state-of-the-art overview of hybrid AF ablation.
RESUMEN
Management of ventricular arrhythmias (VAs) beyond implantable cardioverter-defibrillator positioning in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) is challenging. Catheter ablation of the ventricular substrate often requires a combination of endocardial and epicardial approaches, with disappointing outcomes due to the progressive nature of the disease. We report the Universitair Ziekenhuis Brussel experience through a case series of 16 patients with drug-refractory ARVC, who have undergone endocardial and/or epicardial catheter ablation of VAs with a thoracoscopic hybrid-approach. After a mean follow-up time of 5.16 years (SD 2.9 years) from the first hybrid-approach ablation, VA recurrence was observed in 5 patients (31.25%): among these, patients 4 patients (80%) received a previous ablation and 1 of 11 patients (9.09%) who had a hybrid ablation as first approach had a VA recurrence (80% vs 9.09%; log-rank p = 0.04). Despite the recurrence rate of arrhythmic events, all patients had a significant reduction in the arrhythmic burden after ablation, with a mean of 4.65 years (SD 2.9 years) of freedom from clinically significant arrhythmias, defined as symptomatic VAs or implantable cardioverter-defibrillator-delivered therapies. In conclusion, our case series confirms that management of VAs in patients with ARVC is difficult because patients do not always respond to antiarrhythmic medications and can require multiple invasive procedures. A multidisciplinary approach involving cardiologists, cardiac surgeons, and cardiac electrophysiologists, together with recent cardiac mapping techniques and ablation tools, might mitigate these difficulties and improve outcomes.
Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Ablación por Catéter , Taquicardia Ventricular , Displasia Ventricular Derecha Arritmogénica/cirugía , Ablación por Catéter/métodos , Humanos , Recurrencia , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Resultado del TratamientoRESUMEN
Background: Coronavirus disease 2019 (COVID-19) is a systemic disease caused by severe acute respiratory syndrome coronavirus 2. Arrhythmias are frequently associated with COVID-19 and could be the result of inflammation or hypoxia. This study aimed to define the incidence of arrhythmias in patients with COVID-19 and to correlate arrhythmias with pulmonary damage assessed by computed tomography (CT). Methods: All consecutive patients with a COVID-19 diagnosis hospitalized at Universitair Ziekenhuis Brussel, Belgium, between March 2020 and May 2020, were screened. All included patients underwent a thorax CT scan and a CT severity score, a semiquantitative scoring system of pulmonary damage, was calculated. The primary endpoint was the arrhythmia occurrence during follow-up. Results: In this study, 100 patients were prospectively included. At a mean follow-up of 19.6 months, 25 patients with COVID-19 (25%) experienced 26 arrhythmic episodes, including atrial fibrillation in 17 patients, inappropriate sinus tachycardia in 7 patients, atrial flutter in 1 patient, and third-degree atrioventricular block in 1 patient. No ventricular arrhythmias were documented. Patients with COVID-19 with arrhythmias showed more often need for oxygen, higher oxygen maximum flow, longer QTc at admission, and worse damage at CT severity score. In univariate logistic regression analysis, significant predictors of the primary endpoint were: the need for oxygen therapy (odds ratio [OR] 4.59, 95% CI 1.44-14.67, p = 0.01) and CT severity score of pulmonary damage (OR per 1 point increase 1.25, 95% CI 1.11-1.4, p < 0.001). Conclusions: In a consecutive cohort of patients with COVID-19 the incidence of cardiac arrhythmias was 25%. The need for oxygen therapy and CT severity score were predictors of arrhythmia occurrence during follow-up.
RESUMEN
BACKGROUND: Coronary sinus (CS) ostial atresia/abnormalities prevent access to the CS from the right atrium (RA) for left ventricular (LV) lead implantation. Some patients with CS ostial abnormalities also have a small persistent left superior vena cava (sPLSVC). OBJECTIVE: The purpose of this study was to describe CS ostial abnormalities and sPLSVC as an opportunity for LV lead implantation and unrecognized source of stroke. METHODS: Twenty patients with CS ostial abnormalities and sPLSVC were identified. Clinical information, imaging methods, LV lead implantation techniques, and complications were summarized. RESULTS: Forty percent had at least 1 previously unsuccessful LV lead placement. In 70%, sPLSVC was identified by catheter manipulation and contrast injection in the left brachiocephalic vein, and in 30% by levophase CS venography. In 30%, sPLSVC was associated with drainage from the CS into the left atrium (LA). When associated with CS ostial abnormalities, the sPLSVC diameter averaged 5.6 ± 3 mm. sPLSVC was used for successful LV lead implantation in 90% of cases. In 80%, the LV lead was implanted down sPLSVC, and in 20%, sPLSVC was used to access the CS from the RA. Presumably because of unrecognized drainage from the CS to the LA, 1 patient had a stroke during implantation via sPLSVC. CONCLUSION: When CS ostial abnormalities prevent access to the CS from the RA, sPLSVC can be used to successfully implant LV leads. In some, the CS partially drains into the LA and stroke can occur spontaneously or during lead intervention. It is important to distinguish sPLSVC associated with CS ostial abnormalities from isolated PLSVC.