Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am Heart J ; 275: 141-150, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38876408

RESUMEN

BACKGROUND: The semiquantitative Clinical Frailty Scale (CFS) is reportedly a useful marker for predicting short- and mid-term mortality after transcatheter aortic valve implantation (TAVI). We assessed the long-term prognostic impact of CFS in patients with severe aortic stenosis undergoing TAVI. METHODS: We prospectively assessed patients undergoing TAVI in Kokura Memorial Hospital using a 9-level CFS and enrolled 1594 patients after excluding patients with CFS 8-9. The patients were divided into the low (CFS level, 1-3; N = 842), intermediate (4; N = 469), and high (5-7; N = 283) groups according to their CFS levels. RESULTS: In the low, intermediate, and high groups, 3-year all-cause mortality rates were 17.4%, 29.4%, and 41.7% (P < .001) and composite rates of cardiovascular mortality and heart failure hospitalization were 12.1%, 19.1%, and 23.9% (P < .001), respectively. Multivariable analysis showed that higher frailty was independently associated with all-cause mortality (intermediate group: adjusted hazard ratio [HR], 1.63, 95% confidence interval [CI], 1.24-2.15, P < .001; high group: adjusted HR, 2.18, 95% CI, 1.59-2.99, P < .001) and composite of cardiovascular mortality and heart failure hospitalization (intermediate group: adjusted HR, 1.47, 95% CI, 1.04-2.08, P = .030; high group: adjusted HR, 1.66, 95% CI, 1.09-2.51, P = .018) and this result was consistent, irrespective of stratification based on age, sex, body mass index, left ventricular ejection fraction, Society of Thoracic Surgeons score, and New York Heart Association functional class without significant interaction. CONCLUSIONS: The simple CFS tool predicts the long-term adverse outcomes post-TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Fragilidad/epidemiología , Fragilidad/complicaciones , Anciano de 80 o más Años , Anciano , Estudios Prospectivos , Pronóstico , Factores de Riesgo , Causas de Muerte/tendencias , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estudios de Seguimiento
2.
Int J Biol Macromol ; 265(Pt 2): 131125, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38527675

RESUMEN

The study investigates the potential of porous scaffolds with Gel/Alg-IGF-1 coatings as a viable candidate for orthopaedic implants. The scaffolds are composed of additively manufactured Ti6Al4V lattices, which were treated in an alkali solution to obtain the anatase and rutile phases. The treated surface exhibited hydrophilicity of <11.5°. A biopolymer carrier containing Insulin-like growth factor 1 was coated on the samples using immersion treatment. This study showed that the surface-modified porous Ti6Al4V scaffolds increased cell viability and proliferation, indicating potential for bone regeneration. The results demonstrate that surface modifications can enhance the osteoconduction and osteoinduction of Ti6Al4V implants, leading to improved bone regeneration and faster recovery. The porous Ti6Al4V scaffolds modified with surface coating of Gel/Alg-IGF-1 exhibited a noteworthy increase in cell viability (from 80.7 to 104.1%viability) and proliferation. These results suggest that the surface modified scaffolds have potential for use in treating bone defects.


Asunto(s)
Aleaciones , Gelatina , Factor I del Crecimiento Similar a la Insulina , Titanio , Prótesis e Implantes , Regeneración Ósea , Porosidad , Andamios del Tejido
3.
Sci Prog ; 107(2): 368504241244666, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38614461

RESUMEN

Bone extracellular matrix (ECM) proteins play a key role in bone formation and regeneration, including structural and regulatory functions. The Phylobone database consists of 255 ECM protein groups from 39 species and can be used to support bone research. Here, we gathered bone ECM proteins from reindeer (Rangifer tarandus), a member of the Cervidae family. The importance of reindeer lies in their ability to regenerate their antlers, in both male and female individuals. Protein sequences were extracted from the National Center for Biotechnology Information's repository and selected by homology searches. We identified 215 proteins and their corresponding functional domains, which are putatively present in the bone ECM of reindeer. Protein sequence alignments have shown a high degree of conservation between R. tarandus and other members of the Cervidae family. This update expands the Phylobone database and shows that it is a useful resource for the preliminary annotation of bone ECM proteins in novel proteomes.


Asunto(s)
Reno , Humanos , Animales , Femenino , Masculino , Reno/genética , Biotecnología , Bases de Datos Factuales , Proteínas de la Matriz Extracelular
4.
Int J Pharm ; 657: 124148, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38657718

RESUMEN

Layer-by-layer self-assembly systems were developed using monolayer and multilayer carriers to prevent infections and improve bone regeneration of porous Ti-6Al-4V scaffolds. These polymeric carriers incorporated (Gel/Alg-IGF-1 + Chi-Cef) and (4Gel/Alg-IGF-1 + Chi-Cef) on the surface of porous implants produced via electron beam melting (EBM). The results showed that the drug release from multilayer carriers was higher than that of monolayers after 14 days. However, the carrier containing Gel/Alg-IGF-1 + Chi-Cef exhibited more sustained behavior. Cell morphology was characterized, revealing that multilayer carriers had higher cell adhesion than monolayers. Additionally, cell differentiation was significantly greater for (Gel/Alg-IGF-1) + Chi-Cef, and (4Gel/Alg-IGF-1) + Chi-Cef multilayer carriers than for the monolayer groups after 7 days. Notably, the drug dosage was effective and did not interfere, and the cell viability assay showed safe results. Antibacterial evaluations demonstrated that both multilayer carriers had a greater effect on Staphylococcus aureus during treatment. The carriers containing lower alginate had notably less effect than the other studied carriers. This study aimed to test systems for controlling drug release, which will be applied to improve MG63 cell behavior and prevent bacterial accumulation during orthopaedic applications.


Asunto(s)
Antibacterianos , Supervivencia Celular , Portadores de Fármacos , Sistemas de Liberación de Medicamentos , Liberación de Fármacos , Staphylococcus aureus , Titanio , Staphylococcus aureus/efectos de los fármacos , Humanos , Titanio/química , Portadores de Fármacos/química , Supervivencia Celular/efectos de los fármacos , Antibacterianos/administración & dosificación , Antibacterianos/farmacología , Antibacterianos/química , Alginatos/química , Aleaciones/química , Porosidad , Diferenciación Celular/efectos de los fármacos , Línea Celular Tumoral , Andamios del Tejido/química , Adhesión Celular/efectos de los fármacos , Nanopartículas Capa por Capa
5.
JACC Case Rep ; 29(10): 102335, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38623541

RESUMEN

Patent foramen ovale (PFO) complicated with carcinoid heart disease (CHD) can cause severe hypoxia and worsening clinical conditions. We report the case of a patient with CHD in poor general condition with multiple severe valve regurgitations and PFO, who underwent successful percutaneous closure of the PFO.

6.
Colloids Surf B Biointerfaces ; 234: 113735, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38218136

RESUMEN

Microplastic (MP) pollution is a global environmental problem. To understand the biological effects of MPs on humans, it is essential to evaluate the response of human cells to model plastic particles that mimic environmental MPs in a sensitive and non-invasive manner. In this study, we investigated the preparation of poly(ethylene terephthalate) (PET) fragments with properties similar to those of environmental MPs by combining photo-oxidative degradation via ultraviolet (UV) irradiation with mechanical pulverization and hydrolysis via ultrasound (US) exposure. Combination of UV and US treatments decreased the particle size of PET fragments to 10.2 µm and increased their crystallinity and Young's modulus to 35.7 % and 0.73 GPa, respectively, while untreated PET fragments showed the particle size of 18.9 µm, the crystallinity of 33.7 %, and Young's modulus of 0.48 GPa. In addition, an increase in negative surface potential and O/C ratio were observed for UV/US-treated PET fragments, suggesting surface oxidation via UV/US treatment. Cytokine secretion from human macrophages was evaluated by a highly sensitive inflammation evaluation system using the HiBiT-based chemiluminescence detection method developed by genome editing technology. UV/US-treated PET fragments induced a 1.4 times higher level of inflammatory cytokine secretion on inflammatory macrophages than untreated ones, suggesting that the biological responses of PET fragments could be influenced by changes in material properties via oxidation. In conclusion, UV/US treatment enables efficient preparation of model plastic particles and is expected to provide new insights into the evaluation of biological effects using human cells. (240 words).


Asunto(s)
Microplásticos , Ácidos Ftálicos , Contaminantes Químicos del Agua , Humanos , Plásticos , Tereftalatos Polietilenos , Macrófagos/química , Línea Celular , Etilenos , Citocinas , Contaminantes Químicos del Agua/análisis
7.
Circ Cardiovasc Interv ; 17(2): e013094, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38152879

RESUMEN

BACKGROUND: A high permanent pacemaker implantation (PPI) risk remains a concern of self-expandable transcatheter aortic valve implantation, despite the continued improvements in implantation methodology. We aimed to assess the impact of real-time direct visualization of the membranous septum using transjugular intracardiac echocardiography (ICE) during transcatheter aortic valve implantation on reducing the rates of conduction disturbances including the need for PPI. METHODS: Consecutive patients treated with Evolut R and Evolut PRO/PRO+ from February 2017 to September 2022 were included in this study. We compared outcomes between the conventional implantation method using the 3-cusps view (3 cusps without ICE group), the recent method using cusp-overlap view (cusp overlap without ICE group), and our novel method using ICE (cusp overlap with ICE group). RESULTS: Of the 446 patients eligible for analysis, 211 (47.3%) were categorized as the 3 cusps without ICE group, 129 (28.9%) were in the cusp overlap without ICE group, and 106 (23.8%) comprised the cusp overlap with ICE group. Compared with the 3 cusps without ICE group, the cusp overlap without ICE group had a smaller implantation depth (2.2 [interquartile range, 1.0-3.5] mm versus 4.3 [interquartile range, 3.3-5.4] mm; P<0.001) and lower 30-day PPI rates (7.0% versus 14.2%; P=0.035). Compared with the cusp overlap without ICE group, the cusp overlap with ICE group had lower 30-day PPI rates (0.9%; P=0.014), albeit with comparable implantation depths (1.9 [interquartile range, 0.9-2.9] mm; P=0.150). Multivariable analysis showed that our novel method using ICE with the cusp-overlap view was independently associated with a 30-day PPI rate reduction. There were no group differences in 30-day all-cause mortality (1.4% versus 1.6% versus 0%; P=0.608). CONCLUSIONS: Our novel implantation method using transjugular ICE, which enable real-time direct visualization of the membranous septum, achieved a predictably high position of prostheses, resulting in a substantial reduction of conduction disturbances requiring PPI after transcatheter aortic valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Ecocardiografía
8.
JACC Asia ; 4(1): 25-39, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38222260

RESUMEN

Background: In the Asian cohort, data are limited on the risk for coronary obstruction due to sinus of Valsalva (SOV) sequestration in redo transcatheter aortic valve replacement (TAVR) procedures. Objectives: The aim of this study was to assess the potential risk for coronary obstruction in simulated redo TAVR in Asian patients. Methods: Post-TAVR computed tomographic data from 788 patients who received balloon-expandable (BE) SAPIEN 3 transcatheter aortic valves (TAVs) and 334 patients who received self-expanding (SE) Evolut R or Evolut PRO TAVs were analyzed. The risk for coronary obstruction due to SOV sequestration in redo TAVR, defined as the TAV commissure level above the sinotubular junction (STJ) and a TAV-to-STJ distance <2.0 mm in each coronary sinus, was retrospectively evaluated. Results: The potential risks for coronary obstruction due to SOV sequestration at 1 or both coronary arteries were identified in 52.1% of the BE TAV group and 71.3% of the SE TAV group (P < 0.001). After adjusting for multiple covariates, STJ diameter, STJ height, TAV oversizing degree by area, and implantation depth were independently associated with SOV sequestration risk in the BE TAV group, whereas STJ diameter and implantation depth were independently associated with SOV sequestration risk in the SE TAV group. Conclusions: Coronary obstruction due to SOV sequestration in redo TAVR may occur in a substantial number of Asian patients. This finding suggests the importance of considering the structural feasibility of future redo TAVR when implanting the first TAV, especially in Asian patients with long life expectancy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA