1.
Eur J Nucl Med Mol Imaging ; 50(3): 652-660, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36178535

RESUMEN

PURPOSE: Total body positron emission tomography (TB-PET) has recently been introduced in nuclear medicine departments. There is a large interest in these systems, but for many centers, the high acquisition cost makes it very difficult to justify their current operational budget. Here, we propose medium-cost long axial FOV scanners as an alternative. METHODS: Several medium-cost long axial FOV designs are described with their advantages and drawbacks. We describe their potential for higher throughput, more cost-effective scanning, a larger group of indications, and novel research opportunities. The wider spread of TB-PET can also lead to the fast introduction of new tracers (at a low dose), new methodologies, and optimized workflows. CONCLUSIONS: A medium-cost TB-PET would be positioned between the current standard PET-CT and the full TB-PET systems in investment but recapitulate most advantages of full TB-PET. These systems could be more easily justified financially in a standard academic or large private nuclear medicine department and still have ample research options.


Asunto(s)
Medicina Nuclear , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Medicina Nuclear/métodos , Tomografía de Emisión de Positrones/métodos
2.
EJNMMI Phys ; 11(1): 79, 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39331199

RESUMEN

BACKGROUND: [18F]MK-6240 is a neurofibrillary tangles PET radiotracer that has been broadly used in aging and Alzheimer's disease (AD) studies. Majority of [18F]MK-6240 PET studies use dynamic acquisitions longer than 60 min to assess the tracer kinetic parameters. As of today, no consensus has been established on the optimum dynamic PET scan time. In this study, we assess the reproducibility of [18F]MK-6240 quantitative metrics using shortest dynamic PET protocols in cognitively normal subjects. PET metrics were measured through two-tissue compartment model (2TCM) and Logan model to estimate VT and DVR, as well as SUVR from 90 to 120 min (SUVR90 - 120 min) post-tracer injection for brain regions. 2TCM was carried out using the 120 min dynamic coffee break dataset (first scan from 0 to 60 min p.i., second scan from 90 to 120 min p.i.) and then repeated after stepwise shortening it by 5 min. The dynamic scan length that reproduced the 120 min dynamic scans-based VT to within 10% error was defined as the shortest acquisition time (SAT). The SAT SUVR90 - 120 min was deduced from the SAT dataset by extrapolation of each image pixel time-activity curve to 120 min. The reproducibility of the 120 min dynamic scans-based VT2TCM, DVR2TCM, DVRLogan, and SUVR using the SAT was assessed using Passing-Bablock analysis. The limits of reproducibility of each PET metrics were determined using Bland-Altman analysis. RESULTS: A dynamic SAT of 40 min yielded < 10% error in [18F]MK-6240 VT2TCM's for all brain regions, compared to those measured using the 120 min datasets. SAT-based analysis did not show statistically significant systemic or proportional biases in VT2TCM, DVR2TCM, DVRLogan, or SUVR compared to those deduced from the full dynamic dataset of 120 min. A mean difference between the 120 min- and SAT-based analysis of less than 4%, 10%, 15%, and 20% existed in the VT2TCM, DVR2TCM, DVRLogan, and SUVR respectively. CONCLUSION: Kinetic modeling of [18F]MK-6240 PET can be accurately performed using dynamic scan times as short as 40 min. This can facilitate studies with [18F]MK-6240 PET and improve patients accrual. Further work would be necessary to confirm the reproducibility of these results for patients in dementia spectra.

3.
Eur J Radiol ; 181: 111791, 2024 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-39423781

RESUMEN

OBJECTIVE: Our purpose was to describe our initial institutional experience using dedicated brain [18F]-Fluoroestradiol (FES) PET/CT or PET/MRI in the management of patients with estrogen-receptor-positive (ER+) breast cancer brain metastases (BCBM), and compare to [18F]-Fluorodeoxyglucose (FDG) PET and MRI. MATERIALS & METHODS: Patients with biopsy-proven ER+ disease and MRI findings of suspected new, progressive, or recurrent BCBM were included in this retrospective study. Clinical and demographic data were collected. Dedicated brain FES PET/CT or PET/MRI was performed for clinical purposes. Maximum standardized uptake value (SUV) in MRI-defined target lesions and SUV ratio (SUVR, referencing normal-appearing parenchyma) were obtained. Pathology and/or clinical and MRI follow-up data were used as gold standard to classify viable neoplasm versus post-radiotherapy (RT) sequelae. Mann-Whitney tests were performed to compare subgroups. RESULTS: Seven patients met inclusion criteria. 15/16 (94 %) lesions classified as neoplasm were FES-positive. 4/4 (100 %) lesions classified as RT sequelae were FES-negative. Median tumor FES-SUVR were higher than median RT-sequelae FES-SUVR (6.0 (2.8-9.1) versus 0.5 (0.3-0.7), p < 0.01), and similarly, median tumor FES-SUV were higher than median RT-sequelae FES-SUV (4.8 (2.8-9.1) versus 0.6 (0.3-0.8), p < 0.01). Lesion-based analysis of FDG-SUV and -SUVR demonstrated a trend for higher FDG avidity in lesions characterized as neoplasm; however, this did not reach statistical significance. CONCLUSION: Dedicated FES brain PET represents a promising adjunct modality, noting limitations of small sample size, retrospective nature of our study, and the possibility of ER expression heterogeneity. Our findings merit future prospective clinical trials incorporating dedicated brain FES PET/CT and PET/MRI in the management of patients with ER-positive disease and BCBM.

4.
Acta Radiol ; 53(8): 893-9, 2012 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22961644

RESUMEN

BACKGROUND: Radiofrequency ablation (RFA) is a potential application as a salvage tool after failure of surgery, chemotherapy, or radiotherapy of non-small cell lung cancer (NSCLC). Although several studies have evaluated the use of RFA in primary NSCLC, there is little literature on its potential application as a salvage tool. PURPOSE: To evaluate CT-guided RFA employed as a salvage therapy for pulmonary recurrences of NSCLC after prior treatment with chemotherapy, radiation therapy, and/or surgery. MATERIAL AND METHODS: A retrospective computer database search yielded 33 patients with biopsy proven primary NSCLC who underwent CT-guided RFA of 39 recurrent tumors following surgery, chemotherapy, and/or radiotherapy. Follow-up imaging was performed with CT and PET-CT. The endpoints of interest were progression-free survival (PFS) and time to local progression (TTLP). PFS and TTLP were compared by lesion size (<3 cm, ≥3 cm). RESULTS: The median PFS was 8 months. For patients with a tumor size <3 cm median PFS was 11 months, whereas the median PFS of patients with a tumor size ≥3 cm was 5 months. The difference did not reach statistical significance (P = 0.09). The median TTLP of all tumors was 14 months. TTLP of ablated tumors <3 cm in size was 24 months, compared to 8 months for ablated tumors ≥3 cm in size. The difference did not reach statistical significance (P = 0.07). CONCLUSION: RFA of recurrent NSCLC may be a valuable salvage tool to achieve local tumor control, especially in tumors measuring <3 cm in size.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/cirugía , Ablación por Catéter , Neoplasias Pulmonares/cirugía , Recurrencia Local de Neoplasia/cirugía , Cirugía Asistida por Computador , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/mortalidad , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/mortalidad , Estudios Retrospectivos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Phys Med Biol ; 67(10)2022 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-35472757

RESUMEN

Objective.Using Monte-Carlo simulations, we evaluated the physical performance of a hypothetical state-of-the-art clinical PET scanner with adaptive axial field-of-view (AFOV) based on the validated GATE model of the Siemens Biograph VisionTMPET/CT scanner.Approach.Vision consists of 16 compact PET rings, each consisting of 152 mini-blocks of 5 × 5 Lutetium Oxyorthosilicate crystals (3.2 × 3.2 × 20 mm3). The Vision 25.6 cm AFOV was extended by adopting (i) a sparse mini-block ring (SBR) configuration of 49.6 cm AFOV, with all mini-block rings interleaved with 16 mm axial gaps, or (ii) a sparse mini-block checkerboard (SCB) configuration of 51.2 cm AFOV, with all mini-blocks interleaved with gaps of 16 mm (transaxial) × 16 mm (axial) width in checkerboard pattern. For sparse configurations, a 'limited' continuous bed motion (limited-CBM) acquisition was employed to extend AFOVs by 2.9 cm. Spatial resolution, sensitivity, image quality (IQ), NECR and scatter fraction were assessed per NEMA NU2-2012.Main Results.All IQ phantom spheres were distinguishable with all configurations. SBR and SCB percent contrast recovery (% CR) and background variability (% BV) were similar (p-value > 0.05). Compared to Vision, SBR and SCB %CRs were similar (p-values > 0.05). However, SBR and SCB %BVs were deteriorated by 30% and 26% respectively (p-values < 0.05). SBR, SCB and Vision exhibited system sensitivities of 16.6, 16.8, and 15.8 kcps MBq-1, NECRs of 311 kcps @35 kBq cc-1, 266 kcps @25.8 kBq cc-1, and 260 kcps @27.8 kBq cc-1, and scatter fractions of 31.2%, 32.4%, and 32.6%, respectively. SBR and SCB exhibited a smoother sensitivity reduction and noise enhancement rate from AFOV center to its edges. SBR and SCB attained comparable spatial resolution in all directions (p-value > 0.05), yet, up to 1.5 mm worse than Vision (p-values < 0.05).Significance.The proposed sparse configurations may offer a clinically adoptable solution for cost-effective adaptive AFOV PET with either highly-sensitive or long-AFOV acquisitions.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Método de Montecarlo , Fantasmas de Imagen , Rendimiento Físico Funcional , Tomografía de Emisión de Positrones/métodos
6.
Technol Cancer Res Treat ; 21: 15330338221086396, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35341409

RESUMEN

Objectives: This study aims to assess the value of FLT-PET as a non-invasive tool to differentiate between patients with ET and Pre-PMF. This study is a pilot study to have a proof of concept only. Methods: This is a prospective, interventional study where a total of 12 patients were included. Each patient underwent FLT PET imaging as well as bone marrow examination (gold standard). In addition, semi-quantitative (SUVmax and SUVmean) measurements of FLT uptake in the liver, spleen, and Lspine, SUVmean, as well as the Total Lesion Glycolysis (TLG) of the Lspine were performed. Results from the two patient cohorts were compared using = Kruskal-Wallis statistical test. A P-value of <.05 is considered to be statistically significant. Results: The differences in FLT SUVmax and SUVmean measurements in the three organs (liver, spleen, and LSpine) between the ET and Pre-PMF patients were not statistically significant (P > .05). In contrast, TLG measurements in the LSpine were statistically different (P = .013), and therefore, compared to gold standard bone marrow results, TLG can separate ET and Pre-PMF patients. Conclusion: This study is a proof of concept about the potential to discriminate between ET and pre-PMF patients in a non-invasive way. TLG of the LSpine in FLT PET images is a potential quantitative parameter to distinguish between ET and pre-PMF patients.


Asunto(s)
Mielofibrosis Primaria , Trombocitemia Esencial , Médula Ósea/diagnóstico por imagen , Médula Ósea/patología , Didesoxinucleósidos , Humanos , Proyectos Piloto , Tomografía de Emisión de Positrones , Mielofibrosis Primaria/diagnóstico por imagen , Mielofibrosis Primaria/patología , Estudios Prospectivos , Trombocitemia Esencial/diagnóstico por imagen , Trombocitemia Esencial/patología
7.
EJNMMI Res ; 11(1): 38, 2021 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-33855685

RESUMEN

PURPOSE: Glycolysis is increased by hypoxia, suggesting a possible correlation between the accumulation of 2-[18F]fluoro-2-deoxy-D-glucose (FDG) in malignant tumors and regional hypoxia defined by 1H-1-(3-[18F]fluoro-2-hydroxypropyl)-2-nitroimidazole (FMISO) PET. The aim of this study is to investigate the intra-tumoral spatial distribution and quantitative relationship between FDG and FMISO in a cohort of head and neck squamous cell cancer (HNSCC) patients. METHODS: Twenty HNSCC patients with 20 primary tumors and 19 metastatic lymph nodes (LNs) underwent FDG and FMISO PET within 1 week. The metabolic target volume (MTV) was defined on the FDG PET images using a region growing algorithm. The hypoxic volume (HV) was defined by the volume of voxels in an FMISO image within the MTV that satisfy a tumor-to-blood ratio (T/B) greater than 1.2. FDG and FMISO lesions were co-registered, and a voxel-by-voxel correlation between the two datasets was performed. FDG and FMISO TVs' SUVs were also compared as well as the intra-tumoral homogeneity of the two radiotracers. Separate analysis was performed for the primary tumors and LNs. RESULTS: Twenty-six percent of the primary tumors and 15% of LNs showed a strong correlation (R > 0.7) between FDG and FMISO intra-tumor distributions when considering the MTV. For the HV, only 19% of primary tumors and 12% of LN were strongly correlated. A weak and moderate correlation existed between the two markers SUVavg, and SUVmax in the case of the primary tumors, respectively. However, this was not the case for the LNs. Good concordances were also observed between the primary tumor's and LNs HV SUVavgs as well as between the corresponding hypoxic fractions (HF's). CONCLUSIONS: A moderate correlation between FDG and hypoxia radiotracer distribution, as measured by FMISO, seems to exist for primary tumors. However, discordant results were found in the case of LNs. Hypoxia appears to be the dominant driver of high FDG uptake in selected tumors only, and therefore FDG PET images cannot be used as a universal surrogate to identify or predict intra-tumor hypoxia.

8.
EJNMMI Phys ; 8(1): 39, 2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33914185

RESUMEN

INTRODUCTION: Quantitative positron emission tomography (PET) studies of neurodegenerative diseases typically require the measurement of arterial input functions (AIF), an invasive and risky procedure. This study aims to assess the reproducibility of [11C]DPA-713 PET kinetic analysis using population-based input function (PBIF). The final goal is to possibly eliminate the need for AIF. MATERIALS AND METHODS: Eighteen subjects including six healthy volunteers (HV) and twelve Parkinson disease (PD) subjects from two [11C]-DPA-713 PET studies were included. Each subject underwent 90 min of dynamic PET imaging. Five healthy volunteers underwent a test-retest scan within the same day to assess the repeatability of the kinetic parameters. Kinetic modeling was carried out using the Logan total volume of distribution (VT) model. For each data set, kinetic analysis was performed using a patient-specific AIF (PSAIF, ground-truth standard) and then repeated using the PBIF. PBIF was generated using the leave-one-out method for each subject from the remaining 17 subjects and after normalizing the PSAIFs by 3 techniques: (a) Weightsubject×DoseInjected, (b) area under AIF curve (AUC), and (c) Weightsubject×AUC. The variability in the VT measured with PSAIF, in the test-retest study, was determined for selected brain regions (white matter, cerebellum, thalamus, caudate, putamen, pallidum, brainstem, hippocampus, and amygdala) using the Bland-Altman analysis and for each of the 3 normalization techniques. Similarly, for all subjects, the variabilities due to the use of PBIF were assessed. RESULTS: Bland-Altman analysis showed systematic bias between test and retest studies. The corresponding mean bias and 95% limits of agreement (LOA) for the studied brain regions were 30% and ± 70%. Comparing PBIF- and PSAIF-based VT estimate for all subjects and all brain regions, a significant difference between the results generated by the three normalization techniques existed for all brain structures except for the brainstem (P-value = 0.095). The mean % difference and 95% LOA is -10% and ±45% for Weightsubject×DoseInjected; +8% and ±50% for AUC; and +2% and ± 38% for Weightsubject×AUC. In all cases, normalizing by Weightsubject×AUC yielded the smallest % bias and variability (% bias = ±2%; LOA = ±38% for all brain regions). Estimating the reproducibility of PBIF-kinetics to PSAIF based on disease groups (HV/PD) and genotype (MAB/HAB), the average VT values for all regions obtained from PBIF is insignificantly higher than PSAIF (%difference = 4.53%, P-value = 0.73 for HAB; and %difference = 0.73%, P-value = 0.96 for MAB). PBIF also tends to overestimate the difference between PD and HV for HAB (% difference = 32.33% versus 13.28%) and underestimate it in MAB (%difference = 6.84% versus 20.92%). CONCLUSIONS: PSAIF kinetic results are reproducible with PBIF, with variability in VT within that obtained for the test-retest studies. Therefore, VT assessed using PBIF-based kinetic modeling is clinically feasible and can be an alternative to PSAIF.

9.
Med Phys ; 47(4): 1949-1957, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31985827

RESUMEN

PURPOSE: There is a growing interest in extending the axial fields-of-view (AFOV) of PET scanners. One major limitation for the widespread clinical adoption of such systems is the multifold increase in the associated material costs. In this study, we propose a cost-effective solution to extend the PET AFOV using a sparse detector rings configuration. The corresponding physical performance was validated using Monte Carlo simulations. METHODS: Monte Carlo model of the Siemens BiographTM mCT PET/CT, with a 21.8 cm AFOV and a set of compact rings of LSO crystals was developed as a gold standard. The mCT configuration was then modified by interleaving the LSO crystals in the axial direction within each detector block with 4 mm physical gaps (equivalent to the LSO crystal axial dimension) thus extending the AFOV to 43.6 cm (Ex-mCT). The physical performances of the two MC models were assessed and then compared using NEMA NU 2-2007 standards. RESULTS: Ex-mCT showed <0.2 mm difference in transaxial spatial resolution, and, 0.8 mm and 0.3 mm deterioration in axial spatial resolution, compared to the mCT, at 1 and 10 cm off-center of the transaxial field-of-view respectively. The system sensitivities for the mCT and Ex-mCT models were 9.4 ± 0.2 and 10.75 ± 0.2 cps/kBq respectively. The higher sensitivity of Ex-mCT was due to four additional detector rings required to double the mCT AFOV. PET images of the NEMA Image Quality (IQ) phantom showed no artifacts due to detector rings sparsity, and all spheres were visible in both configurations. Ex-mCT achieved percent contrast recoveries within 5.6% of those of the mCT for all spheres and a maximum of 36% higher background variability at the center of the AFOV. The Ex-mCT, however, showed a more uniform noise distribution over an axial range of almost twice the length of the mCT AFOV. CONCLUSIONS: Using the proposed sparse detector-ring configuration, the AFOV of current generation PET systems can be doubled while maintaining the original number and volume of detector crystal elements, and without jeopardizing the system's overall physical performance. Despite an increase in the noise level, the Ex-mCT exhibited an improved noise uniformity.


Asunto(s)
Método de Montecarlo , Tomografía de Emisión de Positrones/instrumentación , Relación Señal-Ruido
10.
Medicine (Baltimore) ; 99(45): e23088, 2020 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-33157979

RESUMEN

The objectives of this research project are to study in patients with primary myelofibrosis (PMF) and Essential Thrombocythemia (ET); (1) the uptake patterns of FLT-PET (FLT-PET) and its value in diagnosing, staging, and treatment response monitoring of malignant hematopoiesis, (2) compare imaging findings from FLT-PET with bone marrow biopsy (standard of care), and (3) associate FLT-PET uptake patterns with genetic makeup such as JAK2 (Janus kinase 2), CALR (Calreticulin), MPL (myeloproliferative leukemia protein), Triple negative disease, and allele burden.This trial is registered in ClinicalTrials.gov with number NCT03116542. Protocol version: Mar 2017.


Asunto(s)
Didesoxinucleósidos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Mielofibrosis Primaria/diagnóstico por imagen , Trombocitemia Esencial/diagnóstico por imagen , Ensayos Clínicos Fase I como Asunto , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
11.
Clin Imaging ; 68: 283-290, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32919154

RESUMEN

OBJECTIVE: (1) Assess the feasibility of 13 N-ammonia cardiac PET (13 N-ammonia-PET) imaging in radiotherapy (RT) treatment position in locally-advanced breast cancer (LABC) patients. (2) Correlate pre-/post-RT changes in myocardial flow reserve (MFR) with the corresponding radiation heart dose. METHODS: Ten left-sided LABC patients undergoing Volumetric Modulated-Arc-Therapy (VMAT) to chest wall and regional lymph nodes underwent a rest/stress 13 N-ammonia-PET at baseline and (median) 13 months post-RT. Changes in cardiac functions and coronary artery Ca2+ scoring between baseline and follow-up were correlated with average RT dose to the myocardium,3 coronary territories, and 17 myocardial segments. RESULTS: Eight (of 10) patients successfully completed the study. The average rest (stress) global MBF (ml.g-1.min-1) for baseline (follow-up) were 0.83 ± 0.25 (2.4 ± 0.79) and 0.92 ± 0.30 (2.76 ± 0.71), respectively. Differences in MBF, heart rate, blood pressure, and rate-pressure product (RPP) between baseline and follow-up were insignificant (P > 0.1).Strong (R = 0.79; P < 0.01) and moderate (R = 0.53; P = 0.37) correlation existed between MBF Rest and MBF Stress, and RPP respectively. Four patients showed a reduction in MFR of up to ~41% in follow-up studies, increasing to ~52% in myocardial segments close to high-radiation isodose lines in 5/8 patients. Agatston Ca + 2 scoring were zero in both baseline and follow-up in six patients; two patients exhibited mild increase in Ca + 2 on follow-ups (range:10-20).Rest and stress LVEF's were normal (>50) for all patients in both studies. CONCLUSION: The feasibility of 13 N-ammonia-PET imaging in treatment position of LABC patients was demonstrated. MFR at 1-year post-irradiation of the heart decreased in 50% of the patients. MFR may be a potential index for early detection of cardiotoxicity in BC patients receiving RT to the chest wall.


Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Amoníaco , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Cardiotoxicidad/diagnóstico por imagen , Circulación Coronaria , Humanos , Proyectos Piloto , Tomografía de Emisión de Positrones
12.
Med Phys ; 36(10): 4400-8, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19928070

RESUMEN

PURPOSE: Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tracer uptake in two sequential images and hypothesized that variation in acute hypoxia may be the cause. In this study, they develop an iterative optimization method to delineate chronic and acute hypoxia based on the 18F-FMISO PET serial images. METHODS: They assume that (1) chronic hypoxia is the same in the two scans and can be represented by a Gaussian distribution, while (2) acute hypoxia varies in the two scans and can be represented by Poisson distributions. For validation, they used Monte Carlo simulations to generate pairs of 18F-FMISO PET images with known proportion of chronic and acute hypoxia and then applied the optimization method to the simulated serial images, yielding excellent fit between the input and the fitted results. They then applied this method to the serial 18F-FMISO PET images of 14 patients with head and neck cancers. RESULTS: The results show good fit of the chronic hypoxia to Gaussian distributions for 13 out of 14 patients (with R2>0.7). Similarly, acute hypoxia appears to be well described by the Poisson distribution (R2>0.7) with three exceptions. The model calculation yielded the amount of acute hypoxia, which differed among the patients, ranging from approximately 13% to 52%, with an average of approximately 34%. CONCLUSIONS: This is the first effort to separate acute and chronic hypoxia from serial PET images of cancer patients.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/metabolismo , Interpretación de Imagen Asistida por Computador/métodos , Misonidazol/análogos & derivados , Modelos Biológicos , Oxígeno/metabolismo , Técnica de Sustracción , Enfermedad Aguda , Algoritmos , Hipoxia de la Célula , Enfermedad Crónica , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Masculino , Misonidazol/farmacocinética , Cintigrafía , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Phys Med Biol ; 54(10): 3083-99, 2009 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-19420418

RESUMEN

This paper systematically evaluates a pharmacokinetic compartmental model for identifying tumor hypoxia using dynamic positron emission tomography (PET) imaging with 18F-fluoromisonidazole (FMISO). A generic irreversible one-plasma two-tissue compartmental model was used. A dynamic PET image dataset was simulated with three tumor regions-normoxic, hypoxic and necrotic-embedded in a normal-tissue background, and with an image-based arterial input function. Each voxelized tissue's time activity curve (TAC) was simulated with typical values of kinetic parameters, as deduced from FMISO-PET data from nine head-and-neck cancer patients. The dynamic dataset was first produced without any statistical noise to ensure that correct kinetic parameters were reproducible. Next, to investigate the stability of kinetic parameter estimation in the presence of noise, 1000 noisy samples of the dynamic dataset were generated, from which 1000 noisy estimates of kinetic parameters were calculated and used to estimate the sample mean and covariance matrix. It is found that a more peaked input function gave less variation in various kinetic parameters, and the variation of kinetic parameters could also be reduced by two region-of-interest averaging techniques. To further investigate how bias in the arterial input function affected the kinetic parameter estimation, a shift error was introduced in the peak amplitude and peak location of the input TAC, and the bias of various kinetic parameters calculated. In summary, mathematical phantom studies have been used to determine the statistical accuracy and precision of model-based kinetic analysis, which helps to validate this analysis and provides guidance in planning clinical dynamic FMISO-PET studies.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Misonidazol/análogos & derivados , Modelos Biológicos , Neoplasias/metabolismo , Consumo de Oxígeno , Oxígeno/metabolismo , Tomografía de Emisión de Positrones/métodos , Algoritmos , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Misonidazol/farmacocinética , Neoplasias/diagnóstico por imagen , Oxígeno/análisis , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Int J Radiat Oncol Biol Phys ; 70(1): 235-42, 2008 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18086391

RESUMEN

PURPOSE: Hypoxia is one of the main causes of the failure to achieve local control using radiotherapy. This is due to the increased radioresistance of hypoxic cells. (18)F-fluoromisonidazole ((18)F-FMISO) positron emission tomography (PET) is a noninvasive imaging technique that can assist in the identification of intratumor regions of hypoxia. The aim of this study was to evaluate the reproducibility of (18)F-FMISO intratumor distribution using two pretreatment PET scans. METHODS AND MATERIALS: We enrolled 20 head and neck cancer patients in this study. Of these, 6 were excluded from the analysis for technical reasons. All patients underwent an (18)F-fluorodeoxyglucose study, followed by two (18)F-FMISO studies 3 days apart. The hypoxic volumes were delineated according to a tumor/blood ratio >or=1.2. The (18)F-FMISO tracer distributions from the two (18)F-FMISO studies were co-registered on a voxel-by-voxel basis using the computed tomography images from the PET/computed tomography examinations. A correlation between the (18)F-FMISO intensities of the corresponding spatial voxels was derived. RESULTS: A voxel-by-voxel analysis of the (18)F-FMISO distributions in the entire tumor volume showed a strong correlation in 71% of the patients. Restraining the correlation to putatively hypoxic zones reduced the number of patients exhibiting a strong correlation to 46%. CONCLUSION: Variability in spatial uptake can occur between repeat (18)F-FMISO PET scans in patients with head and neck cancer. Blood data for one patient was not available. Of 13 patients, 6 had well-correlated intratumor distributions of (18)F-FMISO-suggestive of chronic hypoxia. More work is required to identify the underlying causes of changes in intratumor distribution before single-time-point (18)F-FMISO PET images can be used as the basis of hypoxia-targeting intensity-modulated radiotherapy.


Asunto(s)
Hipoxia de la Célula/fisiología , Neoplasias de Cabeza y Cuello/metabolismo , Misonidazol/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Fármacos Sensibilizantes a Radiaciones/farmacocinética , Anciano , Fluorodesoxiglucosa F18/farmacocinética , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Misonidazol/farmacocinética , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
15.
Semin Nucl Med ; 38(3): 167-76, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18396177

RESUMEN

The development of positron emission tomography/computed tomography (PET/CT) scanners has allowed not only straightforward but also synergistic fusion of anatomical and functional information. Combined PET/CT imaging yields an increased sensitivity and specificity beyond that which either of the 2 modalities possesses separately and therefore provides improved diagnostic accuracy. Because attenuation correction in PET is performed with the use of CT images, with CT used in the localization of disease, accurate spatial registration of PET and CT image sets is required. Correcting for the spatial mismatch caused by respiratory motion represents a particular challenge for the requisite registration accuracy as a result of differences in temporal resolution between the 2 modalities. This review provides a brief summary of the materials, methods, and results involved in multiple investigations of the correction for respiratory motion in PET/CT imaging of the thorax, with the goal of improving image quality and quantitation. Although some schemes use respiratory-phase data selection to exclude motion artifacts, others have adopted sophisticated software techniques. The various image artifacts associated with breathing motion are also described.


Asunto(s)
Artefactos , Tomografía de Emisión de Positrones/tendencias , Técnica de Sustracción , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/tendencias , Humanos , Procesamiento de Imagen Asistido por Computador/tendencias , Movimiento (Física) , Mecánica Respiratoria , Sensibilidad y Especificidad
16.
Clin Imaging ; 49: 121-127, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29414505

RESUMEN

PURPOSE: To assess the inter-operator variability in compartment analysis (CA) of dynamic-FMISO (dyn-FMISO) PET. METHODS: Study-I: Five investigators conducted CA for 23 NSCLC dyn-FMISO tumor time-activity-curves. Study-II: Four operators performed CA for four NSCLC dyn-FMISO datasets. Repeatability of Kinetic-Rate-Constants (KRCs) was assessed. RESULTS: Study-I: Strong correlation (ICC > 0.9) and interchangeable results among operators existed for all KRCs. Study-II: Up to 103% variability in tumor segmentation, and weaker ICC in KRCs (ICC-VB = 0.53; ICC-K1 = 0.91; ICC-K1/k2 = 0.25; ICC-k3 = 0.32; ICC-Ki = 0.54) existed. All KRCs were repeatable among the different operators. CONCLUSIONS: Inter-operator variability in CA of dyn-FMISO was shown to be within statistical errors.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Misonidazol/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Humanos , Misonidazol/farmacocinética
17.
J Nucl Med ; 48(5): 712-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17475958

RESUMEN

UNLABELLED: Respiratory motion during PET/CT acquisition can cause misregistration and inaccuracies in calculation of standardized uptake values (SUVs). Our aim was to compare the detection and characterization of thoracic lesions on PET/CT with and without a deep-inspiration protocol. METHODS: We studied 15 patients with suspected pulmonary lesions who underwent clinical PET/CT, followed by deep-inspiration breath-hold (BH) PET/CT. In BH CT, the whole chest of the patient was scanned in 15 s at the end of deep inspiration. For BH PET, patients were asked to hold their breath 9 times for 20-s intervals. One radiologist reviewed images, aiming to detect and characterize pulmonary, nodal, and skeletal abnormalities. Clinical CT and BH CT were compared for number, size, and location of lesions. Lesion SUVs were compared between clinical PET and BH PET. Images were also visually assessed for accuracy of fusion and registration. RESULTS: All patients had lesions on clinical CT and BH CT. Pulmonary BH CT detected more lesions than clinical CT in 13 of 15 patients (86.7%). The total number of lung lesions detected increased from 53 with clinical CT to 82 with BH CT (P<0.001). Eleven patients showed a total of 31 lesions with abnormal (18)F-FDG uptake. BH PET/CT had the advantage of reducing misregistration and permitted a better localization of sites with (18)F-FDG uptake. A higher SUV was noted in 22 of 31 lesions on BH PET compared with clinical PET, with an average increase in SUV of 14%. CONCLUSION: BH PET/CT enabled an increased detection and better characterization of thoracic lesions compared with a standard PET/CT protocol, in addition to more precise localization and quantification of the findings. The technique is easy to implement in clinical practice and requires only a minor increase in the examination time.


Asunto(s)
Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Mecánica Respiratoria , Neoplasias Torácicas/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Femenino , Humanos , Inhalación , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
18.
J Nucl Med ; 48(1): 22-6, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17204695

RESUMEN

UNLABELLED: The goal of this study was to describe our initial experience with the deep-inspiration breath-hold (DIBH) technique in combined PET/CT of the thorax. This article presents particular emphasis on the technical aspects required for clinical implementation. METHODS: In the DIBH technique, the patient is verbally coached and brought to a reproducible deep inspiration breath-hold level. The first "Hold" period, which refers to the CT session, is considered as the reference. This is followed by 9- to 20-s independent breath-hold PET acquisitions. The goal is to correct for respiratory motion artifacts and, consequently, improve the tumor quantitation and localization on the PET/CT images and inflate the lungs for possible improvement in the detection of subcentimeter pulmonary nodules. A physicist monitors and records patient breathing during PET/CT acquisition using a motion tracker. Patient breathing traces obtained during acquisition are examined on the fly to assess the reproducibility of the technique. RESULTS: Data from 8 patients, encompassing 10 lesions, were analyzed. Visual inspection of fused PET/CT images showed improved spatial matching between the 2 modalities, reduced motion artifacts especially in the diaphragm, and increased the measured standardized uptake value (SUV) attributed to reduced motion blurring, as compared with the standard clinical PET/CT images. CONCLUSION: The practice of DIBH PET/CT is feasible in a clinical setting. With this technique, consistent lung inflation levels are achieved during PET/CT sessions, as judged by both motion tracker and verification of spatial matching between PET and CT images. Breathing-induced motion artifacts are significantly reduced using DIBH compared with free breathing, enabling better target localization and quantitation. The DIBH technique showed an increase in the median SUV by 32.46%, with a range from 4% to 83%, compared with SUVs measured on the clinical images. The median percentage reduction in the PET-to-CT lesions' centroids was 26.6% (range, 3%-50%).


Asunto(s)
Neoplasias Pulmonares/radioterapia , Tomografía de Emisión de Positrones/métodos , Respiración , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Torácica/métodos , Planificación de la Radioterapia Asistida por Computador , Tórax/patología , Factores de Tiempo
19.
Med Phys ; 34(6): 2039-47, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17654907

RESUMEN

Our previous patient studies have shown that the use of respiration averaged computed tomography (ACT) for attenuation correction of the positron emission tomography (PET) data from PET/CT reduces the potential misalignment in the thorax region by matching the temporal resolution of the CT to that of the PET. In the present work, we investigated other approaches of acquiring ACT in order to reduce the CT dose and to improve the ease of clinical implementation. Four-dimensional CT (4DCT) data sets for ten patients (17 lung/esophageal tumors) were acquired in the thoracic region immediately after the routine PET/CT scan. For each patient, multiple sets of ACTs were generated based on both phase image averaging (phase approach) and fixed cine duration image averaging (cine approach). In the phase approach, the ACTs were calculated from CT images corresponding to the significant phases of the respiratory cycle: ACT(050phs) from end-inspiration (0%) and end-expiration (50%), ACT(2070phs) from mid-inspiration (20%) and mid-expiration (70%), ACT(4phs) from 0%, 20%, 50% and 70%, and ACT(10phs) from all ten phases, which was the original approach. In the cine approach, which does not require 4DCT, the ACTs were calculated based on the cine images from cine durations of 1 to 6 s at 1 s increments. PET emission data for each patient were attenuation corrected with each of the above mentioned ACTs and the tumor maximum standard uptake value (SUVmax), average SUV (SUVavg), and tumor volume measurements were compared. Percent differences were calculated between PET data corrected with various ACTs and that corrected with ACT(10phs). In the phase approach, the ACT(10phs) can be approximated by the ACT(4phs) to within a mean percent difference of 2% in SUV and tumor volume measurements. In cine approach, ACT(10phs) can be approximated to within a mean percent difference of 3% by ACTs computed from cine durations > or =3 s. Acquiring CT images only at the four significant phases for the ACT can reduce radiation dose to 1/3 of the current 4DCT dose; however, the implementation of this approach requires additional hardware that is not standard equipment on PET/CT scanners. In the cine approach, we recommend a duration of 6 +/- 1 s in order to include variations of respiratory patterns in a larger population. This approach can be easily implemented because cine acquisition mode is available on all GE PET/CT scanners. The CT dose in the cine approach can be reduced to approximately 5 mGy by using the lowest mA setting (10 mA), while still maintaining good quality CT data for PET attenuation correction. In our scanning protocol, the ACT is only acquired if respiration-induced misregistration is observed (determined before the PET scan is completed), and therefore patients do not receive unnecessary CT radiation dose.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones/métodos , Mecánica Respiratoria , Neoplasias Torácicas/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Artefactos , Inteligencia Artificial , Almacenamiento y Recuperación de la Información/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
20.
J Nucl Med ; 58(6): 911-919, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28232611

RESUMEN

Hypoxic tumors exhibit increased resistance to radiation, chemical, and immune therapies. 18F-fluoromisonidazole (18F-FMISO) PET is a noninvasive, quantitative imaging technique used to evaluate the magnitude and spatial distribution of tumor hypoxia. In this study, pharmacokinetic analysis (PKA) of 18F-FMISO dynamic PET extended to 3 h after injection is reported for the first time, to our knowledge, in stage III-IV non-small cell lung cancer (NSCLC) patients. Methods: Sixteen patients diagnosed with NSCLC underwent 2 PET/CT scans (1-3 d apart) before radiation therapy: a 3-min static 18 F-FDG and a dynamic 18F-FMISO scan lasting 168 ± 15 min. The latter data were acquired in 3 serial PET/CT dynamic imaging sessions, registered with each other and analyzed using pharmacokinetic modeling software. PKA was performed using a 2-tissue, 3-compartment irreversible model, and kinetic parameters were estimated for the volumes of interest determined using coregistered 18F-FDG images for both the volume of interest-averaged and the voxelwise time-activity curves for each patient's lesions, normal lung, and muscle. Results: We derived average values of 18F-FMISO kinetic parameters for NSCLC lesions as well as for normal lung and muscle. We also investigated the correlation between the trapping rate (k3) and delivery rate (K1), influx rate (Ki ) constants, and tissue-to-blood activity concentration ratios (TBRs) for all tissues. Lesions had trapping rates 1.6 times larger, on average, than those of normal lung and 4.4 times larger than those in muscle. Additionally, for almost all cases, k3 and Ki had a significant strong correlation for all tissue types. The TBR-k3 correlation was less straightforward, showing a moderate to strong correlation for only 41% of lesions. Finally, K1-k3 voxelwise correlations for tumors were varied, but negative for 76% of lesions, globally exhibiting a weak inverse relationship (average R = -0.23 ± 0.39). However, both normal tissue types exhibited significant positive correlations for more than 60% of patients, with 41% having moderate to strong correlations (R > 0.5). Conclusion: All lesions showed distinct 18F-FMISO uptake. Variable 18F-FMISO delivery was observed across lesions, as indicated by the variable values of the kinetic rate constant K1 Except for 3 cases, some degree of hypoxia was apparent in all lesions based on their nonzero k3 values.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Neoplasias Pulmonares/metabolismo , Misonidazol/análogos & derivados , Modelos Biológicos , Tomografía de Emisión de Positrones/métodos , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Simulación por Computador , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Misonidazol/farmacocinética , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular