Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Med ; 88(2): 860-870, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35348250

RESUMEN

PURPOSE: To examine the time-dependent diffusion of fluorinated (19 F) gas in human lungs for determination of surface-to-volume ratio in comparison to results from hyperpolarized 129 Xe and lung function testing in healthy volunteers and patients with chronic obstructive pulmonary disease. METHODS: Diffusion of fluorinated gas in the short-time regime was measured using multiple gradient-echo sequences with a single pair of trapezoidal gradient pulses. Pulmonary surface-to-volume ratio was calculated using a first-order approximation of the time-dependent diffusion in a study with 20 healthy volunteers and 22 patients with chronic obstructive pulmonary disease. The repeatability after 7 days as well as the correlation with hyperpolarized 129 Xe diffusion MRI and lung function testing was analyzed. RESULTS: Using 19 F diffusion MRI, the median surface-to-volume ratio is significantly decreased in chronic obstructive pulmonary disease patients (S/V = 126 cm-1 [87-144 cm-1 ]) compared with healthy volunteers (S/V = 164 cm-1 [160-84 cm-1 ], p < 0.0001). No significant difference was found between measurements within 7 days for healthy (p = 0.88, median coefficient of variation = 4.3%) and diseased subjects (p = 0.58, median coefficient of variation= 6.7%). Linear correlations were found with S/V from 129 Xe diffusion MRI (r = 0.85, p = 0.001) and the forced expiratory volume in 1 second (r = 0.68, p < 0.0001). CONCLUSION: Examination of lung microstructure using time-dependent diffusion measurement of inhaled 19 F is feasible, repeatable, and correlates with established measurements.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Isótopos de Xenón , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Pruebas de Función Respiratoria
2.
Magn Reson Med ; 84(3): 1336-1346, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32060989

RESUMEN

PURPOSE: To reduce acquisition time and improve image quality and robustness of ventilation assessment in a single breath-hold using 1 H-guided reconstruction of fluorinated gas (19 F) MRI. METHODS: Reconstructions constraining total variation in the image domain, L1 norm in the wavelet domain, and directional total variation between 19 F and 1 H images were compared in order to accelerate 19 F ventilation imaging using retrospectively undersampled data from a healthy volunteer. Using the optimal constrained reconstruction in 8 patients with chronic obstructive pulmonary disease (16-seconds breath-hold), ventilation maps of various acceleration factors (2-fold to 13-fold) were compared with maps of the full data set using the Dice coefficient, difference in volume defect percentage and overlap percentage, as well as hyperpolarized 129 Xe gas MRI. RESULTS: The reconstruction constraining total variation and directional total variation simultaneously performed best in the healthy volunteer (RMS error = 0.07, structural similarity index = 0.77) for a measurement time of 2 seconds. Using the same reconstruction in the patients with chronic obstructive pulmonary disease, the Dice coefficient of defect volumes was 0.86 ± 0.05, the mean difference in volume defect percentage was -1.0 ± 1.7 percentage points, and the overlap percentage was 87% ± 2% for a measurement time of 6 seconds. Between volume defect percentage of 19 F and 129 Xe, a linear correlation (r = 0.75; P = .03) was found, with 19 F volume defect percentage being significantly higher (mean difference = 11%; P = .04). CONCLUSION: 1 H-guided reconstruction of pulmonary 19 F gas MRI enables reduction of acquisition time while maintaining image quality and robustness of functional parameters.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Pulmón , Imagen por Resonancia Magnética , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Respiración , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA