Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Curr Ther Res Clin Exp ; 100: 100738, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38516027

RESUMEN

Background: Belimumab is the first antibody drug approved for systemic lupus erythematosus (SLE), and is a fully human monoclonal antibody that inhibits soluble B lymphocyte stimulator protein. In clinical trials, a composite index was used to assess efficacy of belimumab. However, clinical guidelines on SLE treatment currently use single efficacy indexes. Objective: The main objective of this study was to perform a meta-analysis to evaluate the efficacy of belimumab utilizing single indexes used in routine clinical practice, rather than the composite efficacy index used in clinical trials during the development phase. As a secondary endpoint, safety was also evaluated. Methods: Several databases were searched to identify reports published up to December 1, 2021 on randomized controlled trials examining the efficacy of belimumab in adult patients with SLE. From the clinical trial data, efficacy was evaluated using single indexes including the SLE Disease Activity Index (SLEDAI), British Isles Lupus Assessment Group Index, and Physician Global Assessment. Safety was also assessed. Data were synthesized and analyzed using Review Manager 5.4. This study protocol was registered in the UMIN Clinical Trials Registry (Registration number: UMIN000052846). Results: The search identified 12 reports that met the inclusion criteria. Five reports were included in efficacy evaluation and 9 in safety evaluation. The primary endpoint was SLEDAI. Significantly more belimumab-treated patients achieved a ≥4-point reduction in SLEDAI (relative risk 1.28; 95% confidence interval, 1.16-1.40; P < 0.00001) compared with placebo. Other efficacy endpoints were also improved significantly in the belimumab group. No difference in safety was found between belimumab and placebo. Conclusions: The present meta-analysis evaluating clinical trial data using various single indexes recommended by clinical guidelines for SLE verifies that addition of belimumab to standard of care is efficacious for moderate-to-severe SLE.

2.
Sci Rep ; 14(1): 15045, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951558

RESUMEN

Near-seafloor concentrated gas hydrates (GHs) containing large amounts of methane have been identified at various gas chimney sites. Although understanding the spatial distribution of GHs is fundamental for assessing their dissociation impact on aggravating global warming and resource potential, the spatial distribution of GHs within gas chimneys remains unclear. Here, we estimate the subseafloor distribution of GHs at a gas chimney site in the Japan Sea using marine electrical resistivity tomography data. The resulting two-dimensional subseafloor resistivity structure shows high anomalies (10-100 Ωm) within seismically inferred gas chimneys. As the resistivity anomalies are aligned with high amplitude seismic reflections and core positions recovering GHs, we interpret the resistivity anomalies are near-seafloor concentrated GH deposits. We also detect various distribution patterns of the high resistivity anomalies including 100-m wide and 40-m thick anomaly near the seafloor and 500-m wide anomaly buried 50 m below the seafloor, suggesting that GHs are heterogeneously distributed. Therefore, considering such heterogeneous GH distribution within gas chimneys is critical for in-depth assessments of GH environmental impacts and energy resources.

3.
Clin Transl Sci ; 17(2): e13731, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38564661

RESUMEN

Organic anion-transporting polypeptides (OATP)1B are drug transporters mainly expressed in the sinusoidal membrane. Many studies have suggested that OATP1B activity is affected by genetic factor, the uremic toxin 3-carboxy-4-methyl-5-propyl-2-furanpropanoic acid (CMPF), and inflammatory cytokines, such as tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6). Coproporphyrin-I (CP-I) is spotlighted as a highly accurate endogenous substrate of OATP1B. We previously reported a positive correlation between plasma CMPF and CP-I concentrations in patients with chronic kidney disease (CKD). The present study evaluated the impact of genetic polymorphisms, CMPF, IL-6, TNF-α, and estimated glomerular filtration rate (eGFR) on individual differences in OATP1B activity in patients with CKD. Seventy-three patients with CKD who received kidney transplant at least 3 months earlier were analyzed. Plasma CP-I concentration was higher in OATP1B1*15 carriers than in non-carriers. In all patients, CP-I did not correlate significantly with CMPF, IL-6, TNF-α, or eGFR. However, when the dataset was cut off at CMPF concentration of 8 and 7 µg/mL, 4 µg/mL, 3 µg/mL or 2 µg/mL, CMPF correlated positively with CP-I, and correlation coefficient tended to be higher as plasma CMPF concentration was lower. In conclusion, OATP1B1*15 impacted OATP1B activity in patients with CKD, but IL-6 and TNF-α did not. However, the impact of CMPF on OATP1B activity was limited to low CMPF concentrations, and the effect could be saturated at high concentrations. When prescribing an OATP1B substrate drug for patients with CKD, the OATP1B1*15 carrier status and plasma CMPF concentration may need to be considered to decide the dose regimen.


Asunto(s)
Interleucina-6 , Propionatos , Insuficiencia Renal Crónica , Humanos , Factor de Necrosis Tumoral alfa , Furanos
4.
Clin Biochem ; 124: 110706, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38176645

RESUMEN

OBJECTIVE: Belimumab is a monoclonal antibody against the B-lymphocyte stimulating factor and is approved for the treatment of patients with systemic lupus erythematosus (SLE) not responding adequately to existing therapies. In this study, we established and validated an assay for quantifying belimumab in human plasma. METHODS: From the peptides generated by trypsin digestion of belimumab, in silico analysis was used to search for unique peptides to determine the surrogate peptides. Samples were trypsin digested, pretreated with solid phase extraction, and analyzed by ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) to quantify the surrogate peptide in the samples. The assay was validated according to the Food and Drug Administration (FDA) bioanalytical method validation guidance. We used the established assay to quantify plasma belimumab concentrations in two SLE patients treated with belimumab. RESULTS: Among the unique peptides identified by the in silico analysis, the peptide with the best peak shape when measured by UHPLC-MS/MS was selected as the surrogate peptide. The validation results of this assay met the acceptable criteria recommended by the FDA guidance. The lower limit of quantification (LLOQ) for belimumab was 2 µg/mL. Recovery rates and matrix effects when corrected for internal standards were 91.5-114.3 % and 96.9-108.4 %, respectively. Plasma concentrations of belimumab were measured in 12 samples from two belimumab-treated SLE patients. All concentrations were within the calibration range. CONCLUSIONS: We have established and validated a method for measuring plasma belimumab concentrations using UHPLC/MS-MS. By measuring plasma belimumab concentrations in more patients, this method is expected to contribute to appropriate use of belimumab.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Lupus Eritematoso Sistémico , Espectrometría de Masas en Tándem , Humanos , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Tripsina/uso terapéutico , Péptidos , Lupus Eritematoso Sistémico/tratamiento farmacológico , Reproducibilidad de los Resultados
5.
Pharmacol Res Perspect ; 12(4): e1255, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39096038

RESUMEN

In this study, plasma belimumab concentrations were measured over the course of treatment in systemic lupus erythematosus (SLE) patients on belimumab therapy, and intra- and interindividual variations in plasma belimumab concentration were evaluated. A single-center prospective study was conducted at Oita University Hospital to evaluate trough plasma concentrations over the course of treatment in 13 SLE patients treated with intravenous belimumab. Plasma belimumab concentrations were measured by a validated ultra-high performance liquid chromatography with tandem mass spectrometry method. The median age of the patients was 40 (interquartile range: 35-51) years and the median weight was 51.8 (47.0-58.1) kg. A mean of 9.4 (range: 1-13) blood samples was collected per patient at routine visits. The mean (± SD) plasma belimumab concentration was 33.4 ± 11.9 µg/mL in the patient with the lowest concentration and 170.0 ± 16.6 µg/mL in the patient with the highest concentration, indicating a 5-fold difference between patients. On the other hand, the within-patient coefficient of variation ranged from 7.1% to 35.7%, showing no large variations. No significant correlation was observed between plasma belimumab concentration and belimumab dose (mg/kg) (Spearman's rank correlation coefficient = 0.22, p = .54). Examinations of trough plasma belimumab concentrations over the course of treatment in patients with SLE showed small intraindividual variation but large interindividual variation. Plasma belimumab trough concentration varied widely among patients administered the approved dose.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Inmunosupresores , Lupus Eritematoso Sistémico , Humanos , Lupus Eritematoso Sistémico/tratamiento farmacológico , Lupus Eritematoso Sistémico/sangre , Anticuerpos Monoclonales Humanizados/farmacocinética , Anticuerpos Monoclonales Humanizados/uso terapéutico , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/sangre , Adulto , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Masculino , Inmunosupresores/farmacocinética , Inmunosupresores/sangre , Inmunosupresores/administración & dosificación , Inmunosupresores/uso terapéutico , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión , Monitoreo de Drogas/métodos
6.
Clin Transl Sci ; 17(3): e13768, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38465776

RESUMEN

Plasma 4ß-hydroxycholesterol (OHC) has drawn attention as an endogenous substrate indicating CYP3A activity. Plasma 4ß-OHC is produced by hydroxylation by CYP3A4 and CYP3A5 and by cholesterol autoxidation. Plasma 4α-OHC is produced by cholesterol autoxidation and not affected by CYP3A activity. This study aimed to evaluate the usefulness of plasma 4ß-OHC concentration minus plasma 4α-OHC concentration (4ß-OHC-4α-OHC) compared with plasma 4ß-OHC concentration and 4ß-OHC/total cholesterol (TC) ratio in cross-sectional evaluation of CYP3A activity. Four hundred sixteen general adults were divided into 191 CYP3A5*1 carriers and 225 non-carriers. Twenty-six patients with chronic kidney disease (CKD) with CYP3A5*1 allele were divided into 14 with CKD stage 3 and 12 with stage 4-5D. Area under the receiver operating characteristic curve (AUC) for the three indices were evaluated for predicting presence or absence of CYP3A5*1 allele in general adults, and for predicting CKD stage 3 or stage 4-5D in patients with CKD. There was no significant difference between AUC of 4ß-OHC-4α-OHC and AUC of plasma 4ß-OHC concentration in general adults and in patients with CKD. AUC of 4ß-OHC-4α-OHC was significantly smaller than that of 4ß-OHC/TC ratio in general adults (p = 0.025), but the two indices did not differ in patients with CKD. In conclusion, in the present cross-sectional evaluation of CYP3A activity in general adults and in patients with CKD with CYP3A5*1 allele, the usefulness of 4ß-OHC-4α-OHC was not different from plasma 4ß-OHC concentration or 4ß-OHC/TC ratio. However, because of the limitations in study design and subject selection of this research, these findings require verification in further studies.


Asunto(s)
Hidroxicolesteroles , Insuficiencia Renal Crónica , Adulto , Humanos , Citocromo P-450 CYP3A/genética , Estudios Transversales , Colesterol , Biomarcadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA