Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Neuroradiology ; 64(5): 1011-1020, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35149883

RESUMEN

PURPOSE: Heavily T2-weighted 3D FLAIR (hT2w-3D-FLAIR) sequence with constant flip angle (CFA) has been reported as being more sensitive to low concentrations of gadolinium (Gd) enabling endolymphatic hydrops (EH) visualization. The purpose of this study was to compare signal-to-noise (SNR) ratio, detection rate of EH, and increased perilymphatic enhancement (PE) as well as diagnostic accuracy in diagnosing definite Menière's disease (MD), using 3D-SPACE FLAIR versus conventional 3D-TSE FLAIR. METHODS: This retrospective study included 29 definite MD patients who underwent a 4-h delayed intravenous (IV) Gd-enhanced 3D-TSE FLAIR and 3D-SPACE FLAIR MRI between February 2019 and February 2020. MR images were qualitatively and quantitatively analyzed twice by 2 experienced head and neck radiologists. Qualitative assessment included grading of cochlear and vestibular EH and visual comparison of PE. Quantitative assessment of PE was performed by placing a region of interest (ROI) and ratio calculation in the basal turn of the cochlea and the brainstem. RESULTS: The intra- and inter-reader reliability for grading of EH and PE was excellent (0.7 < kappa < 0.9) for 3D-SPACE FLAIR and exceeded the values for 3D-TSE FLAIR (0.5 < kappa < 0.9) The combination of EH and visual assessment of PE has the highest diagnostic accuracy in diagnosing definite MD on 3D-SPACE FLAIR with a sensitivity of 0.91 and a specificity of 0.98 resulting in a sensitivity raise of 6% compared to 3D-TSE FLAIR. CONCLUSION: Four-hour delayed IV Gd-enhanced 3D-SPACE FLAIR sequence has a higher sensitivity and reproducibility than 3D-TSE FLAIR for the visualization of EH and increased PE in definite MD patients.


Asunto(s)
Hidropesía Endolinfática , Enfermedad de Meniere , Medios de Contraste , Hidropesía Endolinfática/diagnóstico por imagen , Gadolinio , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Enfermedad de Meniere/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
2.
Eur Arch Otorhinolaryngol ; 278(6): 1805-1813, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32761272

RESUMEN

OBJECTIVE: To evaluate early results on hygiene, safety and functional outcome in a population undergoing a canal wall up technique with bony obliteration of the mastoid and epitympanic space (CWU-BOT) for extensive cholesteatoma, performed by a single surgeon. This study compares different techniques of tympanic membrane reconstruction, viz. allografts and autografts. PATIENTS: A consecutive series of 61 ears with acquired cholesteatoma treated with primary or revision CWU-BOT surgery from 2009 to 2014. INTERVENTION: Obliteration was performed by the use of cortical bone-chips and bone pâté. Patients were followed up with micro-otoscopy and MRI with diffusion-weighted imaging. Ossicular reconstruction was performed using a remodelled autologous or allogenic incus or malleus. MAIN OUTCOME MEASURES: Residual and recurrence rate and short- and mid-term hearing outcome prior to any revision tympanoplasty were analysed, the effect of type of tympanic membrane reconstruction was considered. RESULTS: 44 Ears were primary cholesteatoma cases, 17 cases were referred for revision surgery. Mean postoperative follow up was 45 months (SD 18.08) and mean follow-up until the last non-EP DW MRI 42 months (SD 17.72). Recurrent disease was present in 3%, no residual disease was present. An AC gain was seen in 75% of all ears undergoing ossicular reconstruction. CONCLUSION: Reproducible safety, hygiene and hearing results with limited recurrence and residual disease can be obtained by younger otologic surgeons performing the BOT-CWU for extensive cholesteatoma while using a variety of grafts for tympano-ossicular reconstruction. The tympano-ossicular allograft nevertheless shows superior hearing results when a mobile intact stapes is present. LEVEL OF EVIDENCE: Level 4.


Asunto(s)
Colesteatoma del Oído Medio , Timpanoplastia , Aloinjertos , Autoinjertos , Colesteatoma del Oído Medio/cirugía , Audición , Humanos , Higiene , Apófisis Mastoides , Recurrencia Local de Neoplasia , Estudios Retrospectivos , Resultado del Tratamiento , Membrana Timpánica/diagnóstico por imagen , Membrana Timpánica/cirugía
3.
Eur Arch Otorhinolaryngol ; 278(12): 4743-4748, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33609177

RESUMEN

OBJECTIVE: The MO-meatocanalplasty is the oblique modification of the M-meatoplasty. The MO-meatocanalplasty was designed to address the superior quadrants of the meatus and the bony canal without the need for a retro-auricular incision. This retrospective analysis was performed to evaluate the long-term results of the MO-meatocanalplasty in patients with a narrow external auditory canal (EAC) with recurrent otitis externa or in patients unable to wear a hearing aid. METHODS: Twenty-two ears in twenty consecutive patients who received a MO-meatocanalplasty for a narrow EAC with recurrent otitis externa or the inability to wear a hearing aid were analysed retrospectively. There were no patients included with any type of previous or planned second stage tympanoplasty procedures. A follow-up period of 3 years was analysed for postoperative recurrent narrowing, the self-cleaning capacity of the EAC, the recurrence of otitis externa, the inability to wear a hearing aid, change in hearing level and for all types of aesthetical complaints. RESULTS: The MO-meatocanalplasty procedure was effective in 82% (n = 18). Postoperative recurrent narrowing was detected in 9% (n = 2). Insufficient self-cleaning capacity of the EAC was 9.1% (n = 2). The ability to wear a hearing aid was restored in all patients with the need for a hearing aid. No aesthetical complaints were reported. CONCLUSION: The MO-meatocanalplasty is an effective, safe and aesthetical accepted procedure to address the narrow meatus and external auditory canal. With this procedure, there is no need for a retro-auricular incision in order to create a well aerated, dry and self-cleaning EAC in patients with a narrow EAC with recurrent otitis externa or in patient with the inability to wear a hearing aid.


Asunto(s)
Audífonos , Otitis Externa , Conducto Auditivo Externo/cirugía , Humanos , Otitis Externa/cirugía , Estudios Retrospectivos , Timpanoplastia
4.
Eur Arch Otorhinolaryngol ; 278(12): 4783-4793, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33492418

RESUMEN

PURPOSE: In this retrospective study the relationship between cochleovestibular function and a magnetic resonance imaging (MRI-) based classification system of endolymphatic hydrops was investigated. METHODS: Seventy-eight patients with unilateral definite Menière's disease who underwent MRI were included. The parameters of Pure Tone Audiometry (PTA), caloric irrigation test, cervical vestibular evoked myogenic potentials, and video Head Impulse Test were compared between the grades of endolymphatic hydrops (EH) and perilymphatic enhancement (PE) on MRI. RESULTS: The low-frequency PTA was significantly different between cochlear EH grades I and II (p = 0.036; Grade I: mean (Standard Deviation, SD) = 51 decibel Hearing Level (dB HL) (18 dB HL); Grade II: mean (SD) = 60 dB HL (16 dB HL)), and vestibular EH grades 0 and III (p = 0.018; Grade 0: mean (SD) = 43 dB HL (21 dB HL); Grade III: mean = 60 dB HL (10 dB HL)). The ipsilateral caloric sum of ears with vestibular EH grade I (n = 6) was increased with regards to vestibular EH grades 0 (p = 0.001), II (p < 0.001), and III (p < 0.001) (Grade 0: mean (SD) = 24°/s (15°/s); Grade I: mean (SD) = 47°/s (11°/s); Grade II: mean (SD) = 21°/s (13°/s); Grade III: mean (SD) = 16°/s (8°/s)). CONCLUSION: According to these results we can conclude that only the highest grades of cochlear and vestibular EH seem to be associated with decreased cochleovestibular functioning.


Asunto(s)
Hidropesía Endolinfática , Enfermedad de Meniere , Potenciales Vestibulares Miogénicos Evocados , Hidropesía Endolinfática/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Enfermedad de Meniere/diagnóstico por imagen , Estudios Retrospectivos
5.
Genet Med ; 21(5): 1199-1208, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30287925

RESUMEN

PURPOSE: To characterize new molecular factors implicated in a hereditary congenital facial paresis (HCFP) family and otosclerosis. METHODS: We performed exome sequencing in a four-generation family presenting nonprogressive HCFP and mixed hearing loss (HL). MEPE was analyzed using either Sanger sequencing or molecular inversion probes combined with massive parallel sequencing in 89 otosclerosis families, 1604 unrelated affected subjects, and 1538 unscreened controls. RESULTS: Exome sequencing in the HCFP family led to the identification of a rare segregating heterozygous frameshift variant p.(Gln425Lysfs*38) in MEPE. As the HL phenotype in this family resembled otosclerosis, we performed variant burden and variance components analyses in a large otosclerosis cohort and demonstrated that nonsense and frameshift MEPE variants were significantly enriched in affected subjects (p = 0.0006-0.0060). CONCLUSION: MEPE exerts its function in bone homeostasis by two domains, an RGD and an acidic serine aspartate-rich MEPE-associated (ASARM) motif inhibiting respectively bone resorption and mineralization. All variants associated with otosclerosis are predicted to result in nonsense mediated decay or an ASARM-and-RGD-truncated MEPE. The HCFP variant is predicted to produce an ASARM-truncated MEPE with an intact RGD motif. This difference in effect on the protein corresponds with the presumed pathophysiology of both diseases, and provides a plausible molecular explanation for the distinct phenotypic outcome.


Asunto(s)
Proteínas de la Matriz Extracelular/genética , Parálisis Facial/congénito , Glicoproteínas/genética , Otosclerosis/genética , Fosfoproteínas/genética , Adulto , Huesos/metabolismo , Proteínas de la Matriz Extracelular/metabolismo , Parálisis Facial/etiología , Parálisis Facial/genética , Parálisis Facial/metabolismo , Familia , Femenino , Enfermedades Genéticas Ligadas al Cromosoma X/genética , Variación Genética/genética , Glicoproteínas/metabolismo , Pérdida Auditiva/genética , Heterocigoto , Humanos , Masculino , Linaje , Fenotipo , Fosfoproteínas/metabolismo , Secuenciación del Exoma/métodos
6.
Neuroradiology ; 61(4): 421-429, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30719545

RESUMEN

PURPOSE: There is still a clinical-radiologic discrepancy in patients with Menière's disease (MD). Therefore, the purpose of this study was to investigate the reliability of current MRI endolymphatic hydrops (EH) criteria according to Baráth in a larger study population and the clinical utility of new imaging signs such as a supplementary fourth low-grade vestibular EH and the degree of perilymphatic enhancement (PE) in patients with Menière's disease (MD). METHODS: This retrospective study included 148 patients with probable or definite MD according to the 2015 American Academy of Otolaryngology, Head and Neck Surgery criteria who underwent a 4-h delayed intravenous Gd-enhanced 3D-FLAIR MRI between January 2015 and December 2016. Vestibular EH, vestibular PE, cochlear EH, and cochlear PE were reviewed twice by three experienced readers. Cohen's Kappa and multivariate logistic regression were used for analysis. RESULTS: The intra- and inter-reader reliability for the grading of vestibular-cochlear EH and PE was excellent (0.7 < kappa < 0.9). The two most distinctive characteristics to identify MD are cochlear PE and vestibular EH which combined gave a sensitivity and specificity of 79.5 and 93.6%. By addition of a lower grade vestibular EH, the sensitivity improved to 84.6% without losing specificity (92.3%). Cochlear EH nor vestibular PE showed added-value. CONCLUSIONS: MRI using vestibular-cochlear EH and PE grading system is a reliable technique. A four-stage vestibular EH grading system in combination with cochlear PE assessment gives the best diagnostic accuracy to detect MD.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Enfermedad de Meniere/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Masculino , Enfermedad de Meniere/clasificación , Persona de Mediana Edad , Compuestos Organometálicos , Perilinfa/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
7.
Int J Audiol ; 58(5): 296-300, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30636507

RESUMEN

OBJECTIVE: The objective is to evaluate the influence of the presentation rate on intraoperative ECAP thresholds in cochlear implant users. DESIGN: The design was data on the ECAP thresholds (t-NRT) as well as the behavioural T- and C-levels have been collected in CI patients of a quaternary otologic referral centre. Measurements of the tNRT thresholds were performed intraoperatively for 250 Hz and 80 Hz presentation rates and correlated to the stabilised T- and C-levels measured at the 5th fitting session, 4-6 months after surgery. STUDY SAMPLE: There was a study sample of 35 consecutive CI patients. All patients were users of the Nucleus 24RECA (Freedom) or Nucleus CI512 cochlear implants with the Contour Advance-of-Stylet electrode. RESULTS: The result showed that the t-NRT thresholds were higher for the 250 Hz pulse rate typically used during the intraoperative stimulation under general anaesthesia than for the 80 Hz rate used typically during the postoperative fitting sessions. This difference was more pronounced for the basal electrodes where it exceeded 10 current levels (CL). Pearson's correlation coefficients between the t-NRT-measurements and the stabilised T- and C-levels r ranged between 0.34 and 0.47. CONCLUSION: In conclusion, the magnitude of the ECAP thresholds (t-NRT) recorded intraoperatively depends significantly on the stimulus presentation rate.


Asunto(s)
Implantes Cocleares , Potenciales Evocados Auditivos , Monitoreo Intraoperatorio/métodos , Adulto , Niño , Preescolar , Humanos , Lactante , Persona de Mediana Edad
8.
Eur Arch Otorhinolaryngol ; 274(9): 3291-3293, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28597128

RESUMEN

The meatoplasty of the external auditory canal is a frequently performed otologic procedure in recurrent otitis externa, eczema or frequent accumulation of cerumen due to a narrow meatus of the external ear canal. Numerous surgical techniques have been described. The M-meatoplasty described by Mirck for addressing the external meatus is widely used. However, this technique does not sufficiently enlarge the external ear canal in all cases. Specifically in patients where the ear canal narrowing is most prominent in the postero- and/or anterosuperior quadrants of the lateral meatus the technique needs some modifications. In these cases, an oblique conversion of the M-meatoplasty, the MO-meatocanalplasty, is useful. In cases where the bony canal is also narrow this modification allows for a bony canalplasty while avoiding a retro-auricular approach. The MO-meatocanalplasty can be used in combination with myringoplasty and tympanoplasty.


Asunto(s)
Conducto Auditivo Externo/cirugía , Procedimientos de Cirugía Plástica/métodos , Conducto Auditivo Externo/patología , Humanos
9.
Audiol Neurootol ; 20(4): 222-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25969138

RESUMEN

OBJECTIVE: To evaluate the postoperative changes of the basic electrophysiological and psychophysical parameters in cochlear implant (CI) patients: the impedance of the electrode contacts, the electrically-evoked compound action potential (ECAP) thresholds and the T/C levels. STUDY DESIGN AND SETTING: Retrospective case review in a quaternary otologic referral centre. MATERIALS AND METHODS: Data on the impedance of the electrode contacts, the ECAP thresholds and the T/C levels were collected in 20 consecutive CI patients divided into 2 groups. Group 1 comprised 10 prelingually deaf children implanted before the age of 18 months, and group 2 comprised 10 postlingually deaf adults (average age of 58 years). All patients were users of the Nucleus 24RECA (Freedom, Contour advance off-stylet electrode) CI. RESULTS AND CONCLUSIONS: (1) The mid-portion and the apical electrodes showed a decrease in the impedance values between the 1st and the 6th postoperative months and stabilization in the later course. Impedance of the most basal electrodes grew during the first postoperative months and stabilized later on, but remained higher than the impedance of the mid-portion and the apical electrodes. (2) The neural response telemetry threshold values tended to decrease within the first 3 months after surgery to reach a plateau afterwards. (3) The behavioural threshold levels remained generally stable, except for the basal electrodes where a decrease could be observed. The hearing comfort levels showed an increase during the first 6 months of the implant use and remained stable afterwards.


Asunto(s)
Potenciales de Acción , Implantación Coclear , Implantes Cocleares , Sordera/rehabilitación , Potenciales Evocados , Ajuste de Prótesis , Umbral Auditivo , Preescolar , Estudios de Cohortes , Impedancia Eléctrica , Humanos , Lactante , Persona de Mediana Edad , Estudios Retrospectivos
10.
Ann Otol Rhinol Laryngol ; 124(3): 244-9, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25228668

RESUMEN

BACKGROUND: An isolated malleus handle fracture is rare and presents with vague otological symptoms. Diagnosis depends on careful history taking and otoscopic examination. Different treatment options are available. Reconstruction with hydroxyapatite bone cement is a relatively new technique. OBJECTIVE: The aim of this article is to review the current diagnostic work-up and treatment options and to demonstrate our method of treatment with hydroxyapatite bone cement. METHODS: Three cases, repaired with hydroxyapatite bone cement in a tertiary referral otologic center, were retrospectively analyzed. A review of the literature on diagnosis and treatment procedures was performed. RESULTS: One fracture occurred by withdrawing a finger from the external auditory canal and 2 occurred without clear prior trauma. Our 3 cases were successfully repaired with hydroxyapatite bone cement. CONCLUSION: Diagnosis of an isolated malleus handle fracture still depends on careful clinical examination. In addition to pure tone audiometry, both low and higher frequency tympanometry may be useful. High resolution computed tomography with reformatting through the malleus handle is the most accurate imaging modality. Reconstruction with hydroxyapatite bone cement is reliable by restoring the original situation with only minimal manipulation and without additional ossicular interruption.


Asunto(s)
Fracturas Óseas/cirugía , Pérdida Auditiva Conductiva/cirugía , Martillo/lesiones , Pruebas de Impedancia Acústica , Adulto , Audiometría de Tonos Puros , Tomografía Computarizada de Haz Cónico , Femenino , Fracturas Óseas/complicaciones , Fracturas Óseas/diagnóstico , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/etiología , Humanos , Masculino , Martillo/cirugía , Persona de Mediana Edad , Otoscopía
12.
Int J Audiol ; 52(12): 838-48, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23992489

RESUMEN

OBJECTIVES: To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. DESIGN: Prospective, with sequential enrolment and within-subject comparisons. Post-operative performance using a Freedom Hybrid sound processor was compared with that of pre-operative hearing aids. STUDY SAMPLE: Sixty-six adult hearing-impaired subjects with bilateral severe-to-profound high frequency hearing loss. RESULTS: Group median increase in air-conduction thresholds in the implanted ear for test frequencies 125-1000 Hz was < 15 dB across the population; both immediately and one year post-operatively. Eighty-eight percent of subjects used the Hybrid processor at one year post-op. Sixty-five percent of subjects had significant gain in speech recognition in quiet, and 73% in noise (≥ 20 percentage points/2 dB SNR). Mean SSQ subscale scores were significantly improved (+ 1.2, + 1.3, + 1.8 points, p < 0.001), as was mean HUI3 score (+ 0.117, p < 0.01). Combining residual hearing with CI gave 22-26 %age points mean benefit in speech recognition scores over CI alone (p < 0.01). CONCLUSIONS: Useful residual hearing was conserved in 88% of subjects. Speech perception was significantly improved over preoperative hearing aids, as was sound quality and quality of life.


Asunto(s)
Implantación Coclear/instrumentación , Implantes Cocleares , Corrección de Deficiencia Auditiva/instrumentación , Pérdida Auditiva Sensorineural/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Adulto , Anciano , Anciano de 80 o más Años , Audiometría de Tonos Puros , Audiometría del Habla , Umbral Auditivo , Europa (Continente) , Femenino , Audición , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Pérdida Auditiva Sensorineural/psicología , Humanos , Masculino , Persona de Mediana Edad , Ruido/efectos adversos , Enmascaramiento Perceptual , Personas con Deficiencia Auditiva/psicología , Estudios Prospectivos , Diseño de Prótesis , Calidad de Vida , Reconocimiento en Psicología , Índice de Severidad de la Enfermedad , Inteligibilidad del Habla , Percepción del Habla , Factores de Tiempo , Adulto Joven
13.
Cochlear Implants Int ; 24(2): 95-106, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36448741

RESUMEN

OBJECTIVES: With the introduction of more flexible and thinner electrodes, such as Cochlear's Slim Modiolar Electrode, there is a higher risk of electrode insertion problems, in particular the tip foldover. Timely intraoperative detection of the problem would allow for direct intraoperative correction. This paper describes a non-radiological method for intraoperative tip foldover detection that is applicable in all surgical centers and can quickly deliver accurate results. METHODS: Postoperative radiographs of 118 CI-recipients implanted with Nucleus devices were retrospectively analyzed on the presence of a tip foldover. Electrode Voltage Telemetry (EVT), also called Electric Field Imaging, was performed by means of Cochlear's EVT software tool, which is now integrated into Custom Sound-EP as the Trans-Impedance-Matrix measurement option. Tip foldover detection was automated by using the linear Hough transform for extracting straight-line patterns in the Trans-Impedance Matrix's heatmap. RESULTS: The six cases of electrode tip foldover were accurately identified by the EVT measurements, including two cases with folding location very close to the electrode tip (contact 20). CONCLUSION: Electrode Voltage Telemetry measures the Trans-Impedance Matrix, which can accurately detect tip foldovers of the cochlear implant electrodes within 1 min. This method can be reliably applied in all patients with normal cochlear anatomy and is able to intraoperatively detect foldovers localized even very close to the electrode tip. Application of the linear Hough transform allows for automatic detection of electrode tip foldovers that shows excellent agreement with visual evaluation of the radiological images and the transimpedance matrix's heatmap.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Estudios Retrospectivos , Cóclea/cirugía , Electrodos Implantados , Telemetría/métodos
14.
J Int Adv Otol ; 19(6): 461-467, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38088317

RESUMEN

BACKGROUND: Patients with bilateral vestibulopathy (BVP) are at increased risk of falling and have poor quality of life. Several research groups are currently developing and investigating vestibular implants to treat BVP. The goal was to identify how many patients can be considered eligible for vestibular implantation. METHODS: The objective vestibular implantation criteria for research were applied to the results of the caloric irrigation test, the sinusoidal harmonic acceleration test, the video head impulse test, and the cervical and ocular vestibular evoked myogenic potential tests. RESULTS: Vestibular implant eligibility was situated between 3.6% and 15.7% (semicircular canal implant: 3.6%; otolith implant: 15.7%; combined implant: 4.8%). Only 16 out of the 29 patients (55%) eligible for a vestibular implant had bilateral severe-to-profound hearing loss. The remaining 45% (13/29) thus have better hearing in at least 1 ear. CONCLUSION: Vestibular implant eligibility in an ear, nose, and throat department was situated between 3.6% and 15.7%, depending on the type of implant that was considered. In addition, the data showed that 45% of the eligible patients had normal-to-moderate hearing in at least 1 ear. In other words, only recruiting patients with (bilateral) severe-to-profound hearing loss for vestibular implantation leads to the systematic exclusion of about half of the candidates. Structure-preserving surgical techniques are thus a major future challenge in the field of vestibular implantation.


Asunto(s)
Vestibulopatía Bilateral , Pérdida Auditiva , Potenciales Vestibulares Miogénicos Evocados , Vestíbulo del Laberinto , Humanos , Faringe , Calidad de Vida , Prueba de Impulso Cefálico , Audición , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/cirugía , Potenciales Vestibulares Miogénicos Evocados/fisiología
15.
Front Neurol ; 14: 1248715, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37693771

RESUMEN

Introduction: In a previous manuscript from our research group, the concept of vestibular co-stimulation was investigated in adult subjects who received a cochlear implant (CI). Despite what literature reports state, no signs of vestibular co-stimulation could be observed. Results: In this case report, it was described how a woman, who previously underwent a neurectomy of the left vestibular nerve and suffers from bilateral vestibulopathy (BVP), reported improved balance whenever her CI on the left was stimulating. Unexpectedly, the sway analyses during posturography indeed showed a clinically relevant improvement when the CI was activated. Discussion: Vestibular co-stimulation as a side effect of CI stimulation could not be the explanation in this case due to the ipsilateral vestibular neurectomy. It is more likely that the results can be attributed to the electrically restored auditory input, which serves as an external reference for maintaining balance and spatial orientation. In addition, this patient experienced disturbing tinnitus whenever her CI was deactivated. It is thus plausible that the tinnitus increased her cognitive load, which was already increased because of the BVP, leading to an increased imbalance in the absence of CI stimulation.

16.
Cureus ; 15(11): e49733, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38046713

RESUMEN

This paper provides a step-by-step guide for organizing the scientific program (OSP) of international conferences. Through informal discussions, a panel of experts organizing international conferences came up with this guide, which includes a flowchart, checklist, and detailed discussions of each step. Subsequently, additional specialists were invited to evaluate this synopsis and provide their input. All of the participants approved the final version after the outline was improved. This guide proposes the following six steps: 1) preparation, 2) recruitment, 3) building the agenda, 4) cross-checking the program, 5) reviewing and finalizing, and 6) in-conference refining. Thirteen items are specified across the six main steps in a detailed checklist. This OSP guide includes a flowchart and a checklist for providing a comprehensive manual for establishing, conducting, and organizing international scientific conferences. Understanding the procedures that are expected to be followed when holding a scientific conference enables the involved parties to organize and assign tasks to one another as well as create a schedule that allows them to finish their work on time. This guide can be used at any kind of scientific conference to describe an organized process, resulting in a professional and distinguished scientific program.

17.
Am J Hum Genet ; 84(3): 328-38, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19230858

RESUMEN

Otosclerosis is a common form of progressive hearing loss, characterized by abnormal bone remodeling in the otic capsule. The etiology of the disease is largely unknown, and both environmental and genetic factors have been implicated. To identify genetic factors involved in otosclerosis, we used a case-control discovery group to complete a genome-wide association (GWA) study with 555,000 single-nucleotide polymorphisms (SNPs), utilizing pooled DNA samples. By individual genotyping of the top 250 SNPs in a stepwise strategy, we were able to identify two highly associated SNPs that replicated in two additional independent populations. We then genotyped 79 tagSNPs to fine map the two genomic regions defined by the associated SNPs. The region with the strongest association signal, p(combined) = 6.23 x 10(-10), is on chromosome 7q22.1 and spans intron 1 to intron 4 of reelin (RELN), a gene known for its role in neuronal migration. Evidence for allelic heterogeneity was found in this region. Consistent with the GWA data, expression of RELN was confirmed in the inner ear and in stapes footplate specimens. In conclusion, we provide evidence that implicates RELN in the pathogenesis of otosclerosis.


Asunto(s)
Moléculas de Adhesión Celular Neuronal/genética , Proteínas de la Matriz Extracelular/genética , Genoma Humano , Proteínas del Tejido Nervioso/genética , Otosclerosis/genética , Serina Endopeptidasas/genética , Estudios de Casos y Controles , Moléculas de Adhesión Celular Neuronal/biosíntesis , Oído Interno/metabolismo , Proteínas de la Matriz Extracelular/biosíntesis , Femenino , Estudio de Asociación del Genoma Completo , Humanos , Masculino , Proteínas del Tejido Nervioso/biosíntesis , Otosclerosis/metabolismo , Polimorfismo de Nucleótido Simple , Proteína Reelina , Serina Endopeptidasas/biosíntesis
18.
Eur Arch Otorhinolaryngol ; 269(4): 1095-101, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21935632

RESUMEN

The objective of this study was to compare the hearing outcome using hydroxyapatite (HA) bone cement to bridge the incudostapedial gap versus incus remodelling for ossiculoplasty in case of incudostapedial discontinuity. A non-randomized retrospective study was conducted at a tertiary referral otologic centre. The intervention in 24 primary cases of conductive hearing loss was subsequent middle ear inspection where incudostapedial discontinuity was observed. HA bone cement was used in 10 consecutive cases, and incus remodelling was performed in 14 consecutive cases. Air-bone gap (ABG), bone-conduction (BC) thresholds, and air-conduction (AC) thresholds were evaluated preoperatively and at 3, 6 and 12 months postoperatively. No patients were lost to follow-up. Pure-tone averages were calculated according to the guidelines of the Committee on Hearing and Equilibrium for the evaluation of conductive hearing loss. The Amsterdam Hearing Evaluation Plots are presented. The postoperative ABG closure to within 20 and 10 dB at 12 months was, respectively, 80 and 40% in the HA bone cement group and 57.1 and 28.6% in the standard ossiculoplasty group (no statistically significant difference). However, we observed a statistically significant difference in ABG gain at 6 and 12 months favoring the HA bone cement cases. No short-term or intermediate-term adverse reactions were observed. Hydroxyapatite bone cement bridging ossiculoplasty offers a better intermediate-term ABG gain than standard ossiculoplasty. This new technique is a valuable alternative to conventional ossiculoplasty and presents the practical advantage of being easier and faster.


Asunto(s)
Pérdida Auditiva Conductiva/cirugía , Hidroxiapatitas , Yunque/cirugía , Prótesis Osicular , Reemplazo Osicular/métodos , Procedimientos de Cirugía Plástica/métodos , Cirugía del Estribo/métodos , Adolescente , Adulto , Anciano , Audiometría de Tonos Puros , Conducción Ósea , Niño , Femenino , Estudios de Seguimiento , Audición/fisiología , Pérdida Auditiva Conductiva/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
19.
Hear Res ; 426: 108537, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35672191

RESUMEN

Positioning of the cochlear implant (CI) electrode in relation to the anatomical structures is a key factor for the hearing outcome and the preservation of residual hearing after cochlear implantation. Determining the exact electrode's location is therefore expected to play an important role in optimisation of the electrode design, the surgical techniques and the post-operative device fitting. The aim of this study is the development and validation of a robust and efficient computerised algorithm for three-dimensional (3D) localisation of the CI-electrode contacts with respect to the relevant cochlear structures, such as the basilar membrane and the modiolus, from modern clinical in vivo cone-beam computed tomography (CBCT). In the presented algorithm, the pre- and post-implantation CBCT are spatially aligned. To localise the anatomical structures, a cochlear microanatomical template derived from lab-based X-ray computed microtomography (µCT) measurements is warped to match the patient-specific cochlear shape acquired from pre-implantation CBCT. The electrode-contact locations, determined from the post-operative CBCT, are superimposed onto the cochlear fine-structure of the microanatomical template to localise the array. The accuracy of this method was validated in a temporal bone study by comparing the distance of the electrode contacts from the modiolar wall, as derived by the algorithm from CBCTs, with the distance determined from synchrotron-radiation (SR) µCT on the same specimens. Due to the achievable spatial resolution, good tissue contrast and limited presence of metallic artifacts, the SRµCT technique is considered to be a golden standard in the proposed approach. In contrast to other approaches, this validation method allowed for the evaluation of the final electrode-to-modiolus distance (EMD) error, and covers the error in co-alignment of the images, in the determination of the electrode contact location and in the localisation of the cochlear structures. The absolute mean error on the EMD parameter was determined at 0.11 mm (max = 0.29 mm, SD = 0.07 mm) across five samples, slightly lower than the voxel size of the CBCT-scans. In a retrospective study, the algorithm was applied to identify scalar translocations of the electrode from clinical in vivo CBCT datasets of 23 CI-recipients, which showed perfect (100%) agreement with the blinded opinion of two experienced neuroradiologists.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Estudios Retrospectivos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Tomografía Computarizada de Haz Cónico/métodos
20.
Hear Res ; 426: 108563, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35794046

RESUMEN

Measurement of the complex electrical impedance of the electrode contacts can provide new insights into the factors playing a role in the preservation of residual hearing with cochlear implants (CIs). However, unraveling the contributions related to the different phenomena from impedance data necessitates more advanced measurement and analysis techniques. The present study explores a new impedance measurement option recently included into the cochlear-implant programming software and aims to contribute to a more solid basis for the clinical use of impedance measures as a biomarker for fibrous tissue formation. Twenty adult CI-recipients were followed from surgery until 1 year after implantation by means of Electrode Voltage Telemetry (EVT), also called Electric Field Imaging or TransImpedance-Matrix measurement, and a 4-point technique for probing the voltage between adjacent electrode contacts. The data were compared to the electrode location derived from computed tomography, and to the device usage log. Using our impedance model for electrical stimulation of the cochlea, the polarization impedance related the electrode-tissue interface was determined, and the bulk impedance (access resistance) was split into a near-field and a far-field component. On average, the polarization impedance increased abruptly after surgery, indicating a strong passivation of the electrode contacts before cochlear-implant initiation. Its initial rise resolved almost completely soon after device switchon (2-4 weeks). The gradual increase of the access resistance mainly happened during the first 40 days on a time scale very similar to that observed in a guinea-pig study correlating impedance changes to fibrous tissue growth. The higher increase towards the round window is consistent with the higher amount of tissue observed in histological animal studies close to the electrode entry point. While the initial changes were due to the near-field resistance, the far-field resistance began to rise only after one month for half of the study group, once the near-field component had reached its critical value. This suggests indeed fibrosis initiating near the electrode contacts and spreading thereafter farther away. The near-field resistance positively correlated to device usage. EVT data allow for a further decomposition of the impedance at a cochlear-implant electrode, yielding a more detailed description of the postoperative intracochlear phenomena, such as fibrosis.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cobayas , Animales , Impedancia Eléctrica , Cóclea/fisiología , Fibrosis , Biomarcadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA