Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767321

RESUMEN

PURPOSE: To improve the spatial resolution and repeatability of a non-contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design. METHODS: A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k-space sampling across time. RESULTS: The improved sampling in the periphery of k-space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k-space sampling efficiency also resulted in higher repeatability compared to the original radial approach. CONCLUSION: The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution.

2.
Magn Reson Med ; 92(2): 469-495, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38594906

RESUMEN

Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Marcadores de Spin , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión
3.
Magn Reson Med ; 89(5): 1853-1870, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36533868

RESUMEN

PURPOSE: To extend and optimize a non-contrast MRI technique to obtain whole head 4D (time-resolved 3D) qualitative angiographic and perfusion images from a single scan. METHODS: 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) uses pseudocontinuous labeling with a 3D golden ratio ("koosh ball") readout to continuously image the blood water as it travels through the arterial system and exchanges into the tissue. High spatial/temporal resolution angiograms and low spatial/temporal resolution perfusion images can be flexibly reconstructed from the same raw k-space data. Constant and variable flip angle (CFA and VFA, respectively) excitation schedules were optimized through simulations and tested in healthy volunteers. A conventional sensitivity encoding (SENSE) reconstruction was compared against a locally low rank (LLR) reconstruction, which leverages spatiotemporal correlations. Comparison was also made with time-matched time-of-flight angiography and multi-delay EPI perfusion images. Differences in image quality were assessed through split-scan repeatability. RESULTS: The optimized VFA schedule (2-9°) resulted in a significant (p < 0.001) improvement in image quality (up to 84% vs. CFA), particularly for the lower SNR perfusion images. The LLR reconstruction provided effective denoising without biasing the signal timecourses, significantly improving angiographic and perfusion image quality and repeatability (up to 143%, p < 0.001). 4D CAPRIA performed well compared with time-of-flight angiography and had better perfusion signal repeatability than the EPI-based approach (p < 0.001). CONCLUSION: 4D CAPRIA optimized using a VFA schedule and LLR reconstruction can yield high quality whole head 4D angiograms and perfusion images from a single scan.


Asunto(s)
Imagenología Tridimensional , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Imagenología Tridimensional/métodos , Angiografía Cerebral/métodos , Perfusión
4.
Magn Reson Med ; 89(4): 1323-1341, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36255158

RESUMEN

PURPOSE: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the SNR improvements from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. METHODS: The SNR of a conventional protocol with nine Look-Locker readouts and a 4 × $$ \times $$ 3 time-encoded protocol with three Look-Locker readouts (giving nine matched timepoints) were compared using simulations and in vivo data. Both protocols were compared using readouts with constant flip angles (CFAs) and variable flip angles (VFAs), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. RESULTS: The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared with CFAs by 25% and 21% for the conventional and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest that optimizing the background suppression could improve in vivo SNR by a further 16%. CONCLUSIONS: Time encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles, which can double the SNR compared with a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.


Asunto(s)
Imagenología Tridimensional , Angiografía por Resonancia Magnética , Angiografía por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Encéfalo , Marcadores de Spin , Circulación Cerebrovascular/fisiología , Algoritmos
5.
Magn Reson Med ; 88(1): 341-356, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35253936

RESUMEN

PURPOSE: In chemical exchange saturation transfer imaging, saturation effects between - 2 to - 5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. METHODS: MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain. RESULTS: The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter ( 1.20±0.20 ) and in animals ( 1.27±0.20 ). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed. CONCLUSION: Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Animales , Humanos , Isquemia , Imagen por Resonancia Magnética/métodos , Ratones , Protones , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen
6.
Magn Reson Med ; 88(5): 2021-2042, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35983963

RESUMEN

This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple-timepoint ASL, body ASL, and clinical ASL recommendations.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Circulación Cerebrovascular , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Marcadores de Spin
7.
Magn Reson Med ; 86(4): 2208-2219, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34009682

RESUMEN

PURPOSE: Previously, multi- post-labeling delays (PLD) pseudo-continuous arterial spin labeling (pCASL) protocols have been optimized for the estimation accuracy of the cerebral blood flow (CBF) with/without the arterial transit time (ATT) under a standard kinetic model and a normal ATT range. This study aims to examine the estimation errors of these protocols under the effects of macrovascular contamination, flow dispersion, and prolonged arrival times, all of which might differ substantially in elderly or pathological groups. METHODS: Simulated data for four protocols with varying degrees of arterial blood volume (aBV), flow dispersion, and ATTs were fitted with different kinetic models, both with and without explicit correction for macrovascular signal contamination (MVC), to obtain CBF and ATT estimates. Sensitivity to MVC was defined and calculated when aBV > 0.5%. A previously acquired dataset was retrospectively analyzed to compare with simulation. RESULTS: All protocols showed underestimation of CBF and ATT in the prolonged ATT range. With MVC, the protocol optimized for CBF only (CBFopt) had the lowest sensitivity value to MVC, 33.47% and 60.21% error per 1% aBV in simulation and in vivo, respectively, among multi-PLD protocols. All multi-PLD protocols showed a significant decrease in estimation error when an extended kinetic model was used. Increasing flow dispersion at short ATTs caused increasing CBF and ATT overestimation in all protocols. CONCLUSION: CBFopt was the least sensitive protocol to prolonged ATT and MVC for CBF estimation while maintaining reasonably good performance in estimating ATT. Explicitly including a macrovascular component in the kinetic model was shown to be a feasible approach in controlling for MVC.


Asunto(s)
Circulación Cerebrovascular , Imagen por Resonancia Magnética , Anciano , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Marcadores de Spin
8.
NMR Biomed ; 34(7): e4519, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33939218

RESUMEN

The objective of the current study was to combine a time-encoded pseudocontinuous arterial spin labeling (te-pCASL) scheme with a golden angle radial readout for simultaneous acquisition of angiography and perfusion images from one single dataset, both in a highly flexible single-slice approach as well as within a multislice setting. A te-pCASL preparation and the golden angle radial readout were both used as a temporal resolution tool to retrospectively choose the temporal window for the reconstruction of both angiography and perfusion images from a single-slice dataset. The temporal window could be chosen retrospectively and adjusted to the hemodynamics of the volunteer on the scanner for the single-slice dataset. Angiographic images were reconstructed at a minimum temporal resolution of 69 ms. For the perfusion phase, only the densely sampled center of k-space was included in the reconstruction. For a multislice acquisition, the golden angle radial readout allowed reconstruction of images with different spatial resolutions to provide angiographic and perfusion information over 10 slices. The te-pCASL preparation was used as the only source for dynamic information. The multislice acquisition shows the ability of the golden angle radial readout to display the inflow of the labeled blood into the arteries as well as the perfusion in the tissue with full brain coverage. By combining a te-pCASL preparation with a golden angle radial readout, single-slice high temporal resolution angiography and good quality perfusion images were reconstructed in a flexible manner from a single dataset. Optimizing the golden angle radial readout for reconstructions at multiple spatial resolutions allows for multislice acquisition.


Asunto(s)
Angiografía , Perfusión , Marcadores de Spin , Adulto , Simulación por Computador , Bases de Datos como Asunto , Femenino , Humanos , Masculino , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido , Factores de Tiempo , Adulto Joven
9.
Neuroimage ; 223: 117246, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32853814

RESUMEN

Arterial Spin Labeling (ASL) is a non-invasive, non-contrast, perfusion imaging technique which is inherently SNR limited. It is, therefore, important to carefully design scan protocols to ensure accurate measurements. Many pseudo-continuous ASL (PCASL) protocol designs have been proposed for measuring cerebral blood flow (CBF), but it has not yet been demonstrated which design offers the most accurate and repeatable CBF measurements. In this study, a wide range of literature PCASL protocols were first optimized for CBF accuracy and then compared using Monte Carlo simulations and in vivo experiments. The protocols included single-delay, sequential and time-encoded multi-timepoint protocols, and several novel protocol designs, which are hybrids of time-encoded and sequential multi-timepoint protocols. It was found that several multi-timepoint protocols produced more confident, accurate, and repeatable CBF estimates than the single-delay protocol, while also generating maps of arterial transit time. Of the literature protocols, the time-encoded protocol with T1-adjusted label durations gave the most confident and accurate CBF estimates in vivo (16% and 40% better than single-delay), while the sequential multi-timepoint protocol was the most repeatable (20% more repeatable than single-delay). One of the novel hybrid protocols, HybridT1-adj, was found to produce the most confident, accurate and repeatable CBF estimates out of all the protocols tested in both simulations and in vivo (24%, 47%, and 28% more confident, accurate, and repeatable than single-delay in vivo). The HybridT1-adj protocol makes use of the best aspects of both time-encoded and sequential multi-timepoint protocols and should be a useful tool for accurately and efficiently measuring CBF.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Adulto , Femenino , Humanos , Masculino , Método de Montecarlo , Reproducibilidad de los Resultados , Marcadores de Spin , Adulto Joven
10.
Magn Reson Med ; 83(3): 892-905, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31538357

RESUMEN

PURPOSE: To demonstrate that vessel selectivity in dynamic arterial spin labeling angiography can be achieved without any scan-time penalty or noticeable loss of image quality compared with conventional arterial spin labeling angiography. METHODS: Simulations on a numerical phantom were used to assess whether the increased sparsity of vessel-encoded angiograms compared with non-vessel-encoded angiograms alone can improve reconstruction results in a compressed-sensing framework. Further simulations were performed to study whether the difference in relative sparsity between nonselective and vessel-selective dynamic angiograms was sufficient to achieve similar image quality at matched scan times in the presence of noise. Finally, data were acquired from 5 healthy volunteers to validate the technique in vivo. All data, both simulated and in vivo, were sampled in 2D using a golden-angle radial trajectory and reconstructed by enforcing image domain sparsity and temporal smoothness on the angiograms in a parallel imaging and compressed-sensing framework. RESULTS: Relative sparsity was established as a primary factor governing the reconstruction fidelity. Using the proposed reconstruction scheme, differences between vessel-selective and nonselective angiography were negligible compared with the dominant factor of total scan time in both simulations and in vivo experiments at acceleration factors up to R = 34. The reconstruction quality was not heavily dependent on hand-tuning the parameters of the reconstruction. CONCLUSION: The increase in relative sparsity of vessel-selective angiograms compared with nonselective angiograms can be leveraged to achieve higher acceleration without loss of image quality, resulting in the acquisition of vessel-selective information at no scan-time cost.


Asunto(s)
Arterias/diagnóstico por imagen , Angiografía Cerebral , Procesamiento de Imagen Asistido por Computador/métodos , Marcadores de Spin , Adulto , Algoritmos , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Simulación por Computador , Análisis de Fourier , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Teóricos , Reproducibilidad de los Resultados , Relación Señal-Ruido , Programas Informáticos
11.
Magn Reson Med ; 84(2): 777-786, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31971634

RESUMEN

PURPOSE: To improve the labeling efficiency of pseudo-continuous arterial spin labeling (PCASL) at 7T using parallel transmission (pTx). METHODS: Five healthy subjects were scanned on an 8-channel-transmit 7T human MRI scanner. Time-of-flight (TOF) angiography was acquired to identify regions of interest (ROIs) around the 4 major feeding arteries to the brain, and B1+ and B0 maps were acquired in the labeling plane for tagging pulse design. Complex weights of the labeling pulses for each of the 8 transmit channels were calculated to produce a homogenous radiofrequency (RF) -shimmed labeling across the ROIs. Variable-Rate Selective Excitation (VERSE) pulses were also implemented as a part of the labeling pulse train. Whole-brain perfusion-weighted images were acquired under conditions of RF shimming, VERSE with RF shimming, and standard circularly polarized (CP) mode. The same subjects were scanned on a 3T scanner for comparison. RESULTS: In simulation, VERSE with RF shimming improved the flip-angles across the ROIs in the labeling plane by 90% compared with CP mode. VERSE with RF shimming improved the temporal signal-to-noise ratio by 375% compared with CP mode, but did not outperform a matched 3T sequence with a matched flip-angle. CONCLUSION: We have demonstrated improved PCASL tagging at 7T using VERSE with RF shimming on a commercial head coil under conservative SAR limits at 7T. However, improvements of 7T over 3T may require strategies with less conservative SAR restrictions.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Arterias , Encéfalo/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Marcadores de Spin
12.
Magn Reson Med ; 83(4): 1222-1234, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31605558

RESUMEN

PURPOSE: To assess the impact of the different post-processing options in the calibration of arterial spin labeling (ASL) data on perfusion quantification and its reproducibility. THEORY AND METHODS: Absolute quantification of perfusion measurements is one of the promises of ASL techniques. However, it is highly dependent on a calibration procedure that involves a complex processing pipeline for which no standardized procedure has been fully established. In this work, we systematically compare the main ASL calibration methods as well as various post-processing calibration options, using 2 data sets acquired with the most common sequences, pulsed ASL and pseudo-continuous ASL. RESULTS: Significant and sometimes large discrepancies in ASL perfusion quantification were obtained when using different post-processing calibration options. Nevertheless, when using a set of theoretically based and carefully chosen options, only small differences were observed for both reference tissue and voxelwise methods. The voxelwise and white matter reference tissue methods were less sensitive to post-processing options than the cerebrospinal fluid reference tissue method. However, white matter reference tissue calibration also produced poorer reproducibility results. Moreover, it may also not be an appropriate reference in case of white matter pathology. CONCLUSION: Poor post-processing calibration options can lead to large errors in perfusion quantification, and a complete description of the calibration procedure should therefore be reported in ASL studies. Overall, our results further support the voxelwise calibration method proposed by the ASL white paper, particularly given the advantage of being relatively simple to implement and intrinsically correcting for the coil sensitivity profile.


Asunto(s)
Circulación Cerebrovascular , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Calibración , Reproducibilidad de los Resultados , Marcadores de Spin
13.
Neuroimage ; 199: 304-312, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31158481

RESUMEN

Pseudo-continuous arterial spin labeling (PCASL) MRI has become a popular tool for non-invasive perfusion imaging and angiography. However, it suffers from sensitivity to off-resonance effects within the labeling plane, which can be exacerbated at high field or in the presence of metallic implants, leading to spatially varying signal loss and cerebral blood flow underestimation. In this work we propose a prospective correction technique based on the optimized encoding scheme, which allows the rapid calculation of transverse gradient blips and RF phase modulations that best cancel phase offsets due to off-resonance at the locations of the feeding arteries within the labeling plane. This calculation is based upon a rapidly acquired single-slice fieldmap and is applicable to any number and arrangement of arteries. In addition, this approach is applicable to both conventional PCASL and a vessel-selective variant known as vessel-encoded PCASL (VEPCASL). Through simulations and experiments in healthy volunteers it was shown that in the presence of off-resonance effects a strong bias in the strength of the perfusion signal across vascular territories can be introduced, the signal-to-noise ratio (SNR) efficiency of PCASL and VEPCASL can be severely compromised (∼40% reduction in vivo), and that vessel-selective signal in VEPCASL can be incorrectly assigned. Distortion of the spatial regions placed in the label or control conditions in the presence of off-resonance effects was confirmed in phantom experiments. The application of the proposed correction restored SNR efficiency to levels present in the absence of off-resonance effects and corrected errors in the vascular territory maps derived from VEPCASL. Due to the rapid nature of the required calculations and fieldmap acquisition, this approach could be inserted into protocols with minimal effect on the total scan time.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Adulto , Simulación por Computador , Humanos , Angiografía por Resonancia Magnética/métodos , Angiografía por Resonancia Magnética/normas , Imagen por Resonancia Magnética/normas , Imagen de Perfusión/normas , Fantasmas de Imagen , Marcadores de Spin
14.
Hum Brain Mapp ; 40(10): 2853-2866, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30860660

RESUMEN

Metabolic markers of baseline brain oxygenation and tissue perfusion have an important role to play in the early identification of ischaemic tissue in acute stroke. Although well established MRI techniques exist for mapping brain perfusion, quantitative imaging of brain oxygenation is poorly served. Streamlined-qBOLD (sqBOLD) is a recently developed technique for mapping oxygenation that is well suited to the challenge of investigating acute stroke. In this study a noninvasive serial imaging protocol was implemented, incorporating sqBOLD and arterial spin labelling to map blood oxygenation and perfusion, respectively. The utility of these parameters was investigated using imaging based definitions of tissue outcome (ischaemic core, infarct growth and contralateral tissue). Voxel wise analysis revealed significant differences between all tissue outcomes using pairwise comparisons for the transverse reversible relaxation rate (R 2 '), deoxygenated blood volume (DBV) and deoxyghaemoglobin concentration ([dHb]; p < 0.01 in all cases). At the patient level (n = 9), a significant difference was observed for [dHb] between ischaemic core and contralateral tissue. Furthermore, serial analysis at the patient level (n = 6) revealed significant changes in R 2 ' between the presentation and 1 week scans for both ischaemic core (p < 0.01) and infarct growth (p < 0.05). In conclusion, this study presents evidence supporting the potential of sqBOLD for imaging oxygenation in stroke.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Neuroimagen/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Masculino , Oxígeno/sangre , Accidente Cerebrovascular/metabolismo
15.
Magn Reson Med ; 81(1): 182-194, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30024066

RESUMEN

PURPOSE: To demonstrate the feasibility of a novel noninvasive MRI technique for the comprehensive evaluation of blood flow to the brain: combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA). METHODS: In the CAPRIA pulse sequence, blood labeled with a pseudocontinuous arterial spin labeling pulse train is continuously imaged as it flows through the arterial tree and into the brain tissue using a golden ratio radial readout. From a single raw data set, this flexible imaging approach allows the reconstruction of both high spatial/temporal resolution angiographic images with a high undersampling factor and low spatial/temporal resolution perfusion images with a low undersampling factor. The sparse and high SNR nature of angiographic images ensures that radial undersampling artifacts are relatively benign, even when using a simple regridding image reconstruction. Pulse sequence parameters were optimized through sampling efficiency calculations and the numerical evaluation of modified pseudocontinuous arterial spin labeling signal models. A comparison was made against conventional pseudocontinuous arterial spin labeling angiographic and perfusion acquisitions. RESULTS: 2D CAPRIA data in healthy volunteers demonstrated the feasibility of this approach, with good vessel visualization in the angiographic images and clear tissue perfusion signal when reconstructed at 108-ms and 252-ms temporal resolution, respectively. Images were qualitatively similar to those from conventional acquisitions, but CAPRIA had significantly higher SNR efficiency (48% improvement on average, P = 0.02). CONCLUSION: The CAPRIA technique shows potential for the efficient evaluation of both macrovascular blood flow and tissue perfusion within a single scan, with potential applications in a range of cerebrovascular diseases.


Asunto(s)
Arterias/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Angiografía Cerebral , Angiografía por Resonancia Magnética , Marcadores de Spin , Adulto , Artefactos , Circulación Cerebrovascular , Femenino , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Perfusión , Reproducibilidad de los Resultados , Relación Señal-Ruido
16.
Magn Reson Med ; 81(1): 410-423, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30230589

RESUMEN

PURPOSE: In vessel-encoded pseudo-continuous arterial spin labeling (ve-pCASL), vessel-selective labeling is achieved by modulation of the inversion efficiency across space. However, the spatial transition between the labeling and control conditions is rather gradual, which can cause partial labeling of vessels, reducing SNR-efficiency and necessitating complex postprocessing to decode the vessel-selective signals. The purpose of this study is to optimize the pCASL labeling parameters to obtain a sharper spatial inversion profile of the labeling and thereby minimizing the risk of partial labeling of untargeted arteries. METHODS: Bloch simulations were performed to investigate how the inversion profile was influenced by the pCASL labeling parameters: the maximum (Gmax ) and mean (Gmean ) labeling gradient were varied for ve-pCASL with unipolar and bipolar gradients. The findings in the simulation study were subsequently confirmed in an in vivo volunteer study. Moreover, conventional and optimized settings were compared for 4D-MRA using four-cycle Hadamard ve-pCASL; the visualization of arteries and the presence of the partial labeling were assessed by an expert observer. RESULTS: When using unipolar gradient, lower Gmean resulted in a steeper spatial transition, whereas the width of the control region was broader for higher Gmax . The in vivo study confirmed these findings. When using bipolar gradients, the control region was always very narrow. Qualitative comparison of the 4D-MRA demonstrated lower occurrence of partial labeling when using the optimized gradient parameters. CONCLUSION: The shape of the ve-pCASL inversion profile can be optimized by changing Gmean and Gmax to reduce partial labeling of untargeted arteries.


Asunto(s)
Arterias/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Angiografía por Resonancia Magnética , Marcadores de Spin , Adulto , Algoritmos , Velocidad del Flujo Sanguíneo , Circulación Cerebrovascular , Simulación por Computador , Medios de Contraste , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Riesgo , Relación Señal-Ruido
17.
Magn Reson Med ; 81(4): 2474-2488, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30588656

RESUMEN

PURPOSE: Arterial spin labeling (ASL) MRI is a non-invasive perfusion imaging technique that is inherently SNR limited, so scan protocols ideally need to be rigorously optimized to provide the most accurate measurements. A general framework is presented for optimizing ASL experiments to achieve optimal accuracy for perfusion estimates and, if required, other hemodynamic parameters, within a fixed scan time. The effectiveness of this framework is then demonstrated by optimizing the post-labeling delays (PLDs) of a multi-PLD pseudo-continuous ASL experiment and validating the improvement using simulations and in vivo data. THEORY AND METHODS: A simple framework is proposed based on the use of the Cramér-Rao lower bound to find the protocol design which minimizes the predicted parameter estimation errors. Protocols were optimized for cerebral blood flow (CBF) accuracy or both CBF and arterial transit time (ATT) accuracy and compared to a conventional multi-PLD protocol, with evenly spaced PLDs, and a single-PLD protocol, using simulations and in vivo experiments in healthy volunteers. RESULTS: Simulations and in vivo data agreed extremely well with the predicted performance of all protocols. For the in vivo experiments, optimizing for just CBF resulted in a 48% and 15% decrease in CBF errors, relative to the reference multi-PLD and single-PLD protocols, respectively. Optimizing for both CBF and ATT reduced CBF errors by 37%, without a reduction in ATT accuracy, relative to the reference multi-PLD protocol. CONCLUSION: The presented framework can effectively design ASL experiments to minimize measurement errors based on the requirements of the scan.


Asunto(s)
Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Hemodinámica , Imagen por Resonancia Magnética/métodos , Marcadores de Spin , Adulto , Algoritmos , Encéfalo/irrigación sanguínea , Simulación por Computador , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Método de Montecarlo , Reproducibilidad de los Resultados , Adulto Joven
18.
Magn Reson Med ; 81(5): 2995-3006, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30506957

RESUMEN

PURPOSE: The recently introduced "Acquisition of ConTRol and labEled imaging in the Same Shot" (ACTRESS) approach was designed to halve the scan time of arterial spin labeling (ASL) -based 4D-MRA by obtaining both labeled and control images in a single Look-Locker readout. However, application for vessel-selective labeling remains difficult. The aim of this study was to achieve a combination of ACTRESS and vessel-selective labeling to halve the scan time of vessel-selective 4D-MRA. METHODS: By Bloch equation simulations, Look-Locker pseudocontinuous-ASL (pCASL) was optimized to achieve constant static tissue signal across the multidelay readout, which is essential for the ACTRESS approach. Additionally, a new subtraction scheme was proposed to achieve visualization of the inflow phase even when labeled blood will have already arrived in the distal arteries during the first phase acquisition due to the long duration of the pCASL labeling module. In vivo studies were performed to investigate the signal variation of the static tissue, as well as to assess image quality of vessel-selective 4D-MRA with ACTRESS. RESULTS: In in vivo studies, the mean signal variation of the static tissue was 8.98% over the Look-Locker phases, thereby minimizing the elevation of background signal. This allowed visualization of peripheral arteries and slowly arriving arterial blood with image quality as good as conventional pCASL within half the acquisition time. Vessel-selective pCASL-ACTRESS enabled the separated visualization of vessels arising from internal and external carotid arteries within this shortened acquisition time. CONCLUSION: By combining vessel-selective pCASL and ACTRESS approach, 4D-MRA of a single targeted arterial tree was achieved in a few minutes.


Asunto(s)
Encéfalo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética , Marcadores de Spin , Aceleración , Adulto , Algoritmos , Arterias , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Medios de Contraste/química , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
19.
Magn Reson Med ; 82(4): 1412-1423, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31131930

RESUMEN

PURPOSE: T2 -relaxation-under-spin-tagging (TRUST) is an MR technique for the non-invasive assessment of whole-brain cerebral oxygen extraction fraction (OEF), through measurement of the venous blood T2 relaxation time in the sagittal sinus. A key limitation of TRUST, however, is the lack of spatial specificity of the measurement. We sought to develop a modified TRUST sequence, selective localized TRUST (SL-TRUST), having sensitivity to venous blood T2 within a targeted brain region, and therefore achieving spatially localized measurements of cerebral tissue OEF, while still retaining acquisition in the sagittal sinus. METHODS: A method for selective localization of TRUST sequence was developed, and the reproducibility of the technique was evaluated in healthy participants. Regional measurements were achieved for a single hemisphere and for a 3D-localized 70 × 70 × 80 mm3 tissue region using SL-TRUST and compared to a global TRUST measure. An additional measure of venous blood T1 in the sagittal sinus was used to estimate subject-specific hematocrit. Six subjects were scanned over 4 sessions, including intra-session repeat measurements. RESULTS: The average T2 in the sagittal sinus was found to be 60.8 ± 8.9, 62.7 ± 7.9, 64.6 ± 8.4, and 66.3 ± 10.3 ms (mean ± SD) for conventional TRUST, global SL-TRUST, hemispheric SL-TRUST, and 3D-localized SL-TRUST, respectively. Intra-, inter-session, and inter-subject coefficients of variation for OEF using SL-TRUST were found to be comparable and in some cases superior to those obtained using TRUST. CONCLUSION: OEF comparison of 2 contralateral regions was achievable in under 5 min suggesting SL-TRUST offers potential for quantifying regional OEF differences in both healthy and clinical populations.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética/métodos , Oximetría/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Femenino , Hematócrito/métodos , Humanos , Masculino
20.
Magn Reson Med ; 81(3): 1595-1604, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30357925

RESUMEN

PURPOSE: To establish the feasibility of using vessel-encoded pseudocontinuous arterial spin labeling (VEPCASL) for noninvasive vascular territory imaging (VTI) and artery-specific dynamic angiography of a large number of arterial branches above the circle of Willis within a clinically feasible scan time. METHODS: 3D time-of-flight angiography was used to select a labeling plane and establish 7 pairs of encoding cycles. These were used for VEPCASL VTI and dynamic 2D angiography (8 min and 3 min acquisition times, respectively) in healthy volunteers, allowing the separation of signals arising from 13 arterial branches (including extracranial arteries) in postprocessing. To demonstrate the clinical potential of this approach, VEPCASL angiography was also applied in 5 patients with brain arteriovenous malformation (AVM). RESULTS: In healthy volunteers, the artery-specific filling of the vascular tree and resulting perfusion territories were well depicted. SNRs were approximately 5 times higher than those achievable with single-artery selective methods. Blood supply to the AVMs was well visualized in all cases, showing the main feeding arteries and venous drainage. CONCLUSIONS: VEPCASL is a highly efficient method for both VTI and dynamic angiography of a large number of arterial branches, providing a comprehensive picture of vascular flow patterns and the effect on downstream tissue perfusion within an acceptable scan time. Automation of labeling plane and vessel-encoding selection would improve robustness and efficiency, and further refinement could allow quantitative blood flow measurements to be obtained. This technique shows promise for visualizing the blood supply to lesions and collateral flow patterns.


Asunto(s)
Angiografía , Arterias/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Círculo Arterial Cerebral/diagnóstico por imagen , Marcadores de Spin , Adulto , Malformaciones Arteriovenosas/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Encéfalo/irrigación sanguínea , Femenino , Voluntarios Sanos , Hemodinámica , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Perfusión , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA