Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Med Phys ; 38(3): 1534-46, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21520865

RESUMEN

PURPOSE: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. METHODS: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. RESULTS: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. CONCLUSIONS: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X/instrumentación , Absorción , Animales , Modelos Lineales , Ratones , Fantasmas de Imagen , Microtomografía por Rayos X
2.
Technol Cancer Res Treat ; 5(4): 343-50, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16866565

RESUMEN

Multi-modality combinations of SPECT/CT and PET/CT have proven to be highly successful in the clinic and small animal SPECT/CT and PET/CT are becoming the norm in the research and drug development setting. However, the use of ionizing radiation from a high-resolution CT scanner is undesirable in any setting and particularly in small animal imaging (SAI), in laboratory experiments where it can result in radiation doses of sufficient magnitude that the experimental results can be influenced by the organism's response to radiation. The alternative use of magnetic resonance (MR) would offer a high-resolution, non-ionizing method for anatomical imaging of laboratory animals. MR brings considerably more than its 3D anatomical capability, especially regarding the imaging of laboratory animals. Dynamic MR imaging techniques can facilitate studies of perfusion, oxygenation, and diffusion amongst others. Further, MR spectroscopy can provide images that can be related to the concentration of endogenous molecules in vivo. MR imaging of injected contrast agents extends MR into the domain of molecular imaging. In combination with nuclear medicine (NM) SPECT and PET modalities in small animal imaging, MR would facilitate studies of dynamic processes such as biodistribution, pharmacokinetics, and pharmacodynamics. However, the detectors for nearly all PET and SPECT systems are still based on vacuum tube technology, namely: photomultiplier tubes (PMT's) in which the signal is generated by transporting electrons over a substantial distance within an evacuated glass tube, making them inoperable in even small magnetic fields. Thus the combination of SPECT or PET with MR has not been practical until the recent availability of semiconductor detectors such as silicon avalanche photodiodes (APD's) for PET and CdZnTe (CZT) detectors for SPECT coupled with the availability of high-density low noise ASIC electronics to read out the semiconductor detectors. The strong advantage of these technologies over PMT's is their insensitivity to magnetic fields which makes their use in co-axial multi-modality nuclear medicine/magnetic resonance instrumentation possible.


Asunto(s)
Diagnóstico por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Medicina Nuclear/métodos , Animales , Computadores , Rayos gamma , Humanos , Imagen por Resonancia Magnética/tendencias , Medicina Nuclear/tendencias , Tomografía de Emisión de Positrones/métodos , Radiación Ionizante , Semiconductores , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos
3.
Phys Med ; 21 Suppl 1: 76-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17646000

RESUMEN

Sentinel lymph node (SLN) biopsy is now standard practice in the management of many breast cancer patients. Localization protocols vary in complexity and rates of success. The least complex involve only intraoperative gamma counting of radiotracer uptake or intraoperative visualization of blue-dye uptake; the most complex involve preoperative gamma imaging, intraoperative counting and intraoperative dye visualization. Intraoperative gamma imaging may improve some protocols. This study was conducted to obtain preliminary experience and information regarding intraoperative imaging. Sixteen patients were enrolled: 8 in a protocol that included intraoperative counting and dye visualization (probe/dye), 8 in a protocol that involved intraoperative imaging, counting and dye visualization (camera/probe/dye). Preoperative imaging of all 16 patients was performed using a GE 500 gamma camera with a LEAP collimator (300 cpm/muCi). The results of this imaging were not, however, given to the surgeon until the surgeon had completed the procedures required for the study. A Care Wise C-Trak probe was used for intraoperative counting. A Gamma Medica Inc. GammaCAM/OR (12.5 x 12.5 cm FOV) with a LEHR collimator (135 cpm/muCi) was used for intraoperative imaging. Times from start of surgery to external detection of a radioactive focus and to completion of excision of SLNs were recorded. Foci were detected preoperatively via imaging in 16/16 patients. Intraoperative external detection using the probe was accomplished in less than 4 min (mean = 1.5 min) in 15/16 patients, and via intraoperative imaging in 6/8 patients. The average time for completion of excision of nodes was 19 min for probe/dye and 28 min for camera/probe/dye. In one probe/dye case, review of the preoperative images prompted the surgeon to resume axillary dissection and remove one additional SLN.

4.
Mol Imaging Biol ; 6(3): 131-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15193247

RESUMEN

PURPOSE: Coronary angiography defines geometry of lumen of artery. However, perhaps 70% of heart attacks occur when minimally obstructive thin capped fibroatheroma rupture, causing thrombus and arterial occlusion. We have developed an intravascular imaging detector to identify vulnerable coronary artery plaque. PROCEDURE: Detector measures beta or conversion electron emissions from plaque-binding radiotracers. Detector assembly fits into a 2-mm diameter catheter and overcomes technical constraints of size, sensitivity, and conformance to intravascular environment. RESULTS: Device was tested by stepping test point sources past detector to verify function. System resolution is 6.7 mm and sensitivity is 400 cps/microCi one mm from detector. CONCLUSION: This prototype is a first step in imaging of labeled vulnerable plaque in coronary arteries. This type of system may assist in development of targeted and cost effective therapies to lower incidence of acute coronary artery diseases (CAD) such as unstable angina, acute myocardial infarction, and sudden cardiac death.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Partículas beta , Enfermedad de la Arteria Coronaria/terapia , Humanos , Trazadores Radiactivos , Cintigrafía
5.
Med Phys ; 29(11): 2529-40, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12462719

RESUMEN

A novel Si-PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual) tumor identification during surgery. This class of collimator-less nuclear imaging device has a higher signal response for direct interactions than its scintillator-optical detector-based counterparts. Monte Carlo simulations with 635 keV betas were performed, yielding maximum and projected ranges of 1.64 and 0.55 mm in Si. Up to 90% of these betas were completely absorbed in the first 0.30 mm. Based on these results, 300 microm thick prototype Si detector arrays were designed in a 16 x 16 crossed-grid arrangement with 0.8 mm wide orthogonal strips on 1.0 mm pitch. A NIM- and CAMAC-based high-density data acquisition and processing system was used to collect the list mode data. The system was calibrated by comparisons of measured spectra to energy deposition simulations or by direct measurement of various >100 keV conversion electron or beta emitters. Mean electronic noise per strip was <3.6 keV FWHM at room temperature. When detecting positrons, which have an accompanying 511 keV annihilation background, the flood irradiated beta/gamma ratio was approximately 40, indicating that beta images could be made without the use of background rejection techniques. The intrinsic spatial resolution corresponds to the 1 x 1 mm2 pixel size, and measurements of beta emitting point and line sources yielded FWHM resolutions of 1.5 (lateral) and 2.5 mm (diagonal), respectively, with the larger widths due to particle range blurting effects. Deconvolution of the finite source size yielded intrinsic resolutions that corresponded to the image pixel size. Transmission images of circle and line phantoms with various hole sizes and pitch were resolved with either pure beta or positron irradiation without a background correction. This novel semiconductor imaging device facilitates high charged particle and low gamma sensitivity, high signal/noise ratio, and allows for compact design to potentially aid surgical guidance by providing in situ images of clinical relevance.


Asunto(s)
Radiometría/instrumentación , Silicio , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada de Emisión/instrumentación , Partículas alfa , Partículas beta , Calibración , Electrodos , Electrones , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/instrumentación , Miniaturización , Monitoreo Intraoperatorio/instrumentación , Método de Montecarlo , Fantasmas de Imagen , Radiometría/métodos , Reproducibilidad de los Resultados , Semiconductores , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos , Transductores
6.
Phys Med Biol ; 56(4): N63-9, 2011 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-21258141

RESUMEN

In this study, we investigated the in vivo application of an integrated small-animal magnetic resonance (MR) and gamma-ray imaging system that consists of a semiconductor-based radiation detector, a parallel-hole collimator, and a specialized radiofrequency coil. Gadodiamide and (99m)Tc sestimibi agents were injected simultaneously into a mouse, and simultaneous dynamic contrast-enhanced MR and scintigraphic images of the kidneys were acquired. The time curves of both the MR signal intensity and radioactivity indicate a rapid uptake of the agents followed by a more gradual excretion, consistent with the previously reported literature. Our results demonstrate the feasibility of measuring multiple biological processes at the same time using both MR contrast agents and radiotracers.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética/métodos , Cintigrafía/métodos , Animales , Femenino , Riñón/diagnóstico por imagen , Ratones , Ratones Endogámicos BALB C , Tecnecio Tc 99m Sestamibi
7.
Phys Med Biol ; 56(21): 6809-22, 2011 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-21971137

RESUMEN

Despite its high sensitivity, the variable specificity of magnetic resonance imaging (MRI) in breast cancer diagnosis can lead to unnecessary biopsies and over-treatment. Scintimammography (SMM) could potentially supplement MRI to improve the diagnostic specificity. The synergistic combination of MRI and SMM (MRSMM) could result in both high sensitivity from MRI and high specificity from SMM. Development of such a dual-modality system requires the integration of a radio frequency (RF) coil and radiation detector in a strong magnetic field without significant mutual interference. In this study, we developed and tested a unilateral breast array coil specialized for MRSMM imaging. The electromagnetic field, specific absorption ratio and RF coil parameters with cadmium-zinc-telluride detectors encapsulated in specialized RF and gamma-ray shielding mounted within the RF coil were investigated through simulation and experimental measurements. Simultaneous MR and SMM images of a breast phantom were also acquired using the integrated MRSMM system. This work, we feel, represents an important step toward the fabrication of a working MRSMM system.


Asunto(s)
Neoplasias de la Mama/patología , Mama/patología , Imagen por Resonancia Magnética/instrumentación , Mamografía/instrumentación , Neoplasias de la Mama/diagnóstico por imagen , Cadmio , Cobre/química , Campos Electromagnéticos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Fantasmas de Imagen , Telurio , Zinc
8.
Technol Cancer Res Treat ; 9(1): 21-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20082527

RESUMEN

Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Imagen de Cuerpo Entero/métodos , Animales , Compuestos de Cadmio/química , Ratones , Ratones Desnudos , Fantasmas de Imagen , Radiofármacos , Telurio/química
9.
Phys Med Biol ; 55(6): 1563-75, 2010 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-20164533

RESUMEN

In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B(0) field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Imagen de Cuerpo Entero/métodos , Compuestos de Cadmio/química , Campos Electromagnéticos , Humanos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/química , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Imagen de Cuerpo Entero/instrumentación , Zinc/química
10.
J Am Coll Cardiol ; 47(8 Suppl): C97-100, 2006 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-16631517

RESUMEN

An intravascular catheter was developed to identify inflammation in coronary atheroma. Inflammation in atheroma is associated with large numbers of macrophages. These cells have increased metabolism, increased expression of chemotactic receptors, and a high frequency of apoptosis-associated phosphatidylserine expression. Each of these parameters can be identified in vivo using specific radiolabeled agents: metabolism can be identified with 18F fluorodeoxyglucose (FDG), receptor expression with 99mTc monocyte chemotactic peptide-1, and apoptosis with 99mTc annexin V. The locally increased concentration of these tracers is readily demonstrable in experimental lesions by ex vivo autoradiography; however, the small lesion size makes it difficult to identify atheroma in the coronaries with conventional imaging equipment. In contrast, with a radiation-sensitive catheter, optimized to sense charged particle rather than gamma or x-radiation, specific lesions could be identified and localized. Charged particle radiation is emitted as a byproduct of nearly all radioactive decay but is typically most abundant in radionuclides that decay by beta emission (either positrons or negatrons). Prototype catheters, using a plastic scintillator mated to an optical fiber, have been tested in the laboratory with the positron-emitting radiopharmaceutical 18FDG. The catheter had sufficient sensitivity to detect lesions concentrating nanocurie concentrations of 18FDG. Ex vivo experiments in apo-e-/- mice confirmed the ability of the catheter to detect 18FDG in aortic lesions. These feasibility studies demonstrate the sensitivity of a beta-sensitive catheter system. Additional mechanical refinements are needed to optimize the system in anticipation of in vivo animal studies.


Asunto(s)
Aterosclerosis/diagnóstico por imagen , Cateterismo/instrumentación , Animales , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Humanos , Trazadores Radiactivos , Radiología Intervencionista , Cintigrafía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA