1.
Sensors (Basel) ; 20(14)2020 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-32708170

RESUMEN

Photoacoustic imaging (PAI) combines optical contrast with ultrasound spatial resolution and can be obtained up to a depth of a few centimeters. Hand-held PAI systems using linear array usually operate in reflection mode using a dark-field illumination scheme, where the optical fiber output is attached to both sides of the elevation plane (short-axis) of the transducer. More recently, bright-field strategies where the optical illumination is coaxial with acoustic detection have been proposed to overcome some limitations of the standard dark-field approach. In this paper, a novel multiangle long-axis lateral illumination is proposed. Monte Carlo simulations were conducted to evaluate light delivery for three different illumination schemes: bright-field, standard dark-field, and long-axis lateral illumination. Long-axis lateral illumination showed remarkable improvement in light delivery for targets with a width smaller than the transducer lateral dimension. A prototype was developed to experimentally demonstrate the feasibility of the proposed approach. In this device, the fiber bundle terminal ends are attached to both sides of the transducer's long-axis and the illumination angle of each fiber bundle can be independently controlled. The final PA image is obtained by the coherent sum of subframes acquired using different angles. The prototype was experimentally evaluated by taking images from a phantom, a mouse abdomen, forearm, and index finger of a volunteer. The system provided light delivery enhancement taking advantage of the geometry of the target, achieving sufficient signal-to-noise ratio at clinically relevant depths.

2.
J Ultrasound Med ; 37(1): 255-261, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28736982

RESUMEN

OBJECTIVES: Although power Doppler imaging has been used to quantify tissue and organ vascularity, many studies showed that limitations in defining adequate ultrasound machine settings and attenuation make such measurements complex to be achieved. However, most of these studies were conducted by using the output of proprietary software, such as Virtual Organ computer-aided analysis (GE Healthcare, Kretz, Zipf, Austria); therefore, many conclusions may not be generalizable because of unknown settings and parameters used by the software. To overcome this limitation, our goal was to evaluate the impact of the flow velocity, pulse repetition frequency (PRF), and wall motion filter (WMF) on power Doppler image quantification using beam-formed ultrasonic radiofrequency data. METHODS: The setup consisted of a blood-mimicking fluid flowing through a phantom. Radiofrequency signals were collected using PRFs ranging from 0.6 to 10 kHz for 6 different flow velocities (5-40 cm/s). Wall motion filter cutoff frequencies were varied between 50 and 250 Hz. RESULTS: The power Doppler magnitude was deeply influenced by the WMF cutoff frequency. The effect of using different WMF values varied with the PRF; therefore, the power Doppler signal intensity was dependent on the PRF. Finally, we verified that power Doppler quantification can be affected by the aliasing effect, especially when using a PRF lower than 1.3 kHz. CONCLUSIONS: The WMF and PRF greatly influenced power Doppler quantification, mainly when flow velocities lower than 20 cm/s were used. Although the experiments were conducted in a nonclinical environment, the evaluated parameters are equivalent to those used in clinical practice, which makes them valuable for aiding the interpretation of related data in future research.


Asunto(s)
Velocidad del Flujo Sanguíneo , Vasos Sanguíneos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Ultrasonografía Doppler/métodos , Modelos Biológicos , Movimiento (Física) , Fantasmas de Imagen , Reproducibilidad de los Resultados
3.
Muscle Nerve ; 56(3): 393-398, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27977870

RESUMEN

INTRODUCTION: We sought to compare median nerve elasticity between leprosy patients (LPs) and healthy volunteers (HVs) using ultrasound elastography (UE). METHODS: Two radiologists independently measured the strain ratio of the median nerve/flexor digitorum superficialis muscle (MN/FDSM) of 18 LP and 18 HV using real-time freehand UE. Statistical analysis included intra-class correlation coefficients (ICC) and Mann-Whitney test. RESULTS: The MN/FDSM strain ratios of the LP and HV were 2.66 ± 1.30 and 3.52 ± 0.93, respectively (P < 0.05). We observed a significantly lower MN/FDSM strain ratio in LP with reactions (types 1 and 2 cutaneous reactions associated with or without neuritis) (2.30 ± 0.91) compared with LP without reactions (3.60 ± 1.70). We found no significant differences between HV and LP without reactions. The intra- and inter-observer ICCs were 0.50 (95% confidence interval [CI], 0.11-0.72) and 0.34 (95% CI, 0.28-0.52), respectively. CONCLUSIONS: MN/FDSM strain ratios were significantly lower in LP with reactions. UE may be useful for nerve elasticity evaluation in leprosy. Muscle Nerve 56: 393-398, 2017.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Lepra/diagnóstico por imagen , Nervio Mediano/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Antebrazo/diagnóstico por imagen , Antebrazo/inervación , Antebrazo/fisiopatología , Humanos , Lepra/fisiopatología , Masculino , Nervio Mediano/fisiopatología , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Estudios Prospectivos , Adulto Joven
4.
J Ultrasound Med ; 34(12): 2245-51, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26543167

RESUMEN

OBJECTIVES: To determine the influence of the pulse repetition frequency (PRF) and wall motion filter on the 3-dimensional (3D) power Doppler vascularization-flow index (VFI) and volumetric pulsatility index (PI) obtained from spatiotemporal image correlation (STIC) data sets acquired from a common carotid artery of a healthy participant. METHODS: We acquired 11 STIC data sets, 1 for each PRF value ranging from 0.6 to 9.0 kHz. Vascularization-flow index and volumetric PI values were determined from the 440 static 3D data sets contained in these STIC data sets. Additionally, 3 sets of radio-frequency data were acquired for offline processing of different wall motion filter values for PRF values of 0.6, 3.3, and 10 kHz. RESULTS: We constructed VFI curves and observed 2 patterns: a flattened pattern with a low PRF and a triphasic pattern with a high PRF, correlating with the known pulsed wave Doppler profile of this vessel. Volumetric PI values were around 0 for low PRF settings and increased with increasing PRF. Analysis of the radiofrequency data showed that increasing wall motion filter values gradually filtered out the low-velocity power Doppler signals while retaining the higher-velocity ones, allowing the distinction of integrated power Doppler signal velocity throughout the cardiac cycle. CONCLUSIONS: We conclude that the PRF and wall motion filter dramatically influence 3D power Doppler indices and the volumetric PI, and the use of PRF values in which minimum VFI values are measured during the diastolic phase in the spectral Doppler wave may validate the use of the volumetric PI.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiología , Imagenología Tridimensional/métodos , Ultrasonografía Doppler de Pulso/métodos , Ultrasonografía/métodos , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Volumen Sanguíneo/fisiología , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
5.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39046299

RESUMEN

Magnetomotive ultrasound (MMUS) stands out as a promising and effective ultrasound-based method for detecting magnetic nanoparticles (MNPs) within tissues. This innovative technique relies on the precise estimation of micrometric displacements induced by the interaction of an external magnetic field with MNPs. Pulsed MMUS has emerged as a strategic alternative to address limitations associated with harmonic excitation, such as heat generation in amplifiers and coils, frequency-dependent tissue mechanical responses, and prolonged magnetic field rise times. Despite the growing interest in MMUS, the devices conventionally employed to excite the coil are not specifically tailored to generate intense magnetic fields while minimizing interference with the transient behavior of induced displacements. To bridge this gap, our work introduces the design and fabrication of two pulse generators: one based on a capacitor-discharge circuit and the other on a resonant-inverter circuit. We evaluated the performance of these pulse generators by considering parameters such as the magnetic field generated, rise and fall times, and their ability to supply sustained current for varied pulse widths across different pulse repetition frequencies. Furthermore, we carried out a practical MMUS implementation using tissue-mimicking phantoms, demonstrating the capability of both devices to achieve magnetic fields of up to 1 T and average displacements of 25 µm within the phantom. In addition, we estimated the shear wave velocity, effective shear modulus, and their temperature-dependent variations. Our findings highlight the versatility and efficacy of the proposed pulse generators and emphasize their potential as low-cost platforms for theranostic applications, enabling the assessment of targeted entities within biological tissues.


Asunto(s)
Fantasmas de Imagen , Ultrasonografía , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Campos Magnéticos , Análisis Costo-Beneficio , Diseño de Equipo , Nanopartículas de Magnetita/química
6.
J Ultrasound Med ; 32(10): 1831-6, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24065264

RESUMEN

Spatiotemporal image correlation can be used to acquire 3-dimensional power Doppler information across a single cardiac cycle. Assessment and comparison of the systolic and diastolic components of the data sets allow measurement of the recently introduced "volumetric pulsatility index" (vPI) through algorithms comparable with those used in 2-dimensional Doppler waveform analysis. The vPI could potentially overcome the dependency on certain machine settings, such as power, color gain, pulse repetition frequency, and attenuation, since these factors would affect the power Doppler signal equally throughout the cardiac cycle. The objective of this study was to compare the effect of color gain on the vascularization index (VI), vascularization-flow index (VFI), and vPI using an in vitro flow phantom model. We separated gains into 3 bands: -8 to -1 (no noise), -1 to +5 (low noise), and +5 to +8 (obvious noise). The vPI was determined from the 3-dimensional VI or VFI using the formula vPI = (maximum - minimum)/mean. Using no-noise gains, we observed that although the VI and VFI increased linearly with gain, the vPI was substantially less dependent on this adjustment. The VI and VFI continued to increase linearly with gain, whereas the vPI decreased slightly using low-noise gains. When gain was increased above the lower limit of obvious noise (+5), the VI and VFI increased noticeably, and there were marked reductions in both vPI values. We conclude that the vPI is less affected by changes in color gain than the VI and VFI at no-noise gains.


Asunto(s)
Algoritmos , Vasos Sanguíneos/diagnóstico por imagen , Vasos Sanguíneos/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Flujo Pulsátil/fisiología , Ultrasonografía Doppler/métodos , Velocidad del Flujo Sanguíneo/fisiología , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Modelos Cardiovasculares , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis Espacio-Temporal , Ultrasonografía Doppler/instrumentación
7.
Photoacoustics ; 33: 100555, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38021286

RESUMEN

Photoacoustic (PA) imaging has the potential to deliver non-invasive diagnostic information. However, skin tone differences bias PA target visualization, as the elevated optical absorption of melanated skin decreases optical fluence within the imaging plane and increases the presence of acoustic clutter. This paper demonstrates that short-lag spatial coherence (SLSC) beamforming mitigates this bias. PA data from the forearm of 18 volunteers were acquired with 750-, 810-, and 870-nm wavelengths. Skin tones ranging from light to dark were objectively quantified using the individual typology angle (ITA°). The signal-to-noise ratio (SNR) of the radial artery (RA) and surrounding clutter were measured. Clutter was minimal (e.g., -16 dB relative to the RA) with lighter skin tones and increased to -8 dB with darker tones, which compromised RA visualization in conventional PA images. SLSC beamforming achieved a median SNR improvement of 3.8 dB, resulting in better RA visualization for all skin tones.

8.
Nanomaterials (Basel) ; 13(3)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36770395

RESUMEN

The development of nanomaterials has drawn considerable attention in nanomedicine to advance cancer diagnosis and treatment over the last decades. Gold nanorods (GNRs) and magnetic nanoparticles (MNPs) have been known as commonly used nanostructures in biomedical applications due to their attractive optical properties and superparamagnetic (SP) behaviors, respectively. In this study, we proposed a simple combination of plasmonic and SP properties into hybrid NPs of citrate-coated manganese ferrite (Ci-MnFe2O4) and cetyltrimethylammonium bromide-coated GNRs (CTAB-GNRs). In this regard, two different samples were prepared: the first was composed of Ci-MnFe2O4 (0.4 wt%), and the second contained hybrid NPs of Ci-MnFe2O4 (0.4 wt%) and CTAB-GNRs (0.04 wt%). Characterization measurements such as UV-Visible spectroscopy and transmission electron microscopy (TEM) revealed electrostatic interactions caused by the opposing surface charges of hybrid NPs, which resulted in the formation of small nanoclusters. The performance of the two samples was investigated using magneto-motive ultrasound imaging (MMUS). The sample containing Ci-MnFe2O4_CTAB-GNRs demonstrated a displacement nearly two-fold greater than just using Ci-MnFe2O4; therefore, enhancing MMUS image contrast. Furthermore, the preliminary potential of these hybrid NPs was also examined in magnetic hyperthermia (MH) and photoacoustic imaging (PAI) modalities. Lastly, these hybrid NPs demonstrated high stability and an absence of aggregation in water and phosphate buffer solution (PBS) medium. Thus, Ci-MnFe2O4_CTAB-GNRs hybrid NPs can be considered as a potential contrast agent in MMUS and PAI and a heat generator in MH.

9.
Materials (Basel) ; 15(9)2022 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-35591525

RESUMEN

Magnetic hyperthermia (MHT) is a therapy that uses the heat generated by a magnetic material for cancer treatment. Magnetite nanoparticles are the most used materials in MHT. However, magnetite has a high Curie temperature (Tc~580 °C), and its use may generate local superheating. To overcome this problem, strontium-doped lanthanum manganite could replace magnetite because it shows a Tc near the ideal range (42-45 °C). In this study, we developed a smart composite formed by an F18 bioactive glass matrix with different amounts of Lanthanum-Strontium Manganite (LSM) powder (5, 10, 20, and 30 wt.% LSM). The effect of LSM addition was analyzed in terms of sinterability, magnetic properties, heating ability under a magnetic field, and in vitro bioactivity. The saturation magnetization (Ms) and remanent magnetization (Mr) increased by the LSM content, the confinement of LSM particles within the bioactive glass matrix also caused an increase in Tc. Calorimetry evaluation revealed a temperature increase from 5 °C (composition LSM5) to 15 °C (LSM30). The specific absorption rates were also calculated. Bioactivity measurements demonstrated HCA formation on the surface of all the composites in up to 15 days. The best material reached 40 °C, demonstrating the proof of concept sought in this research. Therefore, these composites have great potential for bone cancer therapy and should be further explored.

10.
Artículo en Inglés | MEDLINE | ID: mdl-34757902

RESUMEN

Highly sensitive ultrasound probes are needed to expand the capabilities of biomedical ultrasound and industrial nondestructive testing (NDT). Pursuing better imaging quality, while keeping fabrication costs low, is an important trend in the current development of ultrasound imaging systems. In this article, we report the development and characterization of an ultrasonic transducer that (super)focuses ultrasonic waves beyond the so-called diffraction limit, that is, the beamwaist is roughly narrower than one wavelength. The transducer comprises an additive manufactured case with a circular flat piezoelectric actuator fixed at the bottom and a core-shell lens (with a stainless steel core and a polymer shell) placed at the probe's conical tip. The core-shell lens is responsible to superfocusing effect of ultrasonic waves. Operating at approximately 3 MHz, the transverse and axial resolution for C- and B-scan images are, respectively, 0.65λ and 3λ/2 , with the wavelength being [Formula: see text]. The system depth-of-field is 6.3λ . To demonstrate the transducer capability to resolve subwavelength structures, we successfully obtain images of a copper wire forming a Y-intersection, whose branches a diameter similar to human hair ( [Formula: see text]). Our results represent a solid step toward the development of ultrasonic superresolution transducer applied for biomedical imaging and shallow NDT of materials.


Asunto(s)
Transductores , Ultrasonido , Humanos , Ultrasonografía
11.
IEEE Trans Biomed Eng ; 68(1): 68-77, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32356735

RESUMEN

OBJECTIVE: Nanotheranostic systems integrate therapeutic and diagnostic procedures using nanotechnology. This type of approach has enabled the development of methods for early detection and treatment of different pathologies. Magnetic hyperthermia (MH) has been proposed as an alternative or complementary method of cancer therapy. However, challenges such as delivering and localizing the magnetic nanoparticles (MNPs) within tissues and monitoring the temperature during the treatment hinder this technique to be effectively translated into a clinical routine. Therefore, in this study a theranostic platform has been proposed and examined to address two main issues, localizing MNPs and real-time temperature monitoring, for preclinical MH. METHODS: The system integrates magnetomotive (MMUS) and thermal ultrasound imaging with MH. An ultrasound device was used to acquire MMUS images to detect MNPs, and ultrasound thermometry to monitor the temperature. This platform was designed such that a single coil generated the magnetic field for MMUS and MH. The feasibility of the system was examined using a tissue mimicking phantom containing an inclusion filled with zinc substituted magnetite NPs. RESULTS: These MNPs were effectively used as contrast agent for MMUS and to generate heat during MH. In addition to localizing MNPs, real-time two-dimensional temperature maps were obtained with substantial concordance (ρc > 0.97) with invasive measurements using fiber optic thermometer. The heating rate was proportional to the displacements in MMUS (r = 0.92). CONCLUSION: Ultrasound thermometry was successfully used to monitor the temperature during MH. In addition, it was shown that acquiring MMUS images prior to MH can qualitatively predict the temperature distribution of the MNP-laden regions.


Asunto(s)
Hipertermia Inducida , Nanopartículas de Magnetita , Humanos , Hipertermia , Fenómenos Magnéticos , Medicina de Precisión , Ultrasonografía
12.
Biomed Phys Eng Express ; 7(6)2021 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-34496358

RESUMEN

Styrene-ethylene/butylene-styrene (SEBS) copolymer-in-mineral oil gel is an appropriate tissue-mimicking material to manufacture stable phantoms for ultrasound and photoacoustic imaging. Glycerol dispersion has been proposed to further tune the acoustic properties and to incorporate hydrophilic additives into SEBS gel. However, this type of material has not been investigated to produce wall-less vascular flow phantom for these imaging modalities. In this paper, the development of a wall-less vascular phantom for ultrasound and photoacoustic imaging is reported. Mixtures of glycerol/TiO2-in-SEBS gel samples were manufactured at different proportions of glycerol (10%, 15%, and 20%) and TiO2(0% to 0.5%) to characterize their optical and acoustic properties. Optical absorption in the 500-950 nm range was independent of the amount of glycerol and TiO2, while optical scattering increased linearly with the concentration of TiO2. Acoustic attenuation and speed of sound were not influenced by the presence of TiO2. The sample manufactured using weight percentages of 10% SEBS, 15% glycerol, and 0.2% TiO2was selected to make the vascular phantom. The phantom proved to be stable during the pulsatile blood-mimicking fluid (BMF) flow, without any observed damage to its structure or leaks. Ultrasound color Doppler images showed a typical laminar flow, while the B-mode images showed a homogeneous speckled pattern due to the presence of the glycerol droplets in the gel. The photoacoustic images of the phantom showed a well-defined signal coming from the surface of the phantom and from the vessels where BMF was flowing. The Spearman's correlations between the photoacoustic and tabulated spectra calculated from the regions containing BMF, in this case a mixture of salt solutions (NiCl2and CuSO4), were higher than 0.95. Our results demonstrated that glycerol-in-SEBS gel was an adequate material to make a stable vascular flow phantom for ultrasound photoacoustic imaging.


Asunto(s)
Técnicas Fotoacústicas , Glicerol , Fantasmas de Imagen , Estirenos , Ultrasonografía
13.
Ultrasound Med Biol ; 47(2): 334-344, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33131928

RESUMEN

The mechanical properties of biological tissues are fingerprints of certain pathologic processes. Ultrasound systems have been used as a non-invasive technique to both induce kilohertz-frequency mechanical vibrations and detect waves resulting from interactions with biological structures. However, existing methodologies to produce kilohertz-frequency mechanical vibrations using ultrasound require the use of variable-frequency, dual-frequency and high-power systems. Here, we propose and demonstrate the use of bursts of megahertz- frequency acoustic radiation to observe kilohertz-frequency mechanical responses in biological tissues. Femoral bones were obtained from 10 healthy mice and 10 mice in which osteoporosis had been induced. The bones' porosity, trabecular number, trabecular spacing, connectivity and connectivity density were determined using micro-computed tomography (µCT). The samples were irradiated with short, focused acoustic radiation pulses (f = 3.1 MHz, t = 15 µs), and the low-frequency acoustic response (1-100 kHz) was acquired using a dedicated hydrophone. A strong correlation between the spectral maps of the acquired signals and the µCT data was found. In a subsequent evaluation, soft tissue stiffness measurements were performed with a gel wax-based tissue-mimicking phantom containing three spherical inclusions of the same type of gel but different densities and Young's moduli, yet with approximately the same echogenicity. Conventional B-mode ultrasound was unable to image the inclusions, while the novel technique proposed here showed good image contrast.


Asunto(s)
Fémur/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Ondas Ultrasónicas , Ultrasonografía/métodos , Animales , Hueso Esponjoso/diagnóstico por imagen , Módulo de Elasticidad , Ratones , Fantasmas de Imagen , Porosidad , Sonido , Microtomografía por Rayos X
14.
Int J Nanomedicine ; 15: 8075-8095, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33116519

RESUMEN

PURPOSE: Sonodynamic therapy (SDT) is a new therapeutic modality for the noninvasive cancer treatment based on the association of ultrasound and sonosensitizer drugs. Topical SDT requires the development of delivery systems to properly transport the sonosensitizer, such as zinc phthalocyanine (ZnPc), to the skin. In addition, the delivery system itself can participate in sonodynamic events and influence the therapeutic response. This study aimed to develop ZnPc-loaded micelle to evaluate its potential as a topical delivery system and as a cavitational agent for low-frequency ultrasound (LFU) application with the dual purpose of promoting ZnPc skin penetration and generating reactive oxygen species (ROS) for SDT. METHODS: ZnPc-loaded micelles were developed by the thin-film hydration method and optimized using the Quality by Design approach. Micelles' influence on LFU-induced cavitation activity was measured by potassium iodide dosimeter and aluminum foil pits experiments. In vitro skin penetration of ZnPc was assessed after pretreatment of the skin with LFU and simultaneous LFU treatment using ZnPc-loaded micelles as coupling media followed by 6 h of passive permeation of ZnPc-loaded micelles. The singlet oxygen generation by LFU irradiation of the micelles was evaluated using two different hydrophilic probes. The lipid peroxidation of the skin was estimated using the malondialdehyde assay after skin treatment with simultaneous LFU using ZnPc-loaded micelles. The viability of the B16F10 melanoma cell line was evaluated using resazurin after treatment with different concentrations of ZnPc-loaded micelles irradiated or not with LFU. RESULTS: The micelles increased the solubility of ZnPc and augmented the LFU-induced cavitation activity in two times compared to water. After 6 h ZnPc-loaded micelles skin permeation, simultaneous LFU treatment increased the amount of ZnPc in the dermis by more than 40 times, when compared to non-LFU-mediated treatment, and by almost 5 times, when compared to LFU pretreatment protocol. The LFU irradiation of micelles induced the generation of singlet oxygen, and the lipoperoxidation of the skin treated with the simultaneous LFU was enhanced in three times in comparison to the non-LFU-treated skin. A significant reduction in cell viability following treatment with ZnPc-loaded micelles and LFU was observed compared to blank micelles and non-LFU-treated control groups. CONCLUSION: LFU-irradiated mice can be a potential approach to skin cancer treatment by combining the functions of increasing drug penetration and ROS generation required for SDT.


Asunto(s)
Indoles/farmacología , Micelas , Compuestos Organometálicos/farmacología , Ultrasonido , Aluminio/química , Animales , Supervivencia Celular/efectos de los fármacos , Humanos , Isoindoles , Melanoma/tratamiento farmacológico , Melanoma/patología , Melanoma Experimental/patología , Fosfatidiletanolaminas/química , Fármacos Fotosensibilizantes/farmacología , Polietilenglicoles/química , Yoduro de Potasio/química , Oxígeno Singlete/química , Neoplasias Cutáneas/tratamiento farmacológico , Neoplasias Cutáneas/patología , Porcinos , Compuestos de Zinc
15.
Ultrasound Med Biol ; 46(8): 2070-2078, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32423572

RESUMEN

The acoustic properties of ultrasound phantom materials have always been important, but with new applications interrogating tissue mechanical properties, viscoelasticity has also become an interesting feature to consider. Along with Young's modulus, the viscous component of tissue is affected by certain diseases and can therefore be used as a biomarker. Furthermore, viscoelasticity varies between tissue types and individuals, and therefore it would be useful with a phantom material that reflects this physiological range. Here we describe a gel for ultrasound imaging with a range of mechanical properties given by mixing different ratios of two oil-based gels, clear ballistic and styrene-ethylene/butylene-styrene (SEBS). The gels were mixed in five different proportions, ranging from 0-100% of either gel. For each of the gel compositions, we measured time of flight to determine speed of sound, narrowband ultrasound transmission for attenuation, stress-relaxation for viscoelasticity, mass and volume. Analysis of the stress-relaxation data using the generalized Maxwell model suggests that the material can be described by five parameters, E0, E1, E2, η1 and η2, and that each of these parameters decreases as more SEBS is incorporated into the mixed material. Instantaneous Young's modulus (the sum of E0, E1 and E2 in our model) ranges between 49 and 117 kPa for the different ratios, similar to values reported for cancerous tissue. Despite the large span of obtainable mechanical properties, speed of sound is relatively constant regardless of composition, with mean value estimates (± 95 % CI) between 1438 ± 9 and 1455 ± 3 m/s for pure and mixed gels. This was attributed to a variation in density and Poisson's ratio, following from the relation linking them to speed of sound and elasticity. Furthermore, both speed of sound and attenuation were within a suitable range for ultrasound phantoms. Combining this ballistic gel with SEBS copolymer in oil allows for control of mechanical properties, both elastic and viscous as evaluated by the material model. Furthermore, it does so without compromising ease of use, longevity and safety of the pre-made gel.


Asunto(s)
Fantasmas de Imagen , Sonido , Ultrasonografía , Elasticidad , Polietilenos , Poliestirenos , Sustancias Viscoelásticas , Viscosidad
16.
Sci Rep ; 9(1): 18048, 2019 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-31792227

RESUMEN

Optimizing the intrinsic properties of magnetic nanoparticles for magnetic hyperthermia is of considerable concern. In addition, the heating efficiency of the nanoparticles can be substantially influenced by dipolar interactions. Since adequate control of the intrinsic properties of magnetic nanoparticles is not straightforward, experimentally studying the complex interplay between these properties and dipolar interactions affecting the specific loss power can be challenging. Substituting zinc in magnetite structure is considered as an elegant approach to tune its properties. Here, we present experimental and numerical simulation results of magnetic hyperthermia studies using a series of zinc-substituted magnetite nanoparticles (ZnxFe1-xFe2O4, x = 0.0, 0.1, 0.2, 0.3 and 0.4). All experiments were conducted in linear regime and the results were inferred based on the numerical simulations conducted in the framework of the linear response theory. The results showed that depending on the nanoparticles intrinsic properties, interparticle interactions can have different effects on the specific loss power. When dipolar interactions were strong enough to affect the heating efficiency, the parameter σ = KeffV/kBT (Keff is the effective anisotropy and V the volume of the particles) determined the type of the effect. Finally, the sample x = 0.1 showed a superior performance with a relatively high intrinsic loss power 5.4 nHm2kg-1.

17.
Rev Sci Instrum ; 90(7): 074701, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31370463

RESUMEN

In recent decades, magnetic hyperthermia using magnetic nanoparticles, a promising but quite challenging method, has proven to be an effective cancer therapy procedure. In hyperthermia, heat, which is generated by magnetic nanoparticles exposed to a radiofrequency magnetic field, is employed to battle cancerous cells. Ideally, devices for magnetic hyperthermia should provide a variety of field amplitudes and frequencies for generating an appropriate and powerful alternating magnetic field. Here, we report the design and evaluation of a versatile system which provides different experimental setup possibilities for magnetic hyperthermia. The proposed system is a derivative of the Mazzilli inverter, which directly follows the resonant frequency of the LC tank circuit independent of its component. The feasibility of the system for hyperthermia studies was examined using iron oxide nanoparticles prepared by the coprecipitation method. Different experimental conditions including nanoparticles in solution and dispersed in gelatin phantoms were evaluated. Four different coils including two solenoids, a pancake, and a Helmholtz-like format were successfully tested. Using these coils, 18 different operation frequencies in the frequency band of 63-530 kHz with field strengths up to 27.2 kA/m were achieved.


Asunto(s)
Hipertermia Inducida/instrumentación , Campos Magnéticos , Estudios de Factibilidad , Compuestos Férricos/química , Nanopartículas
18.
Phys Med Biol ; 64(21): 215019, 2019 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-31539896

RESUMEN

The shear wave dispersion magneto-motive ultrasound (SDMMUS) method was recently developed to analyze the mechanical properties of a viscoelastic medium. This technique is based on the interaction of magnetic nanoparticles (MNPs) with an external magnetic field to generate a shear wave within the medium labeled with MNPs. The propagation of this wave provides information about the viscoelastic properties of the medium. In a previous work by Arsalani et al (2018), magnetite NPs were synthesized by a co-precipitation method and coated with natural rubber latex (NRL). In order to investigate the effect of NRL on the size and magnetization of MNPs, varying amounts of NRL (zero, 100 µl, and 800 µl of a stock solution of NRL) were used during the synthesis process. The results showed that MNPs prepared with 800 µl of NRL, named as MNPs-800NRL, had the smallest size and highest magnetization. In the present paper, the main objective is to investigate whether MNPs-800NRL, having the highest magnetization, is also the best option for SDMMUS experiments among others. All experiments were performed using gelatin tissue-mimicking phantoms labeled with the aforementioned MNPs. The two factors of core size and magnetization were considered, and based on the observed results, the effect of magnetization was more prominent than that of the core size on the induced displacements. MNPs coated with a thicker NRL shell, having the highest magnetization value, enhanced the sensitivity and the signal to noise ratio in SDMMUS. Various concentrations of these optimized MNPs were also examined, to investigate the lowest possible concentration for observing shear waves in the SDMMUS technique.


Asunto(s)
Látex/química , Fenómenos Magnéticos , Nanopartículas de Magnetita/química , Goma/química , Ondas Ultrasónicas , Gelatina
19.
IEEE Trans Med Imaging ; 38(2): 561-571, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30207951

RESUMEN

As photoacoustic (PA) imaging makes its way into the clinic, the accuracy of PA-based metrics becomes increasingly important. To address this need, a method combining finite-element-based local fluence correction (LFC) with signal-to-noise-ratio (SNR) regularization was developed and validated to accurately estimate oxygen saturation (SO2) in tissue. With data from a Vevo LAZR system, performance of our LFC approach was assessed in ex vivo blood targets (37.6%-99.6% SO2) and in vivo rat arteries. Estimation error of absolute SO2 and change in SO2 reduced from 10.1% and 6.4%, respectively, without LFC to 2.8% and 2.0%, respectively, with LFC, while the accuracy of the LFC method was correlated with the number of wavelengths acquired. This paper demonstrates the need for an SNR-regularized LFC to accurately quantify SO2 with PA imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Oxígeno/sangre , Técnicas Fotoacústicas/métodos , Animales , Análisis de Elementos Finitos , Arteria Hepática/diagnóstico por imagen , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Masculino , Ratas , Relación Señal-Ruido , Ultrasonografía/métodos
20.
Ultrasound Med Biol ; 43(9): 2086-2094, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28648918

RESUMEN

Phantoms are important tools for image quality control and medical training. Many phantom materials have been proposed for ultrasound; most of them use water as the solvent, but these materials have disadvantages such as dehydration and low temporal stability if not properly stored. To overcome these difficulties, copolymer-in-oil gel was proposed as an inert and stable material; however, speed of sound for these materials is still lower than what is described for most biological tissues. Here, we propose the glycerol dispersion in oil-based gels to modify the acoustic and elastic properties of copolymer-in-oil phantoms. We manufactured copolymer-in-oil gels using styrene-ethylene/butylene-styrene (SEBS) in concentrations 8%-15%. We used 2 types of mineral oils with different viscosities. Glycerol was added in a volume fraction 0%-30% of the total amount of liquid. The acoustic (i.e., speed of sound, attenuation and backscattering) and the mechanical (i.e., density and Young's modulus) properties of the samples were within the range of values observed for soft tissues. The acoustic parameters of the samples were dependent on oil viscosity and glycerol concentration. The speed of sound ranged 1423 m/s - 1502 m/s, while the acoustic attenuation and the ultrasonic backscattering increased by adding glycerol. The density and the Young's moduli were less affected by the presence of glycerol. We conclude that glycerol can be used to control the acoustic parameters of copolymer-in-oil gels. Additionally, it opens the possibility of incorporating other oil-insoluble substances to control further properties of the phantom.


Asunto(s)
Geles , Glicerol , Fantasmas de Imagen , Ultrasonografía/métodos , Acústica , Módulo de Elasticidad , Elasticidad , Diseño de Equipo
SELECCIÓN DE REFERENCIAS