Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Am Nat ; 198(3): 347-359, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34403314

RESUMEN

AbstractThe leaf economics spectrum ranges from cheap, short-lived leaves to expensive, long-lived leaves. Species with low leaf mass per area (LMA) and short leaf life span tend to be fast growing and shade intolerant (early successional), whereas species with high LMA and long leaf life span tend to be slow growing and shade tolerant (late successional). However, we have limited understanding of how different leaf mass components (e.g., metabolically active photosynthetic components vs. structural toughness components) contribute to variation in LMA and other leaf economics spectrum traits. Here, we develop a model of plant community dynamics in which species differ in just two traits, photosynthetic and structural LMA components, and we identify optimal values of these traits for early- and late-successional species. Most of the predicted increase in LMA from early- to late-successional species was due to structural LMA. Photosynthetic LMA did not differ consistently between early- and late-successional species, but the photosynthetic LMA to structural LMA ratio declined from early- to late-successional species. Early-successional species had high rates of instantaneous return on leaf mass investment, whereas late-successional species had high lifetime return. Our results provide theoretical support for the primary role of structural (rather than photosynthetic) LMA variation in driving relationships among leaf economics spectrum traits.


Asunto(s)
Hojas de la Planta , Plantas , Fenotipo , Fotosíntesis
2.
IEEE J Transl Eng Health Med ; 12: 314-327, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38486844

RESUMEN

The longevity of current joint replacements is limited by aseptic loosening, which is the primary cause of non-infectious failure for hip, knee, and ankle arthroplasty. Aseptic loosening is typically caused either by osteolysis from particulate wear, or by high shear stresses at the bone-implant interface from over-constraint. Our objective was to demonstrate feasibility of a compliant intramedullary stem that eliminates over-constraint without generating particulate wear. The compliant stem is built around a compliant mechanism that permits rotation about a single axis. We first established several models to understand the relationship between mechanism geometry and implant performance under a given angular displacement and compressive load. We then used a neural network to identify a design space of geometries that would support an expected 100-year fatigue life inside the body. We additively manufactured one representative mechanism for each of three anatomic locations, and evaluated these prototypes on a KR-210 robot. The neural network predicts maximum stress and torsional stiffness with 2.69% and 4.08% error respectively, relative to finite element analysis data. We identified feasible design spaces for all three of the anatomic locations. Simulated peak stresses for the three stem prototypes were below the fatigue limit. Benchtop performance of all three prototypes was within design specifications. Our results demonstrate the feasibility of designing patient- and joint-specific compliant stems that address the root causes of aseptic loosening. Guided by these results, we expect the use of compliant intramedullary stems in joint reconstruction technology to increase implant lifetime.


Asunto(s)
Artroplastia de Reemplazo , Humanos , Interfase Hueso-Implante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA