Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Kidney Int ; 104(1): 189-200, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36990214

RESUMEN

Use of a covered stent after percutaneous transluminal angioplasty (PTA) was compared to PTA alone for treatment of upper extremity hemodialysis patients with arteriovenous fistula (AVF) stenoses. Patients with AVF stenosis of 50% or more and evidence of AVF dysfunction underwent treatment with PTA followed by randomization of 142 patients to include a covered stent or 138 patients with PTA alone. Primary outcomes were 30-day safety, powered for noninferiority, and six-month target lesion primary patency (TLPP), powered to test whether TLPP after covered-stent placement was superior to PTA alone. Twelve-month TLPP and six-month access circuit primary patency (ACPP) were also hypothesis tested while additional clinical outcomes were observed through two years. Safety was significantly non-inferior while six- and 12-month TLPP were each superior for the covered stent group compared to PTA alone (six months: 78.7% versus 55.8%; 12 months: 47.9% versus 21.2%, respectively). ACPP was not statistically different between groups at six-months. Observed differences at 24 months favored the covered-stent group: 28.4% better TLPP, fewer target-lesion reinterventions (1.6 ± 1.6 versus 2.8 ± 2.0), and a longer mean time between target-lesion reinterventions (380.4 ± 249.5 versus 217.6 ± 158.4 days). Thus, our multicenter, prospective, randomized study of a covered stent used to treat AVF stenosis demonstrated noninferior safety with better TLPP and fewer target-lesion reinterventions than PTA alone through 24 months.


Asunto(s)
Angioplastia de Balón , Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Humanos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Grado de Desobstrucción Vascular , Constricción Patológica/etiología , Angioplastia de Balón/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Derivación Arteriovenosa Quirúrgica/efectos adversos , Angioplastia/efectos adversos , Stents , Fístula Arteriovenosa/etiología , Diálisis Renal/efectos adversos
2.
Eur Spine J ; 32(1): 8-19, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35835893

RESUMEN

PURPOSE: Abdominal aortic aneurysms (AAAs) affect the vascular perfusion of the lumbar spine. The treatment of AAAs with endovascular aortic aneurysm repair (EVAR) completely occludes the direct vascular supply to the lumbar spine. We hypothesized that patients with AAA who undergo EVAR show a different pattern of spinal degeneration than individuals without AAA. METHODS: In this retrospective institutional review board-approved study, 100 randomly selected patients with AAA who underwent EVAR with computed tomography (CT) scans between 2005 and 2017 were compared with age- and gender-matched controls without AAA. In addition, long-term follow-up CT images (> 6 months before EVAR, at the time of EVAR, and > 12 months after EVAR) of the patients were analysed to compare the progression of degeneration from before to after EVAR. Degeneration scores, lumbar levels with the most severe degeneration, and lumbar levels with progressive degeneration were analysed in all CT images. Fisher's exact test, Wilcoxon signed-rank test, and Mann-Whitney U test were performed for statistical analyses. RESULTS: Compared with the control group (n = 94), the most severe degeneration was more commonly detected in the mid-lumbar area in the patient group (n = 100, p = 0.016), with significantly more endplate erosions being detected in the lumbar spine (p = 0.015). However, EVAR did not result in significant additional acceleration of the degenerative process in the long-term follow-up analysis (n = 51). CONCLUSION: AAA is associated with atypical, more cranially located spinal degradation, particularly in the mid-lumbar segments; however, EVAR does not seem to additionally accelerate the degenerative process. This observation underlines the importance of disc and endplate vascularization in the pathomechanism of spinal degeneration. LEVEL OF EVIDENCE I: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.


Asunto(s)
Aneurisma de la Aorta Abdominal , Procedimientos Endovasculares , Humanos , Estudios Retrospectivos , Estudios Transversales , Procedimientos Quirúrgicos Vasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/epidemiología , Aneurisma de la Aorta Abdominal/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/métodos , Factores de Riesgo
3.
Transfus Med Hemother ; 50(3): 226-233, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37434998

RESUMEN

Introduction: Postpartum hemorrhage (PPH) is the leading cause of peripartal maternal mortality and accounts for 25% of all maternal deaths worldwide. The most common reasons of PPH are uterine atony, retained placenta, or placenta accreta spectrum. Treatment of PPH depends on the etiology and corresponds to a stepwise approach, which follows the German, Austrian and Swiss guideline for the diagnosis and therapy of PPH in Switzerland. In severe ongoing PPH, hysterectomy has been the ultima ratio for many decades. Nowadays, interventional embolization of the pelvic arteries (PAE) has become a popular alternative. Besides being a highly effective minimally invasive method, PAE avoids hysterectomy with consecutively reduced morbidity and mortality. However, data on the long-term effects of PAE on fertility and menstrual cycle are scarce. Methods: We performed a monocentric study consisting of a retro- and a prospective part including all women who had undergone a PAE between 2012 and 2016 at University Hospital Zurich. Descriptive characteristics of patients and efficacy of PAE defined as cessation of bleeding were analyzed retrospectively. In the prospective part, all patients were contacted for a follow-up questionnaire regarding menstruation and fertility after embolization. Results: Twenty patients with PAE were evaluated. Our data showed a success rate of PAE in 95% of patients with PPH; only 1 patient needed a second, then successful, PAE. No patient needed a hysterectomy or any other surgical intervention. In our study, an association between mode of delivery and identified etiology of PPH is observed. After spontaneous delivery (n = 6), the main reason of severe PPH was retained placenta (n = 4), while after cesarean section (n = 14), uterine atony was identified in most cases (n = 8). Regarding menstruation after embolization, all women reported regular menstruation after the breastfeeding period (100%). The majority reported a regular pattern with a shorter or similar duration (73%) and lower or similar intensity (64%). Dysmenorrhea decreased in 67% of patients. Four patients planned another pregnancy, of whom only one had become pregnant with assisted reproductive technology and ended up in a miscarriage. Discussion: Our study confirms the efficacy of PAE in PPH, thus obviating complex surgical interventions and associated morbidity. The success of PAE does not depend on the primary cause of PPH. Our results may encourage the prompt decision to perform PAE in the management of severe PPH in case of failure of conservative management and help physicians in the post-interventional counseling regarding menstruation patterns and fertility.

4.
J Vasc Interv Radiol ; 32(9): 1377-1385, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34462082

RESUMEN

The purpose of this study was to evaluate the feasibility of recanalization of chronic noncirrhotic, nonmalignant splanchnic thromboses with a transsplenic assisted patient-tailored approach with or without transjugular intrahepatic portosystemic shunt (TIPS) creation. In this retrospective study, 10 patients (median age, 48.4 years; interquartile range, 5.1 years) underwent revascularization between November 2016 and August 2020. Portal cavernoma was present in all patients, with complete splenic vein thrombosis in 70%. The technical success rate was 80%. Additional TIPS creation was performed in 5 (50%) patients. At a median follow-up of 19.3 months (interquartile range, 17.9 months), the primary and secondary patency rate was 70% and 100%, respectively. During follow-up, 1 patient died due to recurrent upper gastrointestinal variceal hemorrhage. In conclusion, percutaneous transsplenic assisted recanalization of chronic noncirrhotic, nonmalignant splanchnic thromboses is feasible. However, multiple access points may still be needed. Additional TIPS creation appears to be necessary only in case of insufficient portal venous flow into the liver.


Asunto(s)
Várices Esofágicas y Gástricas , Derivación Portosistémica Intrahepática Transyugular , Trombosis , Adulto , Hemorragia Gastrointestinal , Humanos , Persona de Mediana Edad , Vena Porta/diagnóstico por imagen , Vena Porta/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Vasc Interv Radiol ; 31(5): 754-758, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32359522

RESUMEN

This brief report describes 3 patients with infected extrahepatic splanchnic venous stents or stent grafts. These devices had been placed to treat prehepatic portal hypertension 4 wk, 3 mo, and 31 mo, respectively, before readmission for fever. Blood cultures and fluorine-18 fludeoxyglucose positron emission tomography/CT were positive in all. With systemic antibiotic treatment, 2 patients showed a clinical recovery. In the third patient, antibiotic treatment failed. Therefore, the infected stent graft was surgically removed and a splenorenal shunt was created. No recurrent splanchnic venous infection was observed in these 3 patients.


Asunto(s)
Antibacterianos/administración & dosificación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/instrumentación , Hipertensión Portal/cirugía , Infecciones Relacionadas con Prótesis/terapia , Stents/efectos adversos , Resultado del Tratamiento , Adolescente , Anciano , Implantación de Prótesis Vascular/efectos adversos , Remoción de Dispositivos , Procedimientos Endovasculares/efectos adversos , Humanos , Hipertensión Portal/diagnóstico , Hipertensión Portal/fisiopatología , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Presión Portal , Tomografía Computarizada por Tomografía de Emisión de Positrones , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos , Circulación Esplácnica
6.
J Vasc Interv Radiol ; 31(4): 551-557, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31882302

RESUMEN

PURPOSE: To analyze and correlate preinterventional magnetic resonance (MR) imaging findings with clinical symptoms after percutaneous sclerotherapy of venous malformations (VMs) adjacent to the knee. MATERIALS AND METHODS: Twenty-five patients (mean age, 24 y; range, 7-55 y; 11 female) with 26 VMs adjacent to the knee undergoing sclerotherapy (direct puncture, diagnostic angiography, sclerosant injection) were identified, and MR imaging findings were analyzed. The VM involved the synovium of the knee joint in 19 of 26 cases (76%). These lesions were associated with joint effusion (3 of 19; 16%), hemarthrosis (4 of 19; 21%), or synovial thickening (16 of 19; 84%). Follow-up ended 6-8 weeks after the first or second sclerotherapy session if complete pain relief was achieved or 3 months after the third sclerotherapy session. Treatment outcomes were categorized as symptom improvement (complete or partial pain relief) or poor response (unchanged or increased pain). RESULTS: Forty-nine percutaneous sclerotherapy sessions were performed. Despite the absence of signs of knee osteoarthritis, patients with a VM involving the synovium (8 of 14; 57%) showed a poor response to sclerotherapy (1 of 8 [13%] pain-free after 1 sclerotherapy session). Among patients with VMs with no associated joint alteration and no synovial involvement (6 of 14; 43%), 5 of 6 (83%) showed improvement of symptoms after 1 sclerotherapy session (P < .05). CONCLUSIONS: Juxta-articular VMs of the knee are frequently associated with hemarthrosis and synovial thickening. Patients with signs of osteoarthritis and synovial involvement of the VM on presclerotherapy MR imaging deserve special consideration, as these findings predict worse clinical symptoms after sclerotherapy.


Asunto(s)
Rodilla/irrigación sanguínea , Imagen por Resonancia Magnética , Soluciones Esclerosantes/administración & dosificación , Escleroterapia , Membrana Sinovial/irrigación sanguínea , Malformaciones Vasculares/terapia , Venas/diagnóstico por imagen , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Soluciones Esclerosantes/efectos adversos , Escleroterapia/efectos adversos , Resultado del Tratamiento , Malformaciones Vasculares/diagnóstico por imagen , Venas/anomalías , Adulto Joven
7.
Ann Plast Surg ; 85(4): 407-412, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32000251

RESUMEN

OBJECTIVE: This study aimed to determine the benefits of sclerotherapy with OK-432 for the treatment of postoperative chronic lymphocele. BACKGROUND: Postoperative chronic lymphocele formation is common and accounts for a high postoperative morbidity. Nonsurgical strategies comprise repetitive percutaneous fluid aspiration or percutaneous sclerotherapy. OK-432 has been used to treat congenital lymphatic malformations with several reports of promising results. We hypothesized that it is more beneficial than repetitive percutaneous fluid aspiration for the treatment of symptomatic lymphocele. METHODS: Two cohorts of melanoma patients who developed recurrent lymphocele after lymph node dissection from January 2013 to August 2017 were compared. The first cohort was treated with repetitive percutaneous fluid aspiration (n = 20). The second cohort received OK-432 sclerotherapy (n = 20). Primary end points were overall treatment duration, number of treatment sessions, and the clinical success in both cohorts. Secondary end points were surgical site infection rate, need for additional antibiotic treatment, wound healing disorders, and the need for revision surgery. RESULTS: Mean overall duration of treatment with sclerotherapy was significantly shorter than with repetitive aspiration (9.4 ± 7.2 vs 47.5 ± 31.9 days, P < 0.01). Mean number of sclerotherapy treatment sessions were 2.5 ± 1.2. Clinical success with OK-432 was 19 of 20, and that with repeated aspiration was 7 of 20 (χ = 15.82, P < 0.001). No surgical site infection occurred in the sclerotherapy cohort, which was significantly lower than those treated with repetitive aspiration (P < 0.03). Surgical revision was mandatory in 12 of 20 patients who were treated with repetitive aspiration, and only 1 of 20 patients in the sclerotherapy cohort. CONCLUSION: Sclerotherapy with OK-432 for the treatment of postoperative lymphocele is highly beneficial with a significant reduction of morbidity and the overall treatment time compared with repetitive aspiration.


Asunto(s)
Linfocele , Picibanil , Escleroterapia , Estudios de Cohortes , Humanos , Escisión del Ganglio Linfático , Linfocele/etiología , Linfocele/terapia , Picibanil/uso terapéutico , Estudios Retrospectivos
8.
Vasa ; 49(1): 39-42, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31549917

RESUMEN

Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath and J-tip wire with pigtail catheter are retracted until the CLG opening level, maintaining the stiff "buddy" wire in position to support the 12 fr sheath, maintaining its distal opening close to the contralateral gate opening to achieve easy cannulation. Results: Retrospective analysis of video archive from July 2016 to February 2018 evidenced 55 recorded EVAR cases. All CLG cannulations were obtained with Standard J-tip or Terumo Glidewire wires and with Pig-Tail or Berenstein catheters. Technical success was 100 %. Mean fluoroscopy time to accomplish CLG cannulation was 37.6 33 (range 1-105) seconds. The aortic carrefour angulation on coronal axis strongly correlates with cannulation time p = <.001, with longer cannulation time for higher carrefour angulations on coronal axis (Pearson correlation coefficient 0.47). Conclusions: The use of 12 fr sheath with parallel wire introduction technique, appears to be a safe and reliable tool to facilitate CLG cannulation during EVAR procedures.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Prótesis Vascular , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
9.
Radiol Med ; 125(10): 971-980, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32270335

RESUMEN

PURPOSE: Quantification of post-interventional adverse events of outpatient SIRT leading to hospitalization and quantification of radiation exposure. MATERIALS AND METHODS: In this single-center, retrospective cohort study, we reviewed 212 patients treated with SIRT (90Y-microspheres) for primary and secondary liver malignancies. We searched for adverse events (AEs) and serious adverse events (SAEs), defined as AE's causing hospitalization. Additionally, radiation exposure was measured in 36 patients. RESULTS: Seven patients had an SAE (3.3%), four patients had AE without readmission/hospitalization (1.9%) and 201 patients had no complications (94.8%). The mean ambient dose rate at 1 m distance from the source after administration of 90Y-microspheres was 1.88 µSv/h ± 0.74 (± SD) with a range from 4.3 to 0.2 µSv/h. CONCLUSION: Outpatient radioembolization with 90Y-microspheres is safe and requires hospitalization only in a very small number of patients. The mean dose rate was low and met the national conditions for outpatient treatment (< 5 µSv/h).


Asunto(s)
Atención Ambulatoria , Embolización Terapéutica/métodos , Hospitalización , Neoplasias Hepáticas/terapia , Microesferas , Radioisótopos de Itrio/administración & dosificación , Angiografía , Embolización Terapéutica/efectos adversos , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Exposición a la Radiación/análisis , Neumonitis por Radiación/prevención & control , Estudios Retrospectivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio/efectos adversos
10.
Ther Umsch ; 77(2): 53-56, 2020.
Artículo en Alemán | MEDLINE | ID: mdl-32633228

RESUMEN

Diagnosis and Minimal Invasive Treatment of Benign Prostatic Hyperplasia Abstract. Benign prostatic hyperplasia (BPH) is a common condition in men aged 50 - 60 years with a prevalence of about 50 %. After failure of conservative treatment, the standard treatment of BPH is transurethral resection of the prostate (TURP). However, over the last years prostatic artery embolization (PAE) emerged as a minimal invasive alternative to treat lower urinary tract symptoms. After patient assessment by MRI and CT of the prostate to rule out possible contraindications of PAE, the procedure can be performed in an outpatient setting under local anesthesia by an interventional radiologist. Especially for frail patients and / or patients with special risks regarding surgery / anesthesia, PAE may be an alternative to TURP with fewer complications.


Asunto(s)
Embolización Terapéutica , Síntomas del Sistema Urinario Inferior/diagnóstico , Síntomas del Sistema Urinario Inferior/etiología , Síntomas del Sistema Urinario Inferior/terapia , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/cirugía , Hiperplasia Prostática/terapia , Resección Transuretral de la Próstata , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
11.
Ther Umsch ; 77(2): 57-61, 2020.
Artículo en Alemán | MEDLINE | ID: mdl-32633227

RESUMEN

Endometriosis Abstract. Endometriosis, which is the presence of functional endometrial tissue outside the endometrium, represents one of the most common gynecological diseases. Given the variability of the symptoms depending on the exact localization of the disease, it is not uncommon for a patient to be diagnosed only after approximately 10 years of suffering. Localizations of the disease can include the typical endometrioma of the ovaries and in particular the lesser pelvis (e. g., fallopian tubes, uterine ligaments). It is then termed "deep pelvic endometriosis" and may be the reason for scarring, chronic pelvic pain and infertility. MRI has become increasingly popular in assessing the extent of the disease, due to its increasing availability and excellent soft tissue contrast. Recently, European guidelines have been published to better standardize technical MRI parameters and reporting, in addition to several scoring systems (e. g., the ENZIAN score), which have been established in the past. This allows for a precise localization of the disease and may guide surgical management in advanced cases. Other therapeutic options - depending on the severity of the symptoms - include pain medication or hormonal treatments. In the case of adenomyosis, the embolization of the uterine arteries as a minimally invasive approach has demonstrated excellent results.


Asunto(s)
Endometriosis/diagnóstico , Endometriosis/terapia , Femenino , Humanos , Imagen por Resonancia Magnética , Dolor Pélvico/terapia , Pelvis
12.
Radiology ; 291(2): 531-538, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30835189

RESUMEN

Background Optimal timing of the CT scan relative to the contrast media bolus remains a challenging task given the shorter scan durations of modern CT scanners, as well as interpatient variability. Purpose To compare contrast opacification in CT angiography of the aorta between a cohort with fixed trigger delay and a cohort with patient-specific individualized trigger delay for contrast media timing with bolus tracking. Materials and Methods In this prospective study (January-August 2018), CT angiography of the thoracoabdominal aorta with bolus tracking was performed in two different study cohorts: one with a fixed trigger delay of 4 seconds (fixed cohort) and one with a patient-specific trigger delay (individualized cohort). All CT and contrast media protocol parameters were kept identical among cohorts. Objective image quality was evaluated by one reader; two readers assessed subjective image quality. Student t test was used to test for differences in mean attenuation; the Wilcoxon-Mann-Whitney test was used to test for differences in noise, contrast-to-noise ratio, and subjective image quality. Results The fixed cohort had 108 study participants (16 women; mean age ± standard deviation, 72 years ± 10); the individualized cohort had 108 participants (16 women; mean age, 72 years ± 12). The trigger delay in the individualized cohort ranged from 6.4-11.3 seconds (mean, 9.2 seconds). There was higher overall attenuation in the individualized cohort than in the fixed cohort (486 HU ± 92 for individualized vs 438 HU ± 99 for fixed; P < .001), with increasing differences from the aortic arch (8 HU) to the iliac arteries (95 HU). The regression model indicated uniform attenuation in the individualized cohort and decreasing attenuation in the fixed cohort (decrease of 87 HU by the iliac arteries; P < .001). There was no difference between cohorts for image noise (20 vs 19; P = .41), but contrast-to-noise ratio (21 vs 19; P = .04) and subjective image quality were higher in the individualized cohort than in the fixed cohort (excellent or good image quality, 100% vs 67%; P < .001). Conclusion Compared with a fixed delay time after bolus tracking, a patient-specific individualized trigger delay improves image quality and provides uniform contrast attenuation for CT angiography of the aorta. ©RSNA, 2019.


Asunto(s)
Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Aortografía/métodos , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo
13.
J Endovasc Ther ; 26(6): 871-878, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31478457

RESUMEN

Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75±7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measured outcomes were PsR feasibility only in the first 4 patients and impact on operative performance thereafter (changes in device selection, the planning process, clinical outcomes, perioperative mortality, and complication rates). Technical metrics and timing of system setup, rehearsal, interval from patient arrival to the actual procedure, and eEVAR were recorded. Results: Mean time for 3D model creation was 21.3±7.8 minutes (range 13-37); there was a significant positive relationship between aortic neck diameter and segmentation time (p=0.003). The overall mean time for simulator setup and PsR was 54±14 minutes (range 37-80); PsR alone was completed in a mean 31±40 minutes (95% confidence interval -60 to -2.2). The actual eEVAR procedure duration was 69±16 minutes (range 45-90). No delay in the actual eEVAR procedure was registered owing to the PsR pathway. In 6 patients, preprocedure rehearsal induced changes in operative strategy, including device selection, main body introduction side, and/or deployment configuration. In 4 cases, rehearsal was performed twice to achieve optimal performance. Conclusion: PsR before eEVAR was feasible in all cases and caused no time delays in the actual eEVAR procedure. PsR optimized eEVAR planning by identifying optimal strategy for stent-graft component selection and deployment.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Modelación Específica para el Paciente , Cirugía Asistida por Computador , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Rotura de la Aorta/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Estudios de Factibilidad , Femenino , Humanos , Masculino , Modelos Anatómicos , Modelos Cardiovasculares , Tempo Operativo , Complicaciones Posoperatorias/etiología , Impresión Tridimensional , Diseño de Prótesis , Factores de Riesgo , Stents , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/mortalidad , Factores de Tiempo , Resultado del Tratamiento
14.
J Vasc Surg ; 68(1): 83-90.e2, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29602473

RESUMEN

OBJECTIVE: The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. METHODS: Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. RESULTS: In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. CONCLUSIONS: The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
Eur Radiol ; 28(1): 265-273, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28710583

RESUMEN

OBJECTIVE: To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. METHODS AND MATERIALS: Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. CONCLUSION: In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. KEY POINTS: • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/métodos , Femenino , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Masculino , Metales , Persona de Mediana Edad , Estudios Retrospectivos
16.
J Vasc Interv Radiol ; 29(12): 1725-1732, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30396844

RESUMEN

PURPOSE: To evaluate outcome of endovascular elective repair and repair of ruptured isolated iliac artery aneurysms (IIAAs) as a primary treatment strategy. MATERIALS AND METHODS: All patients with an IIAA undergoing endovascular treatment were included. Aneurysms were classified according to an anatomic classification and treated with coiling of the internal iliac artery, stent graft placement in the common to external iliac artery, or placement of a bifurcated aortoiliac stent graft. Between November 1996 and November 2015, 72 patients with 85 IIAAs underwent endovascular repair. Mean age was 73.9 years ± 9.2. Common iliac artery was involved in 63 patients (74.1%), internal iliac artery was involved in 21 patients (24.7%), and external iliac artery was involved in 1 patient (1.2%). Mean diameter was 5 cm (range, 2.5-11 cm). Emergency repair was performed in 19 patients owing to rupture (26.4%). RESULTS: Overall primary technical success rate was 95.8% with conversion rate to open surgery of 4.2% (all in the emergency group) and in-hospital mortality rate of 1.4%. During mean follow-up of 4.3 years ± 3.3 (median 3.8 y; range, 0-14.2 y), 17 endoleaks were observed (6 type I, 10 type II, 1 type IIIa). Overall reintervention rate was 16.7%. Primary patency rate was 98.6%. During the follow-up period, 22 deaths occurred (30.6%), including 2 aneurysm-related deaths (2.8%). CONCLUSIONS: Primary endovascular repair of IIAAs shows excellent results and should be considered as first-line therapy. Surgical backup should be available in emergency cases.


Asunto(s)
Aneurisma Roto/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/mortalidad , Aneurisma Roto/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Angiografía por Tomografía Computarizada , Conversión a Cirugía Abierta , Procedimientos Quirúrgicos Electivos , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Urgencias Médicas , Endofuga/mortalidad , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/mortalidad , Aneurisma Ilíaco/fisiopatología , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
Vasa ; 47(4): 311-317, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29583101

RESUMEN

BACKGROUND: The aim of this study was to evaluate the technical success of percutaneous ultrasound-guided access to the infraclavicular axillary artery with a suture-mediated closing device for patients requiring large-sized upper extremity access. PATIENTS AND METHODS: In 18 consecutive patients (17 male, one female, mean age 73.5 ± 9.6 years, range 52-88 years), artery accesses with the preclosing modification for chimney endografts was gained with 20 ultrasound-guided infraclavicular axillary. Retrospectively, the following endpoints were analysed: technical success of percutaneous ultrasound-guided puncture of the infraclavicular axillary artery as well as introduction and deployment, primary successful haemostasis by preclosing, bailout procedures, overall complication rate including local vascular, cerebrovascular, and peripheral neurological complications. RESULTS: Ultrasound-guided puncture and preclosing procedure was successful in all patients. Mean sheath size was 9.4 ± 1.6 French. Ultrasound-guided puncture as well as introduction and deployment were successful in all patients (100 %). Primary successful haemostasis by preclosing was 70 % (14/20). Postclosing with one or two devices enabled successful haemostasis in another 15 %. Bailout stent graft implantation was necessary in three accesses (15 %), either by transfemoral (n = 2) or transbrachial (n = 1) route. Overall complication rate was 16.5 %, all of them were minor haematomas. CONCLUSIONS: Percutaneous ultrasound-guided infraclavicular axillary artery access with preclosing modification seems feasible and safe. The access related complication rate is low and complications can potentially be managed by endovascular means.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Arteria Axilar , Pérdida de Sangre Quirúrgica/prevención & control , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares/instrumentación , Técnicas Hemostáticas/instrumentación , Hemorragia Posoperatoria/prevención & control , Técnicas de Sutura , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Arteria Axilar/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Hemorragia Posoperatoria/etiología , Diseño de Prótesis , Punciones , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Ultrasonografía Intervencional
18.
Eur Radiol ; 27(2): 454-463, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27221562

RESUMEN

OBJECTIVES: To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. METHODS: Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. RESULTS: Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. CONCLUSION: Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. KEY POINTS: • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.


Asunto(s)
Artrografía/instrumentación , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/normas
19.
Respiration ; 93(3): 207-211, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28110338

RESUMEN

We report a rare case of Takayasu's arteritis with isolated pulmonary artery stenosis in the presence of active hepatitis B and latent Mycobacterium tuberculosis infection in a middle-aged Asian woman who initially presented with severe dyspnea on exertion and recurrent syncope, occasional burning chest pains, and fatigue. Therapy of the active hepatitis B and latent M. tuberculosis infection together with a course of methotrexate led to a slight reversal of the symptoms, as angioplasty with or without stenting was not an option. The constellation described here hints at the possible link between hepatitis B and M. tuberculosis infection and the development of Takayasu's arteritis. The case also supports the little evidence available indicating that treatment of active hepatitis B infection could positively influence the course of Takayasu's arteritis.


Asunto(s)
Hepatitis B Crónica/complicaciones , Tuberculosis Latente/complicaciones , Arteria Pulmonar/diagnóstico por imagen , Estenosis de Arteria Pulmonar/diagnóstico por imagen , Arteritis de Takayasu/diagnóstico por imagen , Angiografía de Substracción Digital , Antituberculosos/uso terapéutico , Antivirales/uso terapéutico , Azatioprina/uso terapéutico , Femenino , Fluorodesoxiglucosa F18 , Glucocorticoides/uso terapéutico , Guanina/análogos & derivados , Guanina/uso terapéutico , Hepatitis B Crónica/tratamiento farmacológico , Humanos , Inmunosupresores/uso terapéutico , Isoniazida/uso terapéutico , Tuberculosis Latente/tratamiento farmacológico , Imagen por Resonancia Magnética , Metotrexato/uso terapéutico , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Arteria Pulmonar/patología , Radiofármacos , Recurrencia , Estenosis de Arteria Pulmonar/tratamiento farmacológico , Estenosis de Arteria Pulmonar/etiología , Estenosis de Arteria Pulmonar/patología , Arteritis de Takayasu/complicaciones , Arteritis de Takayasu/tratamiento farmacológico , Arteritis de Takayasu/patología
20.
Vascular ; 25(4): 396-401, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28068871

RESUMEN

Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin access (9/25; 36%) were managed through the percutaneous remote access. In all patients, a percutaneous transluminal angioplasty balloon was used to predilate the scar tissue and the femoral artery or the synthetic vascular graft after preclosing (ProGlide®; Abbott Vascular, Santa Clara, CA, USA). In 10 patients, requiring a 20 Fr sheath, a 6 mm percutaneous transluminal angioplasty balloon was used; and in the remaining 15, requiring a 24 Fr sheath, an 8 mm percutaneous transluminal angioplasty balloon. Preclosing was exclusively performed using ProGlide®. Mean follow-up was 15 months. Results In all cases, stent-graft deployment was successful. There was one surgical conversion (4%; 1/25) due to bleeding from a femoral anastomosis. Two cases required additional percutaneous maneuvers (postclosing with another system in one patient and endoluminal shielding with stent-graft in the other patient). No pseudoaneurysm or access complication occurred during the follow-up. Conclusions Percutaneous access in redo groins with scar tissue and/or synthetic vascular graft using ultrasound-guided punction, preclosing with ProGlide® system and predilation with percutaneous transluminal angioplasty balloon to introduce large size sheath as used for endovascular aortic repair showed to be feasible, safe and with few local complications.


Asunto(s)
Angioplastia de Balón/instrumentación , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Periférico/instrumentación , Cicatriz/etiología , Ingle/irrigación sanguínea , Dispositivos de Acceso Vascular , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Cicatriz/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Masculino , Resultado del Tratamiento , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA