Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Can J Anaesth ; 61(9): 794-800, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25141831

RESUMEN

PURPOSE: Many features can influence the choice of a supraglottic airway device (SAD), including ease of insertion, adequate ventilation pressures and lack of adverse effects. The goal of this randomized prospective trial was to compare the performance of the i-gel™ with that of the LMA-Supreme™. METHODS: One hundred adult patients (American Society of Anesthesiologists I-III) scheduled to undergo elective surgery under general anesthesia were randomized to either an i-gel (n = 50) or an LMA-Supreme (n = 50). The primary objective was to compare ventilation pressures. Secondary objectives included time and number of attempts needed to introduce the device, adverse effects, and repositioning. The endoscopic view of the glottic aperture and the position of the drain tubes in relation to the esophagus were also evaluated. RESULTS: The devices were inserted successfully in 46 (92%) patients in both groups. There was no significant difference in the [mean (SD)] leak pressure [i-gel: 23 (7) cm H2O vs LMA-Supreme: 21 (8) cm H2O; P = 0.14] or peak inspiratory pressure between both devices. Insertion time was shorter with the i-gel than with the LMA-Supreme [19 (7) sec vs 27 (17) sec, respectively; P = 0.003]. The vocal cords were completely visualized more often through the i-gel (70%) than through the LMA-Supreme (50%) (P = 0.007). Esophageal mucosa was easily visualized through the drain port in all but four patients, two patients in each group. There was no difference between groups regarding preoperative or postoperative complications. Postoperative patient discomfort was generally mild and comparable between both devices. CONCLUSION: Both the LMA-Supreme and the i-gel offer similar performance for positive pressure ventilation in paralyzed patients during general anesthesia. The i-gel was associated with a slightly faster insertion time and better fibrescopic visualization of the glottis. This trial was registered at Clinicaltrials.gov: NCT01001078.


Asunto(s)
Intubación Intratraqueal/instrumentación , Máscaras Laríngeas , Adulto , Anciano , Femenino , Humanos , Máscaras Laríngeas/efectos adversos , Masculino , Persona de Mediana Edad , Parálisis/fisiopatología , Respiración con Presión Positiva , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA