Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 85(2): 1081-9, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23214490

RESUMEN

Mass spectrometric imaging (MSI) is an analytical technique used to determine the distribution of individual analytes within a given sample. A wide array of analytes and samples can be investigated by MSI, including drug distribution in rats, lipid analysis from brain tissue, protein differentiation in tumors, and plant metabolite distributions. Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique capable of desorbing and ionizing a large range of compounds, and it is the most common ionization source used in MSI. MALDI mass spectrometry (MS) is generally considered to be a qualitative analytical technique because of significant ion-signal variability. Consequently, MSI is also thought to be a qualitative technique because of the quantitative limitations of MALDI coupled with the homogeneity of tissue sections inherent in an MSI experiment. Thus, conclusions based on MS images are often limited by the inability to correlate ion signal increases with actual concentration increases. Here, we report a quantitative MSI method for the analysis of cocaine (COC) from brain tissue using a deuterated internal standard (COC-d(3)) combined with wide-isolation MS/MS for analysis of the tissue extracts with scan-by-scan COC-to-COC-d(3) normalization. This resulted in significant improvements in signal reproducibility and calibration curve linearity. Quantitative results from the MSI experiments were compared with quantitative results from liquid chromatography (LC)-MS/MS results from brain tissue extracts. Two different quantitative MSI techniques (standard addition and external calibration) produced quantitative results comparable to LC-MS/MS data. Tissue extracts were also analyzed by MALDI wide-isolation MS/MS, and quantitative results were nearly identical to those from LC-MS/MS. These results clearly demonstrate the necessity for an internal standard for quantitative MSI experiments.


Asunto(s)
Encéfalo/citología , Cocaína/análisis , Núcleo Celular/química , Humanos , Estándares de Referencia , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/normas , Espectrometría de Masas en Tándem/normas
2.
J Am Soc Mass Spectrom ; 21(4): 564-71, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20097576

RESUMEN

Detection of drugs in tissue typically requires extensive sample preparation in which the tissue is first homogenized, followed by drug extraction, before the extracts are finally analyzed by LC/MS. Directly analyzing drugs in intact tissue would eliminate any complications introduced by sample pretreatment. A matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS(n)) method as been developed for the quantification of cocaine present in postmortem brain tissue of a chronic human cocaine user. It is shown that tandem mass spectrometry (MS(2) and MS(3) increase selectivity, which is critical for differentiating analyte ions from background ions such as matrix clusters and endogenous compounds found in brain tissue. It is also shown that the use of internal standards corrects for signal variability during quantitative MALDI, which can be caused by inhomogeneous crystal formation, inconsistent sample preparation, and laser shot-to-shot variability. The MALDI-MS(n) method developed allows for a single MS(3) experiment that uses a wide isolation window to isolate both analyte and internal standard target ions. This method is shown to provide improved precision [approximately 10-20 times reduction in percent relative standard deviation (%RSD)] for quantitative analysis compared to using two alternating MS(3) experiments that separately isolate the target analyte and internal standard ions.


Asunto(s)
Química Encefálica , Cocaína/análisis , Patologia Forense/normas , Espectrometría de Masa por Ionización de Electrospray/normas , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/normas , Detección de Abuso de Sustancias/normas , Patologia Forense/métodos , Guías como Asunto , Humanos , Internacionalidad , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Detección de Abuso de Sustancias/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA