Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Pulm Med ; 23(1): 411, 2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37898737

RESUMEN

OBJECTIVES: To examine the characteristics of blood lymphocyte subsets in dermatomyositis-interstitial lung disease (DM-ILD) inflicted patients with positive anti-melanoma differentiation-associated gene 5 (anti-MDA5), as well as its prognosis value in this set of patients. METHODS: Data were retrospectively collected from 253 DM-ILD patients from three hospitals in China between January 2016 to January 2021. Patients were grouped into anti-MDA5 antibody positive group (MDA5+ DM-ILD) and anti-MDA5 antibody negative group (MDA5- DM-ILD) based on myositis-specific autoantibody test results. Demographic characteristics, lymphocyte subsets patterns and other clinical features were compared between the two groups. The association of lymphocyte subsets with 180-day mortality was investigated using survival analysis in MDA5+ DM-ILD. RESULTS: Out of 253 eligible patients with DM-ILD, 59 patients were anti-MDA5+ and 194 were anti-MDA5-. Peripheral blood lymphocyte count, CD3+ count, percentage of CD3+, CD3+CD4+ count, and CD3+CD8+ count was lower in MDA5+ DM-ILD than in MDA5- DM-ILD- (all P < 0.001) as well as CD3-CD19+ count (P = 0.04). In MDA5+ DM-ILD, CD3+CD8+ count ≤ 49.22 cell/µL (HR = 3.81, 95%CI [1.20,12.14]) and CD3-CD19+ count ≤ 137.64 cell/µL (HR = 3.43, 95%CI [1.15,10.24]) were independent predictors of mortality. CD3+CD8+ count ≤ 31.38 cell/µL was associated with a higher mortality risk in all DM-ILD patients (HR = 8.6, 95%CI [2.12,31.44]) after adjusting for anti-MDA5 and other clinical characteristics. CONCLUSION: Significant lymphocytes decrease was observed in MDA5+ DM-ILD patients. CD3+CD8+ cell count was associated with worse prognosis in both MDA5+ DM-ILD and all DM-ILD patients.


Asunto(s)
Dermatomiositis , Enfermedades Pulmonares Intersticiales , Humanos , Pronóstico , Estudios Retrospectivos , Helicasa Inducida por Interferón IFIH1 , Enfermedades Pulmonares Intersticiales/complicaciones , Autoanticuerpos , Subgrupos Linfocitarios , Recuento de Linfocitos
2.
Front Med (Lausanne) ; 11: 1337669, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38651056

RESUMEN

The tracheal Y-shaped stent is mainly used for the treatment of critical patients with airway stenosis or esophagotracheal fistula near carina. A novel method for precise implantation of Y-shaped tracheal stents was developed using double-lumen endotracheal intubation and flexible bronchoscopy. This approach aims to address the limitations associated with X-ray or rigid bronchoscopy guidance, such as operational difficulties and the risk of inaccurate stent placement leading to implantation failure or suffocation. With this new technique, 13 tracheal Y-shaped stents were successfully implanted. This method shows promise in reducing the complexity of stent implantation and facilitating timely treatment for patients in need. Additionally, it has the potential to update current operating standards and guidelines for this procedure.

3.
Colloids Surf B Biointerfaces ; 84(2): 421-6, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21333504

RESUMEN

An electrochemical sensor based on the electrocatalytic activity of graphene (Gr) for sensitive detection of caffeine is presented. The electrochemical behaviors of caffeine on Nafion-Gr modified glassy carbon electrode (Nafion-Gr/GCE) were investigated by cyclic voltammetry and differential pulse voltammetry. The results showed that the Nafion-Gr/GCE exhibited excellent electrocatalytic activity to caffeine. Caffeine can be effectively accumulated at Nafion-Gr/GCE and produce a sensitive anodic peak. Such electrocatalytic behavior of Gr is attributed to its unique physical and chemical properties, e.g., subtle electronic characteristics and strong adsorptive capability. This electrochemical sensor shows an excellent performance for detecting caffeine with a detection limit of 1.2×10(-7) M (S/N=3), a reproducibility of 5.2% relative standard deviation, and a satisfied recovery from 98.6% to 102.0%. The sensor shows great promise for simple and sensitive determination of caffeine.


Asunto(s)
Cafeína/análisis , Grafito/química , Cafeína/química , Electroquímica/instrumentación , Electroquímica/métodos , Electrodos , Límite de Detección , Estructura Molecular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA