1.
Acta Anaesthesiol Scand ; 67(8): 994-1017, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37345870

RESUMEN

The set of guidelines for good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents was developed following an international consensus conference in Copenhagen in 1996 (Viby-Mogensen et al., Acta Anaesthesiol Scand 1996, 40, 59-74); the guidelines were later revised and updated following the second consensus conference in Stockholm in 2005 (Fuchs-Buder et al., Acta Anaesthesiol Scand 2007, 51, 789-808). In view of new devices and further development of monitoring technologies that emerged since then, (e.g., electromyography, three-dimensional acceleromyography, kinemyography) as well as novel compounds (e.g., sugammadex) a review and update of these recommendations became necessary. The intent of these revised guidelines is to continue to help clinical researchers to conduct high-quality work and advance the field by enhancing the standards, consistency, and comparability of clinical studies. There is growing awareness of the importance of consensus-based reporting standards in clinical trials and observational studies. Such global initiatives are necessary in order to minimize heterogeneous and inadequate data reporting and to improve clarity and comparability between different studies and study cohorts. Variations in definitions of endpoints or outcome variables can introduce confusion and difficulties in interpretation of data, but more importantly, it may preclude building of an adequate body of evidence to achieve reliable conclusions and recommendations. Clinical research in neuromuscular pharmacology and physiology is no exception.


Asunto(s)
Bloqueo Neuromuscular , Bloqueantes Neuromusculares , Humanos , Bloqueantes Neuromusculares/farmacología , Sugammadex , Bloqueo Neuromuscular/métodos
2.
South Med J ; 116(1): 33-37, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36578115

RESUMEN

OBJECTIVES: The majority of hip fracture patients in the United States are older adult patients with multiple comorbidities. Aortic stenosis (AS) in older adult patients with traumatic hip fracture is not uncommon. This study investigated the association between AS and postoperative mortality and serious complications. METHODS: In this retrospective cohort study, a chart review was performed of patients with AS who underwent hip fracture surgical repair between January 2011 and December 2019 within one health system. A control group of hip fracture patients without AS was identified and matched based on body mass index, age, sex, date of surgery and Charlson Comorbidity Index. The primary outcome of interest was 90-day mortality; secondary outcomes included 30-day postoperative complications, intensive care unit admission (ICU), and hospital length of stay. RESULTS: In total, 146 hip fracture patients with AS and 146 without AS were identified. In the AS group, there was an increased odds of 90-day mortality (odds ratio 2.64, 95% confidence interval 1.32-5.28, P = 0.005), and an increased odds of ICU admission (odds ratio 3.00, 95% confidence interval 1.36-6.68, P = 0.004). CONCLUSIONS: The presence of AS was independently associated with an increase in 90-day mortality and postoperative ICU stay in patients undergoing surgical repair of a hip fracture.


Asunto(s)
Fracturas de Cadera , Humanos , Estados Unidos/epidemiología , Anciano , Estudios Retrospectivos , Fracturas de Cadera/cirugía , Fracturas de Cadera/epidemiología , Hospitalización , Comorbilidad , Unidades de Cuidados Intensivos , Complicaciones Posoperatorias/epidemiología , Tiempo de Internación , Factores de Riesgo , Mortalidad Hospitalaria
3.
Anesth Analg ; 134(2): 269-275, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34403379

RESUMEN

BACKGROUND: The pattern of perioperative use of personal electronic devices (PEDs) among anesthesia providers in the United States is unknown. METHODS: We developed a 31-question anonymous survey of perioperative PED use that was sent to 813 anesthesiologists, anesthesiology residents, and certified registered nurse anesthetists at 3 sites within one health system. The electronic survey assessed patterns of PED use inside the operating room (OR), outside the OR, and observed in others. Questions were designed to explore the various purposes for PED use, the potential impact of specific hospital policies or awareness of medicolegal risk on PED use, and whether PED was a source of perioperative distraction. RESULTS: The overall survey response rate was 36.8% (n = 299). With regard to often/frequent PED activity inside the OR, 24% reported texting, 5% reported talking on the phone, and 11% reported browsing on the Internet. With regard to often/frequent PED activity outside the OR, 88% reported texting, 26% reported talking on the phone, and 63% reported browsing the Internet. With regard to often/frequent PED activity observed in others, 52% reported others texting, 14% reported others talking on the phone, and 34% reported others browsing the Internet. Two percent of respondents self-reported a distraction compared to 15% who had observed a distraction in others. Eighty percent of respondents recognized PED as a potential distraction for patient safety. CONCLUSIONS: Our data reinforce that PED use is prevalent among anesthesia providers.


Asunto(s)
Anestesia/tendencias , Anestesiólogos/tendencias , Enfermeras Anestesistas/tendencias , Teléfono Inteligente/tendencias , Encuestas y Cuestionarios/normas , Adulto , Anestesia/psicología , Anestesiólogos/psicología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermeras Anestesistas/psicología , Reproducibilidad de los Resultados
4.
Can J Anaesth ; 69(2): 196-204, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34796459

RESUMEN

PURPOSE: To evaluate whether echocardiographic assessment using the subcostal-only window (EASy) compared with focused transthoracic echocardiography (FTTE) using three windows (parasternal, apical, and subcostal) can provide critical information to serve as an entry-point technique for novice sonographers. METHODS: We conducted a retrospective study to compare diagnostic information acquired during EASy and FTTE examinations on qualitative left ventricular (LV) size, LV contractility, right ventricular (RV) size, RV contractility, interventricular septal position, and the presence of a significant pericardial effusion. Anesthesiology residents (novice users) performed FTTE for hemodynamic instability and/or respiratory distress or to define volume status in the perioperative setting, and later collected images were grouped into EASy and FTTE examinations. Both examinations were reviewed independently by a board-certified cardiologist and an anesthesiologist proficient in critical care echocardiography. FTTE and EASy findings were compared utilizing Gwet's AC1 coefficient to consider disagreement due to chance. RESULTS: We reviewed 102 patients who received FTTE over a period of 14 months. Of those, 82 had usable subcostal views and were included in the analysis. There was substantial agreement for qualitatively evaluating RV size (Gwet's AC1, 0.70; 95% confidence interval [CI], 0.54 to 0.85), LV size (Gwet's AC1, 0.73; 95% CI, 0.58 to 0.88), and LV contractility (Gwet's AC1, 0.73; 95% CI, 0.58 to 0.88) utilizing EASy and FTTE. Additionally, there was an almost perfect agreement when assessing the presence of pericardial effusion (Gwet's AC1, 0.98; 95% CI, 0.95 to 1.0) and RV contractility (Gwet's AC1, 0.84; 95% CI, 0.74 to 0.95) and evaluating the motion of the interventricular septum (Gwet's AC1, 0.92; 95% CI, 0.85 to 0.99). CONCLUSIONS: When images could be obtained from the subcostal window (the EASy examination), qualitative diagnostic information was sufficiently accurate compared with information obtained during FTTE examination. Our findings suggest that the EASy examination can serve as the entry point technique to FTTE for novice clinicians.


RéSUMé: OBJECTIF: Déterminer si l'évaluation échocardiographique se fondant sur la fenêtre unique sous-costale (EASy) par rapport à une échocardiographie transthoracique ciblée (ETTC) fondée sur trois fenêtres (parasternale, apicale et sous-costale) pouvait fournir des informations critiques et servir de technique de départ pour enseigner l'échographie aux novices. MéTHODE: Nous avons réalisé une étude rétrospective afin de comparer les informations diagnostiques acquises lors des examens échocardiographiques EASy et ETTC concernant la taille qualitative du ventricule gauche (VG), la contractilité du VG, la taille du ventricule droit (VD), la contractilité du VD, la position septale interventriculaire et la présence d'un épanchement péricardique significatif. Les résidents en anesthésiologie (utilisateurs novices) ont réalisé une ETTC pour détecter une instabilité hémodynamique et / ou une détresse respiratoire ou pour définir l'état volémique dans un contexte périopératoire; par la suite les images colligées ont été regroupées en examens EASy et ETTC. Les deux examens ont été indépendamment passés en revue par un cardiologue certifié et un anesthésiologiste formé en échocardiographie de soins intensifs. Les résultats des examens d'ETTC et d'EASy ont été comparés en utilisant le coefficient AC1 de Gwet pour tenir compte des désaccords dus au hasard. RéSULTATS: Nous avons passé en revue 102 patients ayant reçu une ETTC sur une période de 14 mois. De ce nombre, 82 ont présenté des vues sous-costales utilisables qui ont été incluses dans l'analyse. Il y avait une importante concordance entre les examens EASy et ETTC pour évaluer qualitativement la taille du VD (AC1 de Gwet, 0,70; intervalle de confiance [IC] à 95 %, 0,54 à 0,85), la taille du VG (AC1 de Gwet, 0,73; IC 95 %, 0,58 à 0,88) et la contractilité du VG (AC1 de Gwet, 0,73; IC 95 %, 0,58 à 0,88). De plus, il y avait une concordance quasi parfaite lors de l'évaluation de la présence d'épanchement péricardique (AC1 de Gwet, 0,98; IC 95 %, 0,95 à 1,0) et de la contractilité du VD (AC1 de Gwet, 0,84; IC 95 %, 0,74 à 0,95) et de l'évaluation du mouvement du septum interventriculaire (AC1 de Gwet, 0,92; IC 95 %, 0,85 à 0,99). CONCLUSION: Lorsque les images pouvaient être obtenues à partir de la fenêtre sous-costale (examen EASy), les informations diagnostiques qualitatives étaient suffisamment précises par rapport aux informations obtenues lors de l'examen d'ETTC. Nos résultats suggèrent que l'examen EASy peut servir de technique d'apprentissage précédant l'ETTC pour les cliniciens novices.


Asunto(s)
Ecocardiografía , Derrame Pericárdico , Ecocardiografía/métodos , Ventrículos Cardíacos , Humanos , Estudios Prospectivos , Estudios Retrospectivos
5.
South Med J ; 115(9): 681-686, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36055655

RESUMEN

OBJECTIVES: Blood transfusion represents an important and potentially modifiable risk in the daily practice of cardiac surgery. The risk profile and increasing cost of transfusion led us to study the effect of different maneuvers, interventions, or surgical techniques to minimize transfusion while maintaining patient safety. This study compares postoperative outcomes before and after incorporating a verbal hemoglobin (Hb) trigger during the surgical timeout in which the surgeon and anesthesiologist preemptively agree on a threshold for packed red blood cell (PRBC) administration in the perioperative period. METHODS: The authors performed a chart review of patients who underwent cardiac surgery from July 2013 through June 2014 at our institution. Patients who underwent surgery from July 2013 through December 2013 served as the pre-Hb trigger group, and patients who underwent surgery from January 2014 through June 2014 served as the post-Hb trigger group. Information collected included patient demographics, type of cardiac surgery, preoperative Hb, Hb trigger, and intraoperative and postoperative variables. The primary outcome was the incidence of PRBC transfusions. Secondary outcomes included the incidence of frozen plasma (FP) transfusion, mechanical ventilation beyond postoperative day 1, and 30-day mortality. RESULTS: The study included 191 patients, with 84 in the pre-Hb trigger group and 107 in the post-Hb trigger group. Intraoperative PRBC transfusions did not decrease in the posttrigger group compared with the pretrigger group (pretrigger 51.4% vs posttrigger 52.4%, P = 1.0); however, intraoperative FP administration was lower in the posttrigger group (65.4% vs 50.0%, P = 0.038). Postoperative mechanical ventilation beyond postoperative day 1 also was significantly lower in the posttrigger group compared with the pretrigger group (27.1% vs 14.3%, P = 0.035). CONCLUSIONS: Implementation of a verbal Hb trigger during the surgical timeout was associated with a reduction in FP administration and duration of mechanical ventilation, but not a decrease in PRBC transfusion and mortality.


Asunto(s)
Transfusión Sanguínea , Procedimientos Quirúrgicos Cardíacos , Comunicación , Transfusión de Eritrocitos , Hemoglobinas/metabolismo , Humanos
6.
Anesthesiology ; 135(4): 597-611, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34329371

RESUMEN

BACKGROUND: The paucity of easy-to-use, reliable objective neuromuscular monitors is an obstacle to universal adoption of routine neuromuscular monitoring. Electromyography (EMG) has been proposed as the optimal neuromuscular monitoring technology since it addresses several acceleromyography limitations. This clinical study compared simultaneous neuromuscular responses recorded from induction of neuromuscular block until recovery using the acceleromyography-based TOF-Watch SX and EMG-based TetraGraph. METHODS: Fifty consenting patients participated. The acceleromyography and EMG devices analyzed simultaneous contractions (acceleromyography) and muscle action potentials (EMG) from the adductor pollicis muscle by synchronization via fiber optic cable link. Bland-Altman analysis described the agreement between devices during distinct phases of neuromuscular block. The primary endpoint was agreement of acceleromyography- and EMG-derived normalized train-of-four ratios greater than or equal to 80%. Secondary endpoints were agreement in the recovery train-of-four ratio range less than 80% and agreement of baseline train-of-four ratios between the devices. RESULTS: Acceleromyography showed normalized train-of-four ratio greater than or equal to 80% earlier than EMG. When acceleromyography showed train-of-four ratio greater than or equal to 80% (n = 2,929), the bias was 1.3 toward acceleromyography (limits of agreement, -14.0 to 16.6). When EMG showed train-of-four ratio greater than or equal to 80% (n = 2,284), the bias was -0.5 toward EMG (-14.7 to 13.6). In the acceleromyography range train-of-four ratio less than 80% (n = 2,802), the bias was 2.1 (-16.1 to 20.2), and in the EMG range train-of-four ratio less than 80% (n = 3,447), it was 2.6 (-14.4 to 19.6). Baseline train-of-four ratios were higher and more variable with acceleromyography than with EMG. CONCLUSIONS: Bias was lower than in previous studies. Limits of agreement were wider than expected because acceleromyography readings varied more than EMG both at baseline and during recovery. The EMG-based monitor had higher precision and greater repeatability than acceleromyography. This difference between monitors was even greater when EMG data were compared to raw (nonnormalized) acceleromyography measurements. The EMG monitor is a better indicator of adequate recovery from neuromuscular block and readiness for safe tracheal extubation than the acceleromyography monitor.


Asunto(s)
Acelerometría/métodos , Electromiografía/métodos , Monitorización Neurofisiológica Intraoperatoria/métodos , Músculo Esquelético/fisiología , Bloqueo Neuromuscular/métodos , Acelerometría/normas , Adulto , Electromiografía/normas , Femenino , Humanos , Monitorización Neurofisiológica Intraoperatoria/normas , Masculino , Persona de Mediana Edad , Bloqueo Neuromuscular/efectos adversos , Bloqueo Neuromuscular/normas , Unión Neuromuscular/efectos de los fármacos , Unión Neuromuscular/fisiología , Fármacos Neuromusculares no Despolarizantes/administración & dosificación , Fármacos Neuromusculares no Despolarizantes/efectos adversos , Proyectos Piloto
7.
Ann Allergy Asthma Immunol ; 126(2): 180-186.e3, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33068738

RESUMEN

BACKGROUND: The estimated worldwide incidence of perioperative or periprocedural anaphylaxis (PA) is between 1 in 1250 and 1 in 20,000 procedures. OBJECTIVE: To evaluate the incidence of PA in the United States and compare patient characteristics and underlying risk factors using a large national database. METHODS: Using deidentified data from the nationwide inpatient sample from 2005 to 2014, we identified cases of PA through the International Classification of Diseases, Ninth Revision, Clinical Modification codes and conducted a retrospective analysis. RESULTS: Among 35,647,347 surgeries and procedures, there were 5458 (0.015%) PA cases identified. The incidence of PA was 15.3 cases per 100,000 procedures. When compared with controls, PA cases had an increased mortality (3.4% vs 1.4%; P < .001), median length of stay (5 vs 3 days; P < .001), and median hospital cost ($45,155 vs $24,734; P < .001). The age group between 18 and 34 years (odds ratio [OR], 1.34; 95% confidence interval [CI], 1.13-1.58; P < .001) and female sex (OR, 1.40; 95% CI, 1.31-1.49; P < .001) were associated with increased odds of PA. Transplant (OR, 3.35; 95% CI, 2.59-4.34; P < .001), hematologic (OR, 1.63; 95% CI, 1.30-2.05; P < .001), vascular (OR, 1.49; 95% CI, 1.30-1.67; P < .001), and cardiac (OR, 1.47; 95% CI, 1.30-1.67; P < .001) procedures were at increased risk for PA. Several comorbidities were associated with PA including chronic pulmonary disease (OR, 1.41; 95% CI, 1.31-1.51; P < .001). CONCLUSION: The incidence of PA is 1 in 6531 procedures, with a mortality of 1 in 191,652 procedures. PA has worsening outcomes compared with controls. The risk factors of PA include age, sex, procedure type, and comorbidities.


Asunto(s)
Anafilaxia/epidemiología , Periodo Perioperatorio , Procedimientos Quirúrgicos Operativos , Adolescente , Adulto , Anciano , Comorbilidad , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estados Unidos , Adulto Joven
8.
Br J Anaesth ; 127(6): 890-896, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34330411

RESUMEN

BACKGROUND: The incidence of fatal and near-fatal outcomes after perioperative anaphylaxis is unknown in the USA. Previously identified risk factors of neuromuscular-blocker-induced fatal perioperative anaphylaxis include male sex, obesity, and use of beta blockers. We examined the incidence of fatal and near-fatal outcomes after perioperative anaphylaxis in the USA and the underlying risk factors using a large national database. METHODS: Using the Nationwide Inpatient Sample from 2005 to 2014, we identified cases of fatal and near-fatal perioperative anaphylaxis, defined as perioperative anaphylaxis cases complicated by respiratory or cardiac arrest, using the International Classification of Diseases, Ninth Revision, Clinical Modification codes. RESULTS: Amongst 5223 perioperative anaphylaxis cases, the proportion of near-fatal or fatal cases attributable to perioperative anaphylaxis was 7.0% (95% confidence interval [CI]: 6.2-7.7), with near-fatal perioperative anaphylaxis cases accounting for 5.0% (95% CI: 4.4-5.6%) and fatal cases accounting for 2.0% (95% CI: 1.5-2.5%) of cases overall. Thus, the incidence of fatal or near-fatal perioperative anaphylaxis is 1.26 in 100 000 procedures. Risk factors for fatal or near-fatal perioperative anaphylaxis include age (≥65 yr); undergoing a cardiac procedure; and comorbid conditions of weight loss, non-metastatic solid tumours, metastatic cancer, paralysis, coagulopathy, renal failure, congestive heart failure, fluid and electrolyte disorder, and neurological disorders. Individuals with near-fatal or fatal perioperative anaphylaxis reactions had increased lengths of stay and hospital costs compared with controls. CONCLUSIONS: The incidence of fatal or near-fatal perioperative anaphylaxis in the USA was 1.26 in 100 000 procedures. Risk factors for fatal or near-fatal outcomes include older age, cardiac procedures, and specific comorbidities.


Asunto(s)
Anafilaxia/mortalidad , Complicaciones Intraoperatorias/mortalidad , Bloqueantes Neuromusculares/efectos adversos , Complicaciones Posoperatorias/mortalidad , Antagonistas Adrenérgicos beta/efectos adversos , Adulto , Anciano , Bases de Datos Factuales , Femenino , Humanos , Incidencia , Pacientes Internos/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Factores de Riesgo , Factores Sexuales , Estados Unidos
9.
Anesth Analg ; 132(5): 1421-1428, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33002932

RESUMEN

BACKGROUND: Subjective evaluations to confirm recovery from neuromuscular blockade with a peripheral nerve stimulator (PNS) is inadequate. Quantitative monitors are the only reliable method to confirm adequate recovery of neuromuscular function. Unfortunately, many clinicians are unfamiliar with such devices and there is concern that the introduction of objective monitoring would be exceedingly laborious and could cause workflow delays. This study investigates how long it takes experienced nurse anesthetists to apply various neuromuscular devices as well as their perception regarding the ease of application. METHODS: Twenty nurse anesthetists were consented and participated in an educational session that familiarized them with 3 devices: SunStim Plus PNS (SunMed, Grand Rapids, MI), the acceleromyography-based IntelliVue NMT device (Philips, Amsterdam, the Netherlands), and electromyography-based TetraGraph device (Senzime B.V., Uppsala, Sweden). Participants were timed while placing each monitor on patients in a real-world setting. For the quantitative devices (IntelliVue NMT and TetraGraph), participants were also timed when obtaining calibrated baseline train-of-four (TOF) ratios. Friedman test and pairwise Wilcoxon signed-rank tests were used to evaluate the difference in time to connect different devices. Participants were surveyed about how easy they found it to utilize these devices. RESULTS: After adjusting for multiple comparison, time to connect was significantly less for PNS (median, 29; range, 16-58 seconds) compared to either the TetraGraph device (median, 62.8; range, 32-101 seconds; P < .001) or the IntelliVue NMT device (median, 46; range: 28-90 seconds; P < .001). The difference in time to connect between the TetraGraph device and the IntelliVue NMT device was not statistically significant (P = .053), but it took significantly less time to calibrate the TetraGraph device than the IntelliVue NMT device (median difference, -16; range, -88 to 49 seconds; P = .002). The participants found applying either the IntelliVue NMT device (P = .042) or the TetraGraph device (P = .048) more difficult than applying a PNS while finding it easier to calibrate the TetraGraph device versus the IntelliVue NMT device (P < .001). CONCLUSIONS: It takes 19 seconds longer to apply a quantitative neuromuscular monitor (the IntelliVue NMT device) than a PNS. While this difference reached significance, this relatively minimal additional time represents an inappropriate barrier to the application of quantitative monitors. Regardless of which quantitative monitor was utilized, these nurse anesthetists found the application and utilization of such devices relatively straightforward.


Asunto(s)
Retraso en el Despertar Posanestésico/diagnóstico , Bloqueo Neuromuscular , Monitoreo Neuromuscular/instrumentación , Enfermeras Anestesistas , Adulto , Periodo de Recuperación de la Anestesia , Competencia Clínica , Retraso en el Despertar Posanestésico/etiología , Retraso en el Despertar Posanestésico/fisiopatología , Estimulación Eléctrica/instrumentación , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Masculino , Persona de Mediana Edad , Bloqueo Neuromuscular/efectos adversos , Monitoreo Neuromuscular/efectos adversos , Recuperación de la Función , Factores de Tiempo , Flujo de Trabajo
10.
Anesth Analg ; 130(4): 941-948, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31348055

RESUMEN

BACKGROUND: There is a need for easy to use, reliable neuromuscular monitors (NMMs). This multicenter, prospective, unblinded study compared the discomfort associated with neurostimulation in unmedicated healthy volunteers when using the new electromyography (EMG)-based TetraGraph and acceleromyography (AMG)-based TOF-Watch NMMs. The secondary aim was to compare the repeatability of the train-of-four (TOF) ratios (TOFRs) obtained with the 2 devices. METHODS: The TOF measurements of 135 volunteers from 3 university hospitals were analyzed (age: 38.3 ± 12 years [mean ± standard deviation [SD]]; male/female ratio = 63:72). The left or right ulnar nerve was stimulated at the wrist in TOF mode with 20, 30, 40, and 50 mA stimulating current intensities with both devices in random order. The TOF-Watch used standard electrocardiography (ECG) electrodes (Red Dot; 3M Health Care) for nerve stimulation. The stimulating surface area of 1 ECG electrode is 113 mm. The piezoelectric probe was attached to the thumb, and a hand adapter was used to ensure consistency of AMG measurements. The TetraGraph uses proprietary surface strip electrodes for nerve stimulation and muscle action potential recording, whose stimulating surface area is roughly twice as big as that of standard ECG electrodes (228.5 mm). The volunteers were asked to rate the discomfort associated with neurostimulation on a 0-10 verbal numerical rating scale (VNRS) score anchored with 0 (no pain) and 10 (worst pain ever experienced). A linear mixed-effects model was used to evaluate the difference in VNRS scores between devices. P <.05 was accepted as the level of significance. RESULTS: In the linear mixed-effects model, there were no differences in VNRS scores between devices at any of the stimulating current intensities, P = .38. The median (range) VNRS scores obtained with TOF-Watch and TetraGraph devices were 2 (0-7) vs 2 (0-8) at 20 mA, 3 (1-9) vs 3 (1-9) at 30 mA, 5 (1-10) vs 5 (1-10) at 40 mA, and 5 (1-10) vs 6 (1-10) at 50 mA stimulating current intensities. The mean of the 1469 TOFRs obtained with TetraGraph was 100.43% ± 7.74% (standard error = 0.2%). Due to technical difficulties, the repeatability of the TOFRs could not be determined. CONCLUSIONS: Despite the different size and design of the stimulating electrodes, the 2 NMMs caused the same level of discomfort in unmedicated healthy volunteers.


Asunto(s)
Monitoreo Neuromuscular/métodos , Dimensión del Dolor/métodos , Acelerometría , Potenciales de Acción , Adulto , Anciano , Estimulación Eléctrica , Electrocardiografía , Electromiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Estudios Prospectivos , Nervio Cubital , Vigilia
11.
Can J Anaesth ; 67(12): 1789-1797, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32949009

RESUMEN

PURPOSE: While sugammadex (SGX) is not approved for use in patients with end-stage renal disease (ESRD), its administration in this patient population has been reported. We designed the current study to review all instances of patients with ESRD receiving SGX and to describe their clinical outcomes. METHODS: This is a historical cohort study of 219 patients with chronic kidney disease stage 5 who received SGX in one of three hospital locations within the same academic health system. Data were collected between 7 March 2016 and 1 August 2019 and included demographics, notable events from the anesthesia records, and postoperative complications. The primary outcome included any complication possibly related to SGX such as hypersensitivity reactions, need for reintubation, hypoxemia, pneumonia, and residual neuromuscular blockade. Secondary outcomes included any other complication not included in the primary outcome and/or patient mortality within 30 days after the procedure. RESULTS: No patient experienced a hypersensitivity reaction. Three patients required reintubation while two patients developed hypoxemia that did not require reintubation. One patient developed hospital-acquired pneumonia. Fifty (23%) patients developed other postoperative complications (different from our primary outcome) and nine patients (4%) died during the subsequent 30 postoperative days. None of the primary or secondary outcomes appeared to be related to SGX use. CONCLUSIONS: We provide incremental evidence that SGX could be considered as an alternative neuromuscular blockade reversal agent in patients with ESRD.


RéSUMé: OBJECTIF : Bien que le sugammadex (SGX) ne compte pas parmi ses indications une utilisation chez les patients atteints d'insuffisance rénale terminale (IRT), son administration à cette population de patients est rapportée. Nous avons conçu cette étude afin de passer en revue tous les cas de patients atteints d'IRT ayant reçu du SGX et décrire leurs devenirs cliniques. MéTHODE : Il s'agit d'une étude de cohorte historique portant sur 219 patients atteints d'insuffisance rénale chronique de stade 5 ayant reçu du SGX dans l'un de trois hôpitaux appartenant au même réseau de santé universitaire. Les données démographiques, les événements significatifs notés dans les dossiers anesthésiques et les complications postopératoires ont été colligés entre le 7 mars 2016 et le 1er août 2019. Le critère d'évaluation principal incluait toute complication possiblement liée à l'utilisation de SGX telle qu'une réaction d'hypersensibilité, une réintubation, une hypoxémie, une pneumonie, et un bloc neuromusculaire résiduel. Les critères d'évaluation secondaires comprenaient toute autre complication non incluse dans notre critère d'évaluation principal et/ou la mortalité des patients dans les 30 jours suivant l'intervention. RéSULTATS : Aucun patient n'a eu de réaction d'hypersensibilité. Trois patients ont dû être réintubés, et deux patients ont développé une hypoxémie qui n'a pas nécessité de réintubation. Un patient a contracté une pneumonie nosocomiale. Cinquante (23 %) patients ont souffert d'autres complications postopératoires (différentes de notre critère d'évaluation principal) et neuf patients (4 %) sont décédés au cours des 30 jours postopératoires subséquents. Aucun de nos critères d'évaluation primaire ou secondaires ne semblaient liés à l'utilisation de SGX. CONCLUSION : Nous proposons des données probantes supplémentaires selon lesquelles le SGX pourrait être envisagé comme agent décurarisant alternatif chez les patients atteints d'IRT.


Asunto(s)
Fallo Renal Crónico , Bloqueo Neuromuscular , Estudios de Cohortes , Humanos , Fallo Renal Crónico/complicaciones , Neostigmina , Sugammadex
12.
BMC Anesthesiol ; 20(1): 46, 2020 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-32093637

RESUMEN

BACKGROUND: This quality improvement (QI) project was performed at a single center to determine the incidence of postoperative complications associated with use of cuffed airway devices. An educational program was then completed that involved training our anesthesia providers about complications related to excessive cuff pressure and how to utilize a quantitative cuff pressure measurement device (manometer). The impact of this educational initiative was assessed by comparing the incidence of postoperative complications associated with the use of airway devices before and after the training period. METHODS: After approval by our institution's Institutional Review Board, a pre-intervention (baseline) survey was obtained from 259 adult patients after having undergone surgery with general anesthesia with the use of an endotracheal tube (ETT) or laryngeal mask airway (LMA). Survey responses were used to determine the baseline incidence of sore throat, hoarseness, and dysphagia. Once these results were obtained, education was provided to the anesthesia department members addressing the complications associated with excessive cuff pressures, appropriate cuff pressures based on manufacturer recommendations, and instructions on the use of a quantitative monitor to determine cuff pressure (manometry). Clinical care was then changed by requiring intraoperative cuff pressure monitoring throughout our institution for all surgical patients. After this educational period, 299 patients completed the same survey describing postoperative airway complications. RESULTS: The use of manometry reduced the incidence of moderate-to-severe postoperative sore throat in the pre- vs. post-intervention groups (35 patients vs 31 patients, p = 0.045), moderate to severe hoarseness (30 patients vs 13, patients p = 0.0001), and moderate-to-severe dysphagia (13 patients vs 5 patients, p = 0.03). CONCLUSION: Caring for patients in the perioperative setting frequently entails placement of an airway device. This procedure is associated with several potential complications, including sore throat, coughing, and vocal cord damage. Our quality improvement initiative has shown that intraoperative management of intra-cuff pressure based on manometry is feasible to implement in clinical practice and can reduce postoperative airway complications.


Asunto(s)
Cuidados Intraoperatorios/métodos , Intubación Intratraqueal/efectos adversos , Máscaras Laríngeas/efectos adversos , Manometría/métodos , Complicaciones Posoperatorias/prevención & control , Mejoramiento de la Calidad , Competencia Clínica , Trastornos de Deglución/prevención & control , Diseño de Equipo , Ronquera/prevención & control , Humanos , Incidencia , Cuidados Intraoperatorios/educación , Faringitis/prevención & control , Presión
13.
J Cardiothorac Vasc Anesth ; 34(7): 1846-1852, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31928843

RESUMEN

OBJECTIVES: Expert guidelines consistently list esophageal stricture (ES) as a contraindication to the performance of transesophageal echocardiography (TEE), although anecdotally the authors are aware of patients with ES undergoing TEE without apparent complication. Therefore the authors sought to determine the outcomes of patients with ES who had undergone TEE at their institution. DESIGN: Single-center, retrospective review. SETTING: Academic medical center (clinic and affiliated hospital). PARTICIPANTS: Patients with documented ES who also underwent TEE. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: In a 10-year period, 1,083 TEE reports were generated for 823 patients who had a diagnosis of ES. One case of esophageal perforation occurred (1/1,083 examination reports [0.09%]) in an 85-year-old male with gastroesophageal reflux disease-related ES who had undergone esophageal dilation the same day as the TEE. In 17.2% of the TEE reports reviewed, changes to the conduct of the examination occurred, such as use of a pediatric probe or avoidance of transgastric imaging. In 8% of reviewed examinations, procedural difficulty was recorded. CONCLUSIONS: Patients with nonmalignant ES commonly present for TEE (>100 per year, on average, at the authors' institution). Severe TEE-related esophageal injury rarely occurred in patients with ES. However, changes to the conduct of the TEE examination and procedural difficulty were not infrequent in this group. Clinicians contemplating TEE in patients with ES should prepare for the possibility of altered examination conduct and possible procedural difficulty.


Asunto(s)
Perforación del Esófago , Estenosis Esofágica , Anciano de 80 o más Años , Niño , Ecocardiografía Transesofágica/efectos adversos , Estenosis Esofágica/diagnóstico por imagen , Estenosis Esofágica/etiología , Estudios de Factibilidad , Humanos , Masculino , Estudios Retrospectivos
14.
J Cardiothorac Vasc Anesth ; 34(1): 1-11, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31759862

RESUMEN

This highlights in our specialty for 2019 begin with the ongoing major developments in transcatheter valve interventions. Thereafter, the advances in left ventricular assist devices are reviewed. The recent focus on conduit selection and robotic options in coronary artery bypass surgery are then explored. Finally, this special articles closes with a discussion of pulmonary hypertension in noncardiac surgery, anesthetic technique in cardiac surgery, as well as postoperative pneumonia and its outcome consequences.


Asunto(s)
Anestesia , Anestesiología , Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente de Arteria Coronaria , Humanos , Resultado del Tratamiento
15.
Can J Anaesth ; 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609683
16.
J Cardiothorac Vasc Anesth ; 33(5): 1393-1406, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30201404

RESUMEN

Disorders affecting red blood cells (RBCs) are uncommon yet have many important physiologic considerations for patients undergoing cardiac surgery. RBC disorders can be categorized by those that are congenital or acquired, and further by disorders affecting the RBC membrane, hemoglobin, intracellular enzymes, or excessive RBC production. A foundational understanding of the physiologic derangement for these disorders is critical when considering perioperative implications and optimization, strategies for cardiopulmonary bypass, and the rapid recognition and treatment if complications occur. This review systematically outlines the RBC disorders of frequency and relevance with an emphasis on how the disorder affects normal physiologic processes, a review of the literature related to the disorder, and the implications and recommendations for patients undergoing cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Eritrocitos/fisiología , Enfermedades Hematológicas/sangre , Enfermedades Hematológicas/diagnóstico , Atención Perioperativa/métodos , Transfusión de Sangre Autóloga/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Eritrocitos Anormales/fisiología , Enfermedades Hematológicas/cirugía , Humanos
18.
BMC Anesthesiol ; 17(1): 140, 2017 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-29041919

RESUMEN

Sugammadex, a modified gamma-cyclodextrin, has changed clinical practice of neuromuscular reversal dramatically. With the introduction of this selective relaxant binding agent, rapid and reliable neuromuscular reversal from any depth of block became possible. Sugammadex can reverse neuromuscular blockade without the muscarinic side effects typically associated with the administration of acetylcholinesterase inhibitors. However, what remained unchanged is the incidence of residual neuromuscular blockade. It is known that sugammadex cannot always prevent its occurrence, if appropriate dosing is not chosen based on the level of neuromuscular paralysis prior to administration determined by objective neuromuscular monitoring. Alternatively, excessive doses of sugammadex administered in an attempt to ensure full and sustained reversal may affect the effectiveness of rocuronium in case of immediate reoperation or reintubation. In such emergent scenarios that require onset of rapid and reliable neuromuscular blockade, the summary of product characteristics (package insert) recommends using benzylisoquinolinium neuromuscular blocking agents or a depolarizing agent. However, if rapid intubation is required, succinylcholine has a significant number of side effects, and benzylisoquinolinium agents may not have the rapid onset required. Therefore, prior administration of sugammadex introduces a new set of potential problems that require new solutions. This novel reversal agent thus presents new challenges and anesthesiologists must familiarize themselves with specific issues with its use (e.g., bleeding risk, hypermagnesemia, hypothermia). This review will address sugammadex administration in such special clinical situations.


Asunto(s)
Retraso en el Despertar Posanestésico/inducido químicamente , Retraso en el Despertar Posanestésico/tratamiento farmacológico , Bloqueo Neuromuscular/métodos , Fármacos Neuromusculares no Despolarizantes/administración & dosificación , gamma-Ciclodextrinas/administración & dosificación , Animales , Retraso en el Despertar Posanestésico/diagnóstico , Relación Dosis-Respuesta a Droga , Humanos , Bloqueo Neuromuscular/efectos adversos , Fármacos Neuromusculares no Despolarizantes/efectos adversos , Sugammadex , gamma-Ciclodextrinas/efectos adversos
SELECCIÓN DE REFERENCIAS