Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Ugeskr Laeger ; 164(32): 3759-63, 2002 Aug 05.
Artículo en Danés | MEDLINE | ID: mdl-12362608

RESUMEN

Infections caused by Staphylococcus aureus comprise relatively benign local skin infections, as well as serious generalised conditions. In Denmark, more than 85% of all S. aureus isolates are found resistant to penicillin, whereas resistance to methicillin is rare (< 1%) and therefore one of the penicillinase-stable penicillins is still the drug of choice. Dicloxacillin is usually chosen, because of its superior penicillinase stability. Infections caused by methicillin resistant strains may be treated with different combinations of macrolides, fusidic acid, aminoglycosides, fluoroquinolones, and rifampicin, but vancomycin is generally used. Newer drugs like the oxazolidinones and streptogramins are effective against methicillin-resistant strains and will be available in Denmark within a short time. Antibiotic treatment, however, is most often only a supplement to surgical intervention. This paper deals with the clinical picture and treatment of some common S. aureus infections.


Asunto(s)
Antibacterianos/administración & dosificación , Infecciones Estafilocócicas , Staphylococcus aureus , Antibacterianos/efectos adversos , Artritis Infecciosa/tratamiento farmacológico , Artritis Infecciosa/microbiología , Artritis Infecciosa/cirugía , Farmacorresistencia Bacteriana Múltiple , Contaminación de Equipos , Reacción a Cuerpo Extraño/tratamiento farmacológico , Reacción a Cuerpo Extraño/microbiología , Reacción a Cuerpo Extraño/cirugía , Humanos , Resistencia a la Meticilina , Osteomielitis/tratamiento farmacológico , Osteomielitis/microbiología , Osteomielitis/cirugía , Resistencia a las Penicilinas , Penicilinas/administración & dosificación , Penicilinas/efectos adversos , Enfermedades Cutáneas Bacterianas/tratamiento farmacológico , Enfermedades Cutáneas Bacterianas/microbiología , Enfermedades Cutáneas Bacterianas/cirugía , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/cirugía , Staphylococcus aureus/inmunología , Staphylococcus aureus/aislamiento & purificación , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/microbiología , Infección de la Herida Quirúrgica/cirugía
2.
Scand J Infect Dis ; 40(1): 24-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18097982

RESUMEN

Pharmacokinetics of unbound anti-infectives in bone is difficult to characterize. The aim of this study was to assess the feasibility of the microdialysis technique to cancellous bone for single dose pharmacokinetic investigations of the anti-infective linezolid. Serial bone biopsies (left tibia) and microdialysate samples (right tibia: 2 catheters) as well as plasma and bone marrow samples were obtained from 10 pigs. The concentrations of linezolid reached bacteriostatic levels in plasma, bone marrow, bone biopsies and microdialysates. With the use of microdialysis we here present the first results for unbound linezolid bone penetration. Unbound linezolid concentrations in bone obtained by microdialysis were lower than might have been expected from previous bone biopsy studies. To achieve effective concentrations (24 h) for susceptible organisms the chosen dose of linezolid might not be sufficient.


Asunto(s)
Acetamidas/farmacocinética , Antiinfecciosos/farmacocinética , Oxazolidinonas/farmacocinética , Acetamidas/administración & dosificación , Animales , Antiinfecciosos/administración & dosificación , Huesos/química , Estudios de Factibilidad , Femenino , Infusiones Intravenosas , Linezolid , Microdiálisis/métodos , Oxazolidinonas/administración & dosificación , Sus scrofa , Distribución Tisular
3.
Scand J Infect Dis ; 37(4): 284-7, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15804664

RESUMEN

Microdialysis has produced valuable information concerning the distribution of antibiotics in peripheral tissue. The aim of this study was to measure the local distribution of gentamicin in cancellous bone tissue after the application of a Gentacoll sponge. Two microdialysis catheters were inserted into the cancellous bone of 9 pigs. After calibration of the microdialysis, a Gentacoll sponge was implanted, either dry or wet, into the bone marrow of the tibia. Serum and microdialysates were obtained over a period of 6 h. Data presented are median (range). A rank sum test was performed for statistical analysis. The peak concentration was 120 mg/l (33-585) (wet group) and 178 mg/l (60-1294) (dry group) (p=0.31). The AUC6 of the catheters placed 1 cm away from the implant was 24,431 mg*min/l (5155-152,855) and the AUC6 of the catheter placed 2 cm away from the implant was 13,759 mg*min/l (6351-74,573) (p=0.25). The study showed that peak concentrations and AUC6 did not differ between the wet- and dry-application group; neither did the distance from the sponge to the catheter have a significant impact on the distribution of gentamicin. It seems that microdialysis is capable to measure concentrations of locally applied antibiotics.


Asunto(s)
Gentamicinas/administración & dosificación , Gentamicinas/farmacocinética , Microdiálisis/métodos , Animales , Área Bajo la Curva , Huesos , Colágeno , Implantes de Medicamentos , Femenino , Porcinos
4.
Acta Orthop Scand ; 75(1): 106-8, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15022818

RESUMEN

BACKGROUND: Many amputations might be delayed or prevented by more effective clinical supervision of the diabetic foot ulcer. The aim of this study was to measure the local metabolism on the edge of a diabetic ulcer and compare it to healthy subcutaneous tissue. PATIENTS AND METHODS: In 5 non-fasting diabetic patients, we inserted a microdialysis catheter into the edge of a diabetic ulcer and a reference catheter into healthy abdominal subcutaneous tissue, and recorded the local concentrations of glucose, lactate and glycerol during rest. RESULTS: The concentrations of glucose in the ulcers were 7.8 mM (SEM 1.9) and in the reference tissue 10.6 mM (SEM 1.8) (p = 0.4). The concentrations of lactate were 2.9 mM (SEM 0.7) and 2.1 mM (SEM 0.7) (p = 0.2), while those of glycerol were 290 microM (SEM 84) vs 98 microM (SEM 7.2) (p = 0.002). INTERPRETATION: This study shows that microdialysis can detect differences in dialysate concentrations of metabolites in diabetic ulcers and a reference tissue, providing valuable information concerning metabolites in the diabetic foot ulcer. Future studies should combine the technique with measurements of local blood flow.


Asunto(s)
Pie Diabético/metabolismo , Líquido Extracelular/metabolismo , Glucosa/metabolismo , Glicerol/metabolismo , Ácido Láctico/metabolismo , Microdiálisis , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tejido Subcutáneo/metabolismo
5.
Acta Orthop Scand ; 74(1): 37-41, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12635790

RESUMEN

In a randomized prospective study we compared 2 femoral plugs as regards probable migration of the restrictor, cement leakage and possible early aseptic loosening. In group I, the femoral canal was plugged with a resorbable Shuttle Stop (HC Implants, BV. Leiden, The Netherlands). In group II, a nonresorbable restrictor of polyethylene was used (De Puy, UK). Both groups were identical as regards age, gender and primary disease. All patients were followed for at least 2 years after surgery. Postoperatively, we found more failures with displacement of the femoral plug and cement leakage in group I than in group II. At the 2-year follow-up, we found no differences in stem loosening or grade of radiolucent lines in the cement-bone interface. We can not recommend the Shuttle Stop for femoral canal sealing in total hip replacememt.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementación , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Biodegradación Ambiental , Femenino , Migración de Cuerpo Extraño , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Poliésteres/uso terapéutico , Polietilenglicoles/uso terapéutico , Estudios Prospectivos , Falla de Prótesis
6.
J Antimicrob Chemother ; 54(1): 263-5, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15190036

RESUMEN

OBJECTIVES: Knowledge concerning the distribution of antibiotics in bone tissue is valuable for pharmacokinetic and clinical use. Unfortunately, appropriate techniques are difficult to apply. We introduced microdialysis catheters to cancellous bone tissue for the investigation of gentamicin levels and compared the pharmacokinetics measured with values obtained from bone samples. METHODS: After two microdialysis catheters had been inserted into cancellous bone, eight pigs received an intravenous bolus of 240 mg of gentamicin. Microdialysates and bone samples were obtained over a period of 6 h and drug concentrations were measured. RESULTS: The area under the curves of the two microdialysates and bone samples were 1569, 1721 and 1533 mg.min/L (ANOVA, P=0.81). Reproducibility of the measurements from the microdialysates was defined as the mean ratio of AUC6/catheter no. 1/AUC6/catheter no. 2. This ratio was 1.02. CONCLUSIONS: Microdialysis is a suitable, relatively non-invasive and reproducible technique for dynamic and quantitative measurement of gentamicin levels in experimental research.


Asunto(s)
Antibacterianos/análisis , Antibacterianos/farmacocinética , Huesos/química , Gentamicinas/análisis , Gentamicinas/farmacocinética , Microdiálisis/métodos , Animales , Antibacterianos/sangre , Área Bajo la Curva , Calibración , Femenino , Gentamicinas/sangre , Reproducibilidad de los Resultados , Porcinos
7.
Acta Orthop Scand ; 74(5): 611-6, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14620985

RESUMEN

We used microdialysis to study gentamicin in cortical bone and compared these results to values obtained in bone specimens. 10 healthy pigs were given an intravenous bolus of 160 mg of gentamicin. We measured reproducibility by inserting two microdialysis catheters into the cortex of tibial diaphyses and by taking samples of serum, dialysates and bone specimens during 6 hours and measuring the concentrations of this antibiotic. The peak concentrations in the two microdialysis probes and bone specimens were 3 mg/L, 2.9 mg/L and 2.6 mg/L (Anova, p = 0.3). Similarly, the areas under the curve from 0 to 6 hours (AUC6h) were 704 mg/min/L, 661 mg/min/L and 569 mg/min/L (Anova, p = 0.07). The reproducibility of the measurements of the microdialysates was evaluated with the mean AUC(6h/catheter no.1)/AUC(6h/catheter no. 2) ratio, which was 1.12. It seems that microdialysis is a suitable method for making dynamic and quantitative measurements of gentamicin in bone.


Asunto(s)
Antibacterianos/farmacocinética , Huesos/metabolismo , Gentamicinas/farmacocinética , Microdiálisis , Animales , Antibacterianos/sangre , Área Bajo la Curva , Femenino , Gentamicinas/sangre , Microdiálisis/métodos , Porcinos
8.
J Arthroplasty ; 18(6): 735-40, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-14513446

RESUMEN

A prospective analysis of plain serial radigraphs (PSR), digital subtraction arthrography (DSA), and radionuclide bone scans (RBS) was performed in 56 cemented total hip arthroplasties to evaluate the efficacy and usefulness of each study in the diagnosis of loosening. To avoid selection bias in the evaluation of DSA and RBS, the decision to perform repeat surgery was based exclusively on the clinical history and PSR. Results of each study were compared with intraoperative assessment of the status of components and expressed in terms of sensitivity, specificity, and accuracy. Overall accuracy for the acetabular component by PSR was 66%; by DSA, 93%; by RBS, 46%. Overall accuracy for the femoral component by PSR was 79%; by DSA, 93%; RBS, 50%. Our results indicate that DSA can be recommended as a further analysis in cases with a painful hip prosthesis and no or inconclusive findings on PSR. RBS did not give any useful information and cannot be recommended routinely.


Asunto(s)
Artrografía/métodos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Técnica de Sustracción , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Falla de Prótesis , Radiografía Intervencional , Cintigrafía , Reoperación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA