1.
Health Phys ; 112(4): 357-363, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28234695

RESUMEN

Many dosimeter and instrument calibration sources, especially Cs irradiators permanently installed in facilities, are infrequently calibrated since their geometry is not subject to large variation, their mechanisms are simple, and their operation can be visibly error-free for decades. Only decay corrections are needed to know delivered doses at fixed locations once a thorough characterization of such facilities is completed. For one such Cs source, however, collected current values in a span of a few days were found to drop significantly. Malfunction of the internal positioning mechanisms through wear were found to be the cause. This paper suggests periodic source calibrations for the timely identification of source failures that could cause gross errors in dose delivery. In addition, a rigorous analysis of the magnitude of uncertainties and errors in dose delivery using a calibration source is included, which is based upon newly collected experimental data. This provides a technical basis for calibration procedures to ensure a given accuracy and precision of dose delivery.


Asunto(s)
Calibración/normas , Radioisótopos de Cesio/análisis , Radioisótopos de Cesio/normas , Arquitectura y Construcción de Instituciones de Salud/normas , Radiometría/instrumentación , Radiometría/normas , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/normas , Michigan , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Health Phys ; 112(3): 237-245, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28121723

RESUMEN

Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired statistical confidence. This paper establishes a technical basis for determining the required number of readings for a particular application of these dosimeters when using certain OSL dosimetry systems.


Asunto(s)
Artefactos , Guías como Asunto , Iluminación/normas , Dispositivos Ópticos/normas , Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente/normas , Calibración/normas , Diseño de Equipo , Análisis de Falla de Equipo , Iluminación/instrumentación , Dosis de Radiación , Reproducibilidad de los Resultados , Semiconductores , Sensibilidad y Especificidad