Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Evid Based Dent Pract ; 23(1S): 101794, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36707170

RESUMEN

BACKGROUND: When dental patients seek care, treatments are not always successful,that is patients' oral health problems are not always eliminated or substantially reduced. Identifying these patients (treatment non-responders) is essential for clinical decision-making. Group-based trajectory modeling (GBTM) is rarely used in dentistry, but a promising statistical technique to identify non-responders in particular and clinical distinct patient groups in general in longitudinal data sets. AIM: Using group-based trajectory modeling, this study aimed to demonstrate how to identify oral health-related quality of life (OHRQoL) treatment response patterns by the example of patients with a shortened dental arch (SDA). METHODS: This paper is a secondary data analysis of a randomized controlled clinical trial. In this trial SDA patients received partial removable dental prostheses replacing missing teeth up to the first molars (N = 79) either or the dental arch ended with the second premolar that was present or replaced by a cantilever fixed dental prosthesis (N = 71). Up to ten follow-up examinations (1-2, 6, 12, 24, 36, 48, 60, 96, 120, and 180 months post-treatment) continued for 15 years. The outcome OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). Exploratory GBTM was performed to identify treatment response patterns. RESULTS: Two response patterns could be identified - "responders" and "non-responders." Responders' OHRQoL improved substantially and stayed primarily stable over the 15 years. Non-responders' OHRQoL did not improve considerably over time or worsened. While the SDA treatments were not related to the 2 response patterns, higher levels of functional, pain-related, psychological impairment in particular, and severely impaired OHRQoL in general predicted a non-responding OHRQoL pattern after treatment. Supplementary, a 3 pattern approach has been evaluated. CONCLUSIONS: Clustering patients according to certain longitudinal characteristics after treatment is generally important, but specifically identifying treatment in non-responders is central. With the increasing availability of OHRQoL data in clinical research and regular patient care, GBTM has become a powerful tool to investigate which dental treatment works for which patients.


Asunto(s)
Dentadura Parcial Removible , Calidad de Vida , Humanos , Dentadura Parcial Removible/psicología , Arco Dental , Salud Bucal , Diente Molar
2.
Lasers Med Sci ; 37(2): 1017-1030, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34247315

RESUMEN

Inadvertent Er:YAG laser irradiation occurs in dentistry and may harm restorative materials in teeth. The aim of this in vitro study was to quantify Er:YAG laser-induced damage to a nanohybrid composite in simulated clinical scenarios for inadvertent direct and indirect (reflection) laser irradiation. The simulation was performed by varying the output energy (OE;direct˃indirect) reaching the specimen and the operating distance (OD;direct˂indirect). Composite specimens were irradiated by an Er:YAG laser. The ablation threshold was determined and clinically relevant parameters were applied (n = 6 for each OE/OD combination) for direct (OE: 570 mJ/OD: 10 mm, OE: 190 mJ/OD: 10 mm) and indirect irradiation (OE: 466 mJ/OD: 15 mm, OE: 57 mJ/OD: 15 mm, OE: 155 mJ/OD: 15 mm, OE: 19 mJ/OD: 15 mm). The extent of damage in the form of craters was evaluated using a laser scanning microscope (LSM) and a conventional light microscope (LM). The ablation threshold was determined to be 2.6 J/cm2. The crater diameter showed the highest value (LM: 1075 ± 18 µm/LSM: 1082 ± 17 µm) for indirect irradiation (reflectant:dental mirror) (OE: 466 mJ/OD: 15 mm). The crater depth showed the highest and comparable value for direct (OE: 570 mJ/OD: 10 mm; LSM: 89 ± 2 µm) and indirect irradiation (OE: 466 mJ/OD: 15 mm; LSM: 90 ± 4 µm). For each OD, the crater diameter, depth, and volume increased with higher laser fluence. However, the OD-and thus the laser spot diameter-also had an enlarging effect. Thus, indirect irradiation (reflectant:dental mirror) with only 47% of the laser fluence of direct irradiation led to a larger diameter and a comparable depth. The three-dimensional extent of the crater was large enough to cause roughening, which may lead to plaque accumulation and encourage caries, gingivitis, and periodontitis under clinical conditions. Clinicians should be aware that reflected irradiation can still create such craters.


Asunto(s)
Láseres de Estado Sólido , Diente , Láseres de Estado Sólido/efectos adversos , Microscopía Electrónica de Rastreo , Diente/cirugía
3.
BMC Oral Health ; 20(1): 178, 2020 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-32600405

RESUMEN

BACKGROUND: The aim of this prospective clinical study was to investigate differences between virtually planned and clinically achieved implant positions in completely template-guided implant placements as a function of the tooth area, the use of alveolar ridge preservation, the implant length and diameter, and the primary implant stability. METHODS: The accuracy of 48 implants was analyzed. The implants were placed in a completely template-guided manner. The data of the planned implant positions were superimposed on the actual clinical implant positions, followed by measurements of the 3D deviations in terms of the coronal (dc) and apical distance (da), height (h), angulation (ang), and statistical analysis. RESULTS: The mean dc was 0.7 mm (SD: 0.3), the mean da was 1.4 mm (SD: 0.6), the mean h was 0.3 mm (SD: 0.3), and the mean ang was 4.1° (SD: 2.1). The tooth area and the use of alveolar ridge preservation had no significant effect on the results in terms of the implant positions. The implant length had a significant influence on da (p = 0.02). The implant diameter had a significant influence on ang (p = 0.04), and the primary stability had a significant influence on h (p = 0.02). CONCLUSION: Template-guided implant placement offers a high degree of accuracy independent of the tooth area, the use of measures for alveolar ridge preservation or the implant configuration. A clinical benefit is therefore present, especially from a prosthetic point of view. TRIAL REGISTRATION: German Clinical Trial Register and the International Clinical Trials Registry Platform of the WHO: DRKS00005978 ; date of registration: 11/09/2015.


Asunto(s)
Proceso Alveolar/cirugía , Implantación Dental Endoósea , Implantes Dentales , Diente/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
4.
Lasers Surg Med ; 51(7): 653-663, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30843244

RESUMEN

OBJECTIVES: Diode lasers and the Nd:YAG laser are used in periodontal therapy and soft tissue surgery. Dental filling materials or cements might be inadvertently damaged. The underlying mechanism of the damage is based on the dental material's specific transmission and thus absorption behavior. MATERIALS AND METHODS: Twenty-four material representatives for composites, glass ionomer cements and other material classes (e.g., compomer) were processed to 100 µm and 200 µm planar specimens and spectroscopically measured for their collimated transmission in the photo spectrometer Varian Cary 5000. The (1) mean intensity of transmitted light was determined for the laser wavelengths of interest (810 nm, 940 nm, 980 nm, 1,064 nm) and used to calculate the (2) absorption lengths. RESULTS: The (1) mean intensity of transmitted light ranged between 9.51 % (Panavia F 2.0 for 810 nm) and 96.79% (Artegral Cem for 1,064 nm) for the composite specimens (100 µm) and was-with few exceptions-near zero for the representatives of glass ionomer cement and the other material classes. The (2) absorption lengths were between 0.06 mm (Panavia F 2.0 for all wavelengths of interest) and 1.33 mm (Coltène Duo Cement Plus for 1,064 nm) for the composites and below or equal 0.15 mm (PermaCem for 1,064 nm) for the few representatives of glass ionomer cements and the other material classes with mean intensities of transmitted light, which were not near zero and thus permitted to calculate absorption lengths. CONCLUSIONS: The transmission behavior varied between the different material classes and even within, albeit less pronounced. Composites generally showed the highest intensities of transmitted light and are thus least susceptible to surface damage by laser light (810 nm, 940 nm, 980 nm, 1,064 nm). The results can be used to improve and develop laser applications involving purposeful interactions between laser light and dental materials. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Resinas Compuestas/efectos de la radiación , Cementos Dentales/efectos de la radiación , Láseres de Semiconductores , Láseres de Estado Sólido , Absorción de Radiación , Resinas Compuestas/química , Cementos Dentales/química , Ensayo de Materiales
5.
Clin Oral Investig ; 22(7): 2439-2461, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29959596

RESUMEN

OBJECTIVES: The aim of the present study was a systematic review and subsequent meta-analysis on biological complications of removable prostheses in the moderately reduced dentition. MATERIALS AND METHODS: A systematic literature search in established medical databases (MEDLINE, EMBASE, BIOSIS, SciSearch, Cochrane, FIZ Technik Web) and a hand search of relevant dental journals was conducted. The search terms were relevant MeSH terms, free search terms, and combinations of the two. The search included randomized controlled trials, prospective and retrospective studies with data on biological complications of removable dental prostheses in the moderately reduced dentition with at least 15 participants, an observation period of at least 2 years, and a drop-out rate of less than 25%. The selection of relevant publications was carried out at the title, abstract, and full-text level by at least two of the authors involved. The publications included were tabulated and analyzed. RESULTS: Of the original 12,994 matches, 1923 were analyzed by title, 650 by abstract, and 111 according to the full text. A total of 42 publications were ultimately included. The following parameters were evaluated. TOOTH LOSS: Results varied, depending on the observation period, between 0 and 18.1% for clasp-retained removable dental prostheses (RDPs), between 5.5 and 29% for attachment-retained RDPs, and between 5.5 and 51.7% for double crown-retained RDPs. CARIES: Results varied, depending on the observation period, between 0 and 32.7% for clasp-retained RDPs, between 1.8 and 29% for attachment-retained RDPs, and between 1.8 and 16.4% for double crown-retained RDPs. ENDODONTIC TREATMENT: Results varied, depending on the observation period, between 3.5 and 19.2% for clasp-retained RDPs, between 6.9 and 16.4% for attachment-retained RDPs, and between 0.6 and 13.9% for double crown-retained RDPs. TOOTH FRACTURE: Results varied, depending on the observation period, between 1.7 and 5.3% for clasp-retained RDPs, between 12.7 and 40% for attachment-retained RDPs, and between 0.4 and 4.4% for double crown-retained RDPs. TOOTH MOBILITY: There were no changes or improvements for clasp-retained RDPs. The better the pre-treatment and supportive care is, the smaller the differences are. For double crown-retained RDPs, a slight increase was found in one study. The results for the parameters probing depth and radiological bone loss were inconclusive. GINGIVAL RECESSION: Gingival recession seemed to be favored by a mandibular sublingual bar. Compared to fixed restorations, removable restorations seemed to be associated with a more pronounced need for dental treatment. Stringent pre-treatment and supportive care reduced the complication rates. CONCLUSIONS: Heterogeneous study designs and data analyses rendered a meta-analysis impossible, so that an evaluation at the highest level of evidence could not be performed. CLINICAL RELEVANCE: Within the limitations of this study, it would be correct to state that removable dental prostheses require intensive maintenance. Suitable pre-treatment and supportive care can lower the complication rates, in the absence of which they constitute trigger factors for (additional) biological complications.


Asunto(s)
Dentadura Parcial Removible/efectos adversos , Arcada Parcialmente Edéntula , Retención de Prótesis Dentales , Humanos
6.
Clin Oral Investig ; 22(6): 2363-2372, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29356920

RESUMEN

OBJECTIVE: The aim of this study was to investigate differences between the virtually planned and clinically achieved implant positions in completely template-guided implantations as a function of the type of edentulous space, the residual natural dentition, and the surgical implementation. MATERIALS AND METHODS: Fifty-six patient cases with a total of 122 implants were evaluated retrospectively. The implantations were completely template-based. The data of the planned implant positions were overlaid with the actual clinical implant positions, followed by measurements of the 3D deviations in terms of coronal (xc) and apical distance, height (xh), and angulation (ang) and statistical analysis. RESULTS: The mean xc was 1.2 mm (SD 0.7 mm); the mean xa was 1.8 mm (SD 0.9 mm), the mean xh was 0.8 mm (SD 0.7 mm); and the mean ang was 4.8° (SD 3.1). The type of edentulous space and the jaw (maxilla/mandible) had no significant effect on the results in terms of implant positions. The presence of an adjacent natural tooth at the time of implantation had a significant influence on xh (p = 0.04) and ang (p = 0.05). No significant differences were found regarding the surgical approach for any of the parameters examined. CONCLUSION: The results of our study are in the same range as those of other studies. Template-guided implantation offers a high degree of accuracy even in the presence of different configurations of the residual dentition or different surgical approaches. A clinical benefit is therefore present, especially from a prosthetic point of view. CLINICAL RELEVANCE: The clinically achievable accuracy can be described as sufficient for further prosthetic treatment, given the intrinsic and methodological tolerances, making prosthetic rehabilitation safe and predictable.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea/métodos , Implantes Dentales , Imagenología Tridimensional/métodos , Cirugía Asistida por Computador/métodos , Simulación por Computador , Femenino , Humanos , Arcada Edéntula/rehabilitación , Masculino , Planificación de Atención al Paciente , Estudios Retrospectivos , Resultado del Tratamiento
7.
Int J Comput Dent ; 21(2): 97-105, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29967902

RESUMEN

OBJECTIVE: The insertion of implants through template-guided surgery is an established method. At the present time, the static navigation is based on sleeves integrated into the guides, through which drill bits of the corresponding size are passed. The present clinical trial is designed to test a new sleeveless system to determine the precision of implant insertion for one-piece ceramic implants. MATERIALS AND METHODS: For 12 patients, implant bed preparation and the insertion of the implants were done using a sleeveless implant guide. Twenty implants were inserted in this way and checked for precision. The check was done using a noninvasive method, which permitted comparison of the planning data with the actually realized positions after superimposition. RESULTS: The mean deviations were 0.52 mm (95% CI: 0.37 to 0.67 mm) at the crestal position of the implant, and 0.82 mm (95% CI: 0.56 to 1.08 mm) at the apical tip of the implant. The height deviation was 0.35 mm (95% CI: 0.01 to 0.68 mm). The mean angular deviation was measured as 2.85 degrees (95% CI: 2.18 to 3.51 degrees). CONCLUSION: The values showed good precision in all the parameters measured. The results were thus in a range equal to or better than the mean precision found in numerous clinical trials described in the literature. In particular, the method showed little deviation, as illustrated by the confidence interval (CI), but also by the clinically critical maximum deviations.


Asunto(s)
Implantación Dental Endoósea/instrumentación , Imagenología Tridimensional , Cirugía Asistida por Computador/instrumentación , Adulto , Anciano , Implantación Dental Endoósea/métodos , Implantes Dentales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
8.
Clin Oral Investig ; 20(7): 1435-47, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27283325

RESUMEN

OBJECTIVES: Evidence-based therapeutic recommendations for removable dental prostheses are still lacking. The aim of the present study was a systematic review and meta-analysis of the survival rates of removable dentures in the moderately reduced dentition. MATERIALS AND METHODS: In 2014, a systematic literature search in established medical databases (MEDLINE, EMBASE, BIOSIS, SciSearch, Cochrane, FIZ Technik Web) and a hand search of relevant dental journals were conducted. The search terms were relevant MeSH terms, free search terms, and combinations of the two. The search included RCTs, prospective and retrospective studies on survival rates of removable dental prostheses in the moderately reduced dentition with at least 15 participants, an observation period of at least 2 years, and a dropout rate of less than 25 %. The selection of relevant publications was carried out at the title, abstract, and full-text level by at least two of the authors involved. The publications included were tabulated and analyzed. RESULTS: Of the original 12,994 matches, 1923 were analyzed by title, 650 by abstract, and 111 according to the full text. The final review included 19 publications, of which 6 were multiple publications. Cast-metal framework dentures exhibited failure rates of between 33 and 50 % after 5 years. One study with a 25-year observation period reported failure rates of 50 %. Better results were obtained with proper pretreatment and a good recall scheme. Bilateral attachment prostheses showed failure rates of between 11 and 30 % after 5 years. Unilateral attachment prostheses showed failure rates of 75 % after 5 years. Double-crown prostheses dentures show failure rates of 0 to 21.7 % after 3 to 6 years. CONCLUSIONS: Heterogeneous study designs and data analyses rendered a meta-analysis impossible, so that an evaluation at the highest level of evidence could not be performed. CLINICAL RELEVANCE: Within the limitations of this study, it would be correct to state that removable dental prostheses, given suitable pretreatment and follow-up regimes, can provide satisfactory solutions. Based on only one paper, they revealed acceptable results even over a very long observation period (25 years).


Asunto(s)
Dentadura Parcial Removible , Arcada Parcialmente Edéntula/rehabilitación , Coronas , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Retención de Dentadura , Humanos
9.
Lasers Surg Med ; 45(5): 339-44, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23737101

RESUMEN

BACKGROUND AND OBJECTIVE: The aim of this in vitro study was to investigate the effect of Er:YAG laser irradiation on the ability of sodium hypochlorite (NaOCl) to dissolve soft tissue during endodontic procedures. MATERIALS AND METHODS: Two acrylic glass plates, each containing a semi-canal, were bolted together to form a complete canal. This geometry permitted one semi-canal to be filled with fine liver sausage of bovine origin dyed by methylene blue and the other with NaOCl (4.00-4.99% available chlorine; Sigma-Aldrich Corporation, St. Louis, MA), which was then activated by Er:YAG laser irradiation (KEY Laser 3; KaVo, Biberach, Germany) using a plain-ended fiber tip and a range of output energy and repetition rate. To achieve relatively low output energy from high input energy, the laser beam was attenuated by placing glass slides in the beam path. The resultant images acquired were analyzed using pixel-based analysis. Samples were statistically analyzed (two-way ANOVA, P < 0.05, univariate, bifactorial; IBM SPSS Statistics 19, SPSS Inc., Chicago, IL). RESULTS: Both output energy and repetition rate significantly influenced the tissue dissolution ability of NaOCl (P < 0.05). CONCLUSION: Within the limitations of this in vitro study, we conclude that laser activation of NaOCl at 200 mW output power leads to effective soft tissue dissolution. This finding can be of use to endodontists pursuing effective soft tissue dissolution from their irrigants.


Asunto(s)
Cavidad Pulpar/efectos de la radiación , Láseres de Estado Sólido/uso terapéutico , Terapia por Luz de Baja Intensidad , Irrigantes del Conducto Radicular/uso terapéutico , Tratamiento del Conducto Radicular , Hipoclorito de Sodio/uso terapéutico , Animales , Bovinos , Cavidad Pulpar/efectos de los fármacos , Modelos Biológicos
10.
Clin Oral Investig ; 17(5): 1397-406, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22936298

RESUMEN

OBJECTIVES: The use of fast-setting impression materials with different viscosities for the one-stage impression technique demands precise working times when mixing. We examined the effect of varying working time on impression precision in a randomized clinical trial. MATERIALS AND METHODS: Focusing on tooth 46, three impressions were made from each of 96 volunteers, using either a polyether (PE: Impregum Penta H/L DuoSoft Quick, 3 M ESPE) or an addition-curing silicone (AS: Aquasil Ultra LV, Dentsply/DeTrey), one with the manufacturer's recommended working time (used as a reference) and two with altered working times. All stages of the impression-taking were subject to randomization. The three-dimensional precision of the non-standard working time impressions was digitally analyzed compared to the reference impression. Statistical analysis was performed using multivariate models. RESULTS: The mean difference in the position of the lower right first molar (vs. the reference impression) ranged from ±12 µm for PE to +19 and -14 µm for AS. Significantly higher mean values (+62 to -40 µm) were found for AS compared to PE (+21 to -26 µm) in the area of the distal adjacent tooth. CONCLUSIONS: Fast-set impression materials offer high precision when used for single tooth restorations as part of a one-stage impression technique, even when the working time (mixing plus application of the light- and heavy-body components) diverges significantly from the manufacturer's recommended protocol. CLINICAL RELEVANCE: Best accuracy was achieved with machine-mixed heavy-body/light-body polyether. Both materials examined met the clinical requirements regarding precision when the teeth were completely syringed with light material.


Asunto(s)
Materiales de Impresión Dental , Técnica de Impresión Dental , Precisión de la Medición Dimensional , Modelos Dentales , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Técnica de Impresión Dental/instrumentación , Método Doble Ciego , Femenino , Humanos , Imagenología Tridimensional , Masculino , Mandíbula , Ensayo de Materiales , Persona de Mediana Edad , Modelos Estadísticos , Diente Molar , Análisis Numérico Asistido por Computador , Polivinilos , Estudios Prospectivos , Resinas Sintéticas , Siloxanos , Estadísticas no Paramétricas , Factores de Tiempo , Viscosidad , Adulto Joven
11.
Dent J (Basel) ; 11(2)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36826200

RESUMEN

The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated 06/2022, was conducted. RCTs and prospective and retrospective studies were included that had information on technical complications and failures of RPDs, at least 15 participants, an observation period of at least two years and a drop-out rate of less than 25%. Publications were selected on the title, abstract and full-text level by at least three of the participating authors. The evidence of the included studies was classified using the GRADE system. The bias risk was determined using the RoB2 tool and the ROBINS-I tool. Of 19,592 initial hits, 43 publications were included. Predominantly, retention of the prosthesis, retention loss of anchor crowns (decementations), fractures/repairs of frameworks, denture teeth, veneering or acrylic bases, and a need for relining were reported depending on prosthesis type and observation time. Focusing on technical complications and failures, only very heterogeneous data were found and publications with the highest quality level according to GRADE were scarce. Whenever possible, data on technical complications and failures should be reported separately when referencing the tooth, the prosthesis and the patient for comparability. Prostheses with differing anchorage types should be analyzed in different groups, as the respective complications and failures differ. A precise description of the kinds of complications and failures, as well as of the resulting follow-up treatment measures, should be given.

12.
J Clin Med ; 12(22)2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-38002627

RESUMEN

Vertical ridge augmentation is a demanding and technique-sensitive surgical procedure. In the present case series, cone beam CT (CBCT) scans from the clinical routine of patients treated using a novel approach for vertical bone augmentation were assessed. All patients showed a single-tooth class 5 defect and were treated using a modification of the original shell technique. Cortical bone plates were replaced with a lamina composed of a partially demineralized porcine xenograft. CBCT scans of six consecutive patients were treated with the lamina and particulate bone from the mandibular ramus prior to a single tooth implant in the anterior maxilla were included. Pre- and postsurgical CBCT data sets were superimposed and analyzed digitally using surface matching and Boolean subtraction. The volume of the grafted area was calculated with and without the xenograft. The vertical gain of the ridge height measured in this case series varied from 7 to 11.3 mm. The mean vertical gain was 8.97 mm. The mean volume including the xenograft was 382.59 mm3 (SD 73.39) and 250.84 mm3 (SD 53.67) without the lamina. The modified shell technique used in this case series for the vertical augmentation of single-tooth class 5 defects provided sufficient bone for single implant restorations.

13.
Comput Biol Med ; 148: 105861, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35940160

RESUMEN

BACKGROUND: As manual cell counting lacks objectivity in the assessment of positive marker cells in immunohistologic sections, there has been a shift to automated computer analysis solutions. However, quantifying inflammation around dental implants is still often done by manual cell counting. METHOD: With mucosal sections stained against MRP8 harvested around dental implants, we developed an automated method (AM) to identify positive marker cells. In this proof-of-concept study, we developed a procedure for its validation on an exemplary data set. Therefore, the sections were also analyzed with the manual method (MM). Intrarater and interrater reliability as well as time analyses were conducted. RESULTS: The newly developed AM was based on a color deconvolution in the open-source software ImageJ2. We embedded the determination of the most appropriate filter setting into the systematic validation procedure, implementing the intraclass correlation (ICC) and the Bland-Altman bias (BA). The newly developed validation procedure carried out on the data set of this proof-of-concept study resulted in an excellent reliability of the AM (ICC = 0.97). Both the reliability and time analyses' results were in favor of the AM. CONCLUSION: Our newly developed AM showed advantages in terms of repeatability and objectivity combined with a shorter duration. The detailed descriptions of its application and its validation procedure offers the opportunity to apply it for further immunohistologic questions. The prerequisite for the replacement of the MM is that the validation, carried out on a sufficient number of samples, leads to satisfactory results.


Asunto(s)
Implantes Dentales , Biomarcadores , Computadores , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Programas Informáticos
14.
J Clin Med ; 11(2)2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-35054131

RESUMEN

This randomized clinical study aimed at quantifying the gingival displacement performance in the vertical and horizontal directions of the 3M™ Astringent Retraction Paste (3M Oral Care, Seefeld, Germany) in comparison with the double-cord technique with aluminum chloride as an astringent. Afterward, any soft-tissue changes were assessed for 12 months. After inducing mild gingivitis, 18 probands received the intervention 'cord' and 22 probands received the intervention 'paste' at the palatal half of upper premolars prior to conventional impression making. The resulting plaster casts were digitized and analyzed for the vertical and horizontal gingival displacement, applying a newly developed computer-assisted methodology. The entire palatal half of the tooth was evaluated instead of only single sites. Under the condition of mild gingivitis, the gingival displacement performance was comparable for both techniques in the horizontal direction (width) and only somewhat better for the cord technique in the vertical direction (depth). The magnitude of displacement was in a similar range in both directions, with somewhat higher values in the vertical direction. The marginal gingiva height changes were of such low extent during the follow-up period of 12 months with only minimally higher values for the paste that they cannot be considered as clinically relevant recessions.

15.
Int J Prosthodont ; 35(4): 442­452, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33750996

RESUMEN

PURPOSE: To test the bond strength of one-piece zirconia implants with either standard or reduced height using different luting agents and pretreatments of the ceramic crowns' inner surfaces. MATERIALS AND METHODS: Twenty monolithic CAD/CAM-fabricated zirconia single crowns were cemented onto 10 one-piece zirconia implants with either 5-mm or 4-mm abutment height (Z-Look3 Evo SLM, Z-Systems) using 13 different luting agents. After water storage, the crowns were removed using a specially developed test fixture in a universal testing machine (Z010, Zwick/Roell). The maximum force was recorded (N), and the force per area was calculated (MPa). The statistical evaluation was performed using univariate analysis of variance (SPSS version 25.0, IBM). RESULTS: A mean of 4.19 MPa (SD 2.90) at 5 mm and 3.89 MPa (SD 2.85) at 4 mm was obtained for all luting agents. The highest values were achieved for a resinmodified glass-ionomer cement, with 12.37 MPa (4 mm)/12.00 MPa (5mm). The lowest values were shown for a long-term temporary material, with 0.73 MPa (4 mm)/1.07 MPa (5 mm). Only a polycarboxylate cement (P < .001) and a glass-ionomer cement (P = .006) showed statistically significant differences, in favor of the reduced abutment height. The latter did not significantly reduce bond strength for any of the materials examined. CONCLUSION: Implants with a reduced abutment height are clinically suitable. Pretreatment of the crowns' inner surfaces with ceramic primer showed to be advantageous.

16.
Int J Implant Dent ; 7(1): 42, 2021 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-33899126

RESUMEN

BACKGROUND: An implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors. The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study. MATERIAL AND METHODS: In this prospective clinical study, 20 implants were placed in 20 patients. The implant had a pronounced conical outer geometry (Conelog ProgressiveLine, Camlog Wimsheim, Germany). Data from a study using an implant with a distinct cylindrical outer geometry were used as a comparison group (Conelog ScrewLine, Camlog, Wimsheim, Germany). The clinically achieved implant position was compared with the planned position. RESULTS: The evaluation of the two-dimensional deviations in direction resulted in the following mean values (standard deviation) at the shoulder: 0.42 mm (0.33) in the buccolingual direction, 0.27 mm (0.25) in the mesiodistal direction, and 0.68 mm (0.55) in the apicocoronal direction. The mean angular deviation was 4.1° (2.3). The three-dimensional (3D) deviation was 0.94 mm (0.53) at the shoulder and 1.36 mm (0.62) at the apex of the implant. Significant differences between implants with different macro designs were found in the apicocoronal direction. In connection to this, a significant 3D deviation was found at the implant shoulder. CONCLUSIONS: Significant differences in height were found between the groups. The study had shown that the macro design of an implant has no influence on accuracy in all other directions. Overall, the implants showed a high level of accuracy and a low variation in values. The values were in the range determined by the template-guided insertion system in numerous other investigations. This provides good predictability of prosthetic rehabilitation. TRIAL REGISTRATION: German Register for Clinical Studies (DRKS-ID: DRKS000018939 ). Date of registration: November 11, 2019.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Humanos , Estudios Prospectivos , Prótesis e Implantes
17.
Dent J (Basel) ; 9(5)2021 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-34068734

RESUMEN

(1) Background: The objective of implant prosthetic restoration is to ensure the best possible rehabilitation of function and esthetics. Optimal positioning of the implant with regard to the bone availability, surrounding soft tissue, and prosthetic sustainability should be strived for during implant placement. The factors influencing freehand implant placement and the accuracy achieved with this procedure are investigated in this prospective clinical study. (2) Methods: Implants were placed in the single-tooth edentulous sites of the premolar and molar areas in 52 patients. Three-dimensional (3D)-planning was performed virtually prior to the freehand implant operation, and the desired position of the implant was provided to the surgeon. (3) Results: The deviations between the planned and the actually achieved position with freehand implant placement showed the following mean values and standard deviations: angle 8.7 ± 4.8°, 3D deviation at the implant shoulder 1.62 ± 0.87 mm, mesiodistal deviation 0.87 ± 0.75 mm, buccolingual deviation 0.70 ± 0.66 mm, and apiocoronal deviation 0.95 ± 0.61 mm. The type of jaw had a significant influence on accuracy. Major deviations were observed in the lower jaw. Furthermore, the timing of implant placement influenced the mesiodistal deviation and angular deviation; (4) Conclusions: Freehand implant placement demonstrated a higher level of deviation between the planned and actually achieved implant positions. In particular, the ranges showed a large spread. From a prosthetic point of view, there may be complications during the restoration of the prosthetic crown if the implant exit point is not optimally located or if the implants show a high angular deviation.

18.
J Clin Med ; 10(13)2021 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-34206670

RESUMEN

This randomized clinical study examined the influence of the gingival condition-healthy versus mild inflammation-on sulcus representation and possible gingival recession for two gingival displacement procedures prior to conventional impression making. The interventions double cord technique or a kaolin paste containing aluminum chloride were applied to 40 probands. The opposite quadrant served as intrapersonal reference (split-mouth design). Precision impressions were then made. Extraoral digitization of the plaster models resulting from the reference impression prior to gingival displacement, the intervention impression and control impressions were the basis for the computer-aided three-dimensional analysis. After six months, a mild artificial gingivitis was induced, and the contralateral quadrant (cross-over design) was examined for the intervention. The gingivitis deteriorated the sulcus representation for the double cord technique group but did not affect the paste technique group. The gingival condition had no influence on the marginal gingiva height changes. The minor extent of those changes, which were measured up to six months after intervention at the palatal study site, were not considered to be in the clinically relevant range for gingival recession. For healthy gingiva, the cord technique showed superior sulcus representation compared to the paste technique. This advantage was lost to a great extent under the conditions of mild gingivitis.

19.
Dent J (Basel) ; 8(4)2020 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-33023224

RESUMEN

BACKGROUND: The objective of this investigation was to examine whether determination of bone density (BD) with a cone beam computed tomography (CBCT) scan could help predict the primary stability (PS) of the implants and to investigate whether associations between the histomorphometric findings and the CBCT scan could be observed. MATERIALS AND METHODS: In this randomized clinical study, the efficacy of alveolar ridge preservation (ARP) with a combination of a collagen cone and a collagen membrane procedure after tooth extraction was investigated. CBCT scans were obtained after a healing period of 8 (±1) weeks. Subsequently, the CBCT scans were evaluated in terms of BD at different heights of the former socket. Eleven (±1) weeks after tooth extraction, implant placement was performed and PS was measured with resonance frequency analysis. Potential associations among the radiologically measured BD, the histomorphometric results, and the PS were analyzed. RESULTS: No direct association was observed between the radiologically determined BD and the histomorphometric findings. No significant associations could be found between the BD and the PS. CONCLUSION: No significant associations were observed among the BD determined by the CBCT, the histomorphometric findings, and the PS.

20.
Clin Exp Dent Res ; 6(3): 345-355, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31967736

RESUMEN

OBJECTIVES: The objective of the present study was to examine the influence of a combination material of a collagen cone and a collagen membrane on the healing process of extraction sockets with regard to histological, histochemical, and immunohistochemical parameters. MATERIALS AND METHODS: In a prospective randomized clinical study, 10 patients (test group) received a collagen combination material after tooth removal. The extraction sockets of 10 other patients (control group) were left to heal without further intervention. Eleven ±1 weeks after tooth extraction, histological biopsies were performed in both groups at the time of implant placement. Subsequently, the biopsies were evaluated semiquantitatively in terms of histological, histochemical, and immunohistochemical parameters for the identification of factors of bone metabolism and vascularization. RESULTS: No significant difference between test and control group were found for any parameter. According to the descriptive data, the use of a collagen combination material seems to result in slightly higher values of the osteogenic Runt-related transcription factor 2 (Runx2) and vascularization. CONCLUSION: The histological, histochemical, and immunohistochemical analysis of ARP with a collagen cone combined with a collagen membrane showed no significant differences in terms of bone metabolism and vascularization.


Asunto(s)
Pérdida de Hueso Alveolar/cirugía , Proceso Alveolar/cirugía , Aumento de la Cresta Alveolar/métodos , Colágeno/química , Tratamientos Conservadores del Órgano/métodos , Extracción Dental/métodos , Alveolo Dental/fisiología , Adulto , Anciano , Regeneración Ósea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA