Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Wound Repair Regen ; 28(6): 856-866, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32789935

RESUMEN

The aim of this study is to ascertain whether the simultaneous measurement of hemoglobin O2 saturation (StO2 ) and dimension of venous leg ulcers (VLU) by near infrared spectroscopy (NIRS) imaging can predict the healing course with protocols employing a conventional treatment alone or in combination with hyperbaric oxygen therapy (HBOT). NIRS 2D images of wound region were obtained in 81 patients with hard-to-heal VLU that had been assigned, in a randomized controlled clinical trial, to the following protocols: 30 HBOT sessions, adjunctive to the conventional therapy, either twice daily over 3 weeks (group A) or once daily over 6 weeks (group B), and conventional therapy without HBOT (group C). Seventy-three patients completed the study with a total of 511 NIRS images being analyzed. At the end of treatment, wound area was significantly smaller in all three groups. However, at the 3-week mark the wound area reduction tended to be less evident in group A than in the other groups. This trend continued up to the 6-week end-point when a significantly greater area reduction was found with group B (65.5%) and group C (56.8%) compared to group A (29.7%) (P < .01). Furthermore, a higher incidence of complete healing was noted with group B (20%) than with group A (4.5%) and group C (3.8%). When using a final wound reduction in excess of 40% to distinguish healing from nonhealing ulcers, it was found that only the former present NIRS StO2 values abating over the study period both at center and edge of lesions. In conclusion, NIRS analysis of StO2 and wound area can predict the healing course of VLU. Adjunctive HBOT significantly facilitates VLU healing compared to the conventional treatment alone. This positive action, however, becomes manifest only with a longer and less intensive treatment schedule.


Asunto(s)
Vendajes de Compresión , Hemoglobinas/metabolismo , Oxigenoterapia Hiperbárica/métodos , Espectroscopía Infrarroja Corta/métodos , Úlcera Varicosa/terapia , Cicatrización de Heridas/fisiología , Anciano , Biomarcadores/sangre , Femenino , Humanos , Masculino , Consumo de Oxígeno , Resultado del Tratamiento , Úlcera Varicosa/sangre
2.
Sensors (Basel) ; 17(12)2017 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-29257113

RESUMEN

Wound assessment is usually performed in hospitals or specialized labs. However, since patients spend most of their time at home, a remote real time wound monitoring would help providing a better care and improving the healing rate. This review describes the advances in sensors and biosensors for monitoring the concentration of C-reactive protein (CRP), temperature and pH in wounds. These three parameters can be used as qualitative biomarkers to assess the wound status and the effectiveness of therapy. CRP biosensors can be classified in: (a) field effect transistors, (b) optical immunosensors based on surface plasmon resonance, total internal reflection, fluorescence and chemiluminescence, (c) electrochemical sensors based on potentiometry, amperometry, and electrochemical impedance, and (d) piezoresistive sensors, such as quartz crystal microbalances and microcantilevers. The last section reports the most recent developments for wearable non-invasive temperature and pH sensors suitable for wound monitoring.


Asunto(s)
Técnicas Biosensibles , Proteína C-Reactiva , Humanos , Resonancia por Plasmón de Superficie , Temperatura , Cicatrización de Heridas
3.
Artículo en Inglés | MEDLINE | ID: mdl-37481789

RESUMEN

Variations in salivary short-chain fatty acids and hydroxy acids (e.g., lactic acid, and 3-hydroxybutyric acid) levels have been suggested to reflect the dysbiosis of human gut microbiota, which represents an additional factor involved in the onset of heart failure (HF) disease. The physical-chemical properties of these metabolites combined with the complex composition of biological matrices mean that sample pre-treatment procedures are almost unavoidable. This work describes a reliable, simple, and organic solvent free protocol for determining short-chain fatty acids and hydroxy acids in stimulated saliva samples collected from heart failure, obese, and hypertensive patients. The procedure is based on in-situ pentafluorobenzyl bromide (PFB-Br) derivatization and HiSorb sorptive extraction coupled to thermal desorption and gas chromatography-tandem mass spectrometry. The HiSorb extraction device is completely compatible with aqueous matrices, thus saving on time and materials associated with organic solvent-extraction methods. A Central Composite Face-Centred experimental design was used for the optimization of the molar ratio between PFB-Br and target analytes, the derivatization temperature, and the reaction time which were 100, 60 °C, and 180 min, respectively. Detection limits in the range 0.1-100 µM were reached using a small amount of saliva (20 µL). The use of sodium acetate-1-13C as an internal standard improved the intra- and inter-day precision of the method which ranged from 10 to 23%. The optimized protocol was successfully applied for what we believe is the first time to evaluate the salivary levels of short chain fatty acids and hydroxy acids in saliva samples of four groups of patients: i) patients admitted to hospital with acute HF symptoms, ii) patients with chronic HF symptoms, iii) patients without HF symptoms but with obesity, and iv) patients without HF symptoms but with hypertension. The first group of patients showed significantly higher levels of salivary acetic acid and lactic acid at hospital admission as well as the lowest values of hexanoic acid and heptanoic acid. Moreover, the significant high levels of acetic acid, propionic acid, and butyric acid observed in HF respect to the other patients suggest the potential link between oral bacteria and gut dysbiosis.


Asunto(s)
Insuficiencia Cardíaca , Hidroxiácidos , Humanos , Hidroxiácidos/análisis , Disbiosis , Cromatografía de Gases y Espectrometría de Masas/métodos , Ácidos Grasos Volátiles/análisis , Ácido Acético , Ácido Butírico , Ácido Láctico/análisis , Ácidos Grasos
4.
Free Radic Biol Med ; 201: 55-65, 2023 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-36940734

RESUMEN

Cardiovascular diseases (CVDs) are the leading cause of premature death and disability in humans and their incidence continues to increase. Oxidative stress and inflammation have been recognized as key pathophysiological factors in cardiovascular events. The targeted modulation of the endogenous mechanisms of inflammation, rather than its simple suppression, will become key in treating chronic inflammatory diseases. A comprehensive characterization of the signalling molecules involved in inflammation, such as endogenous lipid mediators, is thus needed. Here, we propose a powerful MS-based platform for the simultaneous quantitation of sixty salivary lipid mediators in CVD samples. Saliva, which represents a non-invasive and painless alternative to blood, was collected from patients suffering from acute and chronic heart failure (AHF and CHF, respectively), obesity and hypertension. Of all the patients, those with AHF and hypertension showed higher levels of isoprostanoids, which are key indexes of oxidant insult. Compared to the obese population, AHF patients showed lower levels (p < 0.02) of antioxidant omega-3 fatty acids, in line with the "malnutrition-inflammation complex syndrome" typical of HF patients. At hospital admission, AHF patients showed significantly higher levels (p < 0.001) of omega-3 DPA and lower levels (p < 0.04) of lipoxin B4 than CHF patients, suggesting a lipid rearrangement typical of the failing heart during acute decompensation. If confirmed, our results highlight the potential use of lipid mediators as predictive markers of re-acutisation episodes, thus providing opportunities for preventive intervention and a reduction in hospitalizations.


Asunto(s)
Enfermedades Cardiovasculares , Ácidos Grasos Omega-3 , Insuficiencia Cardíaca , Hipertensión , Humanos , Inflamación , Enfermedad Crónica , Obesidad , Mediadores de Inflamación
5.
Life (Basel) ; 13(9)2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37763222

RESUMEN

BACKGROUND: Serum natriuretic peptides (NPs) have an established role in heart failure (HF) diagnosis. Saliva NT-proBNP that may be easily acquired has been studied little. METHODS: Ninety-nine subjects were enrolled; thirty-six obese or hypertensive with dyspnoea but no echocardiographic HF findings or raised NPs served as controls, thirteen chronic HF (CHF) patients and fifty patients with acute decompensated HF (ADHF) requiring hospital admission. Electrocardiogram, echocardiogram, 6 min walking distance (6MWD), blood and saliva samples, were acquired in all participants. RESULTS: Serum NT-proBNP ranged from 60-9000 pg/mL and saliva NT-proBNP from 0.64-93.32 pg/mL. Serum NT-proBNP was significantly higher in ADHF compared to CHF (p = 0.007) and in CHF compared to controls (p < 0.05). There was no significant difference in saliva values between ADHF and CHF, or between CHF and controls. Saliva and serum levels were positively associated only in ADHF patients (R = 0.352, p = 0.012). Serum NT-proBNP was positively associated with NYHA class (R = 0.506, p < 0.001) and inversely with 6MWD (R = -0.401, p = 0.004) in ADHF. Saliva NT-proBNP only correlated with age in ADHF patients. CONCLUSIONS: In the current study, saliva NT-proBNP correlated with serum values in ADHF patients, but could not discriminate between HF and other causes of dyspnoea. Further research is needed to explore the value of saliva NT-proBNP.

6.
J Breath Res ; 16(2)2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35051905

RESUMEN

The composition of exhaled breath derives from an intricate combination of normal and abnormal physiological processes that are modified by the consumption of food and beverages, circadian rhythms, bacterial infections, and genetics as well as exposure to xenobiotics. This complexity, which results wide intra- and inter-individual variability and is further influenced by sampling conditions, hinders the identification of specific biomarkers and makes it difficult to differentiate between pathological and nominally healthy subjects. The identification of a 'normal' breath composition and the relative influence of the aforementioned parameters would make breath analyses much faster for diagnostic applications. We thus compared, for the first time, the breath composition of age-matched volunteers following a vegan and a Mediterranean omnivorous diet in order to evaluate the impact of diet on breath composition. Mixed breath was collected from 38 nominally healthy volunteers who were asked to breathe into a 2 l handmade Nalophan bag. Exhalation flow rate and carbon dioxide values were monitored during breath sampling. An aliquot (100 ml) of breath was loaded into a sorbent tube (250 mg of Tenax GR, 60/80 mesh) before being analyzed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Breath profiling using TD-GC-MS analysis identified five compounds (methanol, 1-propanol, pentane, hexane, and hexanal), thus enabling differentiation between samples collected from the different group members. Principal component analysis showed a clear separation between groups, suggesting that breath analysis could be used to study the influence of dietary habits in the fields of nutrition and metabolism. Surprisingly, one Italian woman and her brother showed extremely low breath isoprene levels (about 5 pbv), despite their normal lipidic profile and respiratory data, such as flow rate and pCO2. Further investigations to reveal the reasons behind low isoprene levels in breath would help reveal the origin of isoprene in breath.


Asunto(s)
Dieta Vegana , Compuestos Orgánicos Volátiles , Biomarcadores/análisis , Pruebas Respiratorias/métodos , Espiración , Femenino , Cromatografía de Gases y Espectrometría de Masas , Humanos , Masculino , Compuestos Orgánicos Volátiles/análisis
7.
Ital J Dermatol Venerol ; 157(2): 187-194, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34498454

RESUMEN

BACKGROUND: Lower limb ulcers not responding to standard treatments after 8 weeks are defined as chronic wounds, and they are a significant medical problem. Blue light (410-430 nm) proved to be effective in treating wounds, but there is a lack of data on chronic wounds in clinical practice. The aim of the study was to determine if blue light photobiomodulation with EmoLED (Emoled Srl, Sesto Fiorentino, Florence, Italy) medical device in addition to standard of care is more effective compared to standard of care alone in promoting re-epithelialization of chronic wounds of lower limbs in 10 weeks. METHODS: Ninety patients affected by multiple or large area ulcers were enrolled. To minimize all variabilities, each patient has been used as control of himself. Primary endpoint was the comparison of the re-epithelialization rate expressed as a percentage of the difference between the initial and final area. Secondary endpoints were: treatment safety, pain reduction, wound area reduction trend over time, healing rate. RESULTS: At week 10, the wounds treated with EmoLED in addition to standard care showed a smaller residual wound area compared to the wounds treated with standard of care alone: 42.1% vs. 63.4% (P=0.029). The difference is particularly evident in venous leg ulcers, 33.3% vs. 60.1% (P=0.007). 17 treated wounds and 12 controls showed complete healing at week 10. Patients showed a significant reduction in pain (P=2×10-7). CONCLUSIONS: Blue light treatment in addition to standard of care accelerates consistently the re-epithelialization rate of chronic wounds, especially venous leg ulcers and increases the chances of total wound healing in 10 weeks.


Asunto(s)
Terapia por Luz de Baja Intensidad , Úlcera Varicosa , Humanos , Dolor , Úlcera , Úlcera Varicosa/radioterapia , Cicatrización de Heridas
8.
J Breath Res ; 15(3)2021 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-33752195

RESUMEN

COVID-19 is a highly transmissible respiratory illness that has rapidly spread all over the world causing more than 115 million cases and 2.5 million deaths. Most epidemiological projections estimate that the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus causing the infection will circulate in the next few years and raise enormous economic and social issues. COVID-19 has a dramatic impact on health care systems and patient management, and is delaying or stopping breath research activities due to the risk of infection to the operators following contact with patients, potentially infected samples or contaminated equipment. In this scenario, we investigated whether virus inactivation procedures, based on a thermal treatment (60 °C for 1 h) or storage of tubes at room temperature for 72 h, could be used to allow the routine breath analysis workflow to carry on with an optimal level of safety during the pandemic. Tests were carried out using dry and humid gaseous samples containing about 100 representative chemicals found in exhaled breath and ambient air. Samples were collected in commercially available sorbent tubes, i.e. Tenax GR and a combination of Tenax TA, Carbograph 1TD and Carboxen 1003. Our results showed that all compounds were stable at room temperature up to 72 h and that sample humidity was the key factor affecting the stability of the compounds upon thermal treatment. Tenax GR-based sorbent tubes were less impacted by the thermal treatment, showing variations in the range 20%-30% for most target analytes. A significant loss of aldehydes and sulphur compounds was observed using carbon molecular sieve-based tubes. In this case, a dry purge step before inactivation at 60 °C significantly reduced the loss of the target analytes, whose variations were comparable to the method variability. Finally, a breath analysis workflow including a SARS-CoV-2 inactivation treatment is proposed.


Asunto(s)
Pruebas Respiratorias/instrumentación , COVID-19/virología , SARS-CoV-2/fisiología , Inactivación de Virus , Compuestos Orgánicos Volátiles/química , Pruebas Respiratorias/métodos , Humanos , Pandemias , Manejo de Especímenes/métodos , Temperatura , Compuestos Orgánicos Volátiles/análisis
9.
ACS Appl Mater Interfaces ; 13(26): 30245-30260, 2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34167302

RESUMEN

Notwithstanding its relatively recent discovery, graphene has gone through many evolution steps and inspired a multitude of applications in many fields, from electronics to life science. The recent advancements in graphene production and patterning, and the inclusion of two-dimensional (2D) graphenic materials in three-dimensional (3D) superstructures, further extended the number of potential applications. In this Review, we focus on laser-induced graphene (LIG), an intriguing 3D porous graphenic material produced by direct laser scribing of carbonaceous precursors, and on its applications in chemical sensors and biosensors. LIG can be shaped in different 3D forms with a high surface-to-volume ratio, which is a valuable characteristic for sensors that typically rely on phenomena occurring at surfaces and interfaces. Herein, an overview of LIG, including synthesis from various precursors, structure, and characteristic properties, is first provided. The discussion focuses especially on transport and surface properties, and on how these can be controlled by tuning the laser processing. Progresses and trends in LIG-based chemical sensors are then reviewed, discussing the various transduction mechanisms and different LIG functionalization procedures for chemical sensing. A comparative evaluation of sensors performance is then provided. Finally, sensors for glucose detection are reviewed in more detail, since they represent the vast majority of LIG-based chemical sensors.

10.
J Pharm Biomed Anal ; 192: 113645, 2021 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-33039910

RESUMEN

A main challenge in the development of biosensing devices for the identification and quantification of nucleic acids is to avoid the amplification of the genetic material from the sample by polymerase chain reaction (PCR), which is at present necessary to enhance sensitivity and selectivity of assays. PCR has undoubtedly revolutionized genetic analyses, but it requires careful purification procedures that are not easily implemented in point of care (POC) devices. In recent years, a new strategy for nucleic acid detection based on clustered regularly interspaced short palindromic repeats (CRISPR) and associated protein systems (Cas) seems to offer unprecedented possibilities. The coupling of the CRISPR/Cas system with recent isothermal amplification methods is fostering the development of innovative optical and electrochemical POC devices. In this review, the mechanisms of action of several new CRISRP/Cas systems are reported together with their use in biosensing of nucleic acids.


Asunto(s)
Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas , Ácidos Nucleicos , Sistemas CRISPR-Cas/genética , Ácidos Nucleicos/genética , Sistemas de Atención de Punto
11.
Sci Rep ; 11(1): 13088, 2021 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-34158583

RESUMEN

Heart failure (HF) is the main cause of mortality worldwide, particularly in the elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) is the gold standard biomarker for HF diagnosis and therapy monitoring. It is determined in blood samples by the immunochemical methods generally adopted by most laboratories. Saliva analysis is a powerful tool for clinical applications, mainly due to its non-invasive and less risky sampling. This study describes a validated analytical procedure for NT-proBNP determination in saliva samples using a commercial Enzyme-Linked Immuno-Sorbent Assay. Linearity, matrix effect, sensitivity, recovery and assay-precision were evaluated. The analytical approach showed a linear behaviour of the signal throughout the concentrations tested, with a minimum detectable dose of 1 pg/mL, a satisfactory NT-proBNP recovery (95-110%), and acceptable precision (coefficient of variation ≤ 10%). Short-term (3 weeks) and long-term (5 months) stability of NT-proBNP in saliva samples under the storage conditions most frequently used in clinical laboratories (4, - 20, and - 80 °C) was also investigated and showed that the optimal storage conditions were at - 20 °C for up to 2.5 months. Finally, the method was tested for the determination of NT-proBNP in saliva samples collected from ten hospitalized acute HF patients. Preliminary results indicate a decrease in NT-proBNP in saliva from admission to discharge, thus suggesting that this procedure is an effective saliva-based point-of-care device for HF monitoring.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico/análisis , Péptido Natriurético Encefálico/inmunología , Fragmentos de Péptidos/análisis , Fragmentos de Péptidos/inmunología , Anciano , Anciano de 80 o más Años , Biomarcadores/análisis , Pruebas Diagnósticas de Rutina , Ensayo de Inmunoadsorción Enzimática/métodos , Femenino , Voluntarios Sanos , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/metabolismo , Fragmentos de Péptidos/metabolismo , Estabilidad Proteica , Saliva/química , Manejo de Especímenes/métodos
12.
Diagnostics (Basel) ; 11(5)2021 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-34063278

RESUMEN

The aim of this study was to perform a systematic review on the potential value of saliva biomarkers in the diagnosis, management and prognosis of heart failure (HF). The correlation between saliva and plasma values of these biomarkers was also studied. PubMed was searched to collect relevant literature, i.e., case-control, cross-sectional studies that either compared the values of salivary biomarkers among healthy subjects and HF patients, or investigated their role in risk stratification and prognosis in HF patients. No randomized control trials were included. The search ended on 31st of December 2020. A total of 15 studies met the inclusion criteria. 18 salivary biomarkers were analyzed and the levels of all biomarkers studied were found to be higher in HF patients compared to controls, except for amylase, sodium, and chloride that had smaller saliva concentrations in HF patients. Natriuretic peptides are the most commonly used plasma biomarkers in the management of HF. Their saliva levels show promising results, although the correlation of saliva to plasma values is weakened in higher plasma values. In most of the publications, differences in biomarker levels between HF patients and controls were found to be statistically significant. Due to the small number of patients included, larger studies need to be conducted in order to facilitate the use of saliva biomarkers in clinical practice.

13.
Biosensors (Basel) ; 10(11)2020 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-33121071

RESUMEN

Lymphocytes (B, T and natural killer cells) and immunoglobulins are essential for the adaptive immune response against external pathogens. Flow cytometry and enzyme-linked immunosorbent (ELISA) kits are the gold standards to detect immunoglobulins, B cells and T cells, whereas the impedance measurement is the most used technique for natural killer cells. For point-of-care, fast and low-cost devices, biosensors could be suitable for the reliable, stable and reproducible detection of immunoglobulins and lymphocytes. In the literature, such biosensors are commonly fabricated using antibodies, aptamers, proteins and nanomaterials, whereas electrochemical, optical and piezoelectric techniques are used for detection. This review describes how these measurement techniques and transducers can be used to fabricate biosensors for detecting lymphocytes and the total content of immunoglobulins. The various methods and configurations are reported, along with the advantages and current limitations.


Asunto(s)
Técnicas Biosensibles , Inmunoglobulinas/análisis , Linfocitos , Anticuerpos , Aptámeros de Nucleótidos , Técnicas Electroquímicas , Humanos , Nanoestructuras
14.
Sci Rep ; 10(1): 7441, 2020 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-32366899

RESUMEN

Heart failure (HF) is a cardiovascular disease affecting about 26 million people worldwide costing about $100 billons per year. HF activates several compensatory mechanisms and neurohormonal systems, so we hypothesized that the concomitant monitoring of a panel of potential biomarkers related to such conditions might help predicting HF evolution. Saliva analysis by point-of-care devices is expected to become an innovative and powerful monitoring approach since the chemical composition of saliva mirrors that of blood. The aims of this study were (i) to develop an innovative procedure combining MEPS with UHPLC-MS/MS for the simultaneous determination of 8-isoprostaglandin F2α and cortisol in saliva and (ii) to monitor lactate, uric acid, TNF-α, cortisol, α-amylase and 8-isoprostaglandin F2α concentrations in stimulated saliva samples collected from 44 HF patients during their hospitalisation due to acute HF. Limit of detection of 10 pg/mL, satisfactory recovery (95-110%), and good intra- and inter-day precisions (RSD ≤ 10%) were obtained for 8-isoprostaglandin F2α and cortisol. Salivary lactate and 8-isoprostaglandin F2α were strongly correlated with NT-proBNP. Most patients (about 70%) showed a significant decrease (a factor of 3 at least) of both lactate and 8-isoprostaglandin F2α levels at discharge, suggesting a relationship between salivary levels and improved clinical conditions during hospitalization.


Asunto(s)
Biomarcadores/metabolismo , Dinoprost/análogos & derivados , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/metabolismo , Ácido Láctico/metabolismo , Saliva/metabolismo , Anciano , Área Bajo la Curva , Dinoprost/metabolismo , Hospitalización , Humanos , Límite de Detección , Persona de Mediana Edad , Proyectos Piloto , Curva ROC , Reproducibilidad de los Resultados
15.
Talanta ; 206: 120236, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31514837

RESUMEN

This work presents a reliable analytical procedure combining micro-extraction by packed sorbent (MEPS) and ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry to determine 8-iso prostaglandin F2α, 8-iso prostaglandin E2 and prostaglandin E2 in dried blood spots (DBSs). To reach this goal, we optimized a fast semi-automated MEPS procedure for the clean-up and pre-concentration of the analytes extracted from a single DBS (50 µL) by a 70:30 v/v methanol:water mixture. Limits of detection of about 20 pg mL-1, satisfactory recoveries (90-110%) and very good intra- and inter-day precisions (RSD ≤10%) were obtained for all the analytes. The innovative addition of internal standards on the filter paper before DBS sampling allowed to compensate changes in the amount of analyte during storage. Since prostanoids and isoprostanoids are biomarkers involved in the pathogenesis and progression of many diseases (e.g. ductal patency, diabetic nephropathy, and acute lung injury), our analytical method offers interesting diagnostic and prognostic opportunities in the medical field. The present method is currently used for the analysis of such biomarkers in DBSs from preterm newborns collected in the clinical setting.


Asunto(s)
Dinoprost/análogos & derivados , Dinoprostona/análogos & derivados , Dinoprostona/sangre , Pruebas con Sangre Seca/métodos , Isoprostanos/sangre , Biomarcadores/sangre , Cromatografía Líquida de Alta Presión/métodos , Dinoprost/sangre , Humanos , Recién Nacido , Límite de Detección , Microextracción en Fase Sólida/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos
16.
Talanta ; 200: 145-155, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31036166

RESUMEN

When working with humid gaseous samples, the amount of water vapour collected in a needle trap along with volatile analytes may vary from sample to sample and decrease during the storage. This has a major impact on desorption efficiency and recovery. We propose the addition of a labelled internal standards to nullify the effect of variable humidity on the analytical performance of needle trap micro-extraction combined with gas chromatography mass spectrometry. Triple-bed (Divinylbenzene/Carbopack X/Carboxen 1000) and single-bed (Tenax GR) needles were tested with standard gaseous mixtures prepared at different relative humidity levels (85%, 50% and 10%). The standard mixtures contained twenty-five analytes representative of breath and ambient air constituents, including hydrocarbons, ketones, aldehydes, aromatics, and sulphurs, in the concentration range 0.1-700 ppbv. The two needles showed different behaviours, as recovery was independent of humidity for single-beds, whereas a low recovery (10-20%) was observed when triple-beds trapped very volatile compounds at low humidity (e.g. pentane and ethanol, 10% relative humidity. Triple-beds showed an almost quantitative recovery (>90%) of all the analytes at 50% and 85% relative humidity. This big difference was probably due to the reduced action of water vapour pressure during the desorption step. The addition of 6D-acetone and 8D-toluene to the sorbent material before gas sampling and the normalization of raw data nullified this effect, thereby lowering the variations of analyte recovery at different humidity levels down to 20%. Internal standards were also exploited to limit within 10-20% alterations in peak areas of very volatile compounds during needle storage at room temperature. This variation may results from a loss of water vapour either retained from the sorbent material and/or condensed on triple-bed needle walls. After normalization, the inter- and intra-day precision were halved to 5% and 10% in the case of single-beds, respectively, and to 15% and 20% with three-beds. The addition of an internal standard to the sorbent helps to keep the overall analytical procedure under control and improves the reliability of needle trap micro-extraction for the analysis of volatile organic compounds at ultra-trace levels.

17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 1382-1385, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946150

RESUMEN

The aim of this work is to present the architecture of the KardiaSoft software, a clinical decision support tool allowing the healthcare professionals to monitor patients with heart failure by providing useful information and suggestions in terms of the estimation of the presence of heart failure (heart failure diagnosis), stratification-patient profiling, long term patient condition evaluation and therapy response monitoring. KardiaSoft is based on predictive modeling techniques that analyze data that correspond to four saliva biomarkers, measured by a point-of-care device, along with other patient's data. The KardiaSoft is designed based on the results of a user requirements elicitation process. A small clinical scale study with 135 subjects and an early clinical study with 90 subjects will take place in order to build and validate the predictive models, respectively.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Insuficiencia Cardíaca , Biomarcadores , Humanos , Saliva , Programas Informáticos
18.
RSC Adv ; 8(10): 5578-5585, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30820317

RESUMEN

A new series of sidewall modified single-walled carbon nanotubes (SWCNTs) with perfluorophenyl molecules bearing carboxylic acid or methyl ester moieties are herein reported. Pristine and functionalized SWCNTs (p-SWCNTs and f-SWCNTs, respectively) were characterized by X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and scanning electron microscopy (SEM). The nitrene-based functionalization provided intact SWCNTs with methyl 4-azido-2,3,5,6-tetrafluorobenzoate (SWCNT-N-C6F4CO2CH3) and 4-azido-2,3,5,6-tetrafluorobenzoic acid (SWCNT-N-C6F4CO2H) attached every 213 and 109 carbon atoms, respectively. Notably, SWCNT-N-C6F4CO2H was sensitive in terms of the percentage of conductance variation from 5 to 40 ppm of ammonia (NH3) and trimethylamine (TMA) with a two-fold higher variation of conductance compared to p-SWCNTs at 40 ppm. The sensors are highly sensitive to NH3 and TMA as they showed very low responses (0.1%) toward 200 ppm of volatile organic compounds (VOCs) containing various functional groups representative of different classes of analytes such as benzene, tetrahydrofurane (THF), hexane, ethyl acetate (AcOEt), ethanol, acetonitrile (CH3CN), acetone and chloroform (CHCl3). Our system is a promising candidate for the realization of single-use chemiresistive sensors for the detection of threshold crossing by low concentrations of gaseous NH3 and TMA at room temperature.

19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 3878-3881, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30441209

RESUMEN

The aim of this work is to present KardiaTool platform, an integrated Point of Care (POC) solution for noninvasive diagnosis and therapy monitoring of Heart Failure (HF) patients. The KardiaTool platform consists of two components, KardiaPOC and KardiaSoft. KardiaPOC is an easy to use portable device with a disposable Lab-on-Chip (LOC) for the rapid, accurate, non-invasive and simultaneous quantitative assessment of four HF related biomarkers, from saliva samples. KardiaSoft is a decision support software based on predictive modeling techniques that analyzes the POC data and other patient's data, and delivers information related to HF diagnosis and therapy monitoring. It is expected that identifying a source comparable to blood, for biomarker information extraction, such as saliva, that is cost-effective, less invasive, more convenient and acceptable for both patients and healthcare professionals would be beneficial for the healthcare community. In this work the architecture and the functionalities of the KardiaTool platform are presented.


Asunto(s)
Insuficiencia Cardíaca , Sistemas de Atención de Punto , Biomarcadores , Humanos , Dispositivos Laboratorio en un Chip , Saliva
20.
Anal Chim Acta ; 989: 80-87, 2017 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-28915945

RESUMEN

The present work describes a non invasive lactate sensing in sweat during workout. The sensing system is based on a non-equilibrium potentiometric measure performed using disposable, chemically modified, screen printed carbon electrodes (SPCEs) that can be wetted with sweat during the exercise. The potentiometric signal, which is proportional to lactate concentration in sweat, is produced by a redox reaction activated by UV radiation, as opposed to the enzymatic reaction employed in traditional, blood-based measuring devices. The sensing system exhibits chemical selectivity toward lactate with linearity from 1 mM up to 180 mM. The dynamic linear range is suitable for measurement of lactate in sweat, which is more than 10 times concentrated than hematic lactate and reaches more than 100 mM in sweat during workout. The noninvasive measure can be repeated many times during exercise and during the recovery time in order to get personal information on the physiological and training status as well as on the physical performance. The device was successfully applied to several human subjects for the measurement of sweat lactate during prolonged cycling exercise. During the exercise sweat was simultaneously sampled on filter paper and extracted in water, and the lactate was determined by HPLC for method validation. The lactate concentration changes during the exercise reflected the intensity of physical effort. This method has perspectives in many sport disciplines as well as in health care and biomedical area.


Asunto(s)
Ácido Láctico/análisis , Potenciometría , Sudor/química , Electrodos , Ejercicio Físico , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA