Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 117(26): 14682-14687, 2020 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-32546523

RESUMEN

We predict and experimentally verify an entoptic phenomenon through which humans are able to perceive and discriminate optical spin-orbit states. Direct perception and discrimination of these particular states of light with polarization-coupled spatial modes is possible through the observation of distinct profiles induced by the interaction between polarization topologies and the radially symmetric dichroic elements that are centered on the foveola in the macula of the human eye. A psychophysical study was conducted where optical states with a superposition of right and left circular polarization coupled to two different orbital angular momentum (OAM) values ([Formula: see text] and [Formula: see text]) were directed onto the retina of participants. The number of azimuthal fringes that a human sees when viewing the spin-orbit states is shown to be equal to the number (N) of radial lines in the corresponding polarization profile of the beam, where [Formula: see text] The participants were able to correctly discriminate between two states carrying OAM [Formula: see text] and differentiated by [Formula: see text] and [Formula: see text], with an average success probability of 77.6% (average sensitivity [Formula: see text], [Formula: see text], [Formula: see text]). These results enable methods of robustly characterizing the structure of the macula, probing retina signaling pathways, and conducting experiments with human detectors and optical states with nonseparable modes.


Asunto(s)
Fenómenos Fisiológicos Oculares , Retina/fisiología , Percepción Visual/fisiología , Humanos , Luz , Estimulación Luminosa , Teoría Cuántica
2.
Proc Natl Acad Sci U S A ; 116(41): 20328-20332, 2019 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-31548384

RESUMEN

Spin-orbit coupling of light has come to the fore in nanooptics and plasmonics, and is a key ingredient of topological photonics and chiral quantum optics. We demonstrate a basic tool for incorporating analogous effects into neutron optics: the generation and detection of neutron beams with coupled spin and orbital angular momentum. The 3He neutron spin filters are used in conjunction with specifically oriented triangular coils to prepare neutron beams with lattices of spin-orbit correlations, as demonstrated by their spin-dependent intensity profiles. These correlations can be tailored to particular applications, such as neutron studies of topological materials.

3.
Opt Express ; 24(20): 22528-22535, 2016 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-27828323

RESUMEN

We use a Mach-Zehnder interferometer to perform neutron holography of a spiral phase plate. The object beam passes through a spiral phase plate, acquiring the phase twist characteristic of orbital angular momentum states. The reference beam passes through a fused silica prism, acquiring a linear phase gradient. The resulting hologram is a fork dislocation image, which could be used to reconstruct neutron beams with various orbital angular momenta. This work paves the way for novel applications of neutron holography, diffraction and imaging.

4.
Front Neurosci ; 17: 1232532, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37559704

RESUMEN

The dichroic macular pigment in the Henle fiber layer in the fovea enables humans to perceive entoptic phenomena when viewing polarized blue light. In the standard case of linearly polarized stimuli, a faint bowtie-like pattern known as the Haidinger's brush appears in the central point of fixation. As the shape and clarity of the perceived signal is directly related to the health of the macula, Haidinger's brush has been used as a diagnostic marker in studies of early stage macular degeneration and central field visual dysfunction. However, due to the weak nature of the perceived signal the perception of the Haidinger's brush has not been integrated with modern clinical methods. Recent attempts have been made to increase the strength of the perceived signal by employing structured light with spatially varying polarization profiles. Here we review the advancements with the structured light stimuli and describe the current challenges and future prospects.

5.
Sci Adv ; 8(46): eadd2002, 2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36399573

RESUMEN

Methods of preparation and analysis of structured waves of light, electrons, and atoms have been advancing rapidly. Despite the proven power of neutrons for material characterization and studies of fundamental physics, neutron science has not been able to fully integrate these techniques because of small transverse coherence lengths, the relatively poor resolution of spatial detectors, and low fluence rates. Here, we demonstrate methods that are practical with the existing technologies and show the experimental achievement of neutron helical wavefronts that carry well-defined orbital angular momentum values. We discuss possible applications and extensions to spin-orbit correlations and material characterization techniques.

6.
Materials (Basel) ; 14(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34443211

RESUMEN

Topologically nontrivial spin textures host great promise for future spintronic applications. Skyrmions in particular are of burgeoning interest owing to their nanometric size, topological protection, and high mobility via ultra-low current densities. It has been previously reported through magnetic susceptibility, microscopy, and scattering techniques that Co8Zn8Mn4 forms an above room temperature triangular skyrmion lattice. Here, we report the synthesis procedure and characterization of a polycrystalline Co8Zn8Mn4 disordered bulk sample. We employ powder X-ray diffraction and backscatter Laue diffraction as characterization tools of the crystallinity of the samples, while magnetic susceptibility and Small Angle Neutron Scattering (SANS) measurements are performed to study the skyrmion phase. Magnetic susceptibility measurements show a dip anomaly in the magnetization curves, which persists over a range of approximately 305 K-315 K. SANS measurements reveal a rotationally disordered polydomain skyrmion lattice. Applying a symmetry-breaking magnetic field sequence, we were able to orient and order the previously jammed state to yield the prototypical hexagonal diffraction patterns with secondary diffraction rings. This emergence of the skyrmion order serves as a unique demonstration of the fundamental interplay of structural disorder and anisotropy in stabilizing the thermal equilibrium phase.

7.
Int J Nanomedicine ; 7: 5019-28, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23055720

RESUMEN

Sample preparation is a significant challenge for detection and sensing technologies, since the presence of blood cells can interfere with the accuracy and reliability of virus detection at the nanoscale for point-of-care testing. To the best of our knowledge, there is not an existing on-chip virus isolation technology that does not use complex fluidic pumps. Here, we presented a lab-on-a-chip filter device to isolate plasma and viruses from unprocessed whole blood based on size exclusion without using a micropump. We demonstrated that viruses (eg, HIV) can be separated on a filter-based chip (2-µm pore size) from HIV-spiked whole blood at high recovery efficiencies of 89.9% ± 5.0%, 80.5% ± 4.3%, and 78.2% ± 3.8%, for viral loads of 1000, 10,000 and 100,000 copies/mL, respectively. Meanwhile, 81.7% ± 6.7% of red blood cells and 89.5% ± 2.4% of white blood cells were retained on 2 µm pore-sized filter microchips. We also tested these filter microchips with seven HIV-infected patient samples and observed recovery efficiencies ranging from 73.1% ± 8.3% to 82.5% ± 4.1%. These results are first steps towards developing disposable point-of-care diagnostics and monitoring devices for resource-constrained settings, as well as hospital and primary care settings.


Asunto(s)
Eliminación de Componentes Sanguíneos/instrumentación , VIH/aislamiento & purificación , Análisis por Micromatrices/instrumentación , Nanotecnología/instrumentación , Plasma/virología , Ultrafiltración/instrumentación , Virus/aislamiento & purificación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA