Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Colorectal Dis ; 20(12): 1088-1096, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29999580

RESUMEN

AIM: The concept of significant polyps and early colorectal cancer (SPECC) encompasses complex polyps not amenable to routine snare polypectomy or where malignancy cannot be excluded. Surgical resection (SR) offers definitive treatment, but is overtreatment for the majority which are benign and amenable to less invasive endoscopic resection (ER). The aim of this study was to investigate variations in the management and outcomes of significant colorectal polyps. METHOD: This was a retrospective observational study of significant colorectal polyps, defined as nonpedunculated lesions of ≥ 20 mm size, diagnosed across nine UK hospitals in 2014. Inclusion criteria were endoscopically or histologically benign polyps at biopsy. RESULTS: A total of 383 patients were treated by primary ER (87.2%) or SR (12.8%). Overall, 108/383 (28%) polyps were detected in the Bowel Cancer Screening Programme (BCSP). Primary SR was associated with a significantly longer length of stay and major complications (P < 0.01). Of the ER polyps, 290/334 (86.8%) patients were treated without undergoing surgery. The commonest indication for secondary surgery was unexpected polyp cancer, and of these cases 60% had no residual cancer in the specimen. Incidence of unexpected cancer was 10.7% (n = 41) and was similar between ER and SR groups (P = 0.11). On multivariate analysis, a polyp size of > 30 mm and non-BCSP status were independent risk factors for primary SR [OR 2.51 (95% CI 1.08-5.82), P = 0.03]. CONCLUSION: ER is safe and feasible for treating significant colorectal polyps. Robust accreditation within the BCSP has led to improvements in management, with lower rates of SR compared with non-BCSP patients. Standardization, training in polyp assessment and treatment within a multidisciplinary team may help to select appropriate treatment strategies and improve outcomes.


Asunto(s)
Pólipos del Colon/cirugía , Colonoscopía/métodos , Neoplasias Colorrectales/prevención & control , Detección Precoz del Cáncer/métodos , Anciano , Pólipos del Colon/complicaciones , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/etiología , Estudios de Factibilidad , Femenino , Humanos , Tiempo de Internación , Masculino , Uso Excesivo de los Servicios de Salud/prevención & control , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Reino Unido
2.
Colorectal Dis ; 19(1): 67-75, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27610599

RESUMEN

AIM: The management of large non-pedunculated colorectal polyps (LNPCPs) is complex, with widespread variation in management and outcome, even amongst experienced clinicians. Variations in the assessment and decision-making processes are likely to be a major factor in this variability. The creation of a standardized minimum dataset to aid decision-making may therefore result in improved clinical management. METHOD: An official working group of 13 multidisciplinary specialists was appointed by the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and the British Society of Gastroenterology (BSG) to develop a minimum dataset on LNPCPs. The literature review used to structure the ACPGBI/BSG guidelines for the management of LNPCPs was used by a steering subcommittee to identify various parameters pertaining to the decision-making processes in the assessment and management of LNPCPs. A modified Delphi consensus process was then used for voting on proposed parameters over multiple voting rounds with at least 80% agreement defined as consensus. The minimum dataset was used in a pilot process to ensure rigidity and usability. RESULTS: A 23-parameter minimum dataset with parameters relating to patient and lesion factors, including six parameters relating to image retrieval, was formulated over four rounds of voting with two pilot processes to test rigidity and usability. CONCLUSION: This paper describes the development of the first reported evidence-based and expert consensus minimum dataset for the management of LNPCPs. It is anticipated that this dataset will allow comprehensive and standardized lesion assessment to improve decision-making in the assessment and management of LNPCPs.


Asunto(s)
Toma de Decisiones Clínicas/métodos , Pólipos del Colon , Cirugía Colorrectal/normas , Consenso , Gastroenterología/normas , Humanos , Irlanda , Sociedades Médicas , Reino Unido
4.
Colorectal Dis ; 14(11): e771-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22958651

RESUMEN

AIM: The study aimed to investigate whether narrow-band imaging (NBI) can enhance adenoma detection in patients at high risk for adenomas compared with high-definition white-light endoscopy (WLE). High risk was defined as three or more adenomas at last colonoscopy, history of colorectal cancer and positive faecal occult blood test. METHOD: Two hundred and fourteen patients were randomized 1:1 to examination with NBI or WLE. The primary outcome measure was the proportion of patients with at least one adenoma detected. Secondary outcomes included total adenomas and polyps, flat adenomas, nonadenomatous polyps, advanced adenomas and patients with three or five or more adenomas. A post hoc analysis to examine the effect of endoscopist and bowel preparation was performed. RESULTS: There was no significant difference in the proportion of patients with at least one adenoma: NBI 73%vs WLE 66%, odds ratio 1.40 (95% CI 0.78-2.52), P = 0.26. There was no significant difference for any secondary outcome measure except for the number of flat adenomas which was significantly greater with NBI [comparison ratio 2.66 (95% CI 1.52-4.63), P = 0.001]. Post hoc analysis indicated that one of three endoscopists performed significantly better for adenoma detection with NBI than WLE [comparison ratio 1.92 (95% CI 1.07-3.44), P = 0.03]. Good bowel preparation was associated with significantly improved adenoma detection with NBI [comparison ratio 1.55 (95% CI 1.01-2.22), P = 0.04] but not with fair preparation. CONCLUSION: Overall NBI did not improve detection compared with WLE in a group of patients at high risk for colorectal adenomas, but specific subgroups might benefit.


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopía/instrumentación , Imagen de Banda Estrecha/métodos , Anciano , Colonoscopía/métodos , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante
5.
Colorectal Dis ; 14(2): 166-73, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21689280

RESUMEN

AIM: St Mark's Bowel Cancer Screening Centre commenced screening in October 2006 as a contributor to the national programme. The first 35 months' experience is reported. METHOD: Individuals with a positive faecal occult blood test (FOBT) were offered colonoscopy or alternatives if they had significant comorbidity. All screening data were collected prospectively. RESULTS: Of the 98 815 FOBT kits issued, 42 523 were returned (43% uptake; 20.79% men). In total, 1339/1488 (90%) FOBT-positive participants attended the nurse clinic (57% men). Of these, 1057 had an index colonoscopy, 115 had a computed tomography colonoscopy (CTC) and eight had a flexible sigmoidoscopy. Five hundred and seventeen (44%) procedures were 'normal' (no polyps/cancers). Eighty (6%) individuals had colorectal cancer. The polyp detection rate in index procedures, including colonoscopy, CTC and flexible sigmoidoscopy, was 50%. The adenoma detection rate of all colonoscopies was 62.8%. The median polyp size was 5 (1-80) mm. In total, 1200 colonoscopies were performed by five accredited colonoscopists (96% completion rate). There were 13 (1%) adverse events with < 1 in 500 patients undergoing polypectomy requiring a transfusion. There was one 30-day postsurgical mortality, one perforation and no colonoscopy-related mortality. Almost all 39/40 (97%) patients in the BCS programme felt that the findings were adequately explained compared with 21/32 (64%) elective patients (P < 0.001) within the same unit. CONCLUSIONS: At this bowel cancer screening single centre, colonoscopy completion rates were high (unadjusted caecal intubation rate of 96%) and complication rates were low. In contrast to other published data, the uptake and cancer-detection rates were lower.


Asunto(s)
Adenoma/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopía/estadística & datos numéricos , Neoplasias Colorrectales/diagnóstico , Tamizaje Masivo/estadística & datos numéricos , Sangre Oculta , Adenoma/patología , Anciano , Competencia Clínica , Pólipos del Colon/patología , Pólipos del Colon/cirugía , Colonoscopía/efectos adversos , Neoplasias Colorrectales/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Programas Nacionales de Salud/estadística & datos numéricos , Satisfacción del Paciente , Sigmoidoscopía/estadística & datos numéricos , Tomografía Computarizada por Rayos X , Reino Unido
6.
Colorectal Dis ; 14(12): 1538-45, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22540766

RESUMEN

AIM: Completeness and thoroughness of colonoscopy are measured by the caecal intubation rate (CIR) and the adenoma detection rate (ADR). National standards are ≥ 90% and ≥ 10% respectively. Variability in CIR and ADR have been demonstrated but comparison between individuals and units is difficult. We aimed to assess the performance of colonoscopy in endoscopy units in the northeast of England. METHOD: Data on colonoscopy performance and sedation use were collected over 3 months from 12 units. Colonoscopies performed by screening colonoscopists were included for the CIR only. Funnel plots with upper and lower 95% confidence limits for CIR and ADR were created. RESULTS: CIR was 92.5% (n = 5720) and ADR 15.9% (n = 4748). All units and 128 (99.2%) colonoscopists were above the lower limit for CIR. All units achieved the ADR standard with 10 above the upper limit. Ninety-nine (76.7%) colonoscopists were above 10%, 16 (12.4%) above the upper limit and 7 (5.4%) below the lower limit. Median medication doses were 2.2 mg midazolam, 29.4 mg pethidine and 83.3 µg fentanyl. In all, 15.1% of colonoscopies were unsedated. Complications were bleeding (0.10%) and perforation (0.02%). There was one death possibly related to bowel preparation. CONCLUSION: Results indicate that colonoscopies are performed safely and to a high standard. Funnel plots can highlight variability and areas for improvement. Analyses of ADR presented graphically around the global mean suggest that the national standard should be reset at 15%.


Asunto(s)
Adenoma/diagnóstico , Cateterismo/normas , Neoplasias del Colon/diagnóstico , Colonoscopía/normas , Sedación Profunda/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/métodos , Ciego , Competencia Clínica , Colonoscopía/efectos adversos , Colonoscopía/estadística & datos numéricos , Inglaterra , Fentanilo , Humanos , Hipnóticos y Sedantes/administración & dosificación , Meperidina , Midazolam , Narcóticos/administración & dosificación , Guías de Práctica Clínica como Asunto , Mejoramiento de la Calidad
7.
Endoscopy ; 43(2): 94-9, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21271465

RESUMEN

BACKGROUND AND STUDY AIMS: In vivo optical diagnosis of small colorectal polyps has potential clinical and cost advantages, but requires accuracy and high interobserver agreement for clinically acceptability. We aimed to assess interobserver variability and diagnostic performance of endoscopic imaging modalities in characterizing small colonic polyps. METHODS: High quality still images of 80 polyps < 1 cm were recorded using white-light endoscopy (WLE), autofluorescence imaging (AFI) and narrow-band imaging with and without magnification (NBI and NBImag). All images were assessed for quality, prediction of polyp histology, and vascular pattern intensity (with NBI) by nine experienced colonoscopists (four experts in advanced imaging) from five UK centers. Interobserver agreement (kappa statistic), sensitivity, specificity, and accuracy were calculated compared with histopathological findings. RESULTS: Interobserver agreement for predicting polyp histology using NBImag was significantly better for experts (κ = 0.63, substantial) compared with nonexperts (κ = 0.30, fair; P < 0.001), and was moderate for all colonoscopists with WLE, AFI and NBI. Interobserver agreement for vascular pattern intensity using NBI was 0.69 (substantial) for experts and 0.57 (good) for nonexperts. NBImag had higher sensitivity than WLE (experts, 0.93 vs. 0.68, P < 0.001; nonexperts, 0.90 vs. 0.52, P < 0.001) and higher overall accuracy (experts, 0.76 vs. 0.64, P = 0.003; nonexperts 0.61 vs. 0.40, P < 0.001). AFI had worse accuracy than WLE for both expert colonoscopists (0.53 vs. 0.64, P = 0.02) and nonexperts (0.32 vs. 0.40, P = 0.04). CONCLUSIONS: Of the imaging modalities tested, NBImag appeared to have the best overall accuracy and interobserver agreement, although not adequate for in vivo diagnosis. NBI and AFI did not have better sensitivity, specificity, or accuracy compared with WLE.


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopía/métodos , Diagnóstico por Imagen/métodos , Fluorescencia , Luz , Adenoma/patología , Anciano , Neoplasias del Colon/patología , Pólipos del Colon/patología , Femenino , Humanos , Aumento de la Imagen/métodos , Mucosa Intestinal/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Sensibilidad y Especificidad
8.
Clin Radiol ; 65(12): 958-66, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21070898

RESUMEN

With the recent publication of international computed tomography (CT) colonography standards, which aim to improve quality of examinations, this review informs radiologists about the significance of flat polyps (adenomas and hyperplastic polyps) in colorectal cancer pathways. We describe flat polyp classification systems and propose how flat polyps should be reported to ensure patient management strategies are based on polyp morphology as well as size. Indeed, consistency when describing flat polyps is of increasing importance given the strengthening links between CT colonography and endoscopy.


Asunto(s)
Pólipos Adenomatosos/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/normas , Neoplasias Colorrectales/diagnóstico por imagen , Radiología/normas , Pólipos Adenomatosos/clasificación , Pólipos Adenomatosos/patología , Pólipos del Colon/clasificación , Pólipos del Colon/patología , Colonoscopía , Neoplasias Colorrectales/clasificación , Neoplasias Colorrectales/patología , Humanos , Guías de Práctica Clínica como Asunto/normas
10.
Gut ; 57(1): 65-70, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17682000

RESUMEN

BACKGROUND: Colonoscopic surveillance for hereditary non-polyposis colorectal cancer (HNPCC) reduces death rates, but early interval cancers still occur, probably due to missed small, aggressive adenomas. Narrow band imaging (NBI), a novel endoscopic technology, highlights superficial mucosal capillaries and improves contrast for adenomas. This study examined whether a second pass with NBI in the proximal colon helped detect additional adenomas in patients with HNPCC. METHODS: 62 patients from HNPCC families (Amsterdam II or genetic criteria) attending for colonoscopic surveillance were examined twice from caecum to sigmoid-descending junction, first with high definition white light and then a second pass with NBI in a back-to-back fashion. All polyps detected were removed for histopathological analysis. RESULTS: At least one adenoma in the proximal colon was detected during the initial white light pass in 17/62 (27%). NBI detected additional adenomas in 17/62 (27%). 26/62 (42%) patients had at least one adenoma detected after both white light and NBI; absolute difference 15% (95% CI 4-25%), p = 0.004 versus white light alone. The total number of adenomas increased from 25 before NBI to 46 after NBI examination, p<0.001. The proportion of flat adenomas detected in the NBI pass, 9/21 (45%), was higher than in the white light pass, 3/25 (12%), p = 0.03. Including white light examination of the sigmoid and rectum, overall 28/62 (45%) patients had at least one adenoma detected. CONCLUSIONS: Use of NBI in the proximal colon for patients undergoing HNPCC surveillance appears to improve adenoma detection, particularly those with a flat morphology. NBI could help reduce interval cancer rates.


Asunto(s)
Adenoma/diagnóstico , Colonoscopía/métodos , Neoplasias Colorrectales Hereditarias sin Poliposis/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias del Colon/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Retratamiento , Sensibilidad y Especificidad
11.
Aliment Pharmacol Ther ; 28(6): 768-76, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18715401

RESUMEN

BACKGROUND: Colonoscopy has a known miss rate for polyps and adenomas. High definition (HD) colonoscopes may allow detection of subtle mucosal change, potentially aiding detection of adenomas and hyperplastic polyps. AIM: To compare detection rates between HD and standard definition (SD) colonoscopy. METHODS: Prospective, cohort study with optimized withdrawal technique (withdrawal time >6 min, antispasmodic, position changes, re-examining flexures and folds). One hundred and thirty patients attending for routine colonoscopy were examined with either SD (n = 72) or HD (n = 58) colonoscopes. RESULTS: Groups were well matched. Sixty per cent of patients had at least one adenoma detected with SD vs. 71% with HD, P = 0.20, relative risk (benefit) 1.32 (95% CI 0.85-2.04). Eighty-eight adenomas (mean +/- standard deviation 1.2 +/- 1.4) were detected using SD vs. 93 (1.6 +/- 1.5) with HD, P = 0.12; however more nonflat, diminutive (<6 mm) adenomas were detected with HD, P = 0.03. Twenty-three proximal hyperplastic polyps (0.32 +/- 0.58) were detected with SD vs. 31 (0.53 +/- 0.86) with HD, P = 0.35. Overall prevalence of proximal large (>9 mm) hyperplastic polyps was 7% (0.09 +/- 0.36). CONCLUSIONS: High definition did not lead to a significant increase in adenoma or hyperplastic polyp detection, but may help where comprehensive lesion detection is paramount. High detection rates appear possible with either SD or HD, when using an optimized withdrawal technique.


Asunto(s)
Adenoma/diagnóstico , Pólipos del Colon/diagnóstico , Colonoscopios , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Adenoma/epidemiología , Adenoma/patología , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Pólipos del Colon/epidemiología , Pólipos del Colon/patología , Colonoscopía/normas , Neoplasias Colorrectales/epidemiología , Neoplasias Colorrectales/patología , Femenino , Humanos , Hiperplasia , Masculino , Persona de Mediana Edad
12.
Endoscopy ; 40(5): 437-42, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18398783

RESUMEN

Persistence of underlying disease in the residual rectal mucosa and anal transition zone occurs following mucosectomy with either a hand-sewn anastomosis or a double-stapled anastomosis. Furthermore, recent reports have suggested an increased incidence of neoplasia in the pouch body. For this reason, endoscopic surveillance is performed not only as a screening tool to detect significant intraepithelial neoplastic lesions but also with secondary therapeutic intent aimed at reducing the adenoma burden within the ileoanal pouch. Conventional endoscopic assessment of the ileoanal pouch can be challenging. In the future, novel adjunctive endoscopic technologies such as magnification endoscopy and confocal endomicroscopy may improve our diagnostic and therapeutic management of this group.


Asunto(s)
Poliposis Adenomatosa del Colon/patología , Poliposis Adenomatosa del Colon/cirugía , Reservorios Cólicos , Endoscopía Gastrointestinal , Vigilancia de la Población , Proctocolectomía Restauradora , Humanos
14.
Endoscopy ; 40(10): 811-7, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18828077

RESUMEN

BACKGROUND AND STUDY AIMS: Narrow band imaging (NBI) can accurately characterize colonic polyps using microvascular appearances. We aimed to assess whether the Kudo pit pattern classification is accurate when used with NBI (without dye-spray), and if microvascular appearances or NBI pit patterns maintain accuracy for polyp characterization at sizes < 10 mm. PATIENTS AND METHODS: 116 polyps < 10 mm in size were detected in 62 patients undergoing surveillance colonoscopy. The polyps were prospectively assessed using NBI and magnification for Kudo pit pattern (III-V neoplastic, I-II non-neoplastic) and vascular pattern intensity (VPI), a measure of microvascular density (strong VPI, neoplastic; normal or weak VPI, non-neoplastic). Sensitivity, specificity, and accuracy were calculated and compared with results from histopathology. RESULTS: The mean polyp size was 3.4 mm (range 1 - 9 mm). Overall, NBI pit pattern sensitivity, specificity, and accuracy were 0.88, 0.91, and 89.6 %, respectively. Equivalent values for VPI were 0.94, 0.89, and 91.4 %. Results were similar when polyps were subdivided into diminutive polyps (size

Asunto(s)
Neoplasias del Colon/patología , Pólipos del Colon/patología , Colonoscopía , Aumento de la Imagen , Lesiones Precancerosas/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
15.
Endoscopy ; 39(9): 818-24, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17703392

RESUMEN

BACKGROUND AND AIMS: Poor standards in colonoscopy services and the introduction of a colorectal cancer screening program in the United Kingdom have highlighted the need to establish high-quality training and competency assessments in colonoscopy. The aims of this study were to evaluate the effectiveness of a 1-week hands-on colonoscopy course utilizing novel assessment tools. METHODS: Twenty-one doctors with varying colonoscopy experience who attended an accelerated colonoscopy training week (ACTW) were prospectively studied. They were trained and assessed in key aspects of colonoscopy. Knowledge was assessed with a multiple choice question (MCQ) paper. Practical hand skills were taught and evaluated using a computer simulator and live case teaching. Actual colonoscopy performance was assessed using Direct Observation of Procedural Skills scores (DOPS) and an objective tri-split video score of insertion technique. Two independent trainers taught and assessed the trainees at the start and end of the ACTW and at a median of 9 months' follow-up. RESULTS: Following training there were significant improvements in the MCQ score (P < 0.001), the simulator test case times (P = 0.02, P = 0.003), and the global DOPS score (P < or = 0.02). All improvements following the accelerated training were sustained at a median follow-up of 9 months. CONCLUSIONS: This study is the first in the literature to describe the positive, sustained impact of an intensive hands-on colonoscopy training course. Measurements of performance in key areas of skill acquisition improved following training.


Asunto(s)
Competencia Clínica , Colonoscopía , Curriculum , Instrucción por Computador , Educación Médica Continua , Evaluación Educacional , Humanos , Estudios Prospectivos , Calidad de la Atención de Salud , Factores de Tiempo , Reino Unido , Grabación en Video
16.
Gut ; 55(10): 1432-5, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16966701

RESUMEN

A 62 year old man with longstanding ulcerative colitis and previous endoscopic excision of two dysplasia associated lesions or masses (DALMs) was admitted to our endoscopy unit for evaluation and resection of other possible DALMs. He had previously been offered and refused colectomy because of comorbidity from Parkinson's disease. He had multiple polypoid and sessile lesions which were assessed using a third generation prototype narrow band imaging (NBI) colonoscope with magnification. Selected lesions were either biopsied or resected with a combination of endoscopic submucosal dissection and endoscopic mucosal resection techniques. We correlated the pit pattern and vascular pattern intensity seen with magnification NBI with histology of both inflammatory and dysplastic lesions. Dysplastic areas showed Kudo pit patterns II, IIIL, and IV and high vascular pattern intensity. Non-dysplastic and dysplastic areas of recurrence immediately adjacent to the scar from a previous endoscopic mucosal resection site were also assessed. This is the first case report where NBI has been shown to help in DALM detection and to distinguish dysplastic from non-dysplastic mucosa in ulcerative colitis.


Asunto(s)
Colitis Ulcerosa/patología , Colonoscopía/métodos , Colon Sigmoide/patología , Neoplasias del Colon/patología , Pólipos del Colon/patología , Humanos , Masculino , Persona de Mediana Edad , Lesiones Precancerosas/patología , Magnificación Radiográfica
20.
Gastrointest Endosc Clin N Am ; 7(3): 469-75, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9177147

RESUMEN

Because of the variability of the colonic anatomy from patient to patient, colonoscopy may be technically difficult to perform and teach, and lesions may be localized inaccurately by the endoscopist. Endoscopists understandably have abandoned fluoroscopy as an adjunct because of its expense, complexity, and potential hazard. The authors have developed a novel method of magnetic imaging that gives real-time views in simulated three dimensions of the endoscope configuration and the location of its tip in the abdomen. The system is inherently safe and easy to use, although it currently requires a catheter to be inserted into the instrumentation channel. Preliminary experience suggests that this approach will be a significant help to endoscopists performing colonoscopy, particularly to those who are currently learning or less experienced.


Asunto(s)
Enfermedades del Colon/diagnóstico , Colonoscopios , Diagnóstico por Imagen/instrumentación , Competencia Clínica , Sistemas de Computación , Campos Electromagnéticos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA