Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(14)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39065912

RESUMEN

OBJECTIVE: The aim of this analysis was to assess glycemic control before and during the coronavirus disease (COVID-19) pandemic. METHODS: Data from 64 (main analysis) and 80 (sensitivity analysis) people with type 1 diabetes (T1D) using intermittently scanned continuous glucose monitoring (isCGM) were investigated retrospectively. The baseline characteristics were collected from electronic medical records. The data were examined over three periods of three months each: from 16th of March 2019 until 16th of June 2019 (pre-pandemic), from 1st of December 2019 until 29th of February 2020 (pre-lockdown) and from 16th of March 2020 until 16th of June 2020 (lockdown 2020), representing the very beginning of the COVID-19 pandemic and the first Austrian-wide lockdown. RESULTS: For the main analysis, 64 individuals with T1D (22 female, 42 male), who had a mean glycated hemoglobin (HbA1c) of 58.5 mmol/mol (51.0 to 69.3 mmol/mol) and a mean diabetes duration 13.5 years (5.5 to 22.0 years) were included in the analysis. The time in range (TIR[70-180mg/dL]) was the highest percentage of measures within all three studied phases, but the lockdown 2020 phase delivered the best data in all these cases. Concerning the time below range (TBR[<70mg/dL]) and the time above range (TAR[>180mg/dL]), the lockdown 2020 phase also had the best values. Regarding the sensitivity analysis, 80 individuals with T1D (26 female, 54 male), who had a mean HbA1c of 57.5 mmol/mol (51.0 to 69.3 mmol/mol) and a mean diabetes duration of 12.5 years (5.5 to 20.7 years), were included. The TIR[70-180mg/dL] was also the highest percentage of measures within all three studied phases, with the lockdown 2020 phase also delivering the best data in all these cases. The TBR[<70mg/dL] and the TAR[>180mg/dL] underscored the data in the main analysis. CONCLUSION: Superior glycemic control, based on all parameters analyzed, was achieved during the first Austrian-wide lockdown compared to prior periods, which might be a result of reduced daily exertion or more time spent focusing on glycemic management.


Asunto(s)
COVID-19 , Monitoreo Continuo de Glucosa , Diabetes Mellitus Tipo 1 , Control Glucémico , Monitoreo Continuo de Glucosa/métodos , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/epidemiología , COVID-19/epidemiología , Austria/epidemiología , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Estudios Retrospectivos
2.
J Diabetes Sci Technol ; : 19322968241230106, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38366626

RESUMEN

BACKGROUND: Automated insulin delivery (AID) systems have shown to improve glycemic control in a range of populations and settings. At the start of this study, only one commercial AID system had entered the Austrian market (MiniMed 670G, Medtronic). However, there is an ever-growing community of people living with type 1 diabetes (PWT1D) using open-source (OS) AID systems. MATERIALS AND METHODS: A total of 144 PWT1D who used either the MiniMed 670G (670G) or OS-AID systems routinely for a period of at least three to a maximum of six months, between February 18, 2020 and January 15, 2023, were retrospectively analyzed (116 670G aged from 2.6 to 71.8 years and 28 OS-AID aged from 3.4 to 53.5 years). The goal is to evaluate and compare the quality of glycemic control of commercially available AID and OS-AID systems and to present all data by an in-depth descriptive analysis of the population. No statistical tests were performed. RESULTS: The PWT1D using OS-AID systems spent more time in range (TIR)70-180 mg/dL (81.7% vs 73.9%), less time above range (TAR)181-250 mg/dL (11.1% vs 19.6%), less TAR>250 mg/dL (2.5% vs 4.3%), and more time below range (TBR)54-69 mg/dL (2.2% vs 1.7%) than PWT1D using the 670G system. The TBR<54 mg/dL was comparable in both groups (0.3% vs 0.4%). In the OS-AID group, median glucose level and glycated hemoglobin (HbA1c) were lower than in the 670G system group (130 vs 150 mg/dL; 6.2% vs 7.0%). CONCLUSION: In conclusion, both groups were able to achieve satisfactory glycemic outcomes independent of age, gender, and diabetes duration. However, the PWT1D using OS-AID systems attained an even better glycemic control with no clinical safety concerns.

3.
Wien Klin Wochenschr ; 136(Suppl 9): 467-477, 2024 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-39196351

RESUMEN

People living with diabetes mellitus can be supported in the daily management by diabetes technology with automated insulin delivery (AID) systems to reduce the risk of hypoglycemia and improve glycemic control as well as the quality of life. Due to barriers in the availability of AID-systems, the use and development of open-source AID-systems have internationally increased. This technology provides a necessary alternative to commercially available products, especially when approved systems are inaccessible or insufficiently adapted to the specific needs of the users. Open-source technology is characterized by worldwide free availability of codes on the internet, is not officially approved and therefore the use is on the individual's own responsibility. In the clinical practice a lack of expertise with open-source AID technology and concerns about legal consequences, lead to conflict situations for health-care professionals (HCP), sometimes resulting in the refusal of care of people living with diabetes mellitus. This position paper provides an overview of the available evidence and practical guidance for HCP to minimize uncertainties and barriers. People living with diabetes mellitus must continue to be supported in education and diabetes management, independent of the chosen diabetes technology including open-source technology. Check-ups of the metabolic control, acute and chronic complications and screening for diabetes-related diseases are necessary and should be regularly carried out, regardless of the chosen AID-system and by a multidisciplinary team with appropriate expertise.


Asunto(s)
Diabetes Mellitus , Sistemas de Infusión de Insulina , Humanos , Austria , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus/terapia , Medicina Basada en la Evidencia , Insulina/administración & dosificación , Insulina/uso terapéutico
4.
Wien Klin Wochenschr ; 135(Suppl 1): 53-61, 2023 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-37101025

RESUMEN

This Guideline represents the recommendations of the Austrian Diabetes Association (ÖDG) on the use of diabetes technology (insulin pump therapy; continuous glucose monitoring, CGM; hybrid closed-loop systems, HCL; diabetes apps) and access to these technological innovations for people with diabetes mellitus based on current scientific evidence.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/uso terapéutico , Glucemia , Automonitorización de la Glucosa Sanguínea , Sistemas de Infusión de Insulina , Hipoglucemiantes/uso terapéutico
5.
Swiss Med Wkly ; 151: w30025, 2021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34596371

RESUMEN

The menstrual cycle increases insulin requirements in a subset of women with type 1 diabetes as a result of reduced insulin action through sexual hormones. If exposure to sexual hormones declines during the menopause, adaptions of insulin dosing may be required. However, there are no validated recommendations available on how to adapt insulin treatment in postmenopausal women with type 1 diabetes. The present study compared insulin dosing profiles of 630 premenopausal and 548 postmenopausal women, who had long-term type 1 diabetes and used continuous subcutaneous insulin infusion. Data were extracted from the German "Diabetes-Patienten- Verlaufsdokumentation". It was found that total daily insulin (p <0.0001), daily insulin per kilogram bodyweight (p <0.0001), total daily basal insulin (p <0.0001), daily basal insulin per kilogram bodyweight (p <0.0001) and estimated glomerular filtration rate (eGFR) (p <0.0001) were lower in postmenopausal women. Total daily bolus insulin, daily bolus insulin per kilogram, glycated haemoglobin A1, body mass index and the incidence of severe hypoglycaemic events were similar in both cohorts.Postmenopausal women with type 1 diabetes used lower insulin doses as compared with premenopausal women, whereas glycaemic control and body mass index were comparable. This observation might be explained by lower exposure to sexual hormones and lower eGFR, even though the contribution of other factors such as body composition and eating habits requires further investigation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Insulina , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Menopausia
6.
Diabetes Technol Ther ; 21(5): 254-264, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31021180

RESUMEN

Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless, the acceptance of rtCGM remains below expectations and the dropout rate within the first year has been reported to be 27%. Besides financial reasons due to limited reimbursement, reasons include the need for frequent sensor replacement, the discomfort of wearing a sensor, the presence of adverse skin reactions, or privacy. Thus, novel approaches to rtCGM are desired to overcome these barriers. The first long-term implantable rtCGM system diversifies the field of glucose monitoring further. However, due to its novelty, there are no published clinical practice guidelines available. Aims: The aim of this article is to set the foundation for a best clinical practice for the everyday clinical care using a long-term implantable CGM system. Methods: An international expert panel for the long-term implantable CGM system developed this best practice guidance. All participants were certified and experienced in the use of the Eversense® long-term implantable CGM system. The workflows from the respective clinics were presented, discussed and are summarized in an ideal care workflow outlined in these practice recommendations. Results: The participants agreed on the following aspects: definition of the patient population that will benefit from a long-term implantable CGM device; real-world experience on safety and accuracy of a long-term CGM; definition of the ideal sensor position; description of the optimal process for sensor insertion, removal, and replacement.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Sistemas de Infusión de Insulina , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico
7.
Wien Klin Wochenschr ; 131(Suppl 1): 47-53, 2019 May.
Artículo en Alemán | MEDLINE | ID: mdl-30980146

RESUMEN

This position statement is based on current evidence available on the safety and benefits of continuous subcutaneous insulin infusion therapy (CSII, pump therapy) in diabetes with an emphasis on the effects of CSII on glycemic control, hypoglycaemia rates, occurrence of ketoacidosis, quality of life and the use of insulin pump therapy in pregnancy. The current article represents the recommendations of the Austrian Diabetes Association for the clinical praxis of insulin pump treatment in children, adolescents and adults.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina , Calidad de Vida , Adolescente , Adulto , Austria , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Bombas de Infusión Implantables , Insulina , Masculino , Guías de Práctica Clínica como Asunto
11.
PLoS One ; 11(3): e0150604, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26938444

RESUMEN

BACKGROUND: Traditionally, basal rate profiles in continuous subcutaneous insulin infusion therapy are individually adapted to cover expected insulin requirements. However, whether this approach is indeed superior to a more constant BR profile has not been assessed so far. This study analysed the associations between variability of BR profiles and acute and chronic complications in adult type 1 diabetes mellitus. MATERIALS AND METHODS: BR profiles of 3118 female and 2427 male patients from the "Diabetes-Patienten-Verlaufsdokumentation" registry from Germany and Austria were analysed. Acute and chronic complications were recorded 6 months prior and after the most recently documented basal rate. The "variability index" was calculated as variation of basal rate intervals in percent and describes the excursions of the basal rate intervals from the median basal rate. RESULTS: The variability Index correlated positively with severe hypoglycemia (r = .06; p<0.001), hypoglycemic coma (r = .05; p = 0.002), and microalbuminuria (r = 0.05; p = 0.006). In addition, a higher variability index was associated with higher frequency of diabetic ketoacidosis (r = .04; p = 0.029) in male adult patients. Logistic regression analysis adjusted for age, gender, duration of disease and total basal insulin confirmed significant correlations of the variability index with severe hypoglycemia (ß = 0.013; p<0.001) and diabetic ketoacidosis (ß = 0.012; p = 0.017). CONCLUSIONS: Basal rate profiles with higher variability are associated with an increased frequency of acute complications in adults with type 1 diabetes.


Asunto(s)
Albuminuria/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética/sangre , Hipoglucemia/sangre , Hipoglucemiantes/efectos adversos , Coma Insulínico/sangre , Insulina/efectos adversos , Adolescente , Adulto , Albuminuria/etiología , Albuminuria/fisiopatología , Austria , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/fisiopatología , Cetoacidosis Diabética/etiología , Cetoacidosis Diabética/fisiopatología , Femenino , Alemania , Humanos , Hipoglucemia/etiología , Hipoglucemia/fisiopatología , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/sangre , Hipoglucemiantes/farmacocinética , Insulina/administración & dosificación , Insulina/sangre , Insulina/farmacocinética , Coma Insulínico/etiología , Coma Insulínico/fisiopatología , Sistemas de Infusión de Insulina , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros
12.
Diabetes Res Clin Pract ; 122: 28-37, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27764721

RESUMEN

AIMS: Compare characteristics, therapies and clinical outcomes in older adults with type 1 diabetes in the United States T1D Exchange (T1DX) and German/Austrian Diabetes Patienten Verlaufsdokumentation (DPV) registries. METHODS: Cross-sectional study of adults ≥60years old with type 1 diabetes seen in 2011-2012 in the T1DX (n=1283) and DPV (n=2014) registries. Wilcoxon rank-sum test was used for continuous variables and chi-square test for categorical variables. Adjusted analyses used generalized linear models. RESULTS: Individuals in both registries were similar in body mass index (mean 27kg/m2), percent with obesity (25%) and gender (48% male). In T1DX there was longer diabetes duration (32.3 vs. 28.8years), greater use of antihypertensive medications (including ACE-I and ARBs; 85% vs. 62%), statins (68% vs. 40%), aspirin (77% vs. 21%), insulin pumps (58% vs. 18%), and less smoking (7% vs. 10%); lower adjusted mean LDL-cholesterol (84 vs. 109mg/dL), and lower adjusted mean systolic and diastolic blood pressures (128 vs. 136 and 68 vs. 74mmHg); fewer myocardial infarctions (6% vs. 9% [99% CI of difference, 1% to 5%]), strokes (2% vs. 8% [3% to 7%]), microvascular complications including microalbuminuria (17% vs. 44% [22% to 32%]) but increased depression (16.1% vs. 8.7%). Adjusted mean HbA1c levels were similar (7.5%, 58mmol/mol). CONCLUSIONS: Differences between the registries included greater use of antihypertensives, statins and insulin pumps, and fewer chronic complications in the T1DX. Further research is needed to better understand the role of intensive therapy in improving outcomes in older adults with type 1 diabetes.


Asunto(s)
Antihipertensivos/uso terapéutico , Complicaciones de la Diabetes/epidemiología , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Sistemas de Infusión de Insulina , Sistema de Registros/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Austria , Índice de Masa Corporal , Estudios Transversales , Diabetes Mellitus Tipo 1/fisiopatología , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Estados Unidos
13.
Wien Klin Wochenschr ; 128 Suppl 2: S188-95, 2016 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-27052245

RESUMEN

This position statement is based on the current evidence available on the safety and benefits of continuous subcutaneous insulin pump therapy (CSII) in diabetes with an emphasis on the effects of CSII on glycemic control, hypoglycaemia rates, occurrence of ketoacidosis, quality of life and the use of insulin pump therapy in pregnancy. The current article represents the recommendations of the Austrian Diabetes Association for the clinical praxis of insulin pump treatment in children, adolescents and adults.


Asunto(s)
Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamiento farmacológico , Monitoreo de Drogas/normas , Sistemas de Infusión de Insulina/normas , Insulina/administración & dosificación , Guías de Práctica Clínica como Asunto , Adolescente , Adulto , Austria , Niño , Preescolar , Diabetes Mellitus/psicología , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Monitoreo de Drogas/psicología , Medicina Basada en la Evidencia , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/psicología , Masculino , Calidad de Vida/psicología , Resultado del Tratamiento , Adulto Joven
15.
J Cyst Fibros ; 13(6): 730-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24917115

RESUMEN

BACKGROUND: In Germany/Austria, data on medical care for cystic fibrosis-related diabetes (CFRD) is limited. METHODS: Anonymized data from 659 CFRD patients were analyzed and compared to the latest ADA/CFF guidelines. RESULTS: Specialized diabetes clinics were attended less frequently than recommended (3.1 vs. 4.0 times yearly). 7.9% of patients had a complete profile of examinations: diabetes education (44.9%), HbA1c (88.8%), blood pressure (79.5%), BMI (86.5%), lipid status (37.5%), retinopathy (29.9%), microalbuminuria (33.2%), and self-monitoring of blood glucose (71.6%). HbA1c and blood pressure were measured less frequently than recommended (2.3 and 2.0 vs. 4.0 times yearly). Overall, guidelines were followed more frequently in children than adults. Contrary to recommendations, not all patients were treated with insulin (77.2 vs. 100.0%). Insulin therapy was initiated earlier in children than adults, but there was still a substantial delay (0.9 vs. 2.7years after diagnosis, p<0.001). CONCLUSION: In CFRD patients studied, adherence to care guidelines was suboptimal.


Asunto(s)
Fibrosis Quística/complicaciones , Fibrosis Quística/terapia , Complicaciones de la Diabetes/terapia , Adhesión a Directriz , Adolescente , Adulto , Austria , Niño , Complicaciones de la Diabetes/etiología , Femenino , Alemania , Hemoglobina Glucada , Humanos , Hipoglucemiantes/uso terapéutico , Masculino , Evaluación Nutricional , Guías de Práctica Clínica como Asunto , Sistema de Registros , Estudios Retrospectivos , Adulto Joven
16.
Wien Klin Wochenschr ; 124 Suppl 2: 120-2, 2012 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-23250473

RESUMEN

This position statement represents the recommendations of the Austrian Diabetes Association regarding the clinical diagnostic and therapeutic application, safety and benefits of continuous subcutaneous glucose monitoring systems in patients with diabetes mellitus, based on current evidence.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/normas , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Monitoreo Ambulatorio/normas , Guías de Práctica Clínica como Asunto , Austria , Humanos
17.
Wien Klin Wochenschr ; 124 Suppl 2: 123-8, 2012 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-23371330

RESUMEN

This position statement is based on the cur-rent evidence available on the safety and benefits of continous subcutaneous insulin pump therapy (CSII) in diabetes mellitus with an emphasis on the effects of CSII on glycemic control, hypoglycaemia rates, occur-ance of ketoacidosis, quality of life and the use of insu-lin pump therapy in pregnancy. The current article rep-resents the recommendations of the Austrian Diabetes Association for the clinical praxis of insulin pump treat-ment in children and adults.


Asunto(s)
Diabetes Mellitus/tratamiento farmacológico , Diabetes Gestacional/tratamiento farmacológico , Sistemas de Infusión de Insulina/normas , Insulina/administración & dosificación , Guías de Práctica Clínica como Asunto , Adolescente , Adulto , Austria , Niño , Preescolar , Diabetes Mellitus/diagnóstico , Diabetes Gestacional/diagnóstico , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Lactante , Recién Nacido , Masculino , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA