Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Vasc Bras ; 23: e20230135, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38433984

RESUMEN

Background: Open abdominal aortic aneurysm (AAA) repair can lead to sexual dysfunction (SD) in men. Objectives: To determine the prevalence of SD following open AAA repair, explore whether surgical techniques for aortic reconstruction can have a differential impact on the occurrence of SD, and summarize current knowledge in this field. Methods: Retrospective review of 100 patients submitted to open AAA repair between 1995 and 2010 in a quaternary center. Sexual dysfunction was assessed according to questions from the modified International Index of Erectile Function (IIEF), considering the condition before surgical repair and 3 months after surgery. The chi-square test, Fisher's exact test, and Student's t test were used for statistical analyses. Results: 100 patients were included (mean age = 66.4 years old). Normal sexual activity, no sexual activity, erectile dysfunction, and retrograde ejaculation with preserved erectile function were found in 36%, 21%, 18%, and 24% of patients, respectively. The group of patients with no sexual activity was older (mean age = 72.3 years old vs 64.5 years old, p < 0.001). Erectile dysfunction prevalence was higher in patients submitted to an aorto-bifemoral bypass (p = 0.032). Retrograde ejaculation was more frequent in patients submitted to an aorto-aortic bypass (p = 0.007). Conclusions: Sexual function is a frequent condition intimately associated with the aortic reconstruction technique. The literature review found contradictory results regarding whether the endovascular approach is protective compared with open repair, but clearly demonstrated the importance of techniques targeting preservation of the internal iliac artery and the superior hypogastric plexus.


Contexto: A correção aberta de aneurisma da aorta abdominal (AAA) pode causar disfunção sexual (DS) em homens. Objetivos: Determinar a prevalência de DS após correção aberta de AAA, determinar se a técnica de reconstrução aórtica pode estar correlacionada com o surgimento de DS e resumir os achados mais relevantes da literatura relacionados a esse tema. Métodos: Estudo retrospectivo de todos os pacientes submetidos a correção aberta de AAA entre 1995 e 2010 num centro quaternário. A DS foi avaliada por meio de questões baseadas no escore International Index of Erection Function no pré-operatório e 3 meses após a cirurgia. A análise estatística foi realizada com os testes do qui-quadrado, exato de Fisher e t de Student. Resultados: Cem pacientes foram incluídos (idade média = 66.4 anos). Atividade sexual normal, atividade sexual ausente, disfunção erétil (DE) e ejaculação retrógrada (ER) com função erétil preservada foram observadas em 36%, 21%, 18% e 24% dos pacientes, respectivamente. O grupo de pacientes com atividade sexual ausente foi significativamente mais velho (idade média = 72.3 anos vs. 64.5 anos, p < 0.001). A DE foi mais prevalente em pacientes submetidos a enxerto aorto-bifemoral (p = 0.032), enquanto a ER foi mais prevalente em pacientes submetidos a enxerto aorto-aórtico (p = 0.007). Conclusões: A DS é uma condição frequente e intimamente associada à reconstrução aórtica empregada. A literatura apresenta resultados contraditórios sobre qual correção de AAA (aberta ou endovascular) resulta em mais DS, mas demonstra a importância de técnicas com preservação das artérias hipogástricas e do plexo hipogástrico superior.

2.
J Vasc Bras ; 23: e20230148, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38433982

RESUMEN

Background: Chronic mesenteric ischemia (CMI) is a debilitating disease with a heavy burden on quality of life. Stenting of the superior mesenteric artery (SMA) is the first option for treatment, but there is a lack of consensus defining precise indications for open revascularization (OR). Objectives: To describe a series of 4 patients with CMI treated with OR and to present an algorithm for the management of this condition. Methods: Three patients presented with typical intestinal angina and weight loss. One patient was subjected to prophylactic revascularization during open abdominal aortic aneurysm repair. Surgical techniques included: 1) Bypass from the infrarenal aorta to the SMA; 2) Bypass from an aorto-bifemoral polyester graft to the SMA; 3) Bypass from the right iliac artery to the SMA; 4) Bypass from the right graft limb of an aorto-biiliac polyester graft to the median colic artery at Riolan's arcade. PTFE was used in all surgeries. All grafts were placed in a retrograde configuration, tunneled under the left renal vein, making a smooth C-loop. A treatment algorithm was constructed based on the institution's experience and a review of recent literature. Results: All patients demonstrated resolution of symptoms and recovery of body weight. All grafts are patent after mean follow-up of two years. Conclusions: Open revascularization using the C-loop configuration is a valuable technique for CMI and may be considered in selected cases. The algorithm constructed may help decision planning in other quaternary centers.


Contexto: A isquemia mesentérica crônica (IMC) é uma doença debilitante, com grave impacto na qualidade de vida. A literatura recomenda a angioplastia com stent da artéria mesentérica superior (AMS) como primeira opção de tratamento, mas há falta de consenso que defina indicações precisas para a revascularização aberta. Objetivos: Descrever uma série de quatro pacientes com IMC, tratados com revascularização aberta, e apresentar um algoritmo para o manejo dessa condição. Métodos: Três pacientes apresentaram angina intestinal típica e perda ponderal. Uma paciente foi submetida a reparo aberto de aneurisma da aorta abdominal e apresentava obstrução da AMS, que foi revascularizada profilaticamente. As técnicas cirúrgicas incluíram: 1) enxerto entre a aorta infrarrenal e a AMS; 2) enxerto entre o dácron utilizado em um enxerto aortobifemoral e a AMS; 3) enxerto entre a artéria ilíaca comum direita e a AMS; e 4) enxerto entre o ramo direito do dácron utilizado em um enxerto aorto-biilíaco e a artéria cólica média (ao nível da arcada de Riolan). Todos os enxertos foram feitos utilizando politetrafluoretileno em uma configuração retrógrada, tunelizados abaixo da veia renal esquerda, fazendo uma alça em C. Resultados: Todos os pacientes demonstraram resolução dos sintomas e ganho ponderal. Todos os enxertos se mantiveram pérvios durante um seguimento médio de 2 anos. Conclusões: A revascularização aberta para IMC utilizando-se a alça em C é uma técnica valiosa e pode ser considerada em pacientes selecionados. O algoritmo proposto pode auxiliar na decisão terapêutica em centros quaternários.

3.
Clin Oral Implants Res ; 34(6): 627-638, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37084177

RESUMEN

OBJECTIVES: To evaluate the sequential osseointegration of a novel titanium implant system based on a 3D printing technology in comparison with conventional titanium implants. MATERIAL AND METHODS: Two novel titanium implants based on 3D printing were tested in the mandible of eight Beagle dogs. As a control, two different commercially available titanium implants were used. The implants were staged to accommodate healing periods of 2 and 6 weeks. The primary outcome variable was bone-to-implant contact (BIC) in non-decalcified tissue sections and micro-CT analysis. RESULTS: Histomorphometrically, the proportions of tissues adjacent to the implant surfaces were similar for all implants, whereas the BIC percentage of new mineralized bone was greater for the control implants after both 2 and 6 weeks (p < .05). Micro-CT analysis revealed increasing osseous volume and BIC from 2 to 6 weeks. In contrast to the histomorphometry, the BIC evaluation with the micro-CT data revealed a significantly higher BIC for the two test implants compared with controls (p < .001). The analysis of the total implant surface area disclosed a value that was approximately double as high for the test compared to the control implants. CONCLUSIONS: The novel titanium implant system based on 3D printing yielded values for osseointegration that were adequate and satisfactory. The higher percentage of new mineralized bone in the control implants is explained by the fact of a completely different three-dimensional surface area.


Asunto(s)
Implantes Dentales , Oseointegración , Perros , Animales , Titanio , Mandíbula/cirugía , Impresión Tridimensional , Propiedades de Superficie
4.
J Vasc Bras ; 22: e20230101, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38021278

RESUMEN

This study aims to describe a case series of patients who underwent thoracic duct embolization (TDE) to treat traumatic iatrogenic chylothorax (TIC). Three patients were included: Case #1, a 49-year-old woman with follicular lymphoma developed a TIC following video-assisted thoracoscopic surgery to resect a solid right paravertebral mass and was treated with TDE using microcoils and N-butyl cyanoacrylate (NBCA) glue. Case #2, a 68-year-old man with cardiac amyloidosis developed a TIC following heart transplantation and was treated with TDE using microcoils and ethylene vinyl alcohol copolymer. Case#3: A 6-year-old patient with congenital heart disease developed a TIC following a Fontan procedure and was treated with TDE using NBCA glue. All lesions were identified during lymphangiography and TDE was successfully performed in all cases. TDE is a safe and valuable technique that provides minimally invasive treatment for TCI.


Este estudo objetiva descrever uma série de casos de pacientes submetidos a embolização do ducto torácico (EDT) para tratamento de quilotórax iatrogênico (QI). Três pacientes foram incluídos. Caso 1: um homem de 49 anos com linfoma folicular apresentou QI após ressecção de uma massa paravertebral por toracoscopia vídeo-assistida e foi submetido a EDT com micromolas e n-butil-cianoacrilato (NBCA). Caso 2: um homem de 68 anos com amiloidose cardíaca apresentou QI após ser submetido a transplante cardíaco e foi submetido a EDT com micromolas e copolímero de etileno e álcool vinílico. Caso 3: um paciente de 6 anos com malformação cardíaca congênita apresentou QI após cirurgia de Fontan e foi submetido a EDT com NBCA. Todas as lesões foram identificadas durante a linfangiografia, e a EDT foi realizada com sucesso. A EDT é uma técnica segura e valiosa, que pode oferecer um tratamento minimamente invasivo em casos de QI.

5.
J Vasc Bras ; 22: e20230018, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38021280

RESUMEN

A 100-year-old male patient was admitted with a ruptured abdominal aortic aneurysm due to type IA endoleak. Given the proximity of the ruptured site to the superior mesenteric artery (SMA) and renal arteries, a ChEVAR was indicated. Catheterization of the target visceral vessels was a challenging procedural step because of an intensely tortuous thoracic aorta. This hostile aortic anatomy also inhibited exchange for a super stiff guide-wire and selective cannulation with the diagnostic catheter was repeatedly lost when guidewire exchange was attempted. To overcome this issue, a 5 x 40 mm balloon catheter was placed 3cm into the target arteries. The balloon was then inflated below the nominal pressure limit enabling safe exchange for a super stiff guidewire and placement of three 90-cm long 7Fr guiding sheaths. The procedure was thus safely performed with deployment of an aortic extension and the bridging stents.


Um paciente de 100 anos foi diagnosticado com um aneurisma de aorta abdominal roto por um endoleak 1A. Pela proximidade do ponto de ruptura com a artéria mesentérica superior (AMS) e as artérias renais, um ChEVAR foi indicado. A cateterização das artérias-alvo foi um passo desafiador pela intensa tortuosidade da aorta torácica. Essa anatomia aórtica hostil também impediu a troca por um fio-guia extra-rígido, e a cateterização seletiva foi repetidamente perdida quando a troca de fio-guia foi tentada. Para superar essa dificuldade, um cateter balão 5mm x 40mm foi posicionado nas artérias-alvo. O balão foi, então, insuflado abaixo da pressão nominal, permitindo uma troca segura do fio-guia por um fio-guia extra-rígido e o posicionamento de três bainhas longas 7Frx 90cm. Assim, o procedimento foi executado de forma segura, com o implante de uma extensão aórtica e dos stents recobertos.

6.
J Vasc Bras ; 20: e20200174, 2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-34093691

RESUMEN

Ruptured abdominal aortic aneurysms (RAAA) evolving aortocaval fistula (AF) can have catastrophic hemodynamic effects. Surgical repair is imperative, but the optimal technical approach is still under debate. Our objective is to present 3 cases treated with endovascular repair (EVAR) at a University Hospital. Case #1, a 71-year-old man presenting a 7.1cm RAAA with AF, repaired with a monoiliac stent graft and femoral-femoral bypass; Case #2, a 76-year-old man presenting a 9.9cm RAAA with AF, repaired with a bifurcated stent graft; Case #3, a 67-year-old man with previous history of EVAR, presenting a type 3 endoleak with late rupture related to AF, repaired with a tubular stent graft. All cases unfolded with delayed recovery and significant complication rates, although AF symptoms had resolved by hospital discharge. EVAR techniques for AF may require secondary interventions but are feasible, despite the lack of consensus, considering the rarity of this RAAA presentation.


Aneurismas de aorta abdominal rotos (AAAR) com evolução para fístula aorto-cava (FAC) podem apresentar consequências hemodinâmicas catastróficas. A correção cirúrgica é mandatória, embora não haja consenso sobre a técnica operatória. Apresentamos uma série de três casos operados em hospital universitário pela técnica endovascular. No primeiro caso, um homem de 71 anos apresentou AAAR de 7,1 cm com FAC, submetido a correção por endoprótese monoilíaca e enxerto femoral cruzado. No segundo, um homem de 76 anos apresentou AAAR de 9,9 cm com FAC submetido a colocação de endoprótese bifurcada. O terceiro caso era de um homem de 67 anos com histórico de EVAR e endoleak tipo 3, com ruptura tardia para veia cava, tratado com extensão aórtica. Todos apresentaram evolução pós-operatória prolongada com significativas complicações, entretanto com boa resolução dos sintomas à alta hospitalar. A EVAR é uma técnica promissora para o tratamento de FAC, embora com taxa de reintervenção significativa.

7.
J Vasc Bras ; 20: e20200191, 2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-34188669

RESUMEN

BACKGROUND: The contrast power injector (CPI) is the gold standard method for injecting contrast with the pressure and flow needed to generate a satisfactory images during endovascular procedures, but it is an expensive tool, narrowing its wide-scale applications. One alternative is the manual injection (MI) method, but this does not generate the pressure required for adequate visualization of anatomy. It is therefore imperative to create an alternative low-cost method that is capable of producing high quality images. OBJECTIVES: To compare the injection parameters of a new mechanical device (Hand-Crank) created in a university hospital with the MI method and with the contrast power injector's ideal values. METHODS: A circulation phantom was constructed to simulate the pressure in the aorto-iliac territory and the injection parameters of the two methods were compared in a laboratory setting. Student's t test and the Mann-Whitney test were used for statistical analysis. Three vascular surgery residents (the authors) performed the injections (each performed 9 tests using conventional manual injection and 9 tests using the Hand-Crank, totaling 54 injections). RESULTS: There were statistical differences between the two methods (p<0.05) in total volume injected until maximum pressure was attained, pressure variation, maximum pressure, total injection time, and time to reach the maximum pressure. CONCLUSIONS: The Hand-Crank can achieve higher maximum pressure, higher average flow, and lower injection time than the manual method. It is a simple, low-cost, and effective tool for enhancing injection parameters in an experimental setup. It could help to produce higher quality images in a clinical scenario.


CONTEXTO: A bomba injetora é o método padrão-ouro para a injeção de contraste em aortografias. Entretanto, é uma ferramenta de alto custo, o que limita o seu uso. A injeção manual surge como alternativa, mas a pressão gerada com esse método é baixa, e, por isso, a qualidade das imagens não é usualmente satisfatória. Assim, a criação de um método de baixo custo capaz de gerar imagens de qualidade é imperativo. OBJETIVOS: Comparar os parâmetros de injeção de um novo dispositivo mecânico (manivela articulada) criado em um hospital universitário com os parâmetros da injeção manual e com os valores ideais da bomba injetora. MÉTODOS: Um simulador do território aórtico foi construído, e parâmetros de injeção entre os diferentes métodos em um cenário laboratorial controlado foram analisados. O teste t de Student e o teste de Mann-Whitney foram usados para análise estatística. Três residentes de Cirurgia Vascular realizaram os testes (nove usando o novo dispositivo, e nove usando a injeção manual, totalizando 54 injeções). RESULTADOS: Houve diferença estatisticamente significativa (p < 0,05) entre os dois métodos, considerando os parâmetros: variação de pressão, pressão máxima, tempo de injeção, tempo até a pressão máxima e volume até a pressão máxima. CONCLUSÕES: A manivela articulada atingiu níveis superiores de pressão e de velocidade de injeção, com menor tempo de injeção do que a injeção manual. É um dispositivo simples, de baixo custo e com resultados comparáveis à bomba injetora, o que sugere seu uso potencial na geração de imagens satisfatórias em aortografias.

8.
Ann Vasc Surg ; 69: 345-351, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32504789

RESUMEN

BACKGROUND: Several studies in the literature report continued proximal aorta and distal iliac artery dilatation after surgical correction of an abdominal aortic aneurysm (AAA). The purpose of this study is to evaluate these findings, in a South American population, and relate them to the type of configuration of the open procedure aortic reconstruction. METHODS: This is a retrospective review of ultrasonographic follow-up of patients submitted to open repair of AAA from 1989 to 2013, reporting proximal aorta dilatation (≥3 cm) and distal iliac artery dilatation (≥1.5 cm). RESULTS: A total of 155 patients were included. Life-table freedom at the intervals 11 < 15 years and ≥15 years were 47% and 23% for proximal dilatation and 63% and 38% for distal iliac arteries dilatation, respectively. There were more proximal and distal dilatations in patients submitted to more extensive aortic reconstructions (aorto-aortic 13% and 22% vs aorto-bilateral common iliacs 27% and 8% vs aorto-unilateral or bilateral external iliacs 27% and 32% and aorto-femoral 67% and 0%) P < 0.0001. Juxtarenal anastomosis was also correlated with more proximal dilatations (42% vs 21%, P = 0,046). There were two proximal and three distal anastomosis pseudoaneurysms. CONCLUSIONS: The presence of more extensive degenerative disease at the time of operation, requiring juxtarenal or more distal iliac reconstructions, may pose an increased risk of proximal aorta and iliac artery dilatation during follow-up. This study corroborates that significant changes are found after 7 to 10 years of the operation, reinforcing the need for long-term monitoring.


Asunto(s)
Aneurisma Falso/patología , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta/patología , Implantación de Prótesis Vascular/efectos adversos , Arteria Ilíaca/cirugía , Remodelación Vascular , Anciano , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/epidemiología , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/patología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/epidemiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/epidemiología , Aneurisma de la Aorta Abdominal/patología , Brasil/epidemiología , Dilatación Patológica , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Ergonomics ; 57(2): 210-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24428598

RESUMEN

Certain underwater circumstances carry risk of inert gas narcosis. Impairment of sensorimotor information processing due to narcosis, induced by normobaric nitrous oxide or high partial nitrogen pressure, has been broadly evidenced, by a lengthening of the reaction time (RT). However, the locus of this effect remains a matter of debate. We examined whether inert gas narcosis affects the response-selection stage of sensorimotor information processing. We compared an air normobaric condition with a hyperbaric condition in which 10 subjects were subjected to 6 absolute atmospheres of 8.33% O2 Nitrox. In both conditions, subjects performed a between-hand choice-RT task in which we explicitly manipulated the stimulus-response association rule. The effect of this manipulation (which is supposed to affect response-selection processes) was modified by inert gas narcosis. It is concluded, therefore, that response selection processes are among the loci involved in the effect of inert gas narcosis on information processing.


Asunto(s)
Conducta de Elección/efectos de los fármacos , Narcosis por Gas Inerte/psicología , Personal Militar/psicología , Nitrógeno/efectos adversos , Oxígeno/efectos adversos , Tiempo de Reacción/efectos de los fármacos , Adulto , Presión del Aire , Buceo , Francia , Humanos , Narcosis por Gas Inerte/etiología , Narcosis por Gas Inerte/fisiopatología , Masculino , Medicina Naval , Desempeño Psicomotor/efectos de los fármacos
13.
Cardiovasc Intervent Radiol ; 47(8): 1127-1133, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38890185

RESUMEN

PURPOSE: To describe a single-center experience with robotic-assisted endovascular treatment for transplant renal artery stenosis. MATERIALS AND METHODS: This is a single-center, retrospective, feasibility study of 4 consecutive cases of robotic-assisted endovascular surgery for transplant renal artery stenosis from October 2021 to August 2022. RESULTS: All lesions were identified, and stenting was performed with no complications. Conversion to manual control was not necessary. The mean fluoroscopy time was 25.25 min (range 12-60.9). A control Doppler ultrasound was routinely performed, demonstrating no residual lesions in all cases. There was no reintervention during the follow-up period. The operator learning curve was felt to be acceptable. CONCLUSION: Robotic-assisted endovascular treatment is a feasible technique for transplant renal artery stenosis.


Asunto(s)
Procedimientos Endovasculares , Estudios de Factibilidad , Trasplante de Riñón , Obstrucción de la Arteria Renal , Procedimientos Quirúrgicos Robotizados , Humanos , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/cirugía , Obstrucción de la Arteria Renal/terapia , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Endovasculares/métodos , Stents , Adulto , Resultado del Tratamiento , Anciano , Arteria Renal/diagnóstico por imagen , Arteria Renal/cirugía
14.
Vasc Endovascular Surg ; : 15385744241280331, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256060

RESUMEN

BACKGROUND: Bronchial stenosis associated with bronchial anastomosis dehiscence after lung transplantation is a catastrophic complication following lung transplantation with a paucity of therapeutic solutions. PURPOSE: To describe an adaptation of the parallel stent grafting technique in the pulmonary arterial territory to treat this challenging situation. RESEARCH DESIGN: This is a case report of a 52-year-old patient who presented bronchus stenosis and bronchial anastomosis dehiscence after lung transplantion. Bronchial stenting and lung retransplantation were contraindicated. Therefore, an endovascular approach using pulmonary artery endograft placement to prevent bleeding during repeated right bronchial balloon dilation was propposed. The technique consists of the deployment of an aortic extender endoprosthesis in the right main pulmonary artery and a balloon expandable stent in the upper lobe pulmonary artery (using a parallel graft configuration) through the common femoral and right internal jugular veins, respectively. Intraoperative transesophageal echocardiogram and one-lung ventilatory ventilation are needed. RESULTS: The patient underwent a new bronchoscopy 16 days after the procedure, that showed epithelization at the previous eroded zone, enabling bronchocopic balloon dialtion to be safely performed. A post-operative contrast-enhanced CT scan revealed an adequate positioning of the stent grafts. Despite all eforts, the patient succumbed to ventilator associated pneumonia on postoperative day 108. DATA ANALYSIS: The technique's advantages include its feasibility even in situations in which other techniques may be contraindicated and its potential use in emergencies. Its limitations include the need for experienced interventionists to perform it, and the potential risk of acute tricuspid regurgitation. CONCLUSION: This study illustrates the early feasibility of the parallel stent grafting technique applied to the pulmonary artery territory. However, it's safety profile regarding infectious risk was not demontrated.

15.
Diagn Interv Radiol ; 29(4): 628-631, 2023 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-36994971

RESUMEN

Diving thyroid nodules are a limitation of radiofrequency ablation because the mediastinal component cannot be adequately identified by ultrasound (US). We aim to describe a new technique, the iceberg technique, to overcome this issue and explain our three-year experience of using this novel method. The iceberg technique consists of a two-stage treatment. First, the ablation of the cervical portion of the nodules (easily visualized during the initial US exam) using trans-isthmic access is performed using the moving-shot technique. After three to six months, there is a volumetric reduction of the treated portion, leading to retraction of the thyroid parenchyma. This brings the mediastinal component to the cervical region, thereby enabling a perfect visualization by US. Then, the second stage of treatment is carried out with complete nodule ablation, and the region that was treated first is looked at a second time. From April 2018 to April 2021, nine patients with nine benign nodules were submitted for the iceberg technique. No complications occurred during the entire follow-up period. The patients displayed normal hormonal levels after the procedures, and there was a significant volume reduction of the nodules until three months post-ablation. The iceberg technique is an effective and safe option for the radiofrequency treatment of diving goiters.


Asunto(s)
Ablación por Catéter , Buceo , Ablación por Radiofrecuencia , Nódulo Tiroideo , Humanos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/cirugía , Resultado del Tratamiento , Ablación por Radiofrecuencia/métodos , Ablación por Catéter/métodos , Estudios Retrospectivos
16.
Einstein (Sao Paulo) ; 21: eAO0307, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909650

RESUMEN

OBJECTIVE: To describe the radiological characteristics of hepatocellular carcinoma (HCC) lesions that achieved a complete response following drug-eluting bead transarterial chemoembolization (DEB-TACE) preceding liver transplantation. METHODS: This single-center case-control study enrolled patients with hepatocellular carcinoma who underwent neoadjuvant DEB-TACE therapy, were followed up with contrast-enhanced magnetic resonance imaging or computed tomography, and were successively evaluated according to the modified Response Evaluation Criteria in Solid Tumors. The HCCs were divided into two groups based on their diameter (Group A: ≤3cm; Group B: 3cm). Viability was assessed using the Kaplan-Meier method according to tumor size categories. The relationship between tumor variables was analyzed using bivariate Cox regression. RESULTS: Three-hundred and twenty-eight patients with 667 hepatocellular carcinomas who underwent their first DEB-TACE session were enrolled. A total of 105 hepatocellular carcinomas in 59 patients exhibited complete response after the initial DEB-TACE session and were divided into Group A (92 HCCs) and Group B (13 HCCs). The diameter in Group A decreased significantly compared to the pre-procedure size until the second assessment (p<0.001), with no subsequent reduction in diameter, despite maintaining a complete response. In Group B, the reduction in diameter remained significant compared with the initial value until the sixth imaging evaluation (p=0.014). The average reduction was 45.1% for Group B and a maximum of 14.9% in Group A. CONCLUSION: HCCs >3cm exhibited a greater reduction in size and a longer time to recurrence. HCCs ≤3cm had a shorter relapse time. The recurrence rates were similar. These findings may aid in planning for liver transplantation.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Trasplante de Hígado , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Estudios de Casos y Controles , Quimioembolización Terapéutica/métodos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/terapia , Estudios Retrospectivos
17.
Case Rep Oncol ; 16(1): 711-717, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37933309

RESUMEN

Primary transitional cell carcinoma of the ureter is a rare type of cancer with metastasis presented in approximately 25% at diagnosis. Due to its rarity and poor prognosis, the management of this neoplasm is still controversial, and the development of new therapies is of uttermost importance. Herein, we describe a case of a 54-year-old patient diagnosed with transitional cell carcinoma of the left ureter submitted to left nephroureterectomy (pT3N2M0) and methotrexate, vinblastine, doxorubicin, and cisplatin adjuvant chemotherapy. A single liver metastasis was detected and combination chemotherapy with gemcitabine and carboplatin was initiated along with stereotactic body radiation therapy. Despite these 2 previous chemotherapy regimens, the patient presented disease progression and transarterial selective internal radiation therapy (SIRT) with yttrium-90 was indicated. This locoregional treatment was performed with the administration of 1.2 GBq yttrium-90 resin microspheres (SIR-Spheres®, Sirtex Medical Limited, Sydney, NSW, Australia) into the right hepatic artery. Another systemic treatment was immunotherapy using nivolumab with excellent tolerability. After 10 years of follow-up, at the last clinical evaluation, the patient had no clinical symptoms and the last imaging follow-up using positron emission tomography-computed tomography scan showed complete response. This report introduces upper urinary tract urothelial carcinoma as a distinct type of malignancy in which SIRT can be safely implemented. As a transition method to nivolumab, it was successful. There might be a potential therapeutic synergism between these 2 treatment modalities.

18.
Einstein (Sao Paulo) ; 20: eAO6665, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35476085

RESUMEN

OBJECTIVE: To describe an experience in the preoperative localization of small pulmonary nodules and ground-glass lesions to guide minimally invasive thoracic surgery; in addition, a literature review was conducted, including the main advantages and disadvantages of the different agents used, and site marking in a hybrid operating room. METHODS: A retrospective search was conducted in a Interventional Radiology Department database, between March 2015 and May 2019, to identify patients undergoing preoperative percutaneous marking of lung injuries measuring up to 25mm. RESULTS: A total of 20 patients were included and submitted to descriptive analysis. All patients were marked in a hybrid room, at the same surgical-anesthetic time. Most often used markers were guidewire, Lipiodol® and microcoils. Despite one case of coil displacement, two cases of pneumothorax, and one case of hypotension after marking, all lesions were identified and resected accordingly from all patients. CONCLUSION: Preoperative percutaneous localization of lung injuries in hybrid room is an effective and a safe technique, which can have decisive impact on surgical resection. The choice of marker and of the operating room scenario should be based on availability and experience of service. Multidisciplinary discussions with surgical teams, pathologists, and interventional radiologists are crucial to improve outcome of patients.


Asunto(s)
Lesión Pulmonar , Neoplasias Pulmonares , Cirugía Torácica , Humanos , Pulmón/patología , Estudios Retrospectivos , Cirugía Torácica Asistida por Video/métodos , Tomografía Computarizada por Rayos X/métodos
19.
Front Physiol ; 12: 756533, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34916955

RESUMEN

Background: Inspiratory loading is experienced by military divers when they use rebreather device. Our objective was to assess the changes in diaphragm function induced by an increase in inspiratory load at values similar to those experienced by divers in real life. Methods: We recorded the excursion and the thickness of the right hemidiaphragm in 22 healthy male volunteers under inspiratory load conditions, using ultrasound in B- and M-mode. The measurements were performed at tidal volume and during breathing at 50% of inspiratory capacity. The breathing rate was regulated and similar in the various sessions with and without load. Results: The rebreather device used by French military divers leads to an increase in inspiratory load of close to 30 cmH2O. Consequently, the session under load was performed using a device set to this threshold. Significant increases in the excursion and the thickening fraction of the diaphragm were observed between the sessions at tidal volume and at high volume. With addition of the inspiratory load, the excursion of the right hemidiaphragm increased significantly from 2.3 to 3.4cm at tidal volume and from 3.9 to 4.7cm at high volume. The thickening fraction increased significantly from 30.4 to 76.6% at tidal volume and from 70 to 123% at high volume. The statistical analysis demonstrated that assessment of the changes of the thickening fraction during breathing at tidal volume was the most relevant marker to assess the impact of the inspiratory load on the diaphragm. Conclusion: Diaphragm ultrasound can be used to assess the changes in the diaphragm contraction pattern secondary to an increase in the respiratory load that can be generated by use a diving apparatus. The recording of the changes of the motion, and more importantly of the thickness of the diaphragm, during the breathing cycle is able to provide relevant information regarding the inspiratory load.

20.
Sci Rep ; 11(1): 9434, 2021 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-33941815

RESUMEN

Head-out water immersion alters respiratory compliance which underpins defining pressure at a "Lung centroid" and the breathing "Static Lung Load". In diving medicine as in designing dive-breathing devices a single value of lung centroid pressure is presumed as everyone's standard. On the contrary, we considered that immersed respiratory compliance is disparate among a homogenous adult group (young, healthy, sporty). We wanted to substantiate this ample scattering for two reasons: (i) it may question the European standard used in designing dive-breathing devices; (ii) it may contribute to understand the diverse individual figures of immersed work of breathing. Resting spirometric measurements of lung volumes and the pressure-volume curve of the respiratory system were assessed for 18 subjects in two body positions (upright Up, and supine Sup). Measurements were taken in air (Air) and with subjects immersed up to the sternal notch (Imm). Compliance of the respiratory system (Crs) was calculated from pressure-volume curves for each condition. A median 60.45% reduction in Crs was recorded between Up-Air and Up-Imm (1.68 vs 0.66 L/kPa), with individual reductions ranging from 16.8 to 82.7%. We hypothesize that the previously disregarded scattering of immersion-reduced respiratory compliance might participate to substantial differences in immersed work of breathing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA