Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39165139

RESUMEN

BACKGROUND: Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction-associated steatohepatitis. PURPOSE: To compare the performance of 2D/3D-MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D-MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. STUDY TYPE: Prospective. POPULATION: One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46-65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27-34]; 5 females). FIELD STRENGTH/SEQUENCE: Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC-MRE (2D-MRE, spin-echo EPI sequence, 11 seconds breath-hold), and second, using GT-MRE (2D- and 3D-MRE, gradient-echo sequence, 14 seconds breath-hold). ASSESSMENT: Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. STATISTICAL TESTS: Spearman's correlation coefficient (r) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland-Altman bias and reproducibility coefficients. P-values <0.05 were considered statistically significant. RESULTS: Liver stiffness quantified via GT-2D/3D correlated well with AC-2D (r ≥ 0.89 [95% CI: 0.85-0.92]) and histopathological grading (r ≥ 0.84 [95% CI: 0.72-0.91]), demonstrating excellent agreement in Bland-Altman plots and between readers (κ ≥ 0.86 [95% CI: 0.81-0.91]). However, GT-2D showed a bias in overestimating stiffness compared to GT-3D. Proposed QIs enabled the identification of pixels deviating beyond 10% from true stiffness based on a combination of total wave amplitude, temporal sinusoidal nonlinearity, and wave signal-to-noise ratio for GT-3D. CONCLUSION: GT-MRE represents an alternative to AC-MRE for noninvasive liver tissue characterization. Both GT-2D and 3D approaches correlated strongly with the established commercial approach, offering advanced capabilities in abdominal imaging compared to AC-MRE. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

2.
Eur Radiol ; 34(8): 5370-5378, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38221584

RESUMEN

BACKGROUND: Although core needle biopsy is an important tool in minimally invasive tissue sampling and diagnostics for head and neck masses, comprehensive data about safety and outcomes is lacking. PURPOSE: To retrospectively evaluate the diagnostic performance and safety of computed tomography (CT)-guided percutaneous core needle biopsy of head and neck masses. MATERIAL AND METHODS: This retrospective single-center study included patients from 04/2007 to 12/2021, and a total of 156 core needle biopsies were evaluated. The initial histopathological results were compared with the long-term final diagnosis to evaluate the diagnostic yield of CT-guided core needle biopsies. The patients' age, sex, and history of malignancy, as well as procedural complications and radiation exposure were collected. RESULTS: A total of 156 biopsies of 150 patients (mean age 56 years ± 17; 89 men) were evaluated. 57.3% (86/150) of patients had a history of malignancy. 55.1% (86/156) of the lesions were accessed by an infrahyoid needle approach. 92.9% (145/156) of biopsies yielded conclusive results. There were no false positives and 4 false negatives, resulting in a total false negative rate of 2.7% (4/145) and a total diagnostic yield of 90.4% (141/156). There were nine puncture-related complications (9/156-5.7%). None of the complications required further reintervention. The average dose length product was 311.3 mGy × cm. CONCLUSION: CT-guided core needle biopsies of head and neck masses showed excellent results with high diagnostic yield and clinical safety. CLINICAL RELEVANCE STATEMENT: General anesthesia for open biopsy carries a higher risk for elderly patients, and fine needle aspiration has a poor reputation in terms of its diagnostic yield. This study focuses on safety and diagnostic yield of CT-guided core needle biopsies. KEY POINTS: • CT-guided core needle biopsy in head and neck tumors was a reliable and safe procedure. • The most common cause for an inconclusive biopsy result was a shortage of tissue collected during the biopsy. • During our study period of nearly 15 years, the radiation exposure of head and neck biopsies decreased.


Asunto(s)
Neoplasias de Cabeza y Cuello , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Biopsia Guiada por Imagen/métodos , Biopsia con Aguja Gruesa/métodos , Biopsia con Aguja Gruesa/efectos adversos , Radiografía Intervencional/métodos , Anciano , Adulto , Anciano de 80 o más Años
3.
J Comput Assist Tomogr ; 48(2): 323-333, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38013237

RESUMEN

OBJECTIVE: Our study objective was to explore the additional value of dual-energy CT (DECT) material decomposition for squamous cell carcinoma of the head and neck (SCCHN) survival prognostication. METHODS: A group of 50 SCCHN patients (male, 37; female, 13; mean age, 63.6 ± 10.82 years) with baseline head and neck DECT between September 2014 and August 2020 were retrospectively included. Primary tumors were segmented, radiomics features were extracted, and DECT material decomposition was performed. We used independent train and validation datasets with cross-validation and 100 independent iterations to identify prognostic signatures applying elastic net (EN) and random survival forest (RSF). Features were ranked and intercorrelated according to their prognostic importance. We benchmarked the models against clinical parameters. Intraclass correlation coefficients were used to analyze the interreader variation. RESULTS: The exclusively radiomics-trained models achieved similar ( P = 0.947) prognostic performance of area under the curve (AUC) = 0.784 (95% confidence interval [CI], 0.775-0.812) (EN) and AUC = 0.785 (95% CI, 0.759-0.812) (RSF). The additional application of DECT material decomposition did not improve the model's performance (EN, P = 0.594; RSF, P = 0.198). In the clinical benchmark, the top averaged AUC value of 0.643 (95% CI, 0.611-0.675) was inferior to the quantitative imaging-biomarker models ( P < 0.001). A combined imaging and clinical model did not improve the imaging-based models ( P > 0.101). Shape features revealed high prognostic importance. CONCLUSIONS: Radiomics AI applications may be used for SCCHN survival prognostication, but the spectral information of DECT material decomposition did not improve the model's performance in our preliminary investigation.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radiómica , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen
4.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38872126

RESUMEN

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Asunto(s)
Implantes Cocleares , Tomografía Computarizada de Haz Cónico , Dosis de Radiación , Hueso Temporal , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Masculino , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Hueso Temporal/diagnóstico por imagen , Anciano , Adulto , Implantación Coclear/métodos
5.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38523224

RESUMEN

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Automático , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagen , Masculino , Femenino , Pronóstico , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Anciano , Biomarcadores/sangre , Valor Predictivo de las Pruebas , Estudios Retrospectivos
6.
NMR Biomed ; 36(2): e4828, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36082477

RESUMEN

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Imagen de Cuerpo Entero , Flujo de Trabajo
7.
Eur J Clin Invest ; 53(12): e14075, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37571983

RESUMEN

BACKGROUND: To investigate the potential of radiomic features and dual-source dual-energy CT (DECT) parameters in differentiating between benign and malignant mediastinal masses and predicting patient outcomes. METHODS: In this retrospective study, we analysed data from 90 patients (38 females, mean age 51 ± 25 years) with confirmed mediastinal masses who underwent contrast-enhanced DECT. Attenuation, radiomic features and DECT-derived imaging parameters were evaluated by two experienced readers. We performed analysis of variance (ANOVA) and Chi-square statistic tests for data comparison. Receiver operating characteristic curve analysis and Cox regression tests were used to differentiate between mediastinal masses. RESULTS: Of the 90 mediastinal masses, 49 (54%) were benign, including cases of thymic hyperplasia/thymic rebound (n = 10), mediastinitis (n = 16) and thymoma (n = 23). The remaining 41 (46%) lesions were classified as malignant, consisting of lymphoma (n = 28), mediastinal tumour (n = 4) and thymic carcinoma (n = 9). Significant differences were observed between benign and malignant mediastinal masses in all DECT-derived parameters (p ≤ .001) and 38 radiomic features (p ≤ .044) obtained from contrast-enhanced DECT. The combination of these methods achieved an area under the curve of .98 (95% CI, .893-1.000; p < .001) to differentiate between benign and malignant masses, with 100% sensitivity and 91% specificity. Throughout a follow-up of 1800 days, a multiparametric model incorporating radiomic features, DECT parameters and gender showed promising prognostic power in predicting all-cause mortality (c-index = .8 [95% CI, .702-.890], p < .001). CONCLUSIONS: A multiparametric approach combining radiomic features and DECT-derived imaging biomarkers allows for accurate and noninvasive differentiation between benign and malignant masses in the anterior mediastinum.


Asunto(s)
Linfoma , Neoplasias del Mediastino , Neoplasias del Timo , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias del Timo/patología , Linfoma/diagnóstico por imagen , Neoplasias del Mediastino/diagnóstico por imagen
8.
Eur J Clin Invest ; 53(4): e13914, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36444723

RESUMEN

BACKGROUND: D-dimer testing is known to have a high sensitivity at simultaneously low specificity, resulting in nonspecific elevations in a variety of conditions. METHODS: This retrospective study sought to assess diagnostic and prognostic features of D-dimers in cancer patients referred to the emergency department for suspected pulmonary embolism (PE) and deep vein thrombosis (DVT). In total, 526 patients with a final adjudicated diagnosis of PE (n = 83) and DVT (n = 69) were enrolled, whereas 374 patients served as the comparative group, in which venous thromboembolism (VTE) has been excluded. RESULTS: For the identification of VTE, D-dimers yielded the highest positive predictive value of 96% (95% confidence interval (CI), 85-99) at concentrations of 9.9 mg/L and a negative predictive value of 100% at .6 mg/L (95% CI, 97-100). At the established rule-out cut-off level of .5 mg/L, D-dimers were found to be very sensitive (100%) at a moderate specificity of nearly 65%. Using an optimised cut-off value of 4.9 mg/L increased the specificity to 95% for the detection of life-threatening VTE at the cost of moderate sensitivities (64%). During a median follow-up of 30 months, D-dimers positively correlated with the reoccurrence of VTE (p = .0299) and mortality in both cancer patients with VTE (p < .0001) and without VTE (p = .0008). CONCLUSIONS: Although D-dimer testing in cancer patients is discouraged by current guidelines, very high concentrations above the 10-fold upper reference limit contain diagnostic and prognostic information and might be helpful in risk assessment, while low concentrations remain useful for ruling out VTE.


Asunto(s)
Neoplasias , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/diagnóstico , Pronóstico , Estudios Retrospectivos , Productos de Degradación de Fibrina-Fibrinógeno , Valor Predictivo de las Pruebas
9.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37409393

RESUMEN

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Neoplasias , Humanos , Neoplasias/sangre , Neoplasias/complicaciones , Neoplasias/diagnóstico , Valor Predictivo de las Pruebas , Factores de Riesgo , Tromboembolia Venosa/sangre , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevención & control , Bioensayo/normas , Sensibilidad y Especificidad
10.
BMC Med Imaging ; 23(1): 71, 2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37268876

RESUMEN

BACKGROUND: Treatment plans for squamous cell carcinoma of the head and neck (SCCHN) are individually decided in tumor board meetings but some treatment decision-steps lack objective prognostic estimates. Our purpose was to explore the potential of radiomics for SCCHN therapy-specific survival prognostication and to increase the models' interpretability by ranking the features based on their predictive importance. METHODS: We included 157 SCCHN patients (male, 119; female, 38; mean age, 64.39 ± 10.71 years) with baseline head and neck CT between 09/2014 and 08/2020 in this retrospective study. Patients were stratified according to their treatment. Using independent training and test datasets with cross-validation and 100 iterations, we identified, ranked and inter-correlated prognostic signatures using elastic net (EN) and random survival forest (RSF). We benchmarked the models against clinical parameters. Inter-reader variation was analyzed using intraclass-correlation coefficients (ICC). RESULTS: EN and RSF achieved top prognostication performances of AUC = 0.795 (95% CI 0.767-0.822) and AUC = 0.811 (95% CI 0.782-0.839). RSF prognostication slightly outperformed the EN for the complete (ΔAUC 0.035, p = 0.002) and radiochemotherapy (ΔAUC 0.092, p < 0.001) cohort. RSF was superior to most clinical benchmarking (p ≤ 0.006). The inter-reader correlation was moderate or high for all features classes (ICC ≥ 0.77 (± 0.19)). Shape features had the highest prognostic importance, followed by texture features. CONCLUSIONS: EN and RSF built on radiomics features may be used for survival prognostication. The prognostically leading features may vary between treatment subgroups. This warrants further validation to potentially aid clinical treatment decision making in the future.


Asunto(s)
Neoplasias de Cabeza y Cuello , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/terapia , Estudios Retrospectivos , Pronóstico , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia
11.
J Appl Clin Med Phys ; 24(2): e13860, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36565180

RESUMEN

This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95-23.01) to 2.36 µSv (IQR, 0.52-12.66) (-36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 µSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 µSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (-30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Traumatismos por Radiación , Humanos , Dosis de Radiación , Estudios Prospectivos , Retroalimentación Sensorial , Radiometría , Traumatismos por Radiación/prevención & control , Exposición a la Radiación/prevención & control , Exposición Profesional/prevención & control , Radiografía Intervencional , Fluoroscopía
12.
Medicina (Kaunas) ; 59(5)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37241139

RESUMEN

Objective: Minimally invasive direct coronary artery bypass grafting (MIDCAB) using the left internal thoracic artery to the left descending artery is a clinical routine in the treatment of coronary artery disease. Far less is known on right-sided MIDCAB (r-MIDCAB) using the right internal thoracic artery (RITA) to the right coronary artery (RCA). We aimed to present our experience in patients with complex coronary artery disease who underwent r-MIDCAB. Materials and Methods: Between October 2019 and January 2023, 11 patients received r-MIDCAB using RITA to RCA bypass in a minimally invasive technique via right anterior minithoracotomy without using a cardiopulmonary bypass. Underlying coronary disease was complex right coronary artery stenosis (n = 7) and anomalous right coronary artery (ARCA; n = 4). All procedure-related and outcome data were evaluated prospectively. Results: Successful minimally invasive revascularization was achieved in all patients (n = 11). There were no conversions to sternotomy and no re-explorations for bleeding. Furthermore, no myocardial infarction, no strokes, and, most importantly, no deaths were observed. During the follow-up period (median 24 months), all patients were alive and 90% were completely angina free. Two patients received a repeated revascularization after surgery but independently from the RITA-RCA bypass, which was fully competent in both patients. Conclusion: Right-sided MIDCAB can be performed safely and effectively in patients with expected technically challenging percutaneous coronary intervention of the RCA and in patients with ARCA. Mid-term results showed high freedom from angina in nearly all patients. Further studies with larger patient cohorts and more evidence are needed to provide the best revascularization strategy for patients suffering from isolated complex RCA stenosis and ARCA.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Puente de Arteria Coronaria/métodos
13.
Eur Radiol ; 32(1): 234-242, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34226991

RESUMEN

OBJECTIVES: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. METHODS: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. RESULTS: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients' age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. CONCLUSION: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors. KEY POINTS: • Post-operative radiological assessment of the mastoid facial canal and the positional relationship with the CI electrode provide no predictor of post-cochlear implant facial nerve stimulation. • Radiological detection of extracochlear electrode contacts and the previous clinical history of meningitis/encephalitis are two important risk factors for postoperative facial nerve stimulation in cochlear implant patients. • The presence of scala vestibuli electrode insertion as well as the lateral wall electrode type, the younger patient's age, and early onset of SNHL can play important role in the prediction of post-cochlear implant facial nerve stimulation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Anciano , Niño , Cóclea , Nervio Facial/diagnóstico por imagen , Humanos , Apófisis Mastoides/diagnóstico por imagen , Apófisis Mastoides/cirugía , Persona de Mediana Edad , Estudios Retrospectivos
14.
Eur Radiol ; 31(8): 6200-6210, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33501599

RESUMEN

OBJECTIVES: The size of the heart may predict major cardiovascular events (MACE) in patients with stable chest pain. We aimed to evaluate the prognostic value of 3D whole heart volume (WHV) derived from non-contrast cardiac computed tomography (CT). METHODS: Among participants randomized to the CT arm of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE), we used deep learning to extract WHV, defined as the volume of the pericardial sac. We compared the WHV across categories of cardiovascular risk factors and coronary artery disease (CAD) characteristics and determined the association of WHV with MACE (all-cause death, myocardial infarction, unstable angina; median follow-up: 26 months). RESULTS: In the 3798 included patients (60.5 ± 8.2 years; 51.5% women), the WHV was 351.9 ± 57.6 cm3/m2. We found smaller WHV in no- or non-obstructive CAD, women, people with diabetes, sedentary lifestyle, and metabolic syndrome. Larger WHV was found in obstructive CAD, men, and increased atherosclerosis cardiovascular disease (ASCVD) risk score (p < 0.05). In a time-to-event analysis, small WHV was associated with over 4.4-fold risk of MACE (HR (per one standard deviation) = 0.221; 95% CI: 0.068-0.721; p = 0.012) independent of ASCVD risk score and CT-derived CAD characteristics. In patients with non-obstructive CAD, but not in those with no- or obstructive CAD, WHV increased the discriminatory capacity of ASCVD and CT-derived CAD characteristics significantly. CONCLUSIONS: Small WHV may represent a novel imaging marker of MACE in stable chest pain. In particular, WHV may improve risk stratification in patients with non-obstructive CAD, a cohort with an unmet need for better risk stratification. KEY POINTS: • Heart volume is easily assessable from non-contrast cardiac computed tomography. • Small heart volume may be an imaging marker of major adverse cardiac events independent and incremental to traditional cardiovascular risk factors and established CT measures of CAD. • Heart volume may improve cardiovascular risk stratification in patients with non-obstructive CAD.


Asunto(s)
Volumen Cardíaco , Enfermedad de la Arteria Coronaria , Dolor en el Pecho/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo
15.
Eur Radiol ; 29(12): 6539-6549, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31236701

RESUMEN

OBJECTIVES: To evaluate the diagnostic value of Lipiodol distribution in angiography and CT to differentiate between hepatocellular carcinoma (HCC) and benign nodules of LI-RADS 3 and 4 lesions observed in MRI of liver cirrhosis. METHODS: This retrospective study included all patients with liver cirrhosis who had diagnosis of LI-RADS 3 or 4 lesions by MRI who underwent a Lipiodol-based angiography and post-interventional unenhanced CT- and liver biopsy. Two independent radiologists evaluated appearance, contrast enhancement, Lipiodol uptake in angiography, and morphological parameters (size, form, and density) of the lesions in unenhanced post-angiography CT. α-Fetoprotein (AFP) levels and pre-existing liver conditions were additionally taken into consideration. Differences between HCC lesions and benign nodules were analyzed. Sensitivity and specificity were calculated. P < 0.05 was considered as statistically significant. RESULTS: Of 60 patients (men, n = 42 [70.0%]; women, 18 [30.0%]; mean age, 61 ± 9.1 years) 36 (60.0%) had HCC and 24 (40.0%) benign nodules. Clear visibility in angiography (sensitivity [se], 100%; specificity [sp], 87.5%) with homogeneous or lacunar Lipiodol enhancement (se, 86.1%; sp, 100%) in consecutive CT can be diagnosed as HCC lesions in cirrhotic liver. Lesion form (p < 0.001), round or oval, and intense contrast (p < 0.001) are minor features which can facilitate the findings. Furthermore, patients with HCC showed a larger lesion size in CT (p = 0.026). CONCLUSION: Clearly detectable lesions in Lipiodol-based angiography and a homogeneous or lacunar enhancement in post-angiographic non-contrast CT allow for differentiation of intrahepatic lesions classified as LI-RADS 3 or 4 into benign vs. malign liver lesions with high sensitivity and specificity in patients with liver cirrhosis. Definite diagnosis may not require an additional biopsy. KEY POINTS: • Combination of clear visibility in Lipiodol-based angiography and homogeneous or lacunar enhancement in following native CT scan is HCC-defining. • In lesions classified with MRI as LI-RADS 3 or 4, evaluation based on Lipiodol angiography and following plain CT performed is highly sensitive and specific for the differentiation between HCC and benign nodules in a cirrhotic liver. • The results lead to an alternative pathway in the diagnosis of HCC in cirrhotic liver without the need of an additional liver biopsy.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste/farmacocinética , Aceite Etiodizado/farmacocinética , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Angiografía/métodos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/patología , Femenino , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/patología , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
16.
Eur Radiol ; 29(11): 6140-6148, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31049733

RESUMEN

OBJECTIVES: To investigate the association between directly measured density and morphology of coronary artery calcium (CAC) with cardiovascular disease (CVD) events, using computed tomography (CT). METHODS: Framingham Heart Study (FHS) participants with CAC in noncontrast cardiac CT (2002-2005) were included and followed until 2016. Participants with known CVD or uninterpretable CT scans were excluded. We assessed and correlated (Spearman) CAC density, CAC volume, and the number of calcified segments. Moreover, we counted morphology features including shape (cylindrical, spherical, semi-tubular, and spotty), location (bifurcation, facing pericardium, or facing myocardium), and boundary regularity. In multivariate Cox regression analyses, we associated all CAC characteristics with CVD events (CVD-death, myocardial infarction, stroke). RESULTS: Among 1330 included participants (57.8 ± 11.7 years; 63% male), 73 (5.5%) experienced CVD events in a median follow-up of 9.1 (7.8-10.1) years. CAC density correlated strongly with CAC volume (Spearman's ρ = 0.75; p < 0.001) and lower number of calcified segments (ρ = - 0.86; p < 0.001; controlled for CAC volume). In the survival analysis, CAC density was associated with CVD events independent of Framingham risk score (HR (per SD) = 2.09; 95%CI, 1.30-3.34; p = 0.002) but not after adjustment for CAC volume (p = 0.648). The extent of spherically shaped and pericardially sided calcifications was associated with fewer CVD events accounting for the number of calcified segments (HR (per count) = 0.55; 95%CI, 0.31-0.98; p = 0.042 and HR = 0.66; 95%CI, 0.45-0.98; p = 0.039, respectively). CONCLUSIONS: Directly measured CAC density does not predict CVD events due to the strong correlation with CAC volume. The spherical shape and pericardial-sided location of CAC are associated with fewer CVD events and may represent morphological features related to stable coronary plaques. KEY POINTS: • Coronary calcium density may not be independently associated with cardiovascular events. • Coronary calcium density correlates strongly with calcium volume. • Spherical shape and pericardial-sided location of CAC are associated with fewer CVD events.


Asunto(s)
Calcio/metabolismo , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos , Curva ROC , Factores de Riesgo , Estados Unidos/epidemiología
17.
Radiology ; 287(3): 808-815, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29401041

RESUMEN

Purpose To evaluate the frequency and implications of perivascular fat stranding on coronary computed tomography (CT) angiograms obtained for suspected acute coronary syndrome (ACS). Materials and Methods This retrospective registry study was approved by the institutional review board. The authors reviewed the medical records and images of 1403 consecutive patients (796 men, 607 women; mean age, 52.8 years) who underwent coronary CT angiography at the emergency department from February 2012 to March 2016. Fat attenuation, length and number of circumferential quadrants of the affected segment, and attenuation values in the unaffected epicardial and subcutaneous fat were measured. "Cases" were defined as patients with perivascular fat stranding. Patients with significant stenosis but without fat stranding were considered control subjects. Baseline imaging characteristics, ACS frequency, and results of subsequent downstream testing were compared between cases and control subjects by using two-sample t, Mann-Whitney U, and Fisher tests. Results Perivascular fat stranding was seen in 11 subjects, nine with atherosclerotic lesions and two with spontaneous coronary artery dissections, with a mean fat stranding length of 19.2 mm and circumferential extent averaging 2.9 quadrants. The mean attenuation of perivascular fat stranding, normal epicardial fat, and normal subcutaneous fat was 17, -93.2, and -109.3 HU, respectively (P < .001). Significant differences (P < .05) between cases and control subjects included lower Agatston score, presence of wall motion abnormality, and initial elevation of serum troponin level. ACS frequency was 45.4% in cases and 3.8% in control subjects (P = .001). Conclusion Recognition of perivascular fat stranding may be a helpful additional predictor of culprit lesion and marker of risk for ACS in patients with significant stenosis or spontaneous coronary artery dissection. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Enfermedades Vasculares/congénito , Biomarcadores , Anomalías de los Vasos Coronarios/complicaciones , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/lesiones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/complicaciones , Sistema de Registros , Estudios Retrospectivos , Enfermedades Vasculares/complicaciones , Enfermedades Vasculares/diagnóstico por imagen
18.
Eur Radiol ; 28(4): 1365-1372, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29116390

RESUMEN

Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. KEY POINTS: • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Sistemas de Apoyo a Decisiones Clínicas , Sistemas de Información Radiológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros
19.
Eur Radiol ; 28(5): 2143-2150, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29218617

RESUMEN

OBJECTIVES: To investigate the impact of an adaptive detector collimation on the dose parameters and accurateness of scan length adaption at prospectively ECG-triggered sequential cardiac CT with a wide-detector third-generation dual-source CT. METHODS: Ideal scan lengths for human hearts were retrospectively derived from 103 triple-rule-out examinations. These measures were entered into the new scanner operated in prospectively ECG-triggered sequential cardiac scan mode with three different detector settings: (1) adaptive collimation, (2) fixed 64 × 0.6-mm collimation, and (3) fixed 96 × 0.6-mm collimation. Differences in effective scan length and deviation from the ideal scan length and dose parameters (CTDIvol, DLP) were documented. RESULTS: The ideal cardiac scan length could be matched by the adaptive collimation in every case while the mean scanned length was longer by 15.4% with the 64 × 0.6 mm and by 27.2% with the fixed 96 × 0.6-mm collimation. While the DLP was almost identical between the adaptive and the 64 × 0.6-mm collimation (83 vs. 89 mGycm at 120 kV), it was 62.7% higher with the 96 × 0.6-mm collimation (135 mGycm), p < 0.001. CONCLUSION: The adaptive detector collimation for prospectively ECG-triggered sequential acquisition allows for adjusting the scan length as accurate as this can only be achieved with a spiral acquisition. This technique allows keeping patient exposure low where patient dose would significantly increase with the traditional step-and-shoot mode. KEY POINTS: • Adaptive detector collimation allows keeping patient exposure low in cardiac CT. • With novel detectors the desired scan length can be accurately matched. • Differences in detector settings may cause 62.7% of excessive dose.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía , Tomografía Computarizada Multidetector/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación
20.
Acta Radiol ; 59(8): 909-916, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29105487

RESUMEN

Background Image quality benefits from high-pitch scanning in agitated patients by reducing acquisition time. Purpose To compare image quality and exposure parameters in patients with maxillofacial trauma on second- and third-generation dual-source computed tomography (DSCT). Material and Methods Four groups were compared. Group 1 was examined on second-generation DSCT (120 kV/50 mAs, pitch 3.0). The other three groups were examined on third-generation DSCT. Group 2 was scanned with 120 kV/50 mAs, pitch 2.2. Automated exposure control (AEC) was used in group 3 and group 4 with pitch factors of 2.2 and 3.0, respectively. Images of third-generation DSCT were reconstructed with iterative reconstruction (IR), of second-generation DSCT with filtered back-projection. CTDIvol, acquisition time, and image quality were compared. Results Thirty patients were included in each group. Average CTDIvol (2.76 ± 0.00 mGy, 2.66 ± 0.00 mGy, 0.74 ± 0.23 mGy, and 0.75 ± 0.17 mGy) was significantly lower on third-generation DSCT with AEC ( P < 0.001). Subjective image quality was rated worst in group 4 due to strong high-pitch artifacts, while in the remaining three groups it was rated good or very good with good inter-observer agreement (k > 0.64). Average acquisition time was significantly shorter with third-generation DSCT (0.47 s, 0.36 s, 0.38 s, 0.30 s; P < 0.001). Conclusion Third-generation DSCT yields faster acquisition times and substantial dose reduction with AEC. A pitch of 2.2 should be preferred, as it results in fewer artifacts. If AEC is used, latest IR ensures that diagnostic image quality is guaranteed.


Asunto(s)
Artefactos , Traumatismos Maxilofaciales/diagnóstico por imagen , Senos Paranasales/diagnóstico por imagen , Agitación Psicomotora/complicaciones , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Relación Señal-Ruido , Factores de Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA