Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neurology ; 33(8): 1015-20, 1983 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-6683795

RESUMEN

Using clinical and electrophysiologic measures, we evaluated the visual pathway of patients who had multiple sclerosis, 20/20 Snellen acuity, and no history of optic neuritis. Delayed latencies were found in the transient visual evoked potentials (VEPs) of 38% of the patients, and interocular latency differences were abnormal in 67%. Contrast VEPs were abnormal in 46%. Psychophysical determinations of contrast sensitivity were abnormal in 78%. Only 17% of the patients had dyschromatopsia, 36% had afferent pupillary abnormalities, and 59% had optic nerve pallor or nerve fiber layer loss. Psychophysical contrast evaluations and VEP studies were superior to other clinical evaluations in demonstrating visual dysfunction in these patients.


Asunto(s)
Esclerosis Múltiple/fisiopatología , Trastornos de la Visión/fisiopatología , Potenciales Evocados Visuales , Humanos , Esclerosis Múltiple/complicaciones , Trastornos de la Visión/complicaciones , Agudeza Visual , Vías Visuales/fisiología , Percepción Visual/fisiología
2.
Invest Ophthalmol Vis Sci ; 28(1): 151-7, 1987 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-3804645

RESUMEN

Contrast thresholds for the pattern electroretinogram (PERG) were measured using lock-in amplifier retrieval of the retinal signal and a swept contrast display. Contrast sensitivity functions (CSF) developed from these PERG contrast thresholds were compared with those established psychophysically under identical stimulus conditions. Whereas the PERG CSF showed a band-pass characteristic across temporal frequency, the psychophysical CSF (and a temporal CSF developed from visual evoked potential contrast thresholds) had a low-pass pattern. Across spatial frequency, the PERG and psychophysical CSFs had similar shapes, although the PERG CSF peaked at a lower spatial frequency than the psychophysical CSF.


Asunto(s)
Electrorretinografía/métodos , Visión Ocular/fisiología , Adulto , Potenciales Evocados Visuales , Humanos , Masculino , Psicofísica/métodos , Umbral Sensorial , Percepción Espacial/fisiología , Percepción del Tiempo/fisiología
3.
Invest Ophthalmol Vis Sci ; 24(6): 796-8, 1983 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-6853110

RESUMEN

It is possible to record a pattern electroretinogram (PERG) of near normal amplitude in a situation when the eye containing the active electrode is occluded. Because PERG recording requires high amplification and sensitive signal retrieval techniques, the electrode in the occluded eye records a distant potential from the unoccluded eye. Referencing the active electrode to an ipsilateral ear diminishes, but does not eliminate the referred PERG potential. Such unlooked for interaction may provide misleading data in situations where binocular viewing is used because of poor vision in one eye; therefore, occlusion of the eye not being tested should be undertaken whenever possible.


Asunto(s)
Electrorretinografía/métodos , Adulto , Electrodos , Humanos
4.
Invest Ophthalmol Vis Sci ; 28(9): 1614-6, 1987 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-3623845

RESUMEN

Pattern electroretinogram (PERG) thresholds were examined using a swept contrast stimulus method. Stimulus contrast was either continuously changed (swept) from high to low (descending sweep), or from low to high (ascending sweep). Visual evoked potential (VEP) contrast threshold was higher when measured using descending sweeps than when using ascending sweeps. This VEP threshold difference has been attributed to cortical adaptation. Although previous work has reported changes in the PERG amplitude as a function of pre-exposure, we have found no analogous effect on the PERG threshold.


Asunto(s)
Adaptación Fisiológica , Electrorretinografía/métodos , Visión Ocular/fisiología , Adulto , Potenciales Evocados Visuales , Humanos , Masculino , Umbral Sensorial
5.
Invest Ophthalmol Vis Sci ; 27(7): 1123-30, 1986 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-3721790

RESUMEN

A stimulus consisting of 96 red LEDs mounted in the rear of a ganzfeld bowl was used to elicit focal electroretinograms (FERG) from the central 9 degrees of the retina in human subjects. The luminance of the stimulus was driven sinusoidally at frequencies from 10-60 Hz. The temporal responsiveness and response phase lags of normal subjects and patients with retinal disease were measured. Normal subjects produced maximum amplitude FERG responses to stimuli between 30-40 Hz. Patients with retinitis pigmentosa showed a low-pass pattern of amplitude loss, with an additional frequency independent loss in sensitivity in those with poorer visual acuity. Patients with macular degeneration showed general amplitude loss associated with a relative sparing of the mid-temporal frequencies. The response phase lags in both patient groups were not significantly different from the normals. These findings point to a loss in temporal responsiveness accompanied by a secondary loss of sensitivity in these heredoretinal degenerations.


Asunto(s)
Mácula Lútea/fisiopatología , Degeneración Macular/fisiopatología , Retinitis Pigmentosa/fisiopatología , Adolescente , Adulto , Niño , Electrorretinografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades de la Retina/fisiopatología
6.
Invest Ophthalmol Vis Sci ; 34(9): 2638-45, 1993 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8344787

RESUMEN

PURPOSE: To examine the sites of cone sensitivity loss in patients with retinitis pigmentosa by comparing focal electroretinographic and psychophysical modulation thresholds. METHODS: Both psychophysical and electrophysiologic increment threshold curves were obtained in retinitis pigmentosa patients and a group of age-matched, normally-sighted adults. RESULTS: The majority of the retinitis pigmentosa data could be accounted for by a vertical displacement of the normal curve. The retinitis pigmentosa patients showed similar patterns of cone sensitivity losses using both techniques. CONCLUSIONS: The combined electrophysiologic and psychophysical results provide support for an outer retina locus for these cone sensitivity losses. The data suggest that these deficits may be caused by a spatially independent loss of cone photoreceptors with normal adaptation properties in the remaining photoreceptors.


Asunto(s)
Células Fotorreceptoras/fisiología , Retinitis Pigmentosa/fisiopatología , Adaptación Ocular , Adulto , Electrorretinografía , Humanos , Luz , Persona de Mediana Edad , Psicofísica , Umbral Sensorial
7.
Invest Ophthalmol Vis Sci ; 25(6): 627-31, 1984 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-6724831

RESUMEN

Electrophysiologic contrast sensitivity functions (CSF) have been estimated using lock-in amplifier signal retrieval of the visually evoked response (VER). These CSFs were compared with CSFs obtained psychophysically using the same stimulus conditions. The two measures of contrast sensitivity behave similarly in response to variations of temporal and spatial frequency. The major advantage of using real-time retrieval is speed. Threshold for a single spatiotemporal condition can be estimated in as little as 20 sec, making the application of electrophysiologic contrast sensitivity testing feasible for clinical populations.


Asunto(s)
Potenciales Evocados Visuales , Visión Ocular/fisiología , Adulto , Femenino , Humanos , Masculino , Psicofísica , Agudeza Visual
8.
Invest Ophthalmol Vis Sci ; 25(6): 632-9, 1984 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-6724832

RESUMEN

Multiple sclerosis can produce highly selective losses in visual function. Psychophysical studies have demonstrated contrast sensitivity deficits for spatial frequencies or for stimulus orientations. Using real-time lock-in retrieval of the visual evoked potential, the authors measured contrast sensitivity in 15 cases with probable or definite multiple sclerosis and acuities of 20/40 or better. Sine-wave grating contrast threshold determinations for three spatial frequencies (1, 4, and 8 cycles/deg) and four orientations (0, 45, 90, and 135 deg) revealed contrast deficits in at least one spatial frequency and orientation in every case. In most cases the visual losses were spotty or multifocal, and not the same in both eyes. Some cases with highly selective patterns of orientation or spatial frequency losses were observed and are discussed in terms of involvement of cortical functional architecture in the disease.


Asunto(s)
Esclerosis Múltiple/fisiopatología , Visión Ocular/fisiología , Adulto , Potenciales Evocados Visuales , Femenino , Humanos , Masculino , Agudeza Visual , Corteza Visual/fisiopatología
9.
Am J Ophthalmol ; 108(5): 572-7, 1989 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-2817056

RESUMEN

We assessed the clinical utility of objectively measured acuity using visual-evoked potentials. The technique was first standardized in normal emmetropic subjects and then applied to uncorrected myopic subjects. We found that visual-evoked potential acuity could accurately indicate Snellen acuity in emmetropia and corrected myopia; however, the two measures were highly correlated only in those uncorrected myopic subjects with visual acuities of 20/100 or better. In subjects with poorer than 20/200 uncorrected visual acuity caused by myopia, estimates of visual-evoked potential acuity could not be obtained. The correlation between these two measures of visual acuity was also lower in patients with decreased Snellen acuity attributable to retinal or ocular disease. We found that patients with unexplainable claims of decreased visual acuity could be diagnosed as having functional visual loss based on objective visual-evoked potential acuities.


Asunto(s)
Potenciales Evocados Visuales , Agudeza Visual , Adolescente , Adulto , Anciano , Niño , Estudios de Evaluación como Asunto , Femenino , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Trastornos de la Visión/fisiopatología , Campos Visuales
10.
Am J Ophthalmol ; 113(4): 435-8, 1992 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-1558119

RESUMEN

Eight patients with malignant gliomas were monitored with clinical examinations to study the effects of the combination of intravenous administration of carmustine and infraophthalmic intra-arterial administration of cisplatin on retinal and optic nerve function. Three patients developed a severe macular retinal pigment abnormality in the eye ipsilateral to the intra-arterial infusion. Electrophysiologic studies disclosed no evidence of a generalized disturbance in the photoreceptors, middle retinal layers, or retinal pigment epithelium. In contrast to previous studies involving patients whose visual loss was caused by vaso-occlusive lesions in the retina and optic nerve, our study involved patients with clinically significant maculopathy, that was not vascular in origin and that developed after treatment with carmustine and cisplatin. We suggest that the deficit may result from a localized retinal pigment disturbance in the macula.


Asunto(s)
Carmustina/efectos adversos , Cisplatino/efectos adversos , Mácula Lútea , Enfermedades de la Retina/inducido químicamente , Adulto , Anciano , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Carmustina/uso terapéutico , Cisplatino/uso terapéutico , Electrofisiología , Angiografía con Fluoresceína , Fondo de Ojo , Glioma/tratamiento farmacológico , Glioma/radioterapia , Glioma/cirugía , Humanos , Infusiones Intraarteriales , Inyecciones Intravenosas , Persona de Mediana Edad
11.
J Clin Neurophysiol ; 1(4): 409-36, 1984 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-6544316

RESUMEN

We discuss the use of synchronous-demodulation (lock-in) techniques for evoked potential retrieval. Application to electronically swept visual displays is emphasized. These techniques permit a visual threshold to be specified in 20 s, but their application to visual assessment requires careful consideration of several problems, notably alleged delay in the instrumentation, specification of the baseline response level, and the nature of EEG interference. In addition, since stimulus waveform information is lost in all lock-in methods, questions concerning what activity is contributing to the measured response must be answered. A technique addressing these issues and combining phase-sensitive detection and vector computation is presented.


Asunto(s)
Electrofisiología/métodos , Potenciales Evocados Visuales , Computadores , Electroencefalografía , Humanos , Matemática
12.
Vision Res ; 24(6): 579-86, 1984.
Artículo en Inglés | MEDLINE | ID: mdl-6740979

RESUMEN

Reversing sine wave gratings were electronically swept in spatial frequency and contrast. The acuity limits and contrast thresholds of 4 observers were inferred from evoked potential stimulus-response functions elicited by these stimuli and retrieved with a quadrature lock-in amplifier. The evoked potential functions, linearized in the case of contrast by increasing contrast logarithmically with time, were extrapolated to the point of zero response. This point provides an electrophysiologically defined threshold value for acuity and for contrast. An oblique effect (superior sensitivity for HV-oriented gratings) could reliably be demonstrated in both acuity and contrast threshold performance. This oblique effect could readily be abolished under low spatial/high temporal frequency conditions. The findings are discussed in terms of shifting relative strengths of X and Y contributions to the steady-state evoked potential.


Asunto(s)
Percepción de Forma , Reconocimiento Visual de Modelos , Agudeza Visual , Adulto , Potenciales Evocados Visuales , Femenino , Humanos , Masculino , Umbral Sensorial
13.
Eye (Lond) ; 25(2): 245-51, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21178993

RESUMEN

PURPOSE: To establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter. METHODS: A total of 32 visually normal subjects participated in the study. A standardized grid pattern was used for testing, which consisted of 28 points arranged concentrically in three circles that occupied an area of 11° (in diameter) within the central macula. Each subject participated in at least two tests. Parameters evaluated included: overall mean macular sensitivity for test 1 and 2, overall difference in mean macular sensitivity between tests, and the mean sensitivity for each circle. The relationship between sensitivity and age was also examined. RESULTS: The overall median sensitivity for test 1 was 16.8 decibels (dB) and for test 2 was 16.9 dB. The median sensitivities for test 1 and test 2 were not significantly different (P = 0.72). The mean intrasession sensitivity difference was 0.13 dB. The variability of the sensitivity difference between tests decreased as mean sensitivity increased. The sensitivity values averaged across the two tests for inner, middle, and outer circles ranged from 14.3 to 18.8 dB (median value of 16.9 dB), 13.8-18.3 dB (median value of 17.2 dB), and 11.3-18.3 dB (median value of 16.6 dB), respectively. Linear regression analysis showed a 0.5 dB sensitivity loss for each decade of life. CONCLUSION: We documented a narrow range of intrasession fluctuation using the OPKO/OTI microperimeter. The establishment of normative sensitivity values will facilitate monitoring the loss of macular visual function in patients with retinal disease.


Asunto(s)
Adaptación Ocular/fisiología , Luz , Mácula Lútea/fisiología , Oftalmoscopía/métodos , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Algoritmos , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Umbral Sensorial/fisiología , Campos Visuales/fisiología
18.
Artículo en Inglés | MEDLINE | ID: mdl-1370398

RESUMEN

Human cortical visual evoked potentials (VEPs) were retrieved in real time (without averaging). The stimuli were sinusoidal gratings whose contrast was temporally modulated about some mean value. Electrophysiologically determined contrast modulation thresholds were measured at standing contrast over the range from 2.5% to 50%, defining an increment threshold function. Increment threshold functions were obtained under two different spatio-temporal stimulus conditions identified as "sustained" (4 c/deg grating modulated at 1.5 Hz) and "transient" (1 c/deg grating modulated at 20 Hz). Under each of these conditions, threshold responses were retrieved at both the fundamental and second harmonic of the contrast modulation frequency. Under "sustained" conditions log increment threshold responses and the fundamental the second harmonic of the modulation frequency were similar to those at the fundamental except for a saturation effect (i.e., above a mean contrast of 25% there was little further reduction in modulation sensitivity). There was no contrast gain control under "transient" stimulus conditions. In other words, the same absolute amount of contrast change produced threshold responses for all mean levels up to 25%. This was true at both the fundamental and second harmonic of the modulation frequency. Stimulus differences produce striking differences in the electrophysiologically inferred increment threshold function for grating contrast, but fundamental and second harmonic evoked responses reflect processes with similar increment threshold behavior.


Asunto(s)
Sensibilidad de Contraste/fisiología , Potenciales Evocados Visuales/fisiología , Humanos , Estimulación Luminosa
19.
Am J Optom Physiol Opt ; 63(1): 1-6, 1986 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-3942182

RESUMEN

Temporal modulation transfer functions (MTF's) were recorded from the macula of nine normal subjects using focal electroretinography (FERG). An array of light emitting diodes (LED's) was used to experimentally manipulate stimulus temporal frequency, modulation depth, and mean luminance values. Two techniques were used to derive FERG modulation thresholds at several temporal frequencies: conventional averaging with extrapolation to a criterion amplitude, and a swept stimulus lock-in retrieval method. These two methods produced comparable results. The electrophysiologically derived MTF's were similar in shape to those obtained psychophysically. Six patients with retinal disease were also examined; all patients showed sensitivity losses which were most marked at the higher frequencies. Such losses tended to be greater in patients with poorer visual acuity.


Asunto(s)
Electrorretinografía/métodos , Psicofísica/métodos , Visión Ocular/fisiología , Adulto , Umbral Diferencial , Femenino , Humanos , Masculino , Estimulación Luminosa/métodos , Enfermedades de la Retina/fisiopatología
20.
Doc Ophthalmol ; 65(3): 307-18, 1987 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-3500024

RESUMEN

A patient with congenital stationary night blindness (CSNB) (Schubert-Bornschein type) transmitted as an autosomal recessive trait was studied with several tests of electrical function as well as a variety of psychophysical procedures. Comparison of the patient's present findings with those obtained 23 years earlier showed that while rod thresholds have remained the same, cone sensitivity has decreased. Subjective flicker thresholds obtained following a bleach were unchanged during the course of dark adaptation. The absence of rod-cone interaction, together with an absent scotopic b-wave, implies that the defect is in the mid-retinal layers. Further, the absence of oscillatory potentials in the photopic electroretinogram (ERG) suggests that the interplexiform cell may be implicated in some manner. The focal ERG of the CSNB patient showed normal amplitude and normal phase delays, supporting the idea that the focal ERG samples primarily cone photoreceptor activity.


Asunto(s)
Ceguera Nocturna/congénito , Células Fotorreceptoras/fisiopatología , Adulto , Adaptación a la Oscuridad , Electrorretinografía , Humanos , Masculino , Ceguera Nocturna/fisiopatología , Umbral Sensorial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA