1.
J Cardiovasc Electrophysiol ; 33(2): 154-159, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34953099

RESUMEN

BACKGROUND: Cardiac perforation during leadless pacemaker implantation is more likely to require intervention than perforation by a transvenous lead. This study reports the consequences of Micra pacemaker perforations and related device and operator use problems based on information the manufacturer has submitted to the Food and Drug Administration (FDA). METHODS: FDA's Manufacturer and User Facility Device Experience (MAUDE) database was searched for Micra perforations. Data extracted included deaths, major adverse clinical events (MACEs), and device and/or operator use problems. RESULTS: Between 2016 and July 2021, 563 perforations were reported within 30 days of implant and resulted in 150 deaths (27%), 499 cardiac tamponades (89%), 64 pericardial effusions (11%), and 146 patients (26%) required emergency surgery. Half of perforations were associated with 139 (25%) device problems, 78 (14%) operator use problems, and 62 (11%) combined device and operator use problems. Inadequate electrical measurements or difficult positioning were the most frequent device problems (n = 129); non-septal implants and perforation of other structures were the most frequent operator use problems (n = 69); a combined operator use and device problem resulted in 62 delivery system perforations. No device or operator use problem was identified for 282 perforations (50%), but they were associated with 78 deaths, 245 tamponades, and 57 emergency surgeries. CONCLUSION: The Micra perforations reported in MAUDE are often associated with death and major complications requiring emergency intervention. Device and use problems account for at least half of perforations. Studies are needed to identify who is at risk for a perforation and how MACE can be avoided or mitigated.


Asunto(s)
Taponamiento Cardíaco , Lesiones Cardíacas , Marcapaso Artificial , Taponamiento Cardíaco/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Humanos , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration
2.
Am Heart J ; 218: 128-132, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31806088

RESUMEN

New-onset left bundle branch block (N-LBBB) after transcatheter aortic valve replacement (TAVR) is a challenging clinical dilemma. In our single-center study, 60 out of 172 patients who underwent permanent pacemaker implantation (PPM) after TAVR had N-LBBB (34.9%). At a median follow-up duration of 357 days (IQR, 178; 560 days), two patients (3.5%) were completely pacemaker-dependent, and four others (7%) were partially dependent. Twelve patients (24%) recovered conduction in their left bundle at a median follow-up duration of 5 weeks (IQR, 4; 14 weeks). Due to the lack of clinical predictors of pacemaker dependency, active surveillance is warranted and may be an alternative to permanent pacemaker implantation.


Asunto(s)
Bloqueo de Rama/terapia , Marcapaso Artificial , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/etiología , Bloqueo de Rama/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Implantación de Prótesis/estadística & datos numéricos , Recuperación de la Función , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 30(10): 1860-1867, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31353679

RESUMEN

BACKGROUND: Ablation of persistent atrial fibrillation (AF) remains challenging. Identification and ablation of localized AF drivers may offer the possibility for improved outcomes. Ripple map is a novel software algorithm that may allow improved localization of possible AF drivers through the whole chamber graphical display of continuously recorded bipolar electrograms. The objective of this study was to determine whether regions of high-frequency Ripple activation (HFRA) observed on Ripple map provide useful ablation targets in patients with persistent AF. METHODS AND RESULTS: Consecutive patients underwent the first-time ablation of persistent AF (n = 162) using a standard stepwise (n = 105) or a Ripple map guided approach (n = 57). Ripple map guided patients underwent pulmonary vein antral isolation followed by ablation of HFRA sites. Acute termination of AF was observed in 91.2% of the Ripple-guided patients vs 52.4% in the stepwise approach, P < .0001. Following a single ablation procedure, after 18 months 98.2% of Ripple map guided patients were free of AF, compared with 81.4% of standard stepwise ablation (P = .005). Freedom from atrial tachycardia (54.4% Ripple map vs 52.4% standard, P = .9) or any atrial arrhythmia (52.6% Ripple map vs 39.0% standard, P = .10) did not differ between the two strategies. In a subset analysis (n = 30 of 56), Ripple map regions corresponded to sites with spatiotemporal dispersion in all atrial locations. No differences were observed in the rate of procedural complications. CONCLUSIONS: Ablation of HFRA sites identified with Ripple map resulted in a higher rate of acute termination and improved freedom from AF compared to a standard stepwise approach.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
4.
Am J Med Genet A ; 176(7): 1622-1626, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-30160835

RESUMEN

A novel autosomal-dominant in-frame deletion resulting in a nonsense mutation in the desmoplakin (DSP) gene was identified in association with biventricular arrhythmogenic cardiomyopathy across three generations of a large Caucasian family. Mutations that disrupt the function and structure of desmosomal proteins, including desmoplakin, have been extensively linked to familial arrhythmogenic right ventricular cardiomyopathy (ARVC). Analysis of data from 51 individuals demonstrated the previously undescribed variant p.Cys81Stop (c.243_251delCTTGATGCG) in DSP segregates with a pathogenic phenotype exhibiting variable penetrance and expressivity. The mutation's pathogenicity was first established due to two sudden cardiac deaths (SCDs), each with a biventricular cardiomyopathy identified on autopsy. Of the individuals who underwent genetic screening, 27 of 51 were heterozygous for the DSP mutation (29 total with two obligate carriers). Six of these were subsequently diagnosed with arrhythmogenic cardiomyopathy. An additional nine family members have a conduction disorder and/or myocardial structural changes characteristic of an evolving condition. Previous reports from both human patients and mouse studies proposed DSP mutations with a premature stop codon impart mild to no clinical symptoms. Loss of expression from the abnormal allele via the nonsense-mediated mRNA decay pathway has been implicated to explain these findings. We identified an autosomal-dominant DSP nonsense mutation in a large family that led to SCD and phenotypic expression of arrhythmogenic cardiomyopathy involving both ventricles. This evidence demonstrates the pathogenic significance of this type of desmosomal mutation and provides insight into potential clinical manifestations.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/genética , Codón sin Sentido , Muerte Súbita Cardíaca/patología , Desmoplaquinas/genética , Genes Dominantes , Predisposición Genética a la Enfermedad , Adulto , Displasia Ventricular Derecha Arritmogénica/patología , Femenino , Humanos , Masculino , Linaje , Pronóstico
5.
Pacing Clin Electrophysiol ; 41(4): 396-401, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29450893

RESUMEN

BACKGROUND: Limited medical options are available for rhythm control in patients with atrial fibrillation (AF) and hypertrophic cardiomyopathy (HCM). There are no published reports of dofetilide use in this population. METHODS: A retrospective chart review was conducted on 1,404 patients loaded on dofetilide for AF suppression at the Cleveland Clinic from 2008 to 2012, 25 of whom were found to have HCM. RESULTS: The HCM cohort was 32% female, 76% with persistent AF, mean age of 59 ± 10 years, and mean ejection fraction of 54 ± 9 %. Of the 25 patients, 21 were discharged on dofetilide, three discontinued during loading due to QTc prolongation, and one due to inefficacy. There were no adverse events during loading. Of those discharged on dofetilide, 11/21 (52%) were still on it at a median follow-up of 396 (198, 699) days at the time of the chart review. For those in whom it was discontinued, the median time on the drug was 301 (111, 738) days. Of the 10 patients who discontinued dofetilide during follow-up, six were due to inefficacy, one postablation, one postheart transplant, one due to death secondary to lung cancer, and one due to worsening edema. CONCLUSIONS: Dofetilide was well tolerated in this group of patients with AF and HCM and it facilitated management of AF in 21/25 (84%) patients. Further research is needed to assess the safety and efficacy of dofetilide in order to develop evidence-based guidelines for the pharmacological management of AF in this population.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Cardiomiopatía Hipertrófica/tratamiento farmacológico , Fenetilaminas/uso terapéutico , Sulfonamidas/uso terapéutico , Fibrilación Atrial/complicaciones , Cardiomiopatía Hipertrófica/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
7.
Heart Rhythm ; 21(2): 143-149, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37956776

RESUMEN

BACKGROUND: In 2022 and 2023, Medtronic recalled implantable defibrillators because they may deliver less than full-energy shocks. The 2022 problem truncates the second phase of the waveform (SCP-T2), resulting in ∼32-J shocks, and is mitigated by downloadable software. The 2023 malfunction truncates the first phase of the waveform, resulting in 0- to 12-J shocks due to a glassed feedthrough problem (GFT-T1) that might be avoided by programming B>AX shock polarity. OBJECTIVE: The purpose of this study was to assess the consequences of GFT-T1 and SCP-T2 shocks in the Food and Drug Administration's Manufacturers and User Facility Device Experience (MAUDE) database and to estimate the incidences of GFT-T1 and SCP-T2. METHODS: We analyzed MAUDE reports supplemented by Medtronic data; lead failures were excluded. The incidences of SCP-T2 and GFT-T1 were estimated using USA volumes for devices with glassed feedthroughs. RESULTS: One hundred thirty-two devices delivered truncated shocks: 27 (20.5%) were GFT-T1; 103 (78.0%) were SCP-T2; and 2 (1.5%) truncated both phases (BOTH-T1&2). Of 54 ventricular fibrillation (VF) patients, 21 (38.9%) were not defibrillated by truncated shocks: 8 (38.1%) received GFT-T1 shocks, 12 (57.1%) received SCP-T2 shocks, and 1 received a BOTH-T1&2 shock; 2 patients suffered unrelated deaths; 1 was externally rescued; 1 outcome was unknown; the others were defibrillated by subsequent shocks or terminated spontaneously. The majority of patients (79.1%) shocked for ventricular tachycardia (VT) were converted, primarily (94.1%) by SCP-T2 shocks. Estimated incidences of GFT-T1 and SCP-T2 were 0.0078%-0.0088% and 0.1062%-0.1110%. CONCLUSION: GFT-T1 and SCP-T2 shocks can result in failure to terminate VF/VT, but they may be preventable. Although the incidences of these truncated shocks are very low, heightened surveillance is warranted.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/métodos , Estudios Prospectivos , Fibrilación Ventricular/terapia , Arritmias Cardíacas
8.
Curr Opin Cardiol ; 28(3): 337-43, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23549236

RESUMEN

PURPOSE OF REVIEW: Prevention of ventricular arrhythmias and implantable cardioverter-defibrillator (ICD) therapies in patients with heart failure will be reviewed. RECENT FINDINGS: ICD utilization in patients with heart failure has resulted in significantly improved long-term survival. However, there is growing evidence that ICD shocks are associated with increased morbidity and mortality. As a result, there is increasing emphasis on the treatment strategies to avoid ICD therapies. Optimal heart failure management with medical as well as cardiac resynchronization therapy when indicated is an essential part of treatment; however, adjunctive measures may be necessary to suppress ventricular arrhythmias, prevent unnecessary shocks, and improve quality of life. SUMMARY: Device programming can help avoid ICD therapies by delaying time to detection, increasing detection rate cutoffs, and discriminating between supraventricular and ventricular arrhythmias. Still, as patients live longer with advanced stages of heart failure, there will be a need to suppress sustained ventricular arrhythmias that would otherwise require ICD therapy. Antiarrhythmic drugs offer a noninvasive option to help suppress ventricular arrhythmias. With more experience and better catheter mapping and ablation techniques, there is a movement toward an early invasive strategy for ventricular tachycardia management in patients with heart failure.


Asunto(s)
Antiarrítmicos/uso terapéutico , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/terapia , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/terapia , Ablación por Catéter , Muerte Súbita Cardíaca/prevención & control , Insuficiencia Cardíaca/complicaciones , Humanos , Taquicardia Ventricular/complicaciones , Fibrilación Ventricular/complicaciones
9.
Heart Rhythm ; 20(7): 970-975, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37211148

RESUMEN

BACKGROUND: The LifeVest® wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death in at-risk patients who are not candidates for an implantable defibrillator. The safety and efficacy of the WCD may be impacted by inappropriate shocks (IAS). OBJECTIVE: The purpose of this study was to assess the causes and clinical consequences of WCD IAS in survivors of IAS events. METHODS: The Food and Drug Administration's Manufacturers and User Facility Device Experience database was searched for IAS adverse events (AE) that were reported during 2021 and 2022. RESULTS: A total of 2568 IAS-AE were found (average number of IAS per event: 1.5 ± 1.9; range 1-48). IAS were caused by tachycardias (1255 [48.9%]), motion artifacts (840 [32.7%]), and oversensing (OS) of low-level electrical signals (473 [18.4%]) (P <.001). Tachycardias included atrial fibrillation (AF) (828 [32.2%]), supraventricular tachycardia (SVT) (333 [13.0%]), and nonsustained ventricular tachycardia/fibrillation (NSVT/VF) (87 [3.4%]). Activities responsible for motion-induced IAS included riding a motorcycle, lawnmower, or tractor (n = 128). In 19 patients, IAS induced sustained ventricular tachycardia or ventricular fibrillation that subsequently were terminated by appropriate WCD shocks. Thirty patients fell and suffered physical injuries. Conscious patients (n = 1905) did not use the response buttons to abort shocks (47.9%) or used them improperly (20.2%). IAS resulted in 1190 emergency room visits or hospitalizations, and 17.3% of patients (421/2440) discontinued the WCD after experiencing IAS, especially multiple IAS. CONCLUSIONS: The LifeVest WCD may deliver IAS caused by AF, SVT, NSVT/VF, motion artifacts, and oversensing of electrical signals. These shocks may be arrhythmogenic, result in injuries, precipitate WCD discontinuation, and consume medical resources. Improved WCD sensing, rhythm discrimination, and methods to abort IAS are needed.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Cardioversión Eléctrica/efectos adversos , Desfibriladores Implantables/efectos adversos , Fibrilación Ventricular , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Fibrilación Atrial/complicaciones , Taquicardia Supraventricular/complicaciones
10.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1333-1339, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37558289

RESUMEN

BACKGROUND: The wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death due to ventricular tachycardia (VT) or ventricular fibrillation (VF) but does not pace for post-shock asystole (PS-A) or bradycardia (PS-B;<50 beats/ min). OBJECTIVES: The purpose of this study was to assess PS-A and PS-B in patients dying out of hospital (OOH) while wearing a WCD. METHODS: The database of the U.S. Food and Drug Administration Manufacturers and User Facility Device Experience (MAUDE) was queried for manufacturers' reports of OOH deaths while patients were wearing a WCD. Excluded were patients who did not receive a shock or were initially shocked for asystole or during resuscitation. RESULTS: From January 2017 to March 2022, 313 patients received an initial WCD shock for VF (n = 150), VT (n = 90), and non-VF/VT rhythms (n = 73). PS-A occurred in 204 patients (65.2%), and PS-B occurred in 111 (35.5%); 85 (41.7%) PS-A patients also had PS-B. Most PS-A patients (n = 185; 90.7%) had an initial shocked rhythm of VF or VT, but 19 patients (9.3%) were initially inappropriately shocked for atrial fibrillation/supraventricular tachycardia (n = 7) and idioventricular (n = 8) or sinus (n = 4) rhythm. PS-A occurred after the first WCD shock in 118 (63.8%) and after the first, second, or third shocks in 159 patients (85.9%). Seven patients had post-shock heart block. Eight patients had permanent pacemakers; 1 became nonfunctional after 1 shock, and 7 showed noncapture and/or asystole after 1 to 4 shocks. CONCLUSIONS: Post-shock asystole appears to be common in patients who die OOH after being shocked by a WCD for VF or VT. PS-A also occurs after inappropriate WCD shocks for non-VF/VT rhythms. Implanted pacemakers may not prevent PS-A after a WCD shock. WCD backup pacing should be explored.


Asunto(s)
Fibrilación Atrial , Paro Cardíaco , Taquicardia Ventricular , Estados Unidos , Humanos , Cardioversión Eléctrica/efectos adversos , Paro Cardíaco/terapia , Fibrilación Ventricular , Desfibriladores , Hospitales
11.
J Interv Card Electrophysiol ; 65(1): 133-139, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35538270

RESUMEN

BACKGROUND: Electronic products, including the iPhone 12, Apple Watch Series 6, and 2nd Generation AirPods, contain magnets to facilitate wireless charging. Permanent magnets may affect CIED magnet mode features by causing pacemakers to pace asynchronously and defibrillators to suspend arrhythmia detection. This study determined if CIEDs are affected by static magnetic fields from commonly used portable electronics (PE) at any distance and intends to reinforce FDA recommendations concerning consumer PE which contain permanent magnets. METHODS: The maximum magnet field measurement was evaluated by a Gauss meter. The interaction between PE and CIEDs from Boston Scientific and Medtronic were tested ex vivo using a body torso model. The CIED was placed in physiologic saline, and the PE was placed at the surface and at increasing distances of 0.5, 1.0, and 1.5 cm. Interactions were recorded by assessment of magnet mode status. RESULTS: The iPhone 12 had almost three times the static magnetic field measured at the surface as the iPhone XR, but magnetic field strength decreased dramatically with increasing distance. At the surface of the model, PE triggered magnet mode in all CIEDs. The maximum interaction distance for all combinations of CIEDs and Apple products was 1.5 cm. CONCLUSIONS: The iPhone 12 produces a stronger static magnetic field than previous iPhone models. Magnets in PE tested will not interact with CIEDs when they are 15 cm from the implanted device. Since no interaction was observed beyond 1.5 cm, it is unlikely that magnet mode activation will occur during most daily activities.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Campos Electromagnéticos , Electrónica , Humanos , Campos Magnéticos
12.
Heart Rhythm O2 ; 3(6Part A): 665-672, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36589915

RESUMEN

Background: Persistent atrial fibrillation (AF) is a complex arrhythmia, and attaining freedom from AF with ablation has been challenging. Objectives: This study evaluated a novel CARTO software algorithm based on the CARTO Ripple map for AF termination and 18-month freedom from AF. Methods: Consecutive patients who underwent first-time ablation for persistent AF were included. A high-density Ripple map was created using a Pentaray catheter. Following PVI, ablation was performed at locations with rapid Ripple activations, a protocol previously described by us. Patients were followed for 18 months to assess rhythm outcomes. A retrospective analysis was performed using the CARTO Ripple frequency software algorithm. The Ripple frequency algorithm quantifies amplitude changes in the bipolar electrogram. Results: A total of 115 AF maps were analyzed from 84 patients (mean age 65.9 years, 63.1% men). The top quartile of Ripple frequency corresponded to a visual reference with 96.7% sensitivity and 91.1% specificity. AF terminated during ablation in 88.1% of patients: pulmonary vein antrum alone (14.9%) or pulmonary vein plus nonantral sites (85.1%). The top quartile of Ripple frequency was present in nonantral areas associated with AF termination with 90.2% sensitivity and 86.5% specificity. After 14.0 ± 6.5 months and 1.2 ± 0.4 ablations, 78 (92.9%) of 84 patients were free of AF, and 79.8% were free of any atrial arrhythmia. Conclusion: A novel algorithm for automated analysis of CARTO Ripple frequency demonstrated good sensitivity and specificity for detecting atrial regions in persistent AF in which ablation is associated with frequent AF termination and freedom from AF during follow-up.

13.
Heart Rhythm ; 18(7): 1132-1139, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33713856

RESUMEN

BACKGROUND: Leadless intracardiac pacemakers were developed to avoid the complications of transvenous pacing systems. The Medtronic Micra™ transcatheter pacemaker is one such system. We found an unexpected number of major adverse clinical events (MACE) in the Food and Drug Administration's Manufacturers and User Facility Device Experience (MAUDE) database associated with Micra implantation. OBJECTIVE: The purpose of this study was to describe these MACE and compare them to implant procedure MACE in MAUDE for Medtronic CapSureFix™ active-fixation transvenous pacing leads. METHODS: During January 2021, we queried the MAUDE database for reports of MACE for Micra pacemakers and CapSureFix leads using the simple search terms "death," "tamponade," and "perforation." Reports from 2016-2020 were included. RESULTS: The search identified 363 MACE for Micra and 960 MACE for CapSureFix leads, including 96 Micra deaths (26.4%) vs 23 CapSureFix deaths (2.4%) (P <.001); 287 Micra tamponades (79.1%) vs 225 tamponades for CapSureFix (23.4%) (P <.001); and 99 rescue thoracotomies for Micra (27.3%) vs 50 rescue thoracotomies for CapSureFix (5.2%) (P <.001). More Micra patients required cardiopulmonary resuscitation (21.8% vs 1.1%) and suffered hypotension or shock (22.0% vs 5.8%) than CapSureFix recipients (P <.001). Micra patients were more likely to survive a myocardial perforation or tear if they had surgical repair (P = .014). CONCLUSION: Micra leadless pacemaker implantation may be complicated by myocardial and vascular perforations and tears that result in cardiac tamponade and death. We estimate the incidence is low (<1%). Rescue surgery to repair perforations may be lifesaving. MACE are significantly less for implantation of CapSureFix transvenous ventricular pacing leads.


Asunto(s)
Arritmias Cardíacas/terapia , Taponamiento Cardíaco/etiología , Marcapaso Artificial/efectos adversos , Diseño de Equipo , Estudios de Seguimiento , Humanos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
14.
J Interv Card Electrophysiol ; 62(3): 507-518, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33387130

RESUMEN

PURPOSE: We hypothesized that data in manufacturers' product performance reports (PPRs) can provide clinically valuable ICD and cardiac resynchronization defibrillator (CRT-D) reliability and longevity information. METHODS: Data were obtained from 2019 PPRs. Kaplan-Meier (K-M) probabilities of freedom from malfunction, normal battery depletion (NBD), and NBD + malfunction were calculated for ICD and CRT-D pulse generators (PGs) with LiMnO2 or LiSVO/CFx batteries marketed in the USA from 2010 to 2019 and compared using the log-rank test. Malfunctions (MAL) included PGs that were found outside specifications. RESULTS: Study population included 1,149,803 ICD and CRT-D PGs: Abbott (ABT; 35.1%), Biotronik (BIO; 4.6%), Boston Scientific (BSC; 23.5%), and Medtronic (MDT; 36.9%). Significant differences in reliability (p < 0.001), defined by freedom from MAL, were found between manufacturers; the majority of 6808 MAL occurred in ABT devices (n = 4045; 59.4%), followed by BSC (n = 2384; 35.0%), MDT (n = 338;5.0%), and BIO (n = 41; 0.6%). Battery failure (n = 890; 57.9%) was the most common cause of MAL compromising therapy; analysis of unique ABT battery MAL-indicated problem appeared a year prior to advisory. Significant differences (p < 0.001) in battery longevity, as defined by freedom from NBD, were found between manufacturers. Overall performance (freedom from NBD + MAL) favored BSC for CRT-D PGs and MDT and BIO for ICDs. BSC subcutaneous ICD reliability was inferior to its transvenous ICD (p < 0.001). CONCLUSION: PPRs contain valuable data that can be aggregated and analyzed to inform physicians. Differences in product reliability exist between manufacturers. Battery longevity has improved, but MAL have significantly impacted performance. PPR data may be useful for assessing product problems and new technology.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Factores de Tiempo
15.
JACC Case Rep ; 3(15): 1667-1673, 2021 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-34766015

RESUMEN

Patients with familial arrhythmogenic cardiomyopathy typically present with ventricular arrhythmias or progressive heart failure. This paper characterizes a rare presentation of an underlying genetic cardiomyopathy with clinical manifestations mimicking an acute myocardial infarction in 2 siblings, each with the same mutation in the desmoplakin (DSP) gene. (Level of Difficulty: Advanced.).

16.
J Interv Card Electrophysiol ; 58(3): 253-259, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31853803

RESUMEN

PURPOSE: We have reported the calcification of Endotak defibrillation leads that required replacement. The aim of this study was to assess calcified Endotak Reliance leads in the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database and compare them to calcified Sprint Fidelis, Sprint Quattro Secure, Riata, and Durata leads in MAUDE. METHODS: We searched the MAUDE database from 2008 to 2019 for defibrillation lead calcification using the terms "calcium," "calcification," and "calcified". Included were explanted leads whose manufacturers found calcium on the shocking and/or pacing electrode. RESULTS: The MAUDE search identified 113 calcified defibrillation leads that qualified for the study, including 109 Endotak Reliance leads, 1 Sprint Quattro Secure lead, 2 Durata leads, 1 Riata ST lead, and no Sprint Fidelis lead. The sign of calcification was a gradual increase in shocking or pacing impedance. Average implant time was 7.4 ± 3.1 (range: 1.3-16.5) years. Only Endotak Reliance leads had shocking coil calcification (n = 72; 66.0%) and five (6.9%) of these failed defibrillation threshold (DFT) testing. Distal pacing electrode calcification affected 55 (50.4%) Endotak Reliance leads. The four other leads had pacing ring electrode calcification only. CONCLUSION: Endotak Reliance defibrillation leads appear prone to shocking coil and/or distal pacing electrode calcification. High impedances may compromise defibrillation and pacing therapy. Patients who have these leads should be monitored; those exhibiting high shocking impedances should be considered for DFT testing. Lead replacement should be considered for pacemaker-dependent patients whose leads exhibit progressively high impedances.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Impedancia Eléctrica , Humanos , Estados Unidos , United States Food and Drug Administration
17.
JAMA Intern Med ; 180(2): 198-205, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31860011

RESUMEN

Importance: Timely and complete disclosure of medical device defects is necessary to manage patient care safely and effectively. Objectives: To determine if the manufacturer's recommendations following the recall of a medical device were timely and complete, the follow-up information and data provided to patients and physicians were adequate for managing patient care, and the actions taken by the US Food and Drug Administration (FDA) regarding the recall were appropriate. Design, Setting, and Participants: This single-center retrospective case series included 90 of 448 patients who were implanted with a cardiac resynchronization therapy pacemaker at the Minneapolis Heart Institute from May 2003 through January 2011; this pacemaker was recalled in November 2015. In addition, returned product reports submitted by the manufacturer to the FDA via the Manufacturer and User Facility Device Experience (MAUDE) database from January 2008 through December 2018 were analyzed. Main Outcomes and Measures: Clinical outcomes were serious adverse clinical events that occurred before and after the November 2015 recall notifying physicians and patients that the device's battery could fail unexpectedly because of high internal impedance. Technical outcomes were signs and causes of failure. Results: Five of 90 patients observed during 2015 experienced syncope when their pacemakers stopped pacing owing to battery or wire connection defects prior to the recall. Of the 90 patients, 37 (41%) were men, and the median (interquartile range) age at implantation was 71.3 (66.1-78.2) years. Analysis of the MAUDE data revealed that battery failures prior to the recall were associated with serious adverse events that included 1 death, 1 cardiac arrest, 5 syncopal attacks, and 6 heart failure exacerbations; 3 additional prerecall syncopal events were caused by wire connection defects. The manufacturer and the FDA were aware of the battery and wire connection defects for 19 months before issuing the recall, yet the wire connection problem was not included in the advisory and physicians were not informed that interrogating the pacemaker could result in loss of pacing. The FDA classified the recall as class II rather than the more critical class I. Conclusions and Relevance: This case series study of patients implanted with a defective pacemaker found that the pacemaker recall was delayed and that subsequent communications did not include all critical information needed for safe and effective patient care. These findings should prompt reforms in how the medical device industry and the FDA manage future medical device recalls.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Revelación , Falla de Equipo , Insuficiencia Cardíaca/terapia , Difusión de la Información , Recall de Suministro Médico , Anciano , Progresión de la Enfermedad , Femenino , Paro Cardíaco , Humanos , Masculino , Mortalidad , Estudios Retrospectivos , Síncope/etiología , Factores de Tiempo , Estados Unidos , United States Food and Drug Administration
18.
Cardiovasc Revasc Med ; 21(10): 1299-1304, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33246556

RESUMEN

BACKGROUND: The impact of new-onset persistent left bundle branch block (LBBB) after transcatheter aortic valve replacement (TAVR) on all-cause mortality has been controversial. METHODS: We conducted a systematic review and meta-analysis of eleven studies (7398 patients) comparing the short- and long- outcomes in patients who had new-onset LBBB after TAVR vs. those who did not. RESULTS: During a mean follow-up of 20.5±14months, patients who had new-onset persistent LBBB after TAVR had a higher incidence of all-cause mortality (29.7% vs. 23.6%; OR 1.28 (1.04-1.58), p=0.02), rehospitalization for heart failure (HF) (19.5% vs. 17.3%; OR 1.4 (1.13-1.73), p=0.002), and permanent pacemaker implantation (PPMi) (19.7% vs. 7.1%; OR 2.4 (1.64-3.52), p<0.001) compared with those who did not. Five studies (4180 patients) reported adjusted hazard ratios (HR) for all-cause mortality; new LBBB remained associated with a higher risk of mortality (adjusted HR 1.43 (1.08-1.9), p<0.01, I2=81%). CONCLUSION: Post-TAVR persistent LBBB is associated with higher PPMi, HF hospitalizations, and all-cause mortality. While efforts to identify patients who need post-procedural PPMi are warranted, more studies are required to evaluate the best follow-up and treatment strategies, including the type of pacing device if required, to improve long-term outcomes in these patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama , Insuficiencia Cardíaca , Humanos , Factores de Riesgo , Resultado del Tratamiento
20.
Heart Rhythm ; 16(8): 1215-1222, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30772531

RESUMEN

BACKGROUND: Internal insulation breaches (IBR) may result in implantable cardioverter-defibrillator lead failure and adverse clinical events. Concerns exist that the Durata lead may be prone to IBR. OBJECTIVE: The goals of this study were to assess Durata failures in the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database and compare them to failures in MAUDE for Endotak Reliance and Sprint Quattro Secure (QS) leads. METHODS: We searched the MAUDE database from 2008 to 2018 for IBR and other failure modes. Included were explanted leads whose manufacturers found an insulation or conductor defect not caused by extrinsic factors. RESULTS: The MAUDE search found 1011 qualifying leads. The cause of failure differed among leads (P < .001). The primary cause of Durata failure was IBR (293 of 316 leads [93%]), with IBR accounting for 47% (137 of 293); few QS (9 of 523 [1.7%]) and no Endotak Reliance leads failed because of IBR (P < .001). Durata IBR were responsible for 11 failures to treat ventricular tachycardia/ventricular fibrillation, and all were caused by high-voltage (HV) shorts between the proximal superior vena cava coil and a distal right ventricular coil cable (n = 10) or sensing conductor (n = 1); low values of HV impedance were found in these leads during defibrillation threshold testing (n = 3), after a shock or aborted shock (n = 7), and by an alert (n = 1). Inappropriate therapy was caused by 51 Durata IBR, but no QS IBR. CONCLUSION: Durata implantable cardioverter-defibrillator leads are susceptible to IBR that may result in failure to treat ventricular tachycardia/ventricular fibrillation or inappropriate therapy; such failures may occur without forewarning. HV testing of Durata leads may be indicated during pulse generator replacement or when an insulation defect is suspected.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Sistema de Conducción Cardíaco/fisiopatología , Arritmias Cardíacas/fisiopatología , Diseño de Equipo , Falla de Equipo , Femenino , Humanos , Masculino , Estudios Retrospectivos