RESUMEN
Because only a minority of patients with nonalcoholic fatty liver disease (NAFLD) have advanced fibrosis and would eventually develop liver-related complications, current guidelines recommend initial assessment with noninvasive tests of fibrosis.1-3 Most previous studies focused on overweight and obese patients. Despite a strong association between obesity and NAFLD, 3%-30% of people with relatively normal body mass index (BMI) may still have NAFLD.4,5 Hence, this study aims to evaluate the performance of the common noninvasive tests in non-obese (BMI <25 kg/m2) and obese (BMI ≥25 kg/m2) NAFLD patients.
Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Índice de Masa Corporal , Humanos , Cirrosis Hepática/complicaciones , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Obesidad/complicaciones , SobrepesoRESUMEN
OBJECTIVE: The latest model of vibration-controlled transient elastography (VCTE) automatically selects M or XL probe according to patients' body built. We aim to test the application of a unified interpretation of VCTE results with probes appropriate for the body mass index (BMI) and hypothesise that this approach is not affected by hepatic steatosis. DESIGN: We prospectively recruited 496 patients with non-alcoholic fatty liver disease who underwent VCTE by both M and XL probes within 1 week before liver biopsy. RESULTS: 391 (78.8%) and 433 (87.3%) patients had reliable liver stiffness measurement (LSM) (10 successful acquisitions and IQR:median ratio ≤0.30) by M and XL probes, respectively (p<0.001). The area under the receiver operating characteristic curves was similar between the two probes (0.75-0.88 for F2-4, 0.83-0.91 for F4). When used in the same patient, LSM by XL probe was lower than that by M probe (mean difference 2.3 kPa). In contrast, patients with BMI ≥30 kg/m2 had higher LSM regardless of the probe used. When M and XL probes were used in patients with BMI <30 and ≥30 kg/m2, respectively, they yielded nearly identical median LSM at each fibrosis stage and similar diagnostic performance. Severe steatosis did not increase LSM or the rate of false-positive diagnosis by XL probe. CONCLUSION: High BMI but not severe steatosis increases LSM. The same LSM cut-offs can be used without further adjustment for steatosis when M and XL probes are used according to the appropriate BMI.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Adulto , Anciano , Índice de Masa Corporal , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND & AIMS: Virtual Touch Quantification (VTQ) evaluates liver fibrosis in patients with chronic liver diseases by measuring shear wave speed in the liver. We aimed to determine the reliability criteria of VTQ examination. METHODS: We performed a prospective study of 1094 patients with chronic liver disease from November 2009 through October 2016 at Angers University Hospital, and between April 2010 and May 2015 at Bordeaux University Hospital, in France. All patients underwent liver biopsy analysis (reference standard), and VTQ examination was made by experienced operators on the same day, or no more than 3 months before or afterward. Advanced liver fibrosis was defined as fibrosis stage F ≥ 3 according to the scoring system of the Nonalcoholic Steatohepatitis Clinical Research Network, or fibrosis stage F ≥ 2 according to the Metavir scoring system. The diagnostic accuracy of VTQ in detection of advanced fibrosis or cirrhosis was assessed using the area under the receiver operating characteristic (AUROC) and the rate of correctly classiï¬ed patients. Reliability criteria were defined from the intrinsic characteristics of VTQ examination, which were shown to influence the diagnostic accuracy. RESULTS: VTQ identified patients with advanced fibrosis with an AUROC of 0.773 ± 0.014 and correctly classified 72.0% of patients using a diagnostic cut-off value of 1.37 m/s. VTQ identified patients with cirrhosis with an AUROC value of 0.839 ± 0.014 and correctly classified 78.4% of patients using a cut-off value of 1.87 m/s. The reliability of VTQ decreased with an increasing ratio of interquartile range/median (IQR/M) in patients with intermediate-high VTQ results. We defined 3 reliability categories for VTQ: unreliable (IQR/M ≥0.35 with VTQ result ≥1.37 m/s), reliable (IQR/M ≥0.35 with VTQ result <1.37 m/s or IQR/M 0.15-0.34), and very reliable (IQR/M <0.15). For advanced fibrosis, VTQ correctly classified 57.8% of patients in the unreliable group, 73.7% of patients in the reliable group, and 80.9% of patients in the very reliable group (P < .001); for cirrhosis, these values were 50.0%, 83.4%, and 92.6%, respectively (P < .001). Of the VTQ examinations made, 21.4% were unreliable, 55.0% were reliable, and 23.6% were very reliable. The skin-liver capsule distance was independently associated with an unreliable VTQ examination, which occurred in 52.7% of patients with a distance of 30 mm or more. CONCLUSIONS: In a study to determine the reliability of VTQ findings, compared with results from biopsy analysis, we assigned VTQ examinations to 3 categories (unreliable, reliable, and very reliable). VTQ examinations with IQR/M ≥0.35 and ≥1.37 m/s had very low diagnostic accuracy. Our reliability criteria for liver fibrosis assessment with VTQ will help physicians to accurately evaluate the severity of chronic liver diseases and monitor their progression.
Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROCRESUMEN
BACKGROUND & AIMS: Vedolizumab is used to treat patients with ulcerative colitis (UC), although there is a delay before it is effective. Induction therapy with a calcineurin inhibitor (cyclosporine or tacrolimus) in combination with vedolizumab as maintenance therapy could be an option for patients with an active steroid-refractory UC. We assessed the efficacy and safety of this combination. METHODS: We performed a retrospective observational study, collecting data from 12 referral centers in France that were included in the Groupe d'Etude Thérapeutique des Affections Inflammatoires du tube Digestif. We collected information on 39 patients with an active steroid-refractory UC (31 with active severe UC and 36 failed by treatment with a tumor necrosis factor antagonist) who received a calcineurin inhibitor as induction therapy along with vedolizumab as maintenance therapy. Inclusion date was the first vedolizumab infusion. The outcomes were survival without colectomy, survival without vedolizumab discontinuation, and safety. RESULTS: After a median follow-up period of 11 months, 11 patients (28%) underwent colectomy. At 12 months, 68% of the patients survived without colectomy (95% CI, 53%-84%) and 44% survived without vedolizumab discontinuation (95% CI, 27%-61%). No deaths occurred and 4 severe adverse events were observed. CONCLUSIONS: In a retrospective analysis of 39 patients with an active steroid-refractory UC (most refractory to a tumor necrosis factor antagonist), we found that initial treatment with a calcineurin inhibitor in combination with vedolizumab allowed more than two thirds of patients to avoid colectomy. Further studies are needed to assess the safety of this strategy.
Asunto(s)
Anticuerpos Monoclonales Humanizados/administración & dosificación , Inhibidores de la Calcineurina/administración & dosificación , Colitis Ulcerosa/tratamiento farmacológico , Quimioterapia Combinada/métodos , Fármacos Gastrointestinales/administración & dosificación , Quimioterapia de Inducción/métodos , Adolescente , Adulto , Anciano , Anticuerpos Monoclonales Humanizados/efectos adversos , Inhibidores de la Calcineurina/efectos adversos , Quimioterapia Combinada/efectos adversos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/patología , Femenino , Francia , Fármacos Gastrointestinales/efectos adversos , Humanos , Quimioterapia de Inducción/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto JovenRESUMEN
INTRODUCTION: FibroScan's M and XL probes give significantly different results, which could lead to misevaluation of liver fibrosis if the correct probe is not chosen. According to the manufacturer, the M probe should be used when the skin-liver capsule distance (SCD) is <25 mm, and the XL probe should be used when SCD is ≥25 mm. We aimed at validating this recommendation and defining the conditions of use for FibroScan probes in clinical practice. METHODS: Four hundred thirty-nine patients with biopsy-proven chronic liver disease were included. Of them, 382 had successful examinations with both M and XL probes. Advanced fibrosis was defined as Nonalcoholic Steatohepatitis Clinical Research Network (NASH CRN) F ≥3 or Metavir F ≥2. RESULTS: In a same patient, XL probe results were significantly lower than M probe results: 7.9 (5.6-11.7) vs 9.5 (6.7-14.6) kPa, respectively (P < 0.001). After matching for age, sex, liver fibrosis, and serum transaminases, M probe results in patients with SCD <25 mm and XL probe results in those with SCD ≥25 mm did not significantly differ: 8.8 (6.0-12.0) vs 9.1 (6.7-12.8) kPa, respectively (P = 0.175). Of note, 81.4% of patients with body mass index (BMI) <32 kg/m had SCD <25 mm, and 77.7% of patients with BMI ≥32 kg/m had SCD ≥25 mm. A practical algorithm using BMI first and then the FibroScan Automatic Probe Selection tool was proposed to help physicians accurately choose which probe to use in clinical practice. CONCLUSIONS: There is no significant difference in results between M and XL probes when they are used in the right conditions. In clinical practice, the probe should be selected according to the BMI and the Automatic Probe Selection tool.