Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Environ Monit Assess ; 194(2): 51, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34985601

RESUMEN

Stormwater harvesting and reuse in the urban environment is emerging as an alternative water source, despite human pathogens in the stormwater may represent a hazard to public health. This study presents the results of 1-year monitoring to evaluate the quality of stormwater obtained in a high-income neighborhood in Rio de Janeiro for a set of microbiological parameters as total coliforms, Escherichia coli (E. coli), human adenovirus (HAdV), human JC polyomavirus (JCPyV), Group A rotavirus (RVA), and norovirus GI and GII. Forty-eight stormwater samples obtained from two multiplex units presented total coliforms and E. coli in 91.7% (n = 44) and 58.3% (n = 28) of samples, while HAdV and JCPyV were detected in 20.8% (n = 10) and 12.5% (n = 6), respectively. Viral quantification ranged from 103 to 104 genomic copies/liter (GC/L) for HAdV and from 101 to 104 GC/L for JCPyV. Neither RVA nor norovirus GI and GII was detected. Fifteen out of sixteen (93.8%) samples containing viruses were compliant as per fecal indicator bacteria (FIB) according to Brazilian standards for rainwater reuse and US EPA Guidelines for Water Reuse, suggesting that viruses monitoring should complement the study of bacterial indicators.


Asunto(s)
Monitoreo del Ambiente , Microbiología del Agua , Adenovirus Humanos , Brasil , Escherichia coli , Humanos
2.
Respiration ; 100(2): 135-144, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33477141

RESUMEN

BACKGROUND: According to guidelines, it is possible to biopsy lung tumors "immediately adjacent to the esophagus" with EUS-B-FNA. However, it is unknown what "immediately adjacent" exactly means. OBJECTIVE: to investigate the possibility of achieving EUS-B-FNA biopsies from a lung tumor depending on the distance from the esophagus and to establish the maximal allowable distance between the tumor and the esophagus. METHODS: In a prospective observational study, we included patients with a lung tumor located maximum 6 cm from the esophagus and indication of EUS-B-FNA from the tumor. The tumors were of different sizes. In a plot presenting the tumor size-distance relationship in cases with (biopsy) versus without (non-biopsy) successful EUS-B-FNA, a separation line representing the threshold between the groups were identified and a biopsy-index equation established. The maximal tumor-size corrected distance (TSCD) was calculated using the residuals to the separation line. RESULTS: In total, 70 patients were included. EUS-B-FNA from the lung tumor was possible in 46 patients. All tumors with a distance from the esophagus below 19 mm could be biopsied. The maximal allowable esophagus-tumor distance depended on tumor size. From the separation line, a biopsy-index equation was established with the sensitivity of 93.5%, a specificity of 100%, and total accuracy of 95.7%. The TSCD was 31 mm (sensitivity: 95.7%, specificity 75.0%, and accuracy: 88.6%). CONCLUSION: We established a biopsy-index equation to predict the achievability of a lung tumor using EUS-B-FNA depending on distance to esophagus and tumor size. A general maximal TSCD was 31 mm.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Esófago , Neoplasias Pulmonares/patología , Pulmón/patología , Anciano , Esófago/anatomía & histología , Esófago/diagnóstico por imagen , Femenino , Humanos , Pulmón/anatomía & histología , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía
3.
Respiration ; 98(5): 428-433, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31563907

RESUMEN

BACKGROUND: In patients with suspected or proven lung cancer, assessment of regional nodal and distant metastases is key before treatment planning. By introducing the endobronchial ultrasound (EBUS)-guided scope into the esophagus and stomach (EUS-B), liver lesions and celiac nodes can be visualized. To date, the utility of EUS-B in diagnosing liver lesions and retroperitoneal lymph nodes is unknown. OBJECTIVES: To assess the feasibility, safety, and diagnostic yield of sampling of liver lesions and retroperitoneal nodes by EUS-B fine-needle aspiration (FNA) in a lung cancer staging setting. METHOD: Consecutive patients suspected of lung cancer in 2 Danish centers between 1 January 2015 and 31 December 2017 were included retrospectively when a lesion in the liver or a retroperitoneal lymph node was visualized and biopsied with EUS-B-FNA. RESULTS: 23 left liver lobe lesions and 19 retroperitoneal lymph nodes were sampled by EUS-B-FNA. Sensitivity and diagnostic yield of sampled liver lesions were 86 and 83%, respectively. In 19/23 patients, there was a cytopathological diagnosis of malignancy. Sensitivity and diagnostic yield from retroperitoneal lymph node samples were 83 and 63%, respectively. In 10/19 patients, the diagnosis was malignancy. No complications were observed. CONCLUSION: EUS-B-FNA enables safe sampling of left liver lobe lesions and retroperitoneal lymph nodes. EUS-B should be considered as a minimally invasive technique to provide tissue proof of distant metastases lung cancer patients.


Asunto(s)
Broncoscopía/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Pulmonares/patología , Neoplasias Retroperitoneales/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
4.
Respiration ; 97(4): 277-283, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30253411

RESUMEN

BACKGROUND: Diagnosing centrally located lung tumors without endobronchial abnormalities and not located near the major airways is a diagnostic challenge. Tumors near or adjacent to the esophagus can be aspirated and detected with esophageal ultrasound (EUS) using gastrointestinal endoscopes. OBJECTIVE: To assess the feasibility and diagnostic yield of endoscopic ultrasound with bronchoscope-guided fine needle aspiration (EUS-B-FNA) in paraesophageally located lung tumors and its added value to bronchoscopy and endobronchial ultrasound (EBUS). METHODS: Retrospective, multicenter international study (from January 1, 2015 until January 1, 2018) of patients with suspected lung cancer, undergoing bronchoscopy, EBUS, and endoscopic ultrasound bronchoscopy (EUS-B) in one session by a single operator (pulmonologist), in whom the primary lung tumor was detected and aspirated by EUS-B. In the absence of malignancy following endoscopy, transthoracic ultrasound needle aspiration, clinical and radiological follow-up of at least 6 months was performed. The yield and sensitivity of EUS-B-FNA and its added value to bronchoscopy and EBUS was assessed. RESULTS: 58 patients were identified with the following diagnosis: non-small-cell lung cancer (n = 43), small-cell lung cancer (n = 6), mesothelioma (n = 2), metastasis (n = 1), nonmalignant (n = 6). The yield and sensitivity of EUS-B-FNA for detecting lung cancer was 90%. In 26 patients (45%), the intrapulmonary tumor was exclusively detected by EUS-B. Adding EUS-B to conventional bronchoscopy and EBUS increased the diagnostic yield for diagnosing lung cancer in para-esophageally located lung tumors from 51 to 91%. No EUS-B-related complications were observed. CONCLUSION: EUS-B-FNA is a feasible and safe technique for diagnosing centrally located intrapulmonary tumors that are located near or adjacent to the esophagus. EUS-B should be considered in the same endoscopy session following nondiagnostic bronchoscopy and EBUS.


Asunto(s)
Adenocarcinoma/diagnóstico , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pulmonares/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
Appl Microbiol Biotechnol ; 101(3): 1253-1266, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27838840

RESUMEN

In this study, we investigated the use of Illumina high-throughput sequencing of 16S ribosomal RNA (rRNA) amplicons to explore microbial diversity and community structure in raw and secondary treated wastewater (WW) samples from four municipal wastewater treatment plants (WWTPs A-D) across Australia. Sequence reads were analyzed to determine the abundance and diversity of bacterial communities in raw and secondary treated WW samples across the four WWTPs. In addition, sequence reads were also characterized to phenotypic features and to estimate the abundance of potential pathogenic bacterial genera and antibiotic-resistant genes in total bacterial communities. The mean coverage, Shannon diversity index, observed richness (S obs), and abundance-based coverage estimate (ACE) of richness for raw and secondary treated WW samples did not differ significantly (P > 0.05) among the four WWTPs examined. Generally, raw and secondary treated WW samples were dominated by members of the genera Pseudomonas, Arcobacter, and Bacteroides. Evaluation of source contributions to secondary treated WW, done using SourceTracker, revealed that 8.80-61.4% of the bacterial communities in secondary treated WW samples were attributed to raw WW. Twenty-five bacterial genera were classified as containing potential bacterial pathogens. The abundance of potentially pathogenic genera in raw WW samples was higher than that found in secondary treated WW samples. Among the pathogenic genera identified, Pseudomonas and Arcobacter had the greatest percentage of the sequence reads. The abundances of antibiotic resistance genes were generally low (<0.5%), except for genes encoding ABC transporters, which accounted for approximately 3% of inferred genes. These findings provided a comprehensive profile of bacterial communities, including potential bacterial pathogens and antibiotic-resistant genes, in raw and secondary treated WW samples from four WWTPs across Australia and demonstrated that Illumina high-throughput sequencing can be an alternative approach for monitoring WW quality in order to protect environmental and human health.


Asunto(s)
Bacterias/genética , Bacterias/aislamiento & purificación , Aguas Residuales/microbiología , Purificación del Agua , Arcobacter/genética , Arcobacter/aislamiento & purificación , Australia , Bacterias/clasificación , Bacterias/patogenicidad , Bacteroides/genética , Bacteroides/aislamiento & purificación , Farmacorresistencia Microbiana/genética , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Consorcios Microbianos/genética , Pseudomonas/genética , Pseudomonas/aislamiento & purificación , ARN Ribosómico 16S , Factores de Riesgo , Análisis de Secuencia de ADN , Eliminación de Residuos Líquidos
6.
J Environ Sci (China) ; 57: 231-237, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28647243

RESUMEN

A quantitative PCR (qPCR) assay was used to quantify Ancylostoma caninum ova in wastewater and sludge samples. We estimated the average gene copy numbers for a single ovum using a mixed population of ova. The average gene copy numbers derived from the mixed population were used to estimate numbers of hookworm ova in A. caninum seeded and unseeded wastewater and sludge samples. The newly developed qPCR assay estimated an average of 3.7×103 gene copies per ovum, which was then validated by seeding known numbers of hookworm ova into treated wastewater. The qPCR estimated an average of (1.1±0.1), (8.6±2.9) and (67.3±10.4) ova for treated wastewater that was seeded with (1±0), (10±2) and (100±21) ova, respectively. The further application of the qPCR assay for the quantification of A. caninum ova was determined by seeding a known numbers of ova into the wastewater matrices. The qPCR results indicated that 50%, 90% and 67% of treated wastewater (1L), raw wastewater (1L) and sludge (~4g) samples had variable numbers of A. caninum gene copies. After conversion of the qPCR estimated gene copy numbers to ova for treated wastewater, raw wastewater, and sludge samples, had an average of 0.02, 1.24 and 67 ova, respectively. The result of this study indicated that qPCR can be used for the quantification of hookworm ova from wastewater and sludge samples; however, caution is advised in interpreting qPCR generated data for health risk assessment.


Asunto(s)
Ancylostoma , Monitoreo del Ambiente/métodos , Óvulo , Aguas Residuales/parasitología , Animales , Reacción en Cadena en Tiempo Real de la Polimerasa
7.
J Environ Qual ; 44(5): 1392-401, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26436257

RESUMEN

The transport of human adenovirus, nanoparticles, and PRD1 and MS2 bacteriophages was tested in fine granular limestone aquifer material taken from a borehole at a managed aquifer recharge site in Adelaide, South Australia. Comparison of transport and removal of virus surrogates with the pathogenic virus is necessary to understand the differences between the virus and surrogate. Because experiments using pathogenic viruses cannot be done in the field, laboratory tests using flow-through soil columns were used. Results show that PRD1 is the most appropriate surrogate for adenovirus in an aquifer dominated by calcite material but not under high ionic strength or high pH conditions. It was also found that straining due to size and the charge of the colloid were not dominant removal mechanisms in this system. Implications of this study indicate that a certain surrogate may not represent a specific pathogen solely based on similar size, morphology, and/or surface charge. Moreover, if a particular surrogate is representative of a pathogen in one aquifer system, it may not be the most appropriate surrogate in another porous media system. This was apparent in the inferior performance of MS2 as a surrogate, which is commonly used in virus transport studies.

8.
Heliyon ; 10(5): e27384, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38486766

RESUMEN

Environmental oligotrophic bacteria are suspected to be highly relevant carriers of antimicrobial resistance (AMR). However, there is a lack of validated methods for monitoring in the aquatic environment. Since extended-spectrum ß-lactamases (ESBLs) play a particularly important role in the clinical sector, a culturing method based on R2A-medium spiked with different combinations of ß-lactams was applied to quantify ß-lactamase-producing environmental bacteria from surface waters. In German surface water samples (n = 28), oligotrophic bacteria ranging from 4.0 × 103 to 1.7 × 104 CFU per 100 mL were detected on the nutrient-poor medium spiked with 3rd generation cephalosporins and carbapenems. These numbers were 3 log10 higher compared to ESBL-producing Enterobacteriales of clinical relevance from the same water samples. A MALDI-TOF MS identification of the isolates demonstrated, that the method leads to the isolation of environmentally relevant strains with Pseudomonas, Flavobacterium, and Janthinobacterium being predominant ß-lactam resistant genera. Subsequent micro-dilution antibiotic susceptibility tests (Micronaut-S test) confirmed the expression of ß-lactamases. The qPCR analysis of surface waters DNA extracts showed the presence of ß-lactamase genes (blaTEM, blaCMY-2, blaOXA-48, blaVIM-2, blaSHV, and blaNDM-1) at concentrations of 3.7 (±1.2) to 1.0 (±1.9) log10 gene copies per 100 mL. Overall, the results demonstrate a widespread distribution of cephalosporinase and carbapenemase enzymes in oligotrophic environmental bacteria that have to be considered as a reservoir of ARGs and contribute to the spread of antibiotic resistance.

9.
Diagnostics (Basel) ; 14(11)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38893702

RESUMEN

BACKGROUND: Malignant pleural effusion (MPE) affects up to 15% of patients with malignancy, and the prevalence is increasing. Non-expandable lung (NEL) complicates MPE in up to 30% of cases. However, it is not known if patients with malignant pleural effusion and NEL are more symptomatic in activities of daily living compared to patients with MPE with expandable lung. METHODS: This was an observational study on consecutively recruited patients with MPE from our pleural clinic. Before thoracentesis, patients completed patient-reported outcomes on cancer symptoms (ESAS), health-related quality of life (5Q-5D-5L), and dyspnoea scores. Following thoracentesis, patients scored dyspnoea relief and symptoms during thoracentesis. Data on focused lung ultrasound and pleural effusion biochemistry were collected. The non-expandable lung diagnosis was made by pleural experts based on radiological and clinical information. RESULTS: We recruited 43 patients, including 12 with NEL (28%). The NEL cohort resembled those from previous studies concerning ultrasonography, pleural fluid biochemistry, and fewer cases with high volume thoracentesis. Patients with and without NEL were comparable concerning baseline demography. The 5Q-5D-5L utility scores were 0.836 (0.691-0.906) and 0.806 (0.409-0.866), respectively, for patients with and without NEL. We observed no between-group differences in symptom burden or health-related quality of life. CONCLUSION: While the presence of NEL affects the clinical management of recurrent MPE, the presence of NEL seems not to affect patients' overall symptom burden in patients with MPE.

10.
Diagnostics (Basel) ; 14(2)2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38248080

RESUMEN

BACKGROUND: Non-expandable lung (NEL) has severe implications for patient symptoms and impaired lung function, as well as crucial implications for the management of malignant pleural effusion (MPE). Indwelling pleural catheters have shown good symptom relief for patients with NEL; hence, identifying patients early in their disease is vital. With the inability of the lung to achieve pleural apposition following thoracentesis and the formation of a hydropneumothorax, traditionally, chest X-ray and clinical symptoms have been used to make the diagnosis following thoracentesis. It is our aim to investigate whether ultrasound measurement of lung movement during respiration can predict NEL before thoracentesis, thereby aiding clinicians in their planning for the optimal treatment of affected patients. METHODS: A total of 49 patients were consecutively included in a single-centre trial performed at a pleural clinic. Patients underwent protocolled ultrasound assessment pre-thoracentesis with measurements of lung and diaphragm movement and shear wave elastography measurements of the pleura and pleural effusion at the planned site of thoracentesis. RESULTS: M-mode measurements of lung movement provided the best diagnostic ROC-curve results, with an AUC of 0.81. Internal validity showed good results utilising the calibration belt test and Brier test. CONCLUSION: M-mode measurement of lung movement shows promise in diagnosing NEL before thoracentesis in patients with known or suspected MPE. A validation cohort is needed to confirm the results.

11.
Appl Environ Microbiol ; 79(1): 328-35, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23124225

RESUMEN

Escherichia coli isolates (n = 300) collected from six sites in subtropical Brisbane, Australia, prior to and after storm events were tested for the presence of 11 virulence genes (VGs) specific to diarrheagenic pathotypes. The presence of eaeA, stx(1), stx(2), and ehxA genes specific for the enterohemorrhagic E. coli (EHEC) pathotype was detected in 56%, 6%, 10%, and 13% of isolates, respectively. The VGs astA (69%) and aggR (29%), carried by enteroaggregative (EAEC) pathotypes, were frequently detected in E. coli isolates. The enteropathogenic E. coli (EPEC) gene bfp was detected in 24% of isolates. In addition, enteroinvasive E. coli (EIEC) VG ipaH was also detected in 14% of isolates. During dry periods, isolates belonging to the EAEC pathotype were most commonly detected (23%), followed by EHEC (11%) and EPEC (11%). Conversely, a more uniform prevalence of pathotypes, EPEC (14%), EAEC (12%), EIEC (10%), EHEC (7%), and ETEC (7%), was observed after the storm events. The results of this study highlight the widespread occurrence of potentially diarrheagenic pathotypes in the urban aquatic ecosystems. While the presence of VGs in E. coli isolates alone is insufficient to determine pathogenicity, the presence of diarrheagenic E. coli pathotypes in high frequency after the storm events could lead to increased health risks if untreated storm water were to be used for nonpotable purposes and recreational activities.


Asunto(s)
Proteínas de Escherichia coli/genética , Escherichia coli/genética , Escherichia coli/aislamiento & purificación , Factores de Virulencia/genética , Microbiología del Agua , Australia , Genotipo , Prevalencia , Población Urbana
12.
Environ Monit Assess ; 185(8): 6645-52, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23264062

RESUMEN

Stormwater is one of the last major untapped urban water resources that can be exploited as an alternative water source in Australia. The information in the current Australian Guidelines for Water Recycling relating to stormwater harvesting and reuse only emphasises on a limited number of stormwater quality parameters. In order to supply stormwater as a source for higher value end-uses, a more comprehensive assessment on the potential public health risks has to be undertaken. Owing to the stochastic variations in rainfall, catchment hydrology and also the types of non-point pollution sources that can provide contaminants relating to different anthropogenic activities and catchment land uses, the characterisation of public health risks in stormwater is complex, tedious and not always possible through the conventional detection and analytical methods. In this study, a holistic approach was undertaken to assess the potential public health risks in urban stormwater samples from a medium-density residential catchment. A combined chemical-toxicological assessment was used to characterise the potential health risks arising from chemical contaminants, while a combination of standard culture methods and quantitative polymerase chain reaction (qPCR) methods was used for detection and quantification of faecal indicator bacteria (FIB) and pathogens in urban stormwater. Results showed that the concentration of chemical contaminants and associated toxicity were relatively low when benchmarked against other alternative water sources such as recycled wastewater. However, the concentrations of heavy metals particularly cadmium and lead have exceeded the Australian guideline values, indicating potential public health risks. Also, high numbers of FIB were detected in urban stormwater samples obtained from wet weather events. In addition, qPCR detection of human-related pathogens suggested there are frequent sewage ingressions into the urban stormwater runoff during wet weather events. Further water quality monitoring study will be conducted at different contrasting urban catchments in order to undertake a more comprehensive public health risk assessment for urban stormwater.


Asunto(s)
Ciudades , Eliminación de Residuos Líquidos/métodos , Aguas Residuales/química , Microbiología del Agua , Contaminantes del Agua/análisis , Calidad del Agua , Monitoreo del Ambiente , Aguas del Alcantarillado/microbiología , Aguas Residuales/microbiología , Aguas Residuales/toxicidad , Contaminantes del Agua/química , Contaminantes del Agua/toxicidad
13.
Sci Total Environ ; 899: 165481, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37442482

RESUMEN

Cryptosporidium oocysts pose a significant threat to public health due to its ability to contaminate environmental waters, leading to outbreaks of waterborne diseases and emphasizing the crucial need for effective water treatment and monitoring systems. This study aimed to investigate the decay of Cryptosporidium oocyst DNA in cow fecal matter under different environmental conditions prevalent in sub-tropical Southeast Queensland (SEQ) during summer and winter seasons. The effects of ambient sunlight and shaded conditions on the decay rates of C. parvum DNA in cow fecal samples were evaluated. The results showed that measurable levels of C. parvum DNA were observed for up to 60 days during the summer experiments, with a slower decay rate on the surface (k = -0.029) and sub-surface (k = -0.043) of the cowpat under shaded conditions than those on the surface (k = -0.064) and sub-surface (k = -0.079) under sunlight conditions. The decay rates of C. parvum DNA on the surface and sub-surface of the cowpat under shaded conditions were significantly slower (p = 0.004; p = 0.004) than those on the surface and sub-surface under sunlight conditions during summer experiments. During the winter treatments, measurable levels of C. parvum DNA were observed for up to 90 days, and the decay rates were slower on the surface (k = -0.036) and sub-surface (k = -0.034) of the cowpat under shaded conditions than those under sunlight conditions (k = -0.067 for surface and k = -0.057 for sub-surface). The decay rates of C. parvum DNA on the surface and sub-surface of the cowpat under shaded conditions were significantly slower than those on the surface (p = 0.009) and sub-surface (p = 0.041) under sunlight conditions during winter experiments. Moreover, the decay rate in the summer sunlight surface treatment (k = -0.064) was significantly faster from those in the winter shaded surface (k = -0.036; p = 0.018) and sub-surface (k = -0.034; p = 0.011) treatments. Similar results were also observed for summer sunlight sub-surface (k = -0.079), which was significantly faster than winter shaded surface (k = -0.036; p = 0.0008) and sub-surface (k = -0.034; p = 0.0005) treatments. Overall, these findings are important to enhance our understanding on the degradation of C. parvum DNA in cow fecal matter in SEQ, particularly in relation to seasonal variations and environmental conditions.


Asunto(s)
Criptosporidiosis , Cryptosporidium parvum , Cryptosporidium , Purificación del Agua , Animales , Purificación del Agua/métodos , Luz Solar , Oocistos
14.
Respir Med Case Rep ; 43: 101833, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36942163

RESUMEN

This is the first paper to report sampling of pancreatic lesions by EUS-B-FNA. A 76 year old patient suspected of primary lung cancer presented with a 36 × 24 mm lesion in the pancreas. Thoracentesis showed malignant cells suggestive of mucinous adenocarcinoma, but immunohistochemistry was inconclusive. Due to rapid deterioration of performance status of this frail patient, the program was shortened to EUS-B-FNA of the pancreatic lesion, which showed mucinous adenocarcinoma suggestive of primary pancreatic cancer. We conclude that EUS-B-FNA from a pancreatic lesion in the hands of a chest physician is feasible and diagnostic of a tumor in pancreas.

15.
Ugeskr Laeger ; 185(28)2023 07 10.
Artículo en Danés | MEDLINE | ID: mdl-37539795

RESUMEN

Solitary fibrous tumours (SFT) are rare soft tissue tumours with a primarily benign course. Complete surgical resection is the mainstay treatment. In this case report, a 75-year-old man had a massive intrathoracic SFT which was subsequently surgically resected without complications. Although the clinical presentation and CT features of these tumours can mimic lung cancer, the clinical course is significantly more favourable. Diagnostic examination and surgical treatment of intrathoracic SFT should be considered even in patients with increased post-operative risk.


Asunto(s)
Neoplasias de los Tejidos Blandos , Tumores Fibrosos Solitarios , Masculino , Humanos , Anciano , Tumores Fibrosos Solitarios/diagnóstico , Tumores Fibrosos Solitarios/patología , Tumores Fibrosos Solitarios/cirugía
16.
J Thorac Dis ; 15(7): 3965-3973, 2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37559642

RESUMEN

Biopsying lung tumours with endobronchial access in patients with respiratory impairment is challenging. However, fine needle aspiration with the endobronchial ultrasound-endoscope via the oesophagus (EUS-B-FNA) makes it possible to obtain tissue samples without entering the airways. Safety of EUS-B-FNA in these patients has not earlier been investigated prospectively. Therefore, this study aimed at assessing feasibility and safety of EUS-B-FNA from centrally located tumours suspected of thoracic malignancy in patients with respiratory insufficiency. The study is a prospective observational study. Patients with indication of EUS-B-FNA of centrally located tumours and respiratory impairment defined as modified Medical Research Council (mMRC) dyspnoea scale score of ≥3, saturation ≤90% or need of continuous oxygen supply were included prospectively in three centres. Any adverse events (AEs) were recorded during procedure and 1-hour recovery. AEs were defined as hypoxemia (saturation <90% or need for increased oxygen supply) or any kind of events needing intervention. Late procedure-related events were recorded during 30-day follow-up. Between April 1, 2020 and January 30, 2021, 16 patients were included. No severe AEs (SAEs) occurred, but AEs were seen in 50% (n=8) and 13% (n=2) of the patients during procedure and recovery respectively. AEs included hypoxemia corrected with increased oxygen supply and in two cases reversal of sedation. Late procedure-related events were seen in 13% (n=2) and included prolonged need of oxygen and one infection treated with oral antibiotics. In this cohort, EUS-B-FNA of centrally located tumours was safe and feasible in patients with respiratory impairment, when examined in the bronchoscopy suite. A variety of mostly mild and manageable complications may occur, a few even up to 30 days post-procedure.

17.
J Water Health ; 9(1): 10-26, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21301111

RESUMEN

Modern statistical models and computational methods can now incorporate uncertainty of the parameters used in Quantitative Microbial Risk Assessments (QMRA). Many QMRAs use Monte Carlo methods, but work from fixed estimates for means, variances and other parameters. We illustrate the ease of estimating all parameters contemporaneously with the risk assessment, incorporating all the parameter uncertainty arising from the experiments from which these parameters are estimated. A Bayesian approach is adopted, using Markov Chain Monte Carlo Gibbs sampling (MCMC) via the freely available software, WinBUGS. The method and its ease of implementation are illustrated by a case study that involves incorporating three disparate datasets into an MCMC framework. The probabilities of infection when the uncertainty associated with parameter estimation is incorporated into a QMRA are shown to be considerably more variable over various dose ranges than the analogous probabilities obtained when constants from the literature are simply 'plugged' in as is done in most QMRAs. Neglecting these sources of uncertainty may lead to erroneous decisions for public health and risk management.


Asunto(s)
Medición de Riesgo/métodos , Infecciones por Salmonella/epidemiología , Salmonella typhimurium/fisiología , Microbiología del Agua , Teorema de Bayes , Humanos , Cadenas de Markov , Modelos Biológicos , Modelos Estadísticos , Método de Montecarlo , Luz Solar , Incertidumbre , Australia Occidental/epidemiología
18.
J Thorac Dis ; 13(7): 3998-4007, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34422330

RESUMEN

BACKGROUND: The aims of the study were to develop an assessment tool in local anaesthetic thoracoscopy (LAT), investigate validity evidence, and establish a pass/fail standard. METHODS: Validity evidence for the assessment tool was gathered using the unified Messick framework. The tool was developed by five experts in respiratory medicine and medical education. Doctors with varying experience performed two consecutive procedures in a standardized, simulation-based setting using a newly developed thorax/lung silicone model. Performances were video-recorded and assessed by four expert raters using the new tool. Contrasting groups' method was used to set a pass/fail standard. RESULTS: Nine novices and 8 experienced participants were included, generating 34 recorded performances and 136 expert assessments. The tool had a high internal consistency (Cronbach's alpha =0.94) and high inter-rater reliability (Cronbach's alpha =0.91). The total item score significantly correlated with the global score (rs=0.86, P<0.001). Participants' first performance correlated to second performance (test-retest reliability) with a Pearson's r of 0.93, P<0.001. Generalisability (G) study showed a G-coefficient of 0.92 and decision (D) study estimated that one performance assessed by two raters or four performances assessed by one rater are needed to reach an acceptable reliability, i.e., G-coefficient >0.80. The tool was able to discriminate between the two groups in both performances: experienced mean score =30.8±4.2; novice mean score =15.8±2.3, P<0.001. Pass/fail standard was set at 22 points. CONCLUSIONS: The newly developed assessment tool showed solid evidence of validity and can be used to ensure competence in LAT.

19.
Food Environ Virol ; 13(3): 412-420, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34185277

RESUMEN

Roof-harvested rainwater (RHRW) is considered relatively clean water, even though the possible presence of pathogens in the water may pose human health risks. In this study, we investigated the occurrence of enteric viruses in the first flush (10 mm) of RHRW from a densely populated and low-income urbanized region of Rio de Janeiro. One hundred samples (5 L) were collected from 10 rainfall events between April 2015 and March 2017. RNA and DNA viruses were concentrated using the skimmed milk flocculation method and analyzed using the TaqMan® quantitative RT-qPCR and qPCR. Human adenoviruses, noroviruses, rotaviruses A, and avian parvoviruses were detected in 54%, 31%, 12%, and 12% of the positive samples. JC polyomavirus, also targeted, was not detected. Virus concentrations ranged from 1.09 × 101 to 2.58 × 103 genome copies/Liter (GC/L). Partial nucleotide sequence confirmed the presence of HAdV type 41, norovirus genotype GII.4, and avian parvovirus 1. The results suggest that the first flush diversion devices may not adequately remove enteric virus from the rainwater. Additional treatment of RHRW is required to mitigate potential health risks from potable use of captured water.


Asunto(s)
Adenovirus Humanos , Microbiología del Agua , Brasil , Floculación , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa
20.
J Environ Qual ; 39(6): 2029-39, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21284300

RESUMEN

The objective of the Parafield Aquifer Storage Transfer and Recovery research project in South Australia is to determine whether stormwater from an urban catchment that is treated in a constructed wetland and stored in an initially brackish aquifer before recovery can meet potable water standards. The water produced by the stormwater harvesting system, which included a constructed wetland, was found to be near potable quality. Parameters exceeding the drinking water guidelines before recharge included small numbers of fecal indicator bacteria and elevated iron concentrations and associated color. This is the first reported study of a managed aquifer recharge (MAR) scheme to be assessed following the Australian guidelines for MAR. A comprehensive staged approach to assess the risks to human health and the environment of this project has been undertaken, with 12 hazards being assessed. A quantitative microbial risk assessment undertaken on the water recovered from the aquifer indicated that the residual risks posed by the pathogenic hazards were acceptable if further supplementary treatment was included. Residual risks from organic chemicals were also assessed to be low based on an intensive monitoring program. Elevated iron concentrations in the recovered water exceeded the potable water guidelines. Iron concentrations increased after underground storage but would be acceptable after postrecovery aeration treatment. Arsenic concentrations in the recovered water continuously met the guideline concentrations acceptable for potable water supplies. However, the elevated concentration of arsenic in native groundwater and its presence in aquifer minerals suggest that the continuing acceptable residual risk from arsenic requires further evaluation.


Asunto(s)
Abastecimiento de Agua/análisis , Abastecimiento de Agua/normas , Australia , Conservación de los Recursos Naturales , Monitoreo del Ambiente , Concentración de Iones de Hidrógeno , Lluvia , Factores de Riesgo , Salinidad , Factores de Tiempo , Microbiología del Agua , Contaminantes Químicos del Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA